HomeMy WebLinkAboutP500 - PLUMBING DETAILS DWVFOR INSULATED PIPING)
TO STRUCTURE
1 /2" HANGER ROD
WHERE REQUIRED
FIBERGLAS
ONLY
INSULATED PIPE
METAL SHIELD FOR
20 GAUGE SHEET
BARRIER (TYPICALCONTINUOUS VAPOR
NUT (TYPICAL)
HANGER
PIPING
STRAP
THRU BOLT
NOTES:
REFER TO RELATED SECTIONS OF THE SPECIFICATIONS FOR INFORMATION REGARDING FLASHING MEMBRANE AND FIRESTOP
SEALANT
FINISH FLOOR
LC
PROVIDE NEW CONCRETE TO MATCH
EXISTING FLOOR
FLASHING MEMBRANE
REMOVE EXISTING CONCRETE
TO RECIEVE FLASHING CLAMP
FIRESTOP SEALANT
CORE HOLE TO RECIEVE
DRAIN BODY
FLOOR DRAIN BODY
EXISTING SLAB
FLOOR DRAIN GRATE
TRAP SEAL
TO GRADE DETAIL
AT END OF LINECLEANOUT OCCURS
1 /8 BEND IF
WASTE LINE
LENGTH TO SUIT WASTE LINE
1 /8 BEND
FINISHED GRADE HEAD
WITH COUNTER SUNKBRASS CLEANOUT PLUGFLOOR LINE
SAME AS CLEANOUTBALANCE OF PIPE
1 /8 BEND
AREASFOR CARPETEDCARPET MARKER
OF FLOORTO BE FLUSH WITH TOP
COVER. TOP OF COVERCLEANOUT AND ACCESS
CLEANOUT TO GRADEFLOOR CLEANOUT
NOTE:
FIRE SEALANTS AND PIPE
PENETRATION SHALL HAVE AN
F-RATING AND NO LESS THAN
THE REQUIRED FIRE RESISTANCE
RATING OF THE WALL
PENETRATED.
SANITARY, DRAINAGE
OR WATER PIPE
NON-SECURE SPACESECURE SPACE
PVC PIPE SLEEVE
RATED CAULK.
1 /4" BEAD OF FIRE
DISHWASHER
LOOPED HIGH AND SECURELY
FASTENED TO COUNTER OR WALL
2"
FOOD-WASTE
GRINDER
1 /2" TO FOOD
WASTE GRINDER INLET
OR 3 FT. ABOVE STRUCTURE.
1 0 FT. (MIN.) FROM ANY WALL
VENT STACK OUTLET TO BE
NOTE:
ROOFING CONSTRUCTIONROOF
FLASHING SLEEVE
VENT STACK
VENT STACK EXTENSIONHOLE IN WALL
FINISH BY OTHERSWOOD OR STEEL
FRAMING STUD
SCREW MOUNTING
BRACKET TO STUD
WASH MACHINE SERVICE
CONNECTION BOX
OVERFLOW TRAY
2" WASTE OUTLET 1 /2" CW SUPPLY
TOP OF BOX
TOP OF MACHINE
3-1 /2"
XX" TO FL.
SHOCK ABSORBER
TYPICAL SERVICE STOP
NO SCALE
A A
REFER TO SPECIFICATIONS FOR ADDITIONAL SLEEVE REQUIREMENTS
1 8 GAUGE CONTINUOUS SHEET METAL
ENCLOSURE FOR PENETRATIONS WITH
FIRE-STOP MATERIAL. ENCLOSURE
SHALL NOT BE ATTACHED TO PIPE OR
INSULATION.
SECTION A-A
NO SCALE
TOPPING SLAB (REFER TO THE ARCHITECTURAL
DRAWINGS FOR LOCATIONS)
FOR PENETRATIONS IN FIRE-RATED FLOORS, FILL VOID, OR
CAVITY WITH MATERIALS CLASSIFIED BY UNDERWRITERS
LABORATORIES INC. FOR USE IN THROUGH-PENETRATION
FIRESTOP SYSTEM OR U.L. CLASSIFIED
THROUGH-PENETRATION FIRESTOP DEVICE
1 /4" TO 3/8" GAP BETWEEN PIPE AND CORE
PIPE AND/OR CONDUIT
1 " TYP
OUTSIDE SURFACE
OF PIPE (OR
INSULATION)
1 /4" TO 3/8" GAP BETWEEN
EDGE OF
ENCLOSURE AND
PIPE
SLEEVE
UNDERSIDE PLAN VIEW
HOT WATER
BALL VALVE (TYP)
DOMESTIC COLD WATER
1 05°F
UNION (TYP)
TEMPERED WATER
1 1 0°F
THERMOSTATIC
MIXING VALVE
CONCRETE
HOUSEKEEPING
PADPROVIDE
VIBRATION
ISOLATION
BETWEEN
PACKAGE
FRAME
&
HOUSEKEEPING
PAD
SUCTION
HEADER
CONTROL
VALVE
DISCHARGE
HEADER
CONTROL
VALVE
FLEXIBLE CONNECTION
SUCTION
HEADER
(COPPER)
DISCHARGE
HEADER
(COPPER)
POWER CONTROL PANEL
REFER TO
DRAWINGS FOR SIZE
CONDITIONS
INSTALLED IN TIGHT HEADROOM
FOR SINGLE PIPING TO BE
THIS DETAIL ALSO APPLIES
NOTE:
PIPE (TYPICAL)
(TYPICAL)
ROD TO STRUCTURE
1 /2" ALL THREADED
PIPE
INSULATED
OF PIPING (TYPICAL)
AT BEARING SURFACE
PLASTIC OR METAL SHIELD
IRON
STEEL ANGLE
NON - INSULATED
UNI STRUT CLAMPS
MOORE ENGINEERING
SERVICES, INC.
6340 LaPas Trail
Indianapolis, IN 46268
Phone (317) 291-1052
FAX (317) 298-2729R
I
G EEIS
PE60860351
No.REENIGNELANOISSEFORPDOUGLAS.R MOO
RET R
NNDIA A
STATE OF DEDATE
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURAL
ELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT CECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THEBASIS OF THE GENERAL SCOPE INDIACATED OR
DESCRIBED, TRADE CONTRACTOR SHALLFURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
SHEET
ADDENDUM 1
REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603211-01-2021
P500
PLUMBING DETAILS -
DWV
01/31/22