HomeMy WebLinkAboutLS001.01 - LIFE SAFETY PLANSUP
UP UP
UP
1ST LEVEL
+99' -5"
2ND LEVEL FLATS
+110' -9 3/8"
4TH LEVEL FLATS
+134' -4 1/8"
3RD LEVEL FLATS
+122' -6 3/4"
T.O. PARAPET
+150' -0"
TRUSS BEARING
+144' -5 1/4"
A4-5
1
5
55
UNIT 12
GARAGE
UNIT 10
GARAGE
UNIT 9
GARAGE
UNIT 7
GARAGE
BREEZEWAY UNIT 1
GARAGE
UNIT 3
GARAGE
UNIT 4
GARAGE
UNIT 6
GARAGE
UNIT 8
GARAGE
UNIT 7
GARAGE
UNIT 10
GARAGE
UNIT 9
GARAGE
UNIT 12
GARAGE
UNIT 11
GARAGE
UNIT 2
GARAGE
UNIT 1
GARAGE
UNIT 4
GARAGE
UNIT 3
GARAGE
UNIT 6
GARAGE
UNIT 5
GARAGE
SOUTHWEST EGRESSNORTHWEST EGRESS
2
2
2 22 2
1 11 1
11 11 1111
12 12 12 12
12 12 12 12
12 12 12 12
TYP.TYP.
-
-
-
-
-
-
EXIT
EXIT
1 33 1
EXIT
EXIT
EXITEXIT
EXIT
EXITEXIT
1
3
1
3
44
5
5
5TYP.
TYP.
TYP.
5 TYP.
7
UNIT 1
GARAGE
UNIT 3
GARAGE
UNIT 4
GARAGE
UNIT 6
GARAGE
UNIT 5
GARAGE
UNIT 2
GARAGE
SOUTH LOBBY
ELEC. / DATA
SPRINKLER
ROOM
BREEZEWAY UNIT 7
GARAGE
UNIT 9
GARAGE
UNIT 10
GARAGE
UNIT 12
GARAGE
UNIT 11
GARAGE
UNIT 8
GARAGE
NORTH LOBBY
DOG WASHJANITOR
ELEC. / DATA
NORTHWEST EGRESS NORTHEAST EGRESS SOUTHWEST EGRESSSOUTHEAST EGRESS
ELEVATORELEVATOR
1010
F.E.F.E.
5 TYP.
2
TYP.
6
EXIT
5 TYP.
2
TYP.
2
TYP.
6
DISTANCE22'-7"NOTE:
NOTE:7
2
TYP.
2
TYP.
2
TYP.
6
5 TYP. 6 DISTANCE24'-9"LIFE SAFETY PLAN LEGEND:
ONE HOUR FIRE PARTITION. INSTALL
DRAFTSTOP DIRECTLY ABOVE IN
TRUSS SPACE.
ONE HOUR FIRE-RATED WALL
CONSTRUCTION, UNPROTECTED
OPENINGS.
TWO HOUR FIRE BARRIER
DRAFT STOP IN TRUSS SPACE
1-HOUR FIRE RATED FLOOR / CEILING
ASSEMBLY -SEE T1-7, DETAIL CF-1
1-HOUR FIRE RATED EXTERIOR FLOOR
/ CEILING ASSEMBLY -SEE T1-7,
DETAIL CF-3
1-HOUR FIRE RATED ROOF/CEILING
ASSEMBLY -SEE T1-7, DETAIL CF-2
F.E.FIRE EXTINGUISHER -VERIFY LOCATIONS
WITH LOCAL FIRE DEPARTMENT
EXIT EGRESS EXIT
INTERNAL COMPONENTS OF COMMON
STAIRS -NOT RATED. INSTALL ONE
LAYER 5/8" GYPSUM BOARD ON
UNDERSIDE OF STAIRS / FRAMING
2-HOUR FIRE RATED ROOF / CEILING
ASSEMBLY -SEE DETAIL T1-7, DETAIL
CF-4
LIFE SAFETY PLAN
GENERAL NOTES
1. FIRE EXTINGUISHERS SHALL BE LARSONS MODEL MP-10 OR EQUAL
2. FIRE EXTINGUISHER CABINETS (IF APPLICABLE) SHALL BE LARSONS MODEL 2409-6R, SEMI-
RECESSED, STAINLESS STEEL FINISH, SOLID DOOR WITH RECESSED HANDLE, AND RED TYPE-
A DIE-CUT LETTERS
3. GARAGE TO BE SPRINKLERED WITH NFPA 13 SYSTEM, ALL OTHER AREAS TO BE
SPRINKLERED WITH NFPA 13R SYSTEM. SPRINKLER SYSTEM TO BE DESIGNED AND
SUBMITTED FOR APPROVAL BY OTHERS.
