HomeMy WebLinkAboutLS001.0 - LIFE SAFETY PLANSDWELLING UNIT SEPARATION GENERAL NOTES 1. DWELLING UNITS IN MULTI-FAMILY BUILDINGS SHALL BE SEPARATED FROM EACH OTHER BY WALL AND/OR FLOOR ASSEMBLIES HAVING NOT LESS THAN 1-HOUR FIRE-RESISTANCE RATING PER SECTION 420.2 AND 420.3 2. PENETRATIONS (BOTH THROUGH PENETRATIONS AND MEMBRANE PENETRATIONS) OF WALL OR FLOOR/CEILING ASSEMBLIES SHALL BE FIRE-RATED WITH AN APPROVED ASSEMBLY OR FIRESTOP SYSTEM. EXCEPTIONS INCLUDE: A. MEMBRANE PENETRATIONS OF ELECTRICAL BOXES OF ANY MATERIAL WHICH HAVE BEEN TESTED FOR USE IN A FIRE-RATED ASSEMBLY OR NON-LISTED METAL BOXES, PROVIDED BOXES ON OPPOSITE SIDES OF FIRE-RATED WALL ARE SEPARATED BY A HORIZONTAL DISTANCE OF 24-INCHES OR SEPARATED BY SOLID FIRE-BLOCKING OR SEPARATED ACCORDING TO THE LISTING OF THE BOX OR PROTECTED WITH LISTED PUTTY PADS. 3. THE APPROVED PENETRATION FIRESTOP SYSTEM' (SUCH AS REQUIRED AT THE DUCTWORK PENETRATIONS THROUGH RATED CEILINGS) MUST BE INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E814 OR UL1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE A FIRE-RATING NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL PENETRATION. 4. ALTHOUGH THERE ARE MANY FIRESTOP SOLUTIONS, INCLUDING FIRE CAULK, INTUMESCENT SEALS, OR COLLAR SYSTEMS, THE SPECIFIC SYSTEM USED IN THIS PROJECT SHALL HAVE A UL NUMBER THAT GIVES THE INSULATION INFORMATION AND THE RATINGS AS TESTED BY UL. A COPY OF THE UL REPORT SHALL BE PROVIDED TO THE LOCAL FIRE MARSHALL FOR APPROVAL PRIOR TO ITS INSTALLATION. BUILDING CODE ANALYSIS: 2014 INDIANA BUILDING CODE (IBC) BASED UPON 2012 INTERNATIONAL BUILDING CODE WITH INDIANA AMENDMENTS. TYPE VA CONSTRUCTION OCCUPANCY GROUP: U-OCCUPANCY (FIRST FLOOR GARAGES) R-2 -OCCUPANCY (SECOND, THIRD, AND FOURTH FLOOR CONDOMINIUMS) NON-SEPARATED USES. FULLY SPRINKLED WITH NFPA 13R SYSTEM AT DWELLING UNITS INCLUDING ALL EXTERIOR BALCONIES WITH A ROOF / CANOPY ABOVE AND NFPA 13 AT GARAGES. ALLOWABLE AREA PER STORY: 9,000 S.F. (WITHOUT INCREASES)(BASED ON U OCCUPANCY 4 STORIES ALLOWED WITH FIRE SUPRESSION SYSTEM (NFPA 13R)(SECTION 504.2)(BASED ON R-2 OCCUPANCY) BUILDING USEABLE AREA CALCULATIONS U -OCCUPANCY -1ST FLOOR 7,983 S.F. R-2 OCCUPANCY -2ND FLOOR 7,602 S.F. R-2 OCCUPANCY -3RD FLOOR 8,180 S.F. R-2 OCCUPANCY -4TH FLOOR 8,214 S.F. TOTAL BUILDING AREA:31,979 S.F. ONE EXIT IS REQUIRED FROM EACH DWELLING UNIT PER 1021.2 EXCEPTION 5 AND 1051.1 EXCEPTION 1. TWO EXISTS REQUIRED FROM EACH FLOOR PER 1021.2 MAXIMUM 20' DEAD END CORRIDORS. 250' MAXIMUM EXIT ACCESS TRAVEL DISTANCE (TABLE 1016.2). 