HomeMy WebLinkAboutLS001.01 - LIFE SAFETY PLANSUP UP UP UP 1ST LEVEL +99' -5" 2ND LEVEL FLATS +110' -9 3/8" 4TH LEVEL FLATS +134' -4 1/8" 3RD LEVEL FLATS +122' -6 3/4" T.O. PARAPET +150' -0" TRUSS BEARING +144' -5 1/4" A4-5 1 5 55 UNIT 12 GARAGE UNIT 10 GARAGE UNIT 9 GARAGE UNIT 7 GARAGE BREEZEWAY UNIT 1 GARAGE UNIT 3 GARAGE UNIT 4 GARAGE UNIT 6 GARAGE UNIT 8 GARAGE UNIT 7 GARAGE UNIT 10 GARAGE UNIT 9 GARAGE UNIT 12 GARAGE UNIT 11 GARAGE UNIT 2 GARAGE UNIT 1 GARAGE UNIT 4 GARAGE UNIT 3 GARAGE UNIT 6 GARAGE UNIT 5 GARAGE SOUTHWEST EGRESSNORTHWEST EGRESS 2 2 2 22 2 1 11 1 11 11 1111 12 12 12 12 12 12 12 12 12 12 12 12 TYP.TYP. - - - - - - EXIT EXIT 1 33 1 EXIT EXIT EXITEXIT EXIT EXITEXIT 1 3 1 3 44 5 5 5TYP. TYP. TYP. 5 TYP. 7 UNIT 1 GARAGE UNIT 3 GARAGE UNIT 4 GARAGE UNIT 6 GARAGE UNIT 5 GARAGE UNIT 2 GARAGE SOUTH LOBBY ELEC. / DATA SPRINKLER ROOM BREEZEWAY UNIT 7 GARAGE UNIT 9 GARAGE UNIT 10 GARAGE UNIT 12 GARAGE UNIT 11 GARAGE UNIT 8 GARAGE NORTH LOBBY DOG WASHJANITOR ELEC. / DATA NORTHWEST EGRESS NORTHEAST EGRESS SOUTHWEST EGRESSSOUTHEAST EGRESS ELEVATORELEVATOR 1010 F.E.F.E. 5 TYP. 2 TYP. 6 EXIT 5 TYP. 2 TYP. 2 TYP. 6 DISTANCE22'-7"NOTE: NOTE:7 2 TYP. 2 TYP. 2 TYP. 6 5 TYP. 6 DISTANCE24'-9"LIFE SAFETY PLAN LEGEND: ONE HOUR FIRE PARTITION. INSTALL DRAFTSTOP DIRECTLY ABOVE IN TRUSS SPACE. ONE HOUR FIRE-RATED WALL CONSTRUCTION, UNPROTECTED OPENINGS. TWO HOUR FIRE BARRIER DRAFT STOP IN TRUSS SPACE 1-HOUR FIRE RATED FLOOR / CEILING ASSEMBLY -SEE T1-7, DETAIL CF-1 1-HOUR FIRE RATED EXTERIOR FLOOR / CEILING ASSEMBLY -SEE T1-7, DETAIL CF-3 1-HOUR FIRE RATED ROOF/CEILING ASSEMBLY -SEE T1-7, DETAIL CF-2 F.E.FIRE EXTINGUISHER -VERIFY LOCATIONS WITH LOCAL FIRE DEPARTMENT EXIT EGRESS EXIT INTERNAL COMPONENTS OF COMMON STAIRS -NOT RATED. INSTALL ONE LAYER 5/8" GYPSUM BOARD ON UNDERSIDE OF STAIRS / FRAMING 2-HOUR FIRE RATED ROOF / CEILING ASSEMBLY -SEE DETAIL T1-7, DETAIL CF-4 LIFE SAFETY PLAN GENERAL NOTES 1. FIRE EXTINGUISHERS SHALL BE LARSONS MODEL MP-10 OR EQUAL 2. FIRE EXTINGUISHER CABINETS (IF APPLICABLE) SHALL BE LARSONS MODEL 2409-6R, SEMI- RECESSED, STAINLESS STEEL FINISH, SOLID DOOR WITH RECESSED HANDLE, AND RED TYPE- A DIE-CUT LETTERS 3. GARAGE TO BE SPRINKLERED WITH NFPA 13 SYSTEM, ALL OTHER AREAS TO BE SPRINKLERED WITH NFPA 13R SYSTEM. SPRINKLER SYSTEM TO BE DESIGNED AND SUBMITTED FOR APPROVAL BY OTHERS. 4. SEE ELECTRICAL DRAWINGS FOR EXIT SIGN AND LIGHT LOCATIONS, AS WELL AS FIRE ALARMS AND STROBES. 