Loading...
HomeMy WebLinkAboutM101.0 - Proposed MEP Plan4" 3000K MODEL NO. JUNO-4RLD G3 09LM 30K 90CRI 120 FRPC WWH M6 DUPLEX WHITE LUTRON TOGGLE DIMMER SWITCH WHITE TIMER SWITCH - WHITE TOGGLE SWITCH WHITE REFRIGERATOR OUTLET MICROWAVE OUTLET DISHWASHER POWER SUPPLY HOOD VENT POWER SUPPLY GARBAGE DISPOSAL POWER SUPPLY COOKTOP POWER SUPPLY CLOTHES DRYER OUTLET CLOTHES WASHER OUTLET 110V OUTLET 220/240V OUTLET GFCI OUTLET OUTDOOR OUTLET LOW VOLTAGE TRANSFORMER SINGLE POLE SWITCH DIMMER SWITCH 3-WAY SWITCH 4-WAY SWITCH GD WALL SWITCH GD COUNTERTOP AIR SWITCH LOW VOLTAGE LIGHTING SWITCH TIMER SWITCH OCCUPANCY SWITCH SURFACE MOUNT LIGHT FIXTURE 4" RECESSED CAN LIGHT 6" RECESSED CAN LIGHT 6" RECESSED CAN/FAN UNIT EXHAUST FAN ONLY EXHAUST FAN W/ LIGHT WALL MOUNTED SCONCE / LIGHT CEILING FAN LOW VOLTAGE LIGHT SMOKE DETECTOR CARBON MONOXIDE DETECTOR SMOKE/CARBON MONOXIDE MOTION SENSOR CEILING SPEAKER GAS SHUT-OFF KEY MAIN WATER SHUT-OFF LAUNDRY BOX FROST PROOF HOSE BIB CLEAN OUT TILE-IN DRAIN FLOOR DRAIN COLD AIR RETURN FLOOR FLOOR SUPPLY REGISTER CEILING CEILING SUPPLY REGISTER WALL WALL SUPPLY REGISTER EXTERIOR WALL EXHAUST VENT T THERMOSTAT DRYER BOX ELECTRICAL KEY PLUMBING KEY HVAC KEY FLOOR FLOOR R4 R4 R4 6" CL 1'-6" CL 3'-8 1/2"CL 1'-9 1/2"CL 1'-6"GFCIGFCIGFCICLOSET C.H.: 8'-0" TILE MASTER BATH C.H.: 8'-0" TILE ? ATTIC P1P1 E6E6 E4E4 E7E7 E10E10 E8E8 E5E5 E11E11 E9E9 E5E5 E11E11E11E11 P2P2 P3P3 H1H1 T DIM PROPOSED HVAC PLAN NOTES NOTE QTY DESCRIPTION 1 PROVIDE FINAL HOOKUP FOR VENTING OF NEW EXHAUST FAN. H1H1H1H1 PROPOSED ELECTRICAL PLAN NOTES NOTE QTY DESCRIPTION 1 ELECTRICIAN TO VERIFY EXISTING SMOKE AND CO DETECTORS MEET CURRENT CODE REQUIREMENTS. IF THE HOME NEEDS TO BE UPDATED TO MEET CODE, THERE WILL BE AN ADDITIONAL COST. 1 ELECTRICIAN TO VERIFY ALL GFCI PROTECTED CIRCUITS MEET CURRENT CODE REQUIREMENTS. 1 PULL & REPLACE EXISTING SWITCHES WITH NEW DEVICES TO MATCH NEW DEVICE STYLE. ALL NEW DEVICES TO BE STANDARD SWITCHES UNLESS NOTED OTHERWISE. 1 REWIRE EXISTING 3-BANK AS SHOWN. INSTALL (1) TIMER, (1) TOGGLE, (1) DIMMER SWITCH 2 PROVIDE ROUGH IN AND FINISH FOR (2) VANITY BAR LIGHTS IN LOCATION SHOWN. FINAL HEIGHT OF FIXTURE TO BE DETERMINED ON SITE DURING ROUGH IN PHASE. 1 PROVIDE ROUGH IN AND FINISH FOR (2) 4" LED RECESSED CANS IN LOCATIONS AS SHOWN. 1 PROVIDE ROUGH IN AND FINISH FOR (1) 4" LED WET-RATED RECESSED CAN IN LOCATION AS SHOWN. 1 PULL & REPLACE, PROVIDE FINISH FOR (2) FLUSH MOUNT LIGHTS IN EXISTING LOCATION AS SHOWN. 1 PROVIDE FINISH FOR (1) PANASONIC FAN/LIGHT UNIT IN EXISTING LOCATION. BULB TO MATCH LED TRIM TEMPERATURE AS SHOWN. 1 PROVIDE ROUGH IN AND FINISH FOR (1) PANASONIC FAN UNIT (NO LIGHT). 3 PROVIDE ROUGH IN AND FINISH FOR GFCI OUTLETS IN NEW LOCATIONS AS SHOWN. DEVICE STYLE AND COLOR SHOWN. ALL OUTLETS TO BE STANDARD HEIGHT U.N.O.; ALL DEVICES TO BE STANDARD OUTLETS U.N.O.. E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E7E7 E8E8 E9E9 E10E10 E11E11 E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E7E7 E8E8 E9E9 E10E10 E11E11 PROPOSED PLUMBING PLAN NOTES NOTE QTY DESCRIPTION 1 PROVIDE FINISH FOR (2) NEW VANITY SINKS AND NEW FAUCETS IN EXISTING LOCATION AS SHOWN. 1 PROVIDE FINISH FOR NEW TOILET IN EXISTING LOCATION AS SHOWN. 1 PROVIDE ROUGH IN AND FINISH FOR THE FOLLOWING SHOWER FIXTURES: (1) SHOWER HEADS, (1) SHOWER WAND ON SLIDE BAR, (1) THERMOSTATIC VALVE, (1) VOLUME CONTROL VALVE, (1) SHOWER DRAIN [WEDI PAN]. SEE TILE DETAILS FOR LOCATIONS. P1P1 P2P2 P3P3 P1P1 P2P2 P3P3 NHOY RESIDENCEMaster Bath Renovation1413 Stoney Creek CircleCarmel, IN 46032Date:Revision: A4 SHEET OF 7 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/31/2022 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] PROPOSED M.E.P. PLAN SCALE: 3/4" = 1' NEW OUTLET DEVICE STYLE NEW SWITCH DEVICE STYLE RECESSED CAN LIGHTS DESIGNER: TRACY WOLFEE: tracy@customlivingusa.comC: 317.379.9438DECORATIVE FIXTURES TBD VANITY LIGHTS - E5 TBD CLOSET LIGHTS - E8 GENERAL M.E.P NOTES HVAC Contractor is responsible for engineering calculation necessary for correct sizing of new equipment and ductwork being supplied, fabricated and installed for the project. HVAC ductwork installed in unconditioned areas to be insulated and sealed per Building Code Standards. HVAC contractor to start, test, and balance any new equipment and ductwork to assure proper operation of new systems. Final plumbing materials selected may have an affect on the final Plumbing Material and Installation Budgets. Owners understand that if additional plumbing, electrical or ductwork is found in walls being deleted that is not included on the plans there will be a Change Order during construction to relocate as necessary. Owners understand that during mechanical rough-ins there will be times when the water service will be shut off to areas in the home. Plumbing and Lighting fixtures supplied by Owner will not be warranted by Custom Living Plumbing and Lighting fixtures supplied by Owner must be selected and on-site prior to start of mechanical rough-ins. 02/04/22