125' MAXIMUM COMMON PATH OF EGRESS TRAVEL (TABLE 1014.3). EXTERIOR BEARING AND NON-BEARING WALLS: 1 HOUR(TABLES 601/602), 0 HOUR FOR TABLE 602 IF FIRE SEPARATION EQUAL TO OR GREATER THAN 30' INTERIOR BEARING WALLS: 1 HOUR (TABLE 601) INTERIOR NON-BEARING WALLS: 0 HOUR (TABLE 601) EXIT ACCESS CORRIDORS: 1/2 HOUR FIRE PARTITION (SECTION708.1 AND 1018.1) EXIT STAIR ENCLOSURES: 2 HOUR FIRE BARRIER (SECTION 1009.2.2 AND 1022.2). STAIR ENCLOSURE CAN STOP AT UNDERSIDE OF THE RATED FLOOR / CEILING ASSEMBLY ABOVE PER SECTION 713.12 FLOORS: FLOOR-CEILING ASSEMBLIES: 1 HOUR (TABLE 601) ROOFS: ROOF-CEILING ASSEMBLIES: 1 HOUR (TABLE 601) UNIT SEPARATIONS: 1 HOUR FIRE PARTITION (SECTION 708.1) STRUCTURAL FRAME: 1 HOUR (TABLE 601) SHAFTS: 2 HOUR FIRE BARRIER(SECTION 713.2) *ONE HOUR CEILING MEMBRANES ARE PERMITTED TO BE INTERRUPTED WITH A DOUBLE WOOD TOP PLATE OF A FIRE RESISTIVE-RATED WALL ASSEMBLY. PENETRATING ITEMS THROUGH THE DOUBLE TOP PLATES ARE REQUIRED TO BE PROTECTED WITH THROUGH PENETRATION FIRE STOP SYSTEMS PER SECTION 714.5.2 EXIT DISCHARGE - THE STAIRWAY IS PERMITTED TO EXIT THROUGH THE LEVEL OF EXIT DISCHARGE PROVIDED THE EXIT IS READABLY VISIBLE FROM TERMINATION OF STAIR ENCLOSURE. EXITS -BASED ON SPACES WITH ONE (1) EXIT THE MAXIMUM TRAVEL DISTANCE WITHIN THE UNIT TO WHERE AN OCCUPANT HAS A CLEAR CHOICE OF TWO EXITS IS 125 FEET AND A MAXIMUM OCCUPANT LOAD OF 10 PER SECTION TABLE 1014.3/1015.1. EXITS ON EACH FLOOR ARE REQUIRED TO BE SEPARATED BY A MINIMUM OF ONE-THIRD (1/3) THE OVERALL LARGEST DIAGONAL DISTANCE. DRAFTSTOPPING -REQUIRED FOR CONCEALED SPACES AND ATTIC (BASED UPON THE BUILDING IS PROTECTED WITH AN NFPA 13R SYSTEM) AS FOLLOWS: -DRAFTSTOPPING IN ATTIC AREAS IN LINE WITH THE DWELLING UNIT SEPARATIONS AND FIRE BARRIERS. (PER SECTION 718.4.2). -DRAFTSTOPPING IN FLOOR/CEILING ASSEMBLIES IN LINE WITH THE DWELLING UNIT SEPARATIONS (PER SECTION 718.3.2). FIREBLOCKING -REQUIRED IN THE FOLLOWING AREAS: -CONCEALED WALL SPACES -CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES -STAIRWAY STRINGERS AND TOP/BOTTOM OF THE RUN -VENTS, PIPES DUCTS AT CEILING AND FLOOR LEVELS ATTIC ACCESS -REQUIRED WHEN THE HEADROOM CLEARANCES ARE 30 INCHES OR GREATER. ATTIC ACCESS OPENING IS REQUIRED TO BE NOT LESS THAN 20 INCHES BY 30 INCHES. KEY BOX -KEY (KNOX) BOX IS REQUIRED PER SECTION 506.1 IFC. KNOX BOX CAN BE ORDERED THROUGH KNOX BOX.COM INTERIOR FINISHES -R-2 (SPRINKLED) -VERTICAL EXITS, EXIT ACCESS CORRIDORS AND OTHER EXIT WAYS, ROOMS AND ENCLOSED SPACES: CLASS C -FLAME SPREAD 76-200/SMOKE DEVELOPMENT 0-450 ACCESSIBILITY FOR R-2: CHAPTER 11 OF THE 2014 IBC, 2009 ANSI A117.1, AND FAIR HOUSING AMENDMENT ACT (HUD). ALL DWELLING UNITS ON EACH FLOOR