HomeMy WebLinkAboutGN010.5 - FLASHING AND FRAMING DETAILS2-2X TOP PLATE HEADER, SEE SCHEDULE HEADER, SEE SCHEDULE WINDOW SILL -FLAT 2X 2X4 OR 2X6 WALL STUD SUBFLOOR / SLAB JOIST BEARING SHIM SPACE WITH MINIMALLY EXPANDING POLYURETHANE FOAM AND APPROVED CAULK CLAD DOOR SIMILAR WINDOW FLASHING PROCESS INTERIOR VIEW TOP LEFT CORNER OF WINDOW SEALANT 3 SECURE WRB AT HEAD 8 FLASHING AT HEAD EXTENDS 1" BEYOND JAMB FLASHING HEAD FLASHING7 EMBEDED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE 8 1/2" JAMB FLASHING EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTEND JAMB FLASHING 8 1/2" ABOVE ROUGH OPENING AT HEAD. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. 5 JAMB FLASHING APPLY CONT. SEAL TO THE MOUNTING FLAGES AT THE TOP (HEAD) AND SIDES (JAMBS) OF WINDOW. EXTEND SEALANT AT JAMBS 8 1/2" ABOVE THE R.O. AT HEAD. EMBED JAMB FLASHING INTO SEALANT AND FASTEN IN PLACE. (FLASHING GOES OVER SEALANT). 5 8 1/2" 5 2 2 5 2 1 8 6 SILL FLASHING SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER SPECIFICATIONS. WEATHER RESISTANT BARRIER (WRB)1 AT A 45 DEGREE ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS AND CENTER TO THE EXTERIOR WRB SURFACE ABOVE. 9" 1 8 9" 135° SEALANT 4 SEAL THE WINDOW FRAME TO OPENING. APPLY A 3/8" NOM. DIA. TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS. 3 WINDOW FLASHING SECTION. SEE DETAIL ON T2-2 THROUGH WINDOW JAMB SEALANT BEAD BEHIND MOUNTING FLANGE. SEALANT BEAD BETWEEN FLASHING AND MOUNTING WRB FLASHING WINDOW FLASHING GENERAL NOTES 1. WEATHER RESISTIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE. 2. ALL FLASHING WILL BE SELF ADHEARING AND ROLLED SMOOTH & FLAT WITH A J-ROLLER. STEPS: 1 IN WATER SHEDING FASHION STARTING AT THE BASE OF THE WALL & WORKING TOWARDS THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING. 2 APPLY SILL FLASHING THROUGH WINDOW OPENING AND DOWN WALL; THEN APPLY JAMB FLASHING THROUGH WINDOW OPENING AND ACROSS WALL; CREATING A FULLY FLASHED WINDOW ROUGH OPENING. 3 WRAP WINDOW WITH INSULATION, APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE AND SET WINDOW USING PAN HEAD SCREWS TO FACILITATE INSPECTION. 4 APPLY BEAD OF SEALANT AT SIDE JAMBS. EXTEND 8 1/2" 5 APPLY JAMB FLASHING. 6 APPLY BEAD OF SEALANT AT HEAD. 7 APPLY HEAD FLASHING. 8 REMOVE PREVIOUSLY APPLIED TAPE, ALLOWING WRB TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SHEATHING TAPE OVER DIAGONAL CUT -SEE DIAGRAM. NOTE: STEPS 4 AND 6 ARE NOT REQUIRED WHEN USING SELF-ADHERING TYPE FLASHING TOP PLATE WALL STUDS FLAT 2X HEADER AT NON-LOAD BEARING INTERIOR WALLS ONLY. SUBFLOOR / SLAB JOIST BEARING LEAVE OPENING IN WALL FOR DRYWALL LOADING 3' - 0"SUBFLOOR / SLAB JOIST BEARING AFTER DRYWALL LOADING, INSTALL STUDS EXTERIOR SHEATHING, AND WEATHER BARRIER DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 T1-8 FLASHING AND FRAMING DETAILS 03-05-2021 19112 1/2" = 1'-0"4 DOOR/WINDOW OPENING 1/8" = 1'-0"1 WINDOW FLASHING SECTION & ISOMETRIC 1/2" = 1'-0"3 NON-BEARING WALL 1/2" = 1'-0" 2 DRYWALL SCUTTLE 01/31/22