HomeMy WebLinkAboutGN010.43 - WALL TYPESUL-L55O OR UL-L579 PROPRIETARY 1 HOUR FIRE 54 TO 57 STC - SOUND 1' - 4" 3" 3" 1' - 4" 1' - 4" 1' - 6"(DETAIL CF-1) TYPICAL FLOOR/CEILING ASSEMBLY (UNIT SEPARATION) ONE LAYER 5/8" PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO RESILIENT CHANNELS 16" O.C. (12" O.C. WHEN INSULATION BATTS OR BLANKETS ARE DRAPED OVER RESILIENT CHANNELS OR WHEN LOOSE FILL INSULATION IS APPLIED TO THE BACK OF THE CEILING MEMBRANE) WITH 1" TYPE S DRYWALL SCREWS 8" O.C. GYPSUM BOARD END JOINTS LOCATED MIDWAY BETWEEN CONTINUOUS CHANNELS AND ATTACHED TO ADDITIONAL PIECES OF CHANNEL 60" LONG WITH SCREWS 8" O.C. RESILIENT CHANNELS APPLIED AT RIGHT ANGLES TO MINIMUM 12" DEEP PARALLEL CHORD WOOD TRUSSES AT MAXIMUM 24" O.C. WITH 1-1/4" TYPE S DRYWALL SCREWS. 23/32" PLYWOOD OR OSB SUBFLOOR SHEATHING APPLIED AT RIGHT ANGLES TO TRUSSES WITH CONTRUCTION ADHESIVE AND 6d RING SHANK NAILS 12" O.C. 1 1/4" PROPRIETARY GYPSUM FLOOR TOPPING APPLIED OVER SUBFLOOR. OPTIONAL CEILING DAMPER (REFER TO MANUFACTURER FOR INFORMATION ON THE TYPE OF DAMPER). 5-1/2" GLASS FIBER INSULATION STAPLED TO UNDERSIDE OF FLOOR SHEATHING IN JOIST SPACES, 1 1/4" PROPRIETARY GYPSUM FLOOR TOPPING POURED OVER 1/4" PROPRIETARY SOUND REDUCTION MAT. PROPRIETARY GYPSUM BOARD - UNITED STATES GYPSUM COMPANY (5/8" SHEETROCK BRAND FIRECODE C CORE GYPSUM PANELS), LEVELROCK BRAND FLOOR UNDERLAYMENT ASSEMBLY: APPROX. WEIGHT: 3 PSF FIRE TEST: UL R1319, 97NK28582, 11-20-97, UL R5698, 04NK16820, 6-29-04, UL DESIGN L521: UL R9660, 99NK7096, 5-17-99, UL DESIGN L550; UL R15858, 02NK24136, 3-20-03 SOUND TEST: RAL OT04-01, 1-19-04; RAL OT04-03, 1-20-04; RAL OT04-05, 1-21-04; RAL OT04-07, 1-26-04; RAL OT04-11, 1-16-04; IIC & TEST: (81 GENERIC C&P), RAL OT04-06, 1-21-04; (55 CUSHION SHEET VINYL) RAL OT04-04, 1-20-04; (55 ENGINEERED WOOD LAMINATE) RAL OT04-08, 1-26-04; (54 CERAMIC TILE RAL OT04-12, 4-16-04; (53 GENERIC SHEET VINYL) RAL OT04-02, 1-19-04 ONE LAYER 5/8" TYPE X GYP. BD. T&G SHEATHING RESILIANT CHANNEL 1 1/4" GYPCRETE SOUND BATT INSULATION APPLIED TO UNDERSIDE OF FLOOR SHEATHING 50 IIC MIN 1/4" SOUND REDUCTION MAT ADDITIONAL LAYER OF 5/8" TYPE X GYP. BD. AT CEILING OF GARAGES 1. EACH PROPRIETARY SYSTEM LISTS SPECIFIC PRODUCTS THAT ARE ACCEPTABLE FOR USE IN THE SPECIFIC SYSTEM IN WHICH THEY ARE LISTED. CONTACT THE MANUFACTURER FOR MORE DETAILED INFORMATION ON PROPRIETARY PRODUCTS. 2. UNLESS OTHERWISE SPECIFIED THE FACE LAYERS OF ALL SYSTEMS, EXCEPT THOSE PRE-DECORATED OR METAL COVERED SURFACES, SHALL HAVE JOINTS TAPED (MIN. LEVEL 1). 3. METAL STUDS AND RUNNERS ARE NOMINAL 25 GAUGE UNLESS OTHERWISE SPECIFIED. 