4. SEE ELECTRICAL DRAWINGS FOR EXIT SIGN AND LIGHT LOCATIONS, AS WELL AS FIRE
ALARMS AND STROBES.
5. ALL RECESSED CAN LIGHTS IN FIRE-RATED CEILINGS MUST BE INSTALLED IN FIRE-RATED
HOUSING PROVIDED BY MANUFACTURER OR ENCLOSED PER DETAIL 4/LS1-1
6. EXCEPT WHERE A VARIANCE IS BEING APPLIED FOR, ALL EXTERIOR WALLS SHALL BE ONE-
HOUR FIRE-RATED PER TABLE 601/602 FOR TYPE VA CONSTRUCTION.
7. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2" GYPSUM BOARD, 3/8" WOOD
STRUCTURAL PANEL, 3/8" PARTICLEBOARD, 1" NOMINAL LUMBER, CEMENT FIBERBOARD, OR
OTHER APPROVED MATERIAL ADEQUATELY SUPPORTED.
8. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT SIGNS, EXIT LIGHTS, AND FIRE ALARM
SYSTEM.
DATE
155 EAST MARKET STREETSECOND FLOOR, SUITE 200
INDIANAPOLIS, INDIANA 46204
T 317.721.2724
ROTTMANNCOLLIER.COM
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT CECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDIACATED OR
DESCRIBED, TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
SHEET
PROJECT NO.
REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET
08-16-2021 CONSTRUCTION SET
11-01-2021 ADDENDUM 1
LS-1
LIFE SAFETY PLANS
03-05-2021
19112
1/8" = 1'-0"2 FIRE RATING -LIFE SAFETY SECTION
LIFE SAFETY PLAN KEYNOTES
1 TWO-HOUR FIRE BARRIER WITH 1 1/2 HOUR RATED OPENINGS AROUND STAIRS. FROM FLOOR
SLAB UP TO UNDERSIDE OF TWO HOUR FIRE RATED FLOOR/CEILING ASSEMBLY OR UNDERSIDE
OF ROOF SHEATHING
2 ONE-HOUR FIRE PARTITION (UNIT SEPARATION WALL) FROM FLOOR SLAB/ SHEATHING UP TO
UNDERSIDE OF THE FIRE-RESISTANT RATED ASSEMBLY ABOVE. INSTALL DRAFT STOP DIRECTLY
ABOVE WALL IN TRUSS SPACE FROM TOP OF WALL UP TO UNDERSIDE OF FLOOR/ ROOF
SHEATHING ABOVE. SEE "L1/L2/S1/S2/T1/T2" WALL TYPES ON SHEET T1-5. SEE BUILDING PLANS
FOR WALL TYPES AT EACH LOCATION.
3 COMMON STAIRS - PROVIDE ONE LAYER OF 5/8 GYP. AT UNDERSIDE OF STAIRS AND CEILINGS
BETWEEN FLOORS
4 MASONRY ELEVATOR SHAFT - TWO-HOUR FIRE BARRIER UP TO UNDERSIDE OF ROOF SHEATHING
ABOVE.
5 ONE-HOUR FIRE-RESISTIVE RATED WALL PER TABLE 601, NO RATING REQUIRED BY TABLE 602
DUE TO FIRE SEPARATION DISTANCE GREATER THAN 30'. OPENINGS ARE UNPROTECTED
6 ONE - HOUR FLOOR/CEILING OR ROOF/CEILING ASSEMBLY SEE DETAIL CF-3 ON SHEET T1-7
7 VARIANCE SUBMITTED FOR REMOVAL OF ONE-HOUR FIRE-RESISTANCE RATED WALL PER TABLE
602 WITH ENHANCED SPRINKLER SYSTEM. ENHANCED SPRINKLER SYSTEM IS TO PROVIDE
SPRINKLER HEADS AT 6'-0" O.C. MAXIMUM ALONG EXTERIOR WALLS
8 MECHANICAL CHASE - SEE PLAN DETAIL M1 ON T1-6
9 ROOF ACCESS DOOR - SERVICE AND EMERGENCY ACCESS ONLY
10 FIRE EXTINGUISHER IN WALL CABINET
11 ONE-HOUR FIRE RATED ROOF / CEILING ASSEMBLY
12 ONE-HOUR FIRE RATED FLOOR / CEILING ASSEMBLY
13 DRAFT STOP IN TRUSS SPACE IN LINE WITH FIRE PARTITION, FIRE BARRIER, OR EXTERIOR WALL
BELOW.
14 FIRE EXTINGUISHER IN SINK CABINET ON BRACKET
1/8" = 1'-0"1 1ST LEVEL -LIFE SAFETY PLANN
N
01/31/22