SERVED AND ACCESSED BY AN ELEVATOR ARE REQUIRED TO BE TYPE “B”UNITS. ACCESSIBLE ENTRANCE ROUTE INTO AND THROUGH THE DWELLING UNIT A. DOORS PROVIDED ARE REQUIRED TO HAVE A NET CLEARANCE OF 32 INCHES. B. THRESHOLDS AT UNIT INTERIOR DOORS TO HAVE A MAXIMUM HEIGHT OF THREE-FOURTHS INCHES. THRESHOLDS AT UNIT ENTRY DOORS TO BE FULLY ACCESSIBLE. C. MANEUVERING CLEARANCE AT UNIT ENTRY DOORS TO BE FULLY ACCESSIBLE, BOTH SIDES. D. KITCHENS ARE REQUIRED TO HAVE A CLEAR FLOOR SPACE OF THIRTY (30) INCHES BY FORTY-EIGHT (48) INCHES. AT EACH FIXTURE AND APPLIANCE. E. BATHROOMS ARE TO HAVE A MINIMUM THIRTY (30) INCH BY FORTY-EIGHT (48) INCH CLEAR FLOOR SPACE IN FRONT OF WATER CLOSETS AND LAVATORIES. F. UTILITY ROOMS ARE REQUIRED TO HAVE REQUIRED CLEAR FLOOR SPACE AND REACH RANGES FOR CONTROLS FOR WASHER, DRYER, WATER SOFTENER ETC. G. PORCHES/ BALCONIES/ PATIOS TO BE MAXIMUM 2" BELOW INTERIOR FINISHED FLOOR. 1. LIGHT SWITCHES, ELECTRICAL OUTLETS, ELECTRICAL PANELS, THERMOSTATS, AND OTHER ENVIRONMENTAL CONTROLS ARE TO BE A MAXIMUM OF 48 INCHES FROM FLOOR TO TOP OF OPERABLE PARTS. 2. REINFORCEMENTS IN BATHROOMS TO ALLOW LATER INSTALLATION OF GRAB BARS AROUND THE TOILET, TUB, SHOWER STALL, AND SHOWER SEAT, WHERE SUCH FACILITIES ARE PROVIDED. CAULK WITH THERMOFIBER SMOKE SEAL COMPOUND IMPALLING PIN AND SHIELD AT ALL CORNERS 2" THERMOFIBER FIRE SAFING SYSTEM RECESSED LIGHT FIXTURE CAULK WITH SMOKE SEAL FIRE-RATED FLOOR/CEILING ASSEMBLY AIR SPACE 1" MIN. TRUSS FIRE-RATED, INSULATED, BABCOCK DAVIS 22" X 36" ACCESS PANEL AND FRAME TRUSS 2' - 0" O.C. CEILING FINISH -SEE RATED CEILING DETAILS AND WALL SECTIONS TRUSS SPRING HINGES -TYP. 3/8" PLYWOOD DOOR 2X4 FRAME, ROUTED METAL CABINET PULL PLAN ELEVATION 3"1/2"3' - 6"1/2"3 1/4"3 1/4" 1/2" 1' - 10 1/2" 1/2" 3" TRUSS DRAFT STOP 2X4 FRAME, ROUTED 3/8" PLYWOOD DOOR 1/2" 3"3/4"3/4"1' - 10 1/2" 1' - 11 1/2" 2' - 5 3/4" STUD WALL CONSTRUCTION CONTINUOUS PERIMETER SEALANTV.W.M.VERIFY WITH MANUFACTURER SEE PLANWALL HEATER UNIT SEE MECH. DRAWINGS MANUFACTURER SUPPLIED UL RATED WALL BOX FIRE RETARDANT WOOD BLOCKING AS REQUIRED MANUFACTURER SUPPLIED FIRE RATED INSULATION CONTINUOUS PERIMETER SEALANTSEE PLANFIRE EXTINGUISHER PREFINISHED FIRE EXTINGUISHER CABINET FIRE RETARDANT WOOD BLOCKING AS REQUIRED DOOR HANDLE -SWING OF DOOR TO COINCIDE W/ PATH OF EGRESS STUD WALL CONSTRUCTION DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 LS-0 LIFE SAFETY NOTES AND ANALYSIS 03-05-2021 19112 1 1/2" = 1'-0"1 CAN LIGHT DETAIL 1 1/2" = 1'-0"2 RATED ATTIC DOOR 1 1/2" = 1'-0" 3 DRAFT STOP DOOR 1 1/2" = 1'-0"5 WALL HEATER DETAIL 1 1/2" = 1'-0"4 F.E. CABINET DETAIL 01/31/22