4. SPECIFIED FLOORS -CEILING AND ROOF -CEILING FRAMING SIZES OR TRUSS DIMENSIONS ARE MINIMUMS. GREATER JOIST OR TRUSS SIZES (DEPTHS) SHALL BE PERMITTED TO BE USED IN METAL -OR WOOD-FRAMED SYSTEMS. INDICATED JOIST AND TRUSS SPACINGS ARE MAXIMUMS. 5. SYSTEMS TESTED WITH METAL FURRING CHANNELS ATTACHED DIRECTLY TO THE BOTTOM CHORDS OF STEEL BEAMS, BAR JOISTS, OR WOOD TRUSSES OR FRAMING SHALL BE PERMITTED TO BE SUSPENDED. GENERALLY, FURRING CHANNELS ARE ATTACHED TO 1-1/2 INCH COLD ROLLED CARRYING CHANNELS 48" O.C. SUSPENDED FROM JOISTS BY 8 GAGE WIRE HANGERS SPACED NOT GREATER THAN 48" O.C. 6. ADDITIONAL LAYERS OF TYPE 'X' OR REGULAR GYPSUM BOARD SHALL BE PERMITTED TO BE ADDED TO ANY SYSTEM. 7. SCREWS MEETING ASTM C 1002 SHALL BE PERMITTED TO BE SUBSTITUTED FOR THE PRESCRIBED NAILS, ONE FOR ONE, WHEN THE LENGTH AND HEAD DIAMETER OF THE SCREWS EQUAL OR EXCEED THOSE OF THE NAILS SPECIFIED IN THE TEST SYSTEM AND THE SCREW SPACING DOES NOT EXCEED THE SPACING SPECIFIED FOR THE NAILS IN THE TESTED SYSTEM. 8. GREATER STUD SIZES (DEPTHS) SHALL BE PERMITTED TO BE USED IN METAL -OR WOOD-STUD SYSTEMS. METAL STUDS OF HEAVIER GAGE THAN THOSE TESTED SHALL BE PERMITTED. THE ASSIGNED RATING OF ANY LOAD-BEARING SYSTEM SHALL ALSO APPLY TO THE SAME SYSTEM WHEN USED AS A NON LOAD-BEARING SYSTEM. INDICATED STUD SPACINGS ARE MAXIMUMS. 9. ALL FIRE-RESISTIVE SYSTEMS SHALL BE FIRE BLOCKED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. 10. ALL PENETRATIONS IN A FIRE-RATED SYSTEM SHALL BE FILLED WITH FIRESTOPPING MATERIAL AS REQUIRED BY LOCAL CODE. 11. WHEN NOT SPECIFIED AS A COMPONENT OF A FIRE TESTED WALL OR PARTITION SYSTEM, MINERAL FIBER, GLASS FIBER, OR CELLULOSE FIBER INSULATION OF A THICKNESS NOT EXCEEDING THAT OF THE STUD DEPTH SHALL BE PERMITTED TO BE ADDED WITHIN THE STUD CAVITY. 12. PENETRATIONS (BOTH THROUGH PENETRATIONS AND MEMBRANE PENETRATIONS) OF WALL OR FLOOR/CEILING ASSEMBLIES SHALL BE FIRE- RATED WITH AN APPROVED ASSEMBLY OR FIRESTOP SYSTEM. EXCEPTIONS INCLUDE: A MEMBRANE PENETRATIONS OF ELECTRICAL BOXES OF ANY MATERIAL WHICH HAVE BEEN TESTED FOR USE IN A FIRE-RATED ASSEMBLY OR NON-LISTED METAL BOXES, PROVIDED BOXES ON OPPOSITE SIDES OF FIRE-RATED WALL ARE SEPARATED BY A HORIZONTAL DISTANCE OF 24-INCHES OR SEPARATED BY SOLID FIRE-BLOCKING PER OR SEPARATED ACCORDING TO THE LISTING OF THE BOX. 13. THE "APPROVED PENETRATION FIRESTOP SYSTEM" MUST BE INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E814 OR UL1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE A FIRE-RATING NOT LESS THAN THE REQUIRED FIRE- RESISTANCE RATING OF THE WALL PENETRATION. 14. ALTHOUGH THERE ARE MANY FIRESTOP SOLUTIONS, INCLUDING FIRE CAULK, INTUMESCENT SEALS, OR COLLAR SYSTEMS, THE SPECIFIC SYSTEM USED IN THIS PROJECT SHALL HAVE A UL NUMBER THAT GIVES THE INSTALLATION INFORMATION AND THE RATINGS AS TESTED BY UL. A COPY OF THE UL REPORT SHALL BE PROVIDED TO THE LOCAL FIRE MARSHALL FOR APPROVAL PRIOR TO ITS INSTALLATION. 