Loading...
HomeMy WebLinkAboutE300.1 - DRAWING STANDARDSPANEL DESIGNATION: TYP. UNIT PANEL VOLTAGE: 120/208 1Ø 3W MAIN AMPACITY: 150A MAIN LUGS BRANCH CIRCUITS: PLUG-IN REMARKS: CKT DESCRIPTION VA TRIP CKT DESCRIPTION VA TRIP 1 WASHER 1500 20A 2 LAUNDRY/HALL 526 20A 3 REFRIGERATOR 1500 20A 4 DRYER 5500 2P 5 DISPOSAL 720 15A 6 * 7 KITCHEN 1500 20A 8 WATER HEATER 6000 2P 9 KITCHEN 1500 20A 10 * 11 LIVING RM/DINING 1500 20A 12 CONDENSING UNIT 3661 2P 13 MASTER BED/OTHER 1500 20A 14 * 15 BATHROOM 500 20A 16 FURNACE BLOWER 600 15A 17 DISHWASHER 1200 20A 18 MICRO/HOOD 1600 20A 19 BATHROOM 500 20A 20 RANGE 9600 2P 21 BEDROOM 1000 20A 22 50A 23 GARAGE LTS/RECP 217 20A 24 GARAGE DOOR OPEN 500 15A 25 CAR CHARGER 4500 2P 26 27 CAR CHARGER 4500 50A 28 29 30 * AS REQ'D BY MFR. + ACTUAL VA VARIES BY UNIT TYPE;TOTAL VA 50124 HP-N (HOUSE PANEL - NORTH) 2540 SF @ 0.5 VA 1270 3 EH-1 9000 DED. FIRE PANEL CKT 500 BLDG EXTERIOR LIGHTING 600 GAS FURNACE 600 CONDENSER 3661 TOTAL 15631 15631VA / 208V = 75 100a HP-S (HOUSE PANEL - SOUTH) 2520 SF @ 0.5 VA 1260 3 EH-1 9000 EH-2 3000 BOOSTER PUMP 6240 DED. FIRE PANEL CKT 500 GAS FURNACE 600 CONDENSER 3661 TOTAL 24261 24261VA / 208V =117 125a PANEL DESIGNATION: HP-N VOLTAGE: 120/208 1Ø 3W MAIN AMPACITY: 100A MAIN LUGS BRANCH CIRCUITS: PLUG-IN REMARKS: CKT DESCRIPTION VA TRIP CKT DESCRIPTION VA TRIP 1 LIGHTS/RECP 317 20A 2 LIGHTS/RECP 318 20A 3 LIGHTS/RECP 317 20A 4 LIGHTS/RECP 318 20A 5 EH-1 3000 * 6 GAS FURNACE 600 15A 7 EH-1 3000 * 8 CONDENSER 1831 2P 9 EH-1 3000 * 10 CONDENSER 1830 25A 11 EXTERIOR LIGHTING 600 20A 12 FIRE PANEL CKT 500 20A 13 14 15 16 17 18 19 20 21 22 23 24 * AS REQ'D BY MFR. + ACTUAL VA VARIES BY UNIT TYPE;TOTAL VA 15631 PANEL DESIGNATION: HP-S VOLTAGE: 120/208 1Ø 3W MAIN AMPACITY: 125A MAIN LUGS BRANCH CIRCUITS: PLUG-IN REMARKS: CKT DESCRIPTION VA TRIP CKT DESCRIPTION VA TRIP 1 LIGHTS/RECP 315 20A 2 LIGHTS/RECP 315 20A 3 LIGHTS/RECP 315 20A 4 LIGHTS/RECP 315 20A 5 EH-1 3000 * 6 GAS FURNACE 600 15A 7 EH-1 3000 * 8 CONDENSER 1831 2P 9 EH-1 3000 * 10 CONDENSER 1830 25A 11 BOOSTER PUMP 3120 2P 12 EH-2 1500 2P 13 BOOSTER PUMP 3120 * 14 EH-2 1500 * 15 16 FIRE PANEL CKT 500 20A 17 18 19 20 21 22 23 24 * AS REQ'D BY MFR. + ACTUAL VA VARIES BY UNIT TYPE;TOTAL VA 24261 TYP. UNIT PANEL SIZING 1842 SF @ 3 VA 5526 433 GARAGE LTS/RECP 217 GARAGE DOOR OPENER 500 CAR CHARGER 9000 DRYER 5500 WASHER 1500 MICROWAVE/HOOD 1600 DISPOSAL 720 WATER HEATER 6000 REFRIGERATOR 1500 RANGE 9600 DISH WASHER 1200 2 APPLIANCE CKTS @ 1500 3000 TOTAL 45863 FIRST 10kVA AT 100% 10000 REMAINDER AT 40% 14345 100% OF COOLING EQUIP 3661 TOTAL VA 28006 28006VA / 208V = (AMPS) 135 150a Service 600A NORTH SERVICE # DESCRIPTION W EA. SUBT. 6 TYPICAL UNIT 50124 300,741 6 TOTAL UNITS 300,741 x DEMAND FACTOR 0.44 132,326 1 HOUSE PANEL 15631 15,631 1 ELEVATOR (VERIFY) 44000 44,000 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 TOTAL VA @ 208 V 191,957 TOTAL AMP DEMAND / (208 V *1.73)=533 A 600A SOUTH SERVICE # DESCRIPTION W EA. SUBT. 6 TYPICAL UNIT 50124 300,744 6 TOTAL UNIT # 300,744 x DEMAND FACTOR 0.44 132,327 1 HOUSE PANEL 24261 24,261 1 ELEVATOR (VERIFY) 44000 44,000 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 1 BLANK 0 0 TOTAL VA @ 208 V 200,588 TOTAL AMP DEMAND / (208 V *1.73)=557 A TYP. UNIT LOADS 1842 SF @ 3 VA 5526 433 GARAGE LTS/RECP 217 GARAGE DOOR OPENER 500 CAR CHARGER 9000 DRYER 5500 WASHER 1500 MICROWAVE/HOOD 1600 DISPOSAL 720 WATER HEATER 6000 REFRIGERATOR 1500 RANGE 9600 CONDENSING UNIT 3661 FURNACE BLOWER 600 2 APPLIANCES @ 1500 EA. 3000 DISH WASHER 1200 TOTAL 50124 SCALE: LOAD CALCULATIONS AND PANEL SCHEDULES E3-1 1 NA DATE SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURAL ELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET DATE REVISIONSFIREHOUSE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 46032DRAWING STANDARDS 11/02/2021 19.112REENIG NOIS ELA No. 19500207 ANAIDNI STATE OF S NORPE F TERED SIGERLISAMEEKER CRA N DALL1: Owner Review Set 3-04-2021 2: Construction Set 8-16-2021 3: Addendum 1 for Construction Set 11-01-2021 E3-1 01/31/22