Loading...
HomeMy WebLinkAboutGN010.3 - TYPICAL DETAILS1 0" 3'-1 0" MIN. 32" MAX.1 '-6" 6" MIN. 22" MIN32" MAX.6"MIN.32" MAX.6"MIN.6"MIN36-38" 3'-4" MIN. CONT. 2X FRAMING, TURNED SIDEWAYS 5/8" GYPSUM BOARD 2X FRAMING, TURNED SIDEWAYS, AT 16" O.C.AS NEEDEDSEE PLAN CONT. GYP. BD. BEHIND BULKHEAD USE TURNED STUDS TO MAXIMIZE OPEN SPACE WITHIN BULKHEAD 2X FRAMING AT 16" O.C. BETWEEN FLOOR TRUSSES TO SUPPORT CEILING FRAMING CONT. 2X FRAMING, TURNED SIDEWAYS, WITH BLOCKING IN WALL -TYP. 5/8" GYPSUM BOARD 2X FRAMING, TURNED SIDEWAYS, AT 16" O.C.AS NEEDEDSEE PLAN CONT. GYP. BD. BEHIND BULKHEAD USE TURNED STUDS TO MAXIMIZE OPEN SPACE WITHIN BULKHEAD SIDING, SEE EXTERIOR ELEVATIONS STUD WALL BATT INSULATION JAMB FRAMING, SEE HEADER SCHEDULE WEATHER RESISTANT BARRIER 1/4" GAP, CAULK EXTERIOR SHEATHING, SEE WALL SECTIONS BACKER ROD AND SEALANT WINDOW, SEE SCHEDULE CONTINUOUS SEALANT GYPSUM BOARD SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK HARDIETRIM, SEE EXTERIOR ELEVATIONS DOOR SIMILAR SIDING, SEE EXTERIOR ELEVATIONS. STUD WALL BATT INSULATION WEATHER RESISTANT BARRIER 1/4" GAP, CAULK EXTERIOR SHEATHING, SEE WALL SECTIONS PREFINISHED METAL FLASHING WITH DRIP EDGE WINDOW, SEE SCHEDULE CONTINUOUS SEALANT GYPSUM BOARD SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK HARDIETRIM, SEE EXTERIOR ELEVATIONS FACTORY PRIMED, FIELD PAINTED 1X POPLAR WOOD STOOL CONTINUOUS SEALANT SOLID WOOD BLOCKING SIDING, SEE EXTERIOR ELEVATIONS. WINDOW, SEE SCHEDULE BATT INSULATION WEATHER RESISTANT BARRIER 1/4" GAP, NO CAULK ABOVE FLASHING EXTERIOR SHEATHING, SEE WALL SECTIONS DRIP CAP TRIM STUD WALL HEADER, SEE SCHEDULE SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK HARDIETRIM, SEE EXTERIOR ELEVATIONS GYPSUM BOARD CONTINUOUS SEALANT STARTER STRIP (FOR LAP SIDING) CONT. METAL FLASHING DOOR SIMILAR DOOR AS SCHEDULED SEE SCHEDULE FOR HEADER AT LOAD-BEARING WALLS CONT. SEALANT ALL WOOD JOINTS NOTE: ADD JAMB EXTENSIONS AT ALL WALLS WITH TWO LAYERS OF GYPSUM BOARD WOOD STOP WOOD STUDS WITH GYP. BD. EA. SIDE WOOD DOOR FRAME WOOD CASING EACH SIDE DOOR AS SCHEDULED JAMB, SEE SCHEDULE CONT. SEALANT ALL WOOD JOINTS NOTE: ADD JAMB EXTENSIONS AT ALL WALLS WITH TWO LAYERS OF GYPSUM BOARD WOOD STOP WOOD DOOR FRAME WOOD STUDS WITH GYP. BD. EA. SIDE WOOD CASING EACH SIDE WINDOW, SEE SCHEDULE BATT INSULATION WEATHER RESISTANT BARRIER EXTERIOR SHEATHING, SEE WALL SECTIONSSTUD WALL HEADER, SEE SCHEDULE SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK MASONRY HEAD, SEE EXTERIOR ELEVATIONSGYPSUM BOARD CONTINUOUS SEALANT CONTINUOUS FLASHING WITH WEEPS AT 24" O.C. OR AT EACH STONE JOINT DOOR SIMILAR AIR GAP STEEL LINTEL, SEE SCHEDULE DRAINAGE MAT ABOVE ALL LINTEL LOCATIONS BACKER ROD AND SEALANT MASONRY VENEER, SEE EXTERIOR ELEVATIONS WINDOW, SEE SCHEDULE BATT INSULATION WEATHER RESISTANT BARRIER EXTERIOR SHEATHING, SEE WALL SECTIONS STUD WALL JAMB FRAMING, SEE HEADER SCHEDULE SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK MASONRY VENEER, SEE EXTERIOR ELEVATIONSGYPSUM BOARD CONTINUOUS SEALANT DOOR SIMILAR BACKER ROD AND SEALANT AIR GAP TURN BACK MASONRY AS REQUIREDMASONRY VENEER, SEE EXTERIOR ELEVATIONS STUD WALL BATT INSULATION WEATHER RESISTANT BARRIER AIR GAP EXTERIOR SHEATHING, SEE WALL SECTIONS WINDOW, SEE SCHEDULE CONTINUOUS SEALANT GYPSUM BOARD SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK MASONRY SILL WITH SLOPED TOP, SEE EXTERIOR ELEVATION FACTORY PRIMED, FIELD PAINTED 1X POPLAR WOOD STOOL CONTINUOUS SEALANT SOLID WOOD BLOCKING BACKER ROD AND SEALANT CONTINUOUS FLASHING WITH DRIP EDGE AND WEEPS AT 24" O.C. OR AT EACH STONE JOINT BLOCKING BLOCKINGBLOCKING BLOCKING ACCESSIBLE SHOWER CONTROLS MOUNTED IN THIS AREA ONLY DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 T1-3 TYPICAL DETAILS 03-05-2021 19112 1" = 1'-0"11 LOWERED CEILING DETAIL 1 1" = 1'-0"10 LOWERED CEILING DETAIL 2 1" = 1'-0" 2 WINDOW JAMB -SIDING 1" = 1'-0" 3 WINDOW SILL -SIDING 1" = 1'-0"1 WINDOW HEAD -SIDING 1" = 1'-0"7 DOOR HEAD 1" = 1'-0" 8 DOOR JAMB 1" = 1'-0"4 WINDOW HEAD -MASONRY 1" = 1'-0" 5 WINDOW JAMB -MASONRY 1" = 1'-0" 6 WINDOW SILL -MASONRY 1/4" = 1'-0" 9 TYPE B BATHROOM ELEVATIONS 01/31/22