5. ALL RECESSED CAN LIGHTS IN FIRE-RATED CEILINGS MUST BE INSTALLED IN FIRE-RATED HOUSING PROVIDED BY MANUFACTURER OR ENCLOSED PER DETAIL 4/LS1-1 6. EXCEPT WHERE A VARIANCE IS BEING APPLIED FOR, ALL EXTERIOR WALLS SHALL BE ONE- HOUR FIRE-RATED PER TABLE 601/602 FOR TYPE VA CONSTRUCTION. 7. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2" GYPSUM BOARD, 3/8" WOOD STRUCTURAL PANEL, 3/8" PARTICLEBOARD, 1" NOMINAL LUMBER, CEMENT FIBERBOARD, OR OTHER APPROVED MATERIAL ADEQUATELY SUPPORTED. 8. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT SIGNS, EXIT LIGHTS, AND FIRE ALARM SYSTEM. DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 LS-1 LIFE SAFETY PLANS 03-05-2021 19112 1/8" = 1'-0"2 FIRE RATING -LIFE SAFETY SECTION LIFE SAFETY PLAN KEYNOTES 1 TWO-HOUR FIRE BARRIER WITH 1 1/2 HOUR RATED OPENINGS AROUND STAIRS. FROM FLOOR SLAB UP TO UNDERSIDE OF TWO HOUR FIRE RATED FLOOR/CEILING ASSEMBLY OR UNDERSIDE OF ROOF SHEATHING 2 ONE-HOUR FIRE PARTITION (UNIT SEPARATION WALL) FROM FLOOR SLAB/ SHEATHING UP TO UNDERSIDE OF THE FIRE-RESISTANT RATED ASSEMBLY ABOVE. INSTALL DRAFT STOP DIRECTLY ABOVE WALL IN TRUSS SPACE FROM TOP OF WALL UP TO UNDERSIDE OF FLOOR/ ROOF SHEATHING ABOVE. SEE "L1/L2/S1/S2/T1/T2" WALL TYPES ON SHEET T1-5. SEE BUILDING PLANS FOR WALL TYPES AT EACH LOCATION. 3 COMMON STAIRS - PROVIDE ONE LAYER OF 5/8 GYP. AT UNDERSIDE OF STAIRS AND CEILINGS BETWEEN FLOORS 4 MASONRY ELEVATOR SHAFT - TWO-HOUR FIRE BARRIER UP TO UNDERSIDE OF ROOF SHEATHING ABOVE. 5 ONE-HOUR FIRE-RESISTIVE RATED WALL PER TABLE 601, NO RATING REQUIRED BY TABLE 602 DUE TO FIRE SEPARATION DISTANCE GREATER THAN 30'. OPENINGS ARE UNPROTECTED 6 ONE - HOUR FLOOR/CEILING OR ROOF/CEILING ASSEMBLY SEE DETAIL CF-3 ON SHEET T1-7 7 VARIANCE SUBMITTED FOR REMOVAL OF ONE-HOUR FIRE-RESISTANCE RATED WALL PER TABLE 602 WITH ENHANCED SPRINKLER SYSTEM. ENHANCED SPRINKLER SYSTEM IS TO PROVIDE SPRINKLER HEADS AT 6'-0" O.C. MAXIMUM ALONG EXTERIOR WALLS 8 MECHANICAL CHASE - SEE PLAN DETAIL M1 ON T1-6 9 ROOF ACCESS DOOR - SERVICE AND EMERGENCY ACCESS ONLY 10 FIRE EXTINGUISHER IN WALL CABINET 11 ONE-HOUR FIRE RATED ROOF / CEILING ASSEMBLY 12 ONE-HOUR FIRE RATED FLOOR / CEILING ASSEMBLY 13 DRAFT STOP IN TRUSS SPACE IN LINE WITH FIRE PARTITION, FIRE BARRIER, OR EXTERIOR WALL BELOW. 14 FIRE EXTINGUISHER IN SINK CABINET ON BRACKET 1/8" = 1'-0"1 1ST LEVEL -LIFE SAFETY PLANN N 01/31/22