Loading...
HomeMy WebLinkAboutP500 - PLUMBING DETAILS DWVFOR INSULATED PIPING) TO STRUCTURE 1 /2" HANGER ROD WHERE REQUIRED FIBERGLAS ONLY INSULATED PIPE METAL SHIELD FOR 20 GAUGE SHEET BARRIER (TYPICALCONTINUOUS VAPOR NUT (TYPICAL) HANGER PIPING STRAP THRU BOLT NOTES: REFER TO RELATED SECTIONS OF THE SPECIFICATIONS FOR INFORMATION REGARDING FLASHING MEMBRANE AND FIRESTOP SEALANT FINISH FLOOR LC PROVIDE NEW CONCRETE TO MATCH EXISTING FLOOR FLASHING MEMBRANE REMOVE EXISTING CONCRETE TO RECIEVE FLASHING CLAMP FIRESTOP SEALANT CORE HOLE TO RECIEVE DRAIN BODY FLOOR DRAIN BODY EXISTING SLAB FLOOR DRAIN GRATE TRAP SEAL TO GRADE DETAIL AT END OF LINECLEANOUT OCCURS 1 /8 BEND IF WASTE LINE LENGTH TO SUIT WASTE LINE 1 /8 BEND FINISHED GRADE HEAD WITH COUNTER SUNKBRASS CLEANOUT PLUGFLOOR LINE SAME AS CLEANOUTBALANCE OF PIPE 1 /8 BEND AREASFOR CARPETEDCARPET MARKER OF FLOORTO BE FLUSH WITH TOP COVER. TOP OF COVERCLEANOUT AND ACCESS CLEANOUT TO GRADEFLOOR CLEANOUT NOTE: FIRE SEALANTS AND PIPE PENETRATION SHALL HAVE AN F-RATING AND NO LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE WALL PENETRATED. SANITARY, DRAINAGE OR WATER PIPE NON-SECURE SPACESECURE SPACE PVC PIPE SLEEVE RATED CAULK. 1 /4" BEAD OF FIRE DISHWASHER LOOPED HIGH AND SECURELY FASTENED TO COUNTER OR WALL 2" FOOD-WASTE GRINDER 1 /2" TO FOOD WASTE GRINDER INLET OR 3 FT. ABOVE STRUCTURE. 1 0 FT. (MIN.) FROM ANY WALL VENT STACK OUTLET TO BE NOTE: ROOFING CONSTRUCTIONROOF FLASHING SLEEVE VENT STACK VENT STACK EXTENSIONHOLE IN WALL FINISH BY OTHERSWOOD OR STEEL FRAMING STUD SCREW MOUNTING BRACKET TO STUD WASH MACHINE SERVICE CONNECTION BOX OVERFLOW TRAY 2" WASTE OUTLET 1 /2" CW SUPPLY TOP OF BOX TOP OF MACHINE 3-1 /2" XX" TO FL. SHOCK ABSORBER TYPICAL SERVICE STOP NO SCALE A A REFER TO SPECIFICATIONS FOR ADDITIONAL SLEEVE REQUIREMENTS 1 8 GAUGE CONTINUOUS SHEET METAL ENCLOSURE FOR PENETRATIONS WITH FIRE-STOP MATERIAL. ENCLOSURE SHALL NOT BE ATTACHED TO PIPE OR INSULATION. SECTION A-A NO SCALE TOPPING SLAB (REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS) FOR PENETRATIONS IN FIRE-RATED FLOORS, FILL VOID, OR CAVITY WITH MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES INC. FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM OR U.L. CLASSIFIED THROUGH-PENETRATION FIRESTOP DEVICE 1 /4" TO 3/8" GAP BETWEEN PIPE AND CORE PIPE AND/OR CONDUIT 1 " TYP OUTSIDE SURFACE OF PIPE (OR INSULATION) 1 /4" TO 3/8" GAP BETWEEN EDGE OF ENCLOSURE AND PIPE SLEEVE UNDERSIDE PLAN VIEW HOT WATER BALL VALVE (TYP) DOMESTIC COLD WATER 1 05°F UNION (TYP) TEMPERED WATER 1 1 0°F THERMOSTATIC MIXING VALVE CONCRETE HOUSEKEEPING PADPROVIDE VIBRATION ISOLATION BETWEEN PACKAGE FRAME & HOUSEKEEPING PAD SUCTION HEADER CONTROL VALVE DISCHARGE HEADER CONTROL VALVE FLEXIBLE CONNECTION SUCTION HEADER (COPPER) DISCHARGE HEADER (COPPER) POWER CONTROL PANEL REFER TO DRAWINGS FOR SIZE CONDITIONS INSTALLED IN TIGHT HEADROOM FOR SINGLE PIPING TO BE THIS DETAIL ALSO APPLIES NOTE: PIPE (TYPICAL) (TYPICAL) ROD TO STRUCTURE 1 /2" ALL THREADED PIPE INSULATED OF PIPING (TYPICAL) AT BEARING SURFACE PLASTIC OR METAL SHIELD IRON STEEL ANGLE NON - INSULATED UNI STRUT CLAMPS MOORE ENGINEERING SERVICES, INC. 6340 LaPas Trail Indianapolis, IN 46268 Phone (317) 291-1052 FAX (317) 298-2729R I G EEIS PE60860351 No.REENIGNELANOISSEFORPDOUGLAS.R MOO RET R NNDIA A STATE OF DEDATE SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURAL ELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THEBASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALLFURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET ADDENDUM 1 REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603211-01-2021 P500 PLUMBING DETAILS - DWV 01/31/22