Loading...
HomeMy WebLinkAboutS101.0 - Proposed Floor PlanN1'-4" 7'-8 5/8"HEADER (WINDOWS & DOORS): DOUBLE 2X8 DOUBLE TOP PLATE KING STUD CRIPPLE STUD BOTTOM PLATE O.C. 3/4" SUBFLOOR 2x8 CEILING JOISTS 2X10" FLOOR JOISTS @ 16" O.C. EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 FRAME NEW INTERIOR POCKET DOOR ROUGH OPENING PER DOOR SPECIFICATIONS. 1 PREP SUBFLOOR FOR FLUSH SHOWER PAN INSTALLATION. 1 FRAME DOUBLE WALL FOR PLUMBING TO BE LOCATED IN ATTIC. 1 FRAME DOUBLE WALL FOR NICHE AND PLUMBING. 1 FRAME SHOWER NICHE & BENCH PER TILE DETAIL DRAWINGS. INSTALL BLOCKING FOR SHOWER GLASS INSTALLATION. 1 INSTALL NEW SUBFLOOR AS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. 1 PROVIDE BLOCKING FOR CABINET INSTALLATION AND BATHROOM ACCESSORIES. F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRECAULK ALL MECHANICAL OPENINGS PER MUNICIPAL CODE REQUIREMENTS. 1 INSTALL NEW WALL/ATTIC INSULATION WHERE NECESSARY FROM DEMOLITION AND MECHANICAL ROUGH INS. FINAL SCOPE WILL BE DETERMINED ON A FIELD WALK FOLLOWING MECHANICAL ROUGH-IN PHASE. 1 INSTALL INSULATION IN ATTIC WALL ADJACENT TO SHOWER I1I1 I2I2 I3I3 I1I1 I2I2 I3I3 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 EXISTING DRYWALL FINISH NOTES; WALLS: SMOOTH-LEVEL 4; CEILINGS: TEXTURED 1 INSTALL NEW DRYWALL ON ALL CEILINGS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING CEILING FINISH IN HOME. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. 1 INSTALL NEW DRYWALL ON ALL NEWLY FRAMED WALLS. PATCH ALL AREAS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING DRYWALL FINISH. INCLUDE DRYWALL PATCH FOLLOWING COUNTERTOP. INSTALLATION. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. D1D1 D2D2 D3D3 D1D1 D2D2 D3D3 D01 FLOOR FLOOR R4 R4 AA BB 5'-10 1/2"8'-10 3/4"5'-3"2'-9"3'5'3'-10 1/4"15'-2"5'-8 3/4"9'-2 15/16" 2' CL 4'-2"CL 2'-6"1'-4"GFCIGFCIGFCICLOSET C.H.: 8'-0" TILE MASTER BATH C.H.: 8'-0" TILE ? F4F4 I3I3 F1F1 F5F5 ATTIC DIM T F3F3 F2F2 DOOR SCHEDULE NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER D01 2 1 58"X82 1/2" 80" 28 " 80 "POCKET-DOOR P07 HOY RESIDENCEMaster Bath Renovation1413 Stoney Creek CircleCarmel, IN 46032Date:Revision: A3 SHEET OF 7 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/31/2022 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Order during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. PROPOSED FLOOR PLAN SCALE: 3/4" = 1' TYPICAL FRAMING DETAIL SCALE: 3/8" = 1' 0" DESIGNER: TRACY WOLFEE: tracy@customlivingusa.comC: 317.379.943802/04/22