HomeMy WebLinkAboutM500 - DETAILSLINESETS * DIMENSION SUBJECT TO CHANGE22" *6"1 2 " 28 "1 2" *1 2" * 22 " CEILING EXHAUST FAN DETAIL NOT TO SCALE DETAIL 'A' FIRE DAMPER AT FIRE RATED WALL DETAIL NOT TO SCALE DETAIL 'A' FIRE DAMPER AT FIRE RATED WALL DETAIL NOT TO SCALE GRILLE EXHAUST RECTANGULAR OR BACKDRAFT DAMPER CEILING MOUNT FAN TO FINISHED CEILING FRAMING. PROVIDE NEOPRENE VIBRATION ISOLATORS. ROUND DUCTWORK AS SPECIFIED ON PLANS INSTALLATION TO BE IN COMPLIANCE WITH MANUFACTURERS INSTRUCTIONS PROVIDE CLEARANCE ON TOP & SIDES FOR EXPANSION FIRE RATED WALL 18 GAUGE SLEEVE FIRE RATED WALL SEE DETAIL 'A' WHERE WALL IS CONSTRUCTED OF WOOD OR STEEL JOISTS VERTICAL CURTAIN TYPE STATIC FIRE DAMPER WITH UL RATING FOR 1-1/2 HR UNLESS OTHERWISE NOTED. (SIMILAR TO RUSKIN IBD2 STYLE "A") FASTEN DUCT TO SLEEVE WITH 'S' SLIP ON TOP & BOTTOM & DRIVE SLIP ON SIDES RETAINING ANGLES SHALL BE 2"x2"x1/8" & SHALL BE SECURED TO 18 GA. SLEEVE WITH 1/2" WELDS AT 6" O.C. DO NOT SECURE ANGLES TO WALL. PROVIDE ANGLES ON ALL FOUR SIDES OF SLEEVE & BOTH SIDES OF WALL. WOOD OR STEEL JOISTS CARRY FIRE RESISTANT LINING ON ALL SIDES OF OPENING RETAINING ANGLE 18 GAUGE SLEEVE GRILLE FIRE DAMPER FRAME FUSIBLE LINK (165°F) STEEL BLADES WITH INTERLOCKING JOINTS EXPAND DUCT SO THAT FIRE DAMPER DOES NOT REDUCE AREA OF DUCT, EXPANSION IN WIDTH IS ACCEPTABLE PROVIDE SEALANT TO JOINT ALL AROUND DUCTWORK-SEE PROJECT DRAWINGS FOR SIZE AND CONTINUATION GRILLE INSTALLATION TO BE IN COMPLIANCE WITH MANUFACTURERS INSTRUCTIONS PROVIDE CLEARANCE ON TOP & SIDES FOR EXPANSION FIRE RATED WALL PROVIDE SEALANT TO JOINT ALL AROUND ON BOTH SIDES OF WALL 18 GAUGE COLLAR FIRE RATED WALL SEE DETAIL 'A' & 'B' WHERE WALL IS CONSTRUCTED OF WOOD OR STEEL JOISTS VERTICAL CURTAIN TYPE STATIC FIRE DAMPER WITH UL RATING FOR 1-1/2 HR UNLESS OTHERWISE NOTED. (SIMILAR TO RUSKIN IBD2 STYLE "B") DUCTWORK-SEE PROJECT DRAWINGS FOR SIZE AND CONTINUATION DOUBLE WALL, HINGED, GASKETED AND INSULATED ACCESS PANEL, (LABEL "FIRE DAMPER ACCESS DOOR") FASTEN DUCT TO SLEEVE WITH 'S' SLIP ON TOP & BOTTOM & DRIVE SLIP ON SIDES RETAINING ANGLES SHALL BE 2"x2"x1/8" & SHALL BE SECURED TO 18 GA. COLLAR WITH 1/2" WELDS AT 6" O.C. DO NOT SECURE ANGLES TO WALL OR FLOOR. PROVIDE ANGLES ON ALL FOUR SIDES OF SLEEVE & BOTH SIDES OF WALL OR FLOOR. FIRE DAMPER FRAME RETAINING ANGLE WOOD OR STEEL JOISTS CARRY FIRE RESISTANT LINING ON ALL SIDES OF OPENING SLEEVE FUSIBLE LINK (165°F) STEEL BLADES WITH INTERLOCKING JOINTS SOUND LINING WHERE INDICATED METAL NOSING OVER INTERNAL INSULATION CONNECTION REFRIGERANT GAUGE CONTROL WIRING REFRIGERANT LIQUID LINE WITH INSULATION REFRIGERANT SUCTION LINE SERVICE VALVES CONDENSING UNIT FAN GUARD AIR-COOLED CONDENSING UNIT DETAIL NOT TO SCALE TYPICAL WALL PENETRATION DETAIL NOT TO SCALE PIPE SLEEVE OR SHEET METAL SLEEVE 3/4" SPACE PACKED WITH FIBROUS MATERIAL ALL AROUND BUILDING WALL OR FLOOR PIPE NON-HARDENING RESILIENT SEALANT BOTH SIDES DUCT IF OPENING LIMITED TO DESIRED 3/4" SPACE PACK WITH FIBROUS MATERIAL AND SEAL BOTH SIDES WITH RESILIENT NON-HARDENING SEALER. IF OPENING STRUCTURE IS IRREGULAR AND GREATER THAN 1", WRAP DUCT WITH 1" THICK FIBROUS MATERIAL AND FILL REMAINING OPENING WITH GROUT. DUCT LINING AS REQUIRED FIRE DAMPER ACCESS PANEL IN CEILING REFRIGERANT PIPING ROOF HOOD & CURB DETAIL SCALE: NONE (NOTE: COORDINATE CURBS & FLASHING WITH SPECIFIED ROOF CONSTRUCTION) ELECTRIC UNIT HEATER DETAIL NOT TO SCALE POWER SUPPLY JUNCTION BOX WALL SWITCH DISCONNECT NON-FUSED EXPANSION ANCHORS MINIMUM7'-0" A.F.F.ELECTRIC SLAB J MOUNTING RODS (4) THREADED SUPPLY AIR UNIT HEATER PACK WITH FIBERGLASS INSULATION CEILING MOUNTED SUPPLY REGISTER INSTALLATION DETAIL NOT TO SCALE INSULATED FLEX DUCT CEILING SUPPLY AIR REGISTER WITH OPPOSED BLADE VOLUME DAMPER SUPPLY DUCT RADIATION DAMPER AT RATED CEILINGS MOORE ENGINEERING SERVICES, INC. 6340 LaPas Trail Indianapolis, IN 46268 Phone (317) 291-1052 FAX (317) 298-2729R I G EEIS PE60860351 No.REENIGNELANOISSEFORPDOUGLAS.R MOO RET R NNDIA A STATE OF DEDATE SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURAL ELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THEBASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALLFURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET ADDENDUM 1 REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603211-01-2021 M500 MECHANICAL DETAILS AC RACK DETAIL NOT TO SCALE 01/31/22