HomeMy WebLinkAboutGN010.4 - WALL TYPESFLOORING BASE AS SCHEDULED 2X SILL PLATE, USE TREATED LUMBER AT ALL FIRST FLOOR WALLS 5/8" GYP. BD. EACH SIDE, SMOOTH FINISH -OPTIONAL 5/8" GYP. GYP. BD. SMOOTH FINISH SEE WALL SECTIONS 2X4 OR 2X6 STUDS AT 16" O.C. A1 5/8" 3 1/2" 5/8" 4 3/4" PROJECT USE: 2X4 / 2X6 INTERIOR NON-BEARING WALLS A2 PROVIDE 5/8" WATER-RESISTANT GYP. BD. ON BATHROOM / PLUMBING FIXTURE WALLS 2X4 STANDARD 2X6 STANDARD R-11 SOUND BATT INSULATION - SEE PLAN FOR LOCATIONSOMIT WALL SURFACE WHEN USED AS A FURRING WALL FLOORING BASE AS SCHEDULED 2X SILL PLATE, USE TREATED LUMBER AT ALL FIRST FLOOR WALLS 5/8" GYP. BD. EACH SIDE, SMOOTH FINISH CABINET, TIGHT TO WALL 2X4 STUDS AT 16" O.C. C1 5/8" 3 1/2" 5/8" 4 3/4" COUNTERTOP 1" AT SEATING 10 1/2" PROJECT USE: KITCHEN ISLAND 1/2 WALL FLOORING BASE AS SCHEDULED 2X SILL PLATE, USE TREATED LUMBER AT ALL FIRST FLOOR WALLS 5/8" GYP. BD. EACH SIDE, SMOOTH FINISH GYP. BD. SMOOTH FINISH SEE WALL SECTIONS 2X2 OR 2X4 STUD FURRING AT 16" O.C. 5/8" PROJECT USE: 2X2 & 2X4 WALL FURRING PRIMARY WALL TYPE BEYOND B2 2X4 STANDARD PROVIDE 5/8" WATER-RESISTANT GYP. BD. ON BATHROOM/PLUMBING FIXTURE SIDE B1 2X2 STANDARD NOTE: INSTALL THIS PIPING IN EVERY UNIT. SEE BUILDING FOUNDATION PLANS FOR LOCATIONS TO RECIEVE VAPORMAT (IF APPLICABLE). SEE ROOF PLANS FOR LOCATIONS TO RECIEVE MITIGATION FANS. GOOSENECK WITH STAINLESS STEEL BUG AND PEST SCREEN FLASHING PER ROOFING MANUFACTURER'S STANDARD ROOF STUD WALL PIPE SLEEVE CONCRETE SLAB GRAVEL BED STAINLESS STEEL MESH OVER MEMBRANE TIE END OF PIPE INTO VAPORMAT SYSTEM WHEN SYSTEM IS IMPLEMENTED STAINLESS STEEL BAND SEAL PIPE PENETRATION SEAL AROUND SLEEVE PIPE SUPPORT AT MAXIMUM 8'-0" O.C. 4" SCHEDULE 40 PVC PIPE CEILING JOIST ROUTE PIPE IN ATTIC SUCH THAT VENT IS ON THE BACK SIDE OF THE BUILDING CLAMP SHEET METAL STRAP CUT PIPE AND TERMINATE IN ATTIC. ONLY PENETRATE ROOF WHEN MITIGATION FAN IS REQUIRED6' - 4"1' - 4"1' - 10"1' - 4"1' - 10"NOTE: PROVIDE SUPPORT BRACKET EVERY 36" O.C. AS REQUIRED. SEE PLAN FOR LENGTH OF SHELVING 1' - 4"1' - 10"1' - 4"1' - 10"6' - 4"1' - 4" 4 FIXED SHELVES SUPPORT BRACKET 4 FIXED SHELVES SUPPORT BRACKET6' - 0"1' - 4"1' - 4"1' - 4"2' - 0"NOTES: -PROVIDE SUPPORT BRACKET EVERY 36" O.C. AS REQUIRED. SEE PLAN FOR LENGTH OF SHELVING -SEE PLAN NOTES FOR DEPTH AT EACH CLOSET 1' - 4"1' - 4"1' - 4"2' - 0"6' - 0"1' - 4" 4 FIXED SHELVES SUPPORT BRACKET 4 FIXED SHELVES SUPPORT BRACKET 6' - 0"1' - 4"1' - 4"1' - 4"2' - 0"NOTE: PROVIDE SUPPORT BRACKET EVERY 36" O.C. AS REQUIRED. SEE PLAN FOR LENGTH OF SHELVING 1' - 4"1' - 4"1' - 4"2' - 0"6' - 0"1' - 0" 4 FIXED SHELVES SUPPORT BRACKET 4 FIXED SHELVES SUPPORT BRACKET DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 T1-4 WALL TYPES AND DETAILS 03-05-2021 19112 NON-RATED WALL TYPES 1/4" = 1'-0"1 RADON PIPING DETAIL 3/8" = 1'-0"2 PANTRY SHELVES 3/8" = 1'-0"3 16" LINEN SHELVES 3/8" = 1'-0"4 12" LINEN SHELVES 01/31/22