15. THE ADDITION OF WOOD STRUCTURAL PANELS IN FIRE-RATED GYPSUM BOARD ASSEMBLIES IS PERMITTED AS DESCRIBED IN THIS SECTION. WOOD STRUCTURAL PANELS THAT ARE 4 FT WIDE, MINIMUM 7/16" THICK ORIENTED STRAND BOARD (OSB) OR 15/32" THICK STRUCTURAL SHEATHING (PLYWOOD) COMPLYING WITH DOC PS1 OR PS2, OR APA STANDARD PRP-108, MANUFACTURED WITH EXTERIOR GLUE, MAY BE APPLIED HORIZONTALLY OR VERTICALLY, TO THE FRAMING MEMBERS. VERTICAL JOINTS SHOULD BE CENTERED ON STUDS, AND STAGGERED ON STUD SPACE FROM THE GYPSUM BOARD JOINTS. THE WOOD STRUCTURAL PANELS ARE PERMITTED TO BE APPLIED EITHER AS (1) A BASE LAYER (DIRECTLY TO THE WALL FRAMING AND UNDER THE GYPSUM BOARD), (2) IN BETWEEN GYPSUM BOARD LAYERS, OR (3) OVER THE TOP OF THE COMPLETED GYPSUM BOARD LAYERS. WHEN WOOD STRUCTURAL PANELS ARE USED ON TOP OF THE GYPSUM BOARD LAYERS OF EXTERIOR WALL ASSEMBLIES, THE WOOD STRUCTURAL PANEL SHOULD BE PROTECTED FROM THE EXTERIOR ENVIRONMENT EITHER AS SPECIFIED IN THE DESIGN OR AS SPECIFIED UNDER ITEM 10, EXTERIOR WALLS, BELOW. WHEN WOOD STRUCTURAL PANELS ARE ADDED TO THE WALL ASSEMBLY, THE LENGTH OF THE FASTENER USED FOR THE OUTERMOST LAYER (EITHER GYPSUM BOARD OR WOOD STRUCTURAL PANEL) SHOULD BE SIZED APPROPRIATELY TO ACCOMMODATE THE ADDITIONAL THICKNESS OF THE WALL PANEL. FIRE-RESISTANCE RATED SYSTEM NOTES GA FILE NO RC 2602 GENERIC 1 HOUR FIRE N/A - SOUND BASE LAYER 5/8" TYPE "X" GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S DRYWALL SCREWS 24" O.C. FACE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S DRYWALL SCREWS 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES AND 1 1/2" TYPE G DRYWALL SCREWS 12" O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER JOINTS. WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8d NAILS. APPROPRIATE ROOF COVERING. CEILING PROVIDES ONE HOUR FIRE PROTECTION RESISTANCE PROTECTION FOR TRUSSES. ASSEMBLY: (DETAIL CF-2) TYPICAL ROOF/CEILING APPROX. WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72: ITS, 8-6-98VARIABLE TWO LAYERS 5/8" TYPE X GYP SHEATHING (SEE ROOF PLAN FOR RATED SHEATHING LOCATIONS) SEE WALL SECTION DETAILS FOR INSULATION LOCATIONS AND TYPE GA FILE NO FC 5529, 5530, 5531 GENERIC 1 HOUR FIRE N/A - SOUND BASE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO WOOD I JOISTS/TRUSSES/WOOD JOISTS 24" O.C. WITH 1-1/4" TYPE W OR S DRYWALL SCREWS 24" O.C. FACE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO I-JOISTS/TRUSSES/WOOD JOISTS WITH 1-7/8" TYPE W OR S DRYWALL SCREWS 12" O.C. AT JOINTS AND INTERMEDIATE I- JOISTS/TRUSSES/WOOD JOISTS AND 1-1/2" TYPE G DRYWALL SCREWS 