HomeMy WebLinkAboutS101.0 - Proposed Floor PlanN1'-4" 7'-8 5/8"HEADER (WINDOWS & DOORS):
DOUBLE 2X8
DOUBLE TOP PLATE
KING STUD
CRIPPLE STUD
BOTTOM PLATE
O.C.
3/4" SUBFLOOR
2x8 CEILING JOISTS
2X10" FLOOR JOISTS
@ 16" O.C.
EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
FRAMING PLAN NOTES
NOTE QTY DESCRIPTION
1 FRAME NEW INTERIOR POCKET DOOR ROUGH OPENING
PER DOOR SPECIFICATIONS.
1 PREP SUBFLOOR FOR FLUSH SHOWER PAN INSTALLATION.
1 FRAME DOUBLE WALL FOR PLUMBING TO BE LOCATED IN
ATTIC.
1 FRAME DOUBLE WALL FOR NICHE AND PLUMBING.
1
FRAME SHOWER NICHE & BENCH PER TILE DETAIL
DRAWINGS. INSTALL BLOCKING FOR SHOWER GLASS
INSTALLATION.
1
INSTALL NEW SUBFLOOR AS NECESSARY FROM DEMO AND
MECHANICAL ROUGH INS. FINAL SCOPE TO BE
DETERMINED FOLLOWING MECHANICAL ROUGH INS.
1 PROVIDE BLOCKING FOR CABINET INSTALLATION AND
BATHROOM ACCESSORIES.
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
F7F7
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
F7F7
INSULATION PLAN NOTES
NOTE QTY DESCRIPTION
1 FOAM AND FIRECAULK ALL MECHANICAL OPENINGS PER
MUNICIPAL CODE REQUIREMENTS.
1
INSTALL NEW WALL/ATTIC INSULATION WHERE NECESSARY
FROM DEMOLITION AND MECHANICAL ROUGH INS. FINAL
SCOPE WILL BE DETERMINED ON A FIELD WALK
FOLLOWING MECHANICAL ROUGH-IN PHASE.
1 INSTALL INSULATION IN ATTIC WALL ADJACENT TO
SHOWER
I1I1
I2I2
I3I3
I1I1
I2I2
I3I3
DRYWALL PLAN NOTES
NOTE QTY DESCRIPTION
1 EXISTING DRYWALL FINISH NOTES; WALLS: SMOOTH-LEVEL
4; CEILINGS: TEXTURED
1
INSTALL NEW DRYWALL ON ALL CEILINGS NECESSARY
FROM DEMO AND MECHANICAL ROUGH INS. MATCH
EXISTING CEILING FINISH IN HOME. FINAL SCOPE TO BE
DETERMINED FOLLOWING MECHANICAL ROUGH INS.
1
INSTALL NEW DRYWALL ON ALL NEWLY FRAMED WALLS.
PATCH ALL AREAS NECESSARY FROM DEMO AND
MECHANICAL ROUGH INS. MATCH EXISTING DRYWALL
FINISH. INCLUDE DRYWALL PATCH FOLLOWING
COUNTERTOP. INSTALLATION. FINAL SCOPE TO BE
DETERMINED FOLLOWING MECHANICAL ROUGH INS.
D1D1
D2D2
D3D3
D1D1
D2D2
D3D3
D01
FLOOR
FLOOR
R4
R4
AA
BB
5'-10 1/2"8'-10 3/4"5'-3"2'-9"3'5'3'-10 1/4"15'-2"5'-8 3/4"9'-2 15/16"
2'
CL 4'-2"CL 2'-6"1'-4"GFCIGFCIGFCICLOSET
C.H.: 8'-0"
TILE
MASTER BATH
C.H.: 8'-0"
TILE
?
F4F4
I3I3
F1F1
F5F5
ATTIC
DIM T
F3F3
F2F2
DOOR SCHEDULE
NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER
D01 2 1 58"X82 1/2" 80" 28 " 80 "POCKET-DOOR P07 HOY RESIDENCEMaster Bath Renovation1413 Stoney Creek CircleCarmel, IN 46032Date:Revision:
A3
SHEET OF 7
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/31/2022
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL PROPOSED PLAN NOTES
Framing contractors are responsible for all labor,
for the scope of work specified on the drawings
provided by Custom Living.
Owner understands that Custom Living has only
provided a labor and material allowance for the
scope of Rough Carpentry work specified on the
drawings. Any additional work added or
uncovered during this scope will be filed as a
Change Order during construction
Owner understands that the drywall allowance is
based on an estimated board count and square
footage take-off. A final walk through with a
drywall contractor after framing and mechanical
rough-ins will be necessary to finalize drywall
installation and finish budgets.
Final drywall touch-ups will follow countertop
installation.
PROPOSED FLOOR PLAN
SCALE: 3/4" = 1'
TYPICAL FRAMING DETAIL
SCALE: 3/8" = 1' 0" DESIGNER: TRACY WOLFEE: tracy@customlivingusa.comC: 317.379.943802/04/22