12" O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER JOINTS. WOOD I-JOISTS/TRUSSES/WOOD JOISTS SUPPORTING 1/2" WOOD STRUCTURAL PANELS APPLIED AT RIGHT ANGLES TO JOISTS WITH 8d NAILS. GA FILE NO. FC 5530 - CEILING PROVIDES ONE-HOUR FIRE-RESISTANCE PROTECTION FOR I-JOISTS. GA FILE NO. FC5531 - CEILING PROVIDES ONE-HOUR FIRE-RESISTIVE PROTECTION FOR TRUSSES. *SUBSTITUTE TWO LAYERS GEORGIA-PACIFIC TOUGHROCK® FOR GYPSUM - MANUFACTURED TO MEET ASTM C1396 SECTION 8; CSA-A82.27-M; AND FEDERAL SPECIFICATION SS-L-30D, TYPE III, GRADE X, CLASS 1. ASSEMBLY: (DETAIL CF-3) TYPICAL EXTERIOR ROOF/CEILING & FLOOR/CEILING ASSEMBLY (BALCONIES) 24" MIN. JOINT OFFSET TWO LAYERS 5/8" TOUGHROCK FIREGUARD C SOFFIT BOARD SHEATHING -SLOPE AT ROOF TRUSSES (SEE ROOF PLAN FOR RATED SHEATHING LOCATIONS) SEE WALL SECTION DETAILS FOR INSULATION LOCATIONS AND TYPE APPROX. WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98VARIABLE24" MIN. JOINT OFFSET TWO LAYERS 5/8" TOUGHROCK FIREGUARD C SOFFIT BOARD SHEATHING -SLOPE AT ROOF TRUSSES (SEE ROOF PLAN FOR RATED SHEATHING LOCATIONS) SEE WALL SECTION DETAILS FOR INSULATION LOCATIONS AND TYPE WOOD TRUSS WOOD I-JOIST OR MIN. 2X10 WOOD JOISTS GA FILE NO FC 5751 GENERIC 2 HOUR FIRE N/A - SOUND BASE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO 18" MIN. DEEP PARALLEL CHORD WOOD TRUSSES 24" O.C. MAXIMUM WITH 1-1/4" TYPE W DRYWALL SCREWS 12" O.C. SECOND LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO TRUSSES WITH 2" TYPE W DRYWALL SCREWS 12" O.C. SECOND LAYER JOINTS OFFSET 24" FROM BASE LAYER JOINTS THIRD LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO TRUSSES WITH 2-1/2" TYPE W DRYWALL SCREWS 12" O.C. THIRD LAYER JOINTS OFFSET 12" FROM SECOND LAYER JOINTS. HAT-SHAPED 7/8" RIGID FURRING CHANNELS 24" O.C. APPLIED AT RIGHT ANGLES TO TRUSSES OVER THIRD LAYER WITH TWO 2-1/2" LONG TYPE W DRYWALL SCREWS AT EACH TRUSS. FACE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO FURRING CHANNELS WITH 1-1/8" TYPE S DRYWALL SCREWS 12" O.C. WOOD TRUSSES SUPPORTING 3/4" T&G EDGE PLYWOOD FLOOR APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8d NAILS 6" O.C. AT JOINTS AND 12" AT INTERMEDIATE TRUSSES. CEILING PROVIDES TWO-HOUR FIRE RESISTANCE PROTECTION FOR WOOD FRAMING. ASSEMBLY: (DETAIL CF-4) TYPICAL EXTERIOR ROOF/CEILING ABOVE EGRESS STAIRS APPROX. WEIGHT: 12 PSF FIRE TEST: UL R4024, 00NK26545, 4-27-01 UL DESIGN L556: ULC DESIGN M514VARIABLE BASE, SECOND, AND THIRD LAYER SHEATHING -SLOPE AT ROOF TRUSSES (SEE ROOF PLAN FOR RATED SHEATHING LOCATIONS) SEE WALL SECTION DETAILS FOR INSULATION LOCATIONS AND TYPE WOOD TRUSS HAT CHANNELS AT 24" O.C. FACE LAYER DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 T1-7 RATED CEILING AND ROOF TYPES 03-05-2021 19112 01/31/22