HomeMy WebLinkAboutS100.0 - Existing Floor PlanNEXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
FLOORFLOOR
5'-10 1/2"5'-3"2'-9"4'-3"
3 1/2"8'-10 3/4"2'-4"6'-11"
10'-10 1/2"3'-1"2'-6"
2'
6'-3 1/2"
GFCI
CLOSET
C.H. 8'-0"
CARPET
C.H. 8'-0"
TILE
MASTER BATH
ATTIC
D5D5D3D3
D9D9
D2D2
D8D8
D11D11
D12D12
E7E7
E6E6
E4E4
P2P2
H2H2
E3E3
E5E5
D4D4
D7D7
D6D6
P3P3
P4P4
P5P5
D10D10
DEMO & PREP PLAN NOTES
NOTE QTY DESCRIPTION
1
INSTALL FLOOR PROTECTION FROM DOOR TO BE USED AS
CONSTRUCTION ENTRANCE TO LOCATIONS OF REMODEL.
INSTALL PLASTIC SHEATHING AND ZIPPER WALL AT MASTER
BEDROOM DOOR AND AT MASTER BATHROOM DOOR.
1
DEMO INTERIOR CLOSET DOOR SLAB, CASING JAMB & ALL
HARDWARE. SAVE DOOR SLAB TO BE REPURPOSED AS
POCKET DOOR. TRIM AND HARDWARE TO BE TRASHED.
1
DEMO SHOWER SURROUND DOWN TO STUDS (TRASH). DEMO
ALL SHOWER FIXTURES (TRASH). DEMO SHOWER PAN DOWN
TO SUBFLOOR (TRASH).
1 DEMO JETTED TUB AND TUB DECK (TRASH).
1 REMOVE ALL EXISTING CABINETS & COUNTERTOPS IN
MASTER BATH (TRASH). DO NOT REMOVE CLOSET SHELVING.
1 REMOVE WALL MIRROR (TRASH).
1 REMOVE SLANTED SHOE BOARD AT BASE IN CLOSET (TRASH).
1 REMOVE ALL SHOE MOLDING AND BASEBOARD (TRASH).
1 DEMO TILE DOWN TO SUBFLOOR.
1 DEMO CARPET AND CARPET PAD DOWN TO SUBFLOOR.
1 DEMO NON LOAD BEARING INTERIOR WALLS AS SHOWN
1 DEMO EXISTING FRAMING NECESSARY FOR FRAMING OF NEW
POCKET DOOR OPENING.
1 REMOVE SUBFLOOR NECESSARY FOR MECHANICAL ROUGH
INS.
1 REMOVE DRYWALL NECESSARY FOR FRAMING OR
MECHANICAL ROUGH INS IN PROPOSED PLAN.
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
D7D7
D8D8
D9D9
D10D10
D11D11
D12D12
D13D13
D14D14
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
D7D7
D8D8
D9D9
D10D10
D11D11
D12D12
D13D13
D14D14
PLUMBING DEMO/DISCONNECT PLAN NOTES
NOTE QTY DESCRIPTION
1 SEPARATE PLUMBING PERMIT NOT REQUIRED.
1
DISCONNECT AND REMOVE EXISTING TOILET (TRASH) & CAP
LINES PRIOR TO DEMOLITION. NEW TOILET TO BE INSTALLED
IN EXISTING LOCATION ON FINISH.
1
DISCONNECT VANITY SINKS PRIOR TO DEMOLITION & CAP
LINES. NEW SINKS AND FAUCETS TO BE INSTALLED IN
EXISTING LOCATION ON FINISH.
1
DISCONNECT ALL SHOWER FIXTURES PRIOR TO DEMOLITION
AND CAP LINES IN FLOOR. NEW SHOWER LOCATION TO USE
EXISTING TUB SUPPLY AND DRAIN LINES.
1
DISCONNECT WHIRLPOOL TUB AND FAUCET PRIOR TO
DEMOLITION. CAP LINES. EXISTING LINES TO BE USED FOR
PROPOSED SHOWER LOCATION.
P1P1
P2P2
P3P3
P4P4
P5P5
P1P1
P2P2
P3P3
P4P4
P5P5
ELECTRICAL DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE ELECTRICAL PERMIT NOT REQUIRED.
1 DISCONNECT EXISTING ELECTRICAL IN WALLS TO BE DELETED
PRIOR TO DEMOLITION
1
REMOVE EXISTING VANITY FIXTURE (TRASH) PRIOR TO
DEMOLITION. NEW FIXTURES TO BE INSTALLED IN NEW
LOCATION AS SHOWN ON PROPOSED MEP PLAN.
1
REMOVE EXISTING EXHAUST FAN/LIGHT UNIT PRIOR TO
DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN NEW
LOCATION AS SHOWN ON PROPOSED MEP PLAN.
1
REMOVE EXISTING EXHAUST FAN/LIGHT UNIT PRIOR TO
DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN
SAME LOCATION ON FINISH.
1
REMOVE EXISTING (2) CLOSET FIXTURES PRIOR TO
DEMOLITION (TRASH). NEW FIXTURES TO BE INSTALLED IN
SAME LOCATION ON FINISH.
1 REMOVE LIGHT FIXTURE PRIOR TO DEMOLITION (TRASH).
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
HVAC DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE HVAC PERMIT NOT REQUIRED.
1 DELETE EXISTING FLOOR VENT. PAN OFF SUPPLY WHERE
ACCESSIBLE.
1 VERIFY EXISTING BATH FIXTURES ARE VENTED TO EXTERIOR.
H1H1
H2H2
H3H3
H1H1
H2H2
H3H3
GENERAL NOTES
NOTE QTY DESCRIPTION
1 DUMPSTER AND PORTALET LOCATIONS TO BE
DETERMINED ON SITE W/ HOMEOWNERS
1
HOMEOWNERS TO CLEAR OUT SPACE IN GARAGE FOR
STORAGE OF BUILDING MATERIALS PRIOR TO START OF
WORK.
GN1GN1
GN2GN2
GN1GN1
GN2GN2 HOY RESIDENCEMaster Bath Renovation1413 Stoney Creek CircleCarmel, IN 46032Date:Revision:
A2
SHEET OF 7
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/31/2022
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL SITE PREP & DEMO NOTES
Install plastic to seal off areas being remodeled
from rest of home as necessary.
Install floor covering for construction path from
door designated as the construction entrance to
locations of remodeling as necessary.
Install additional floor covering or wall protection
as needed over areas close to the areas of
construction activity.
Install dust control measures on HVAC cold air
returns located within the locations of
remodeling.
Custom Living can provide a HEPA Air Scrubber
to aid in airborne dust control from the start of
demolition up to priming of new drywall
depending on site conditions. Homeowner
understands that this will help to reduce airborne
dust; however, it will not mitigate it in its entirety.
Demolition Contractor(s) are responsible for all
labor, for the scope of work specified in the
drawings provided by Custom Living.
Homeowner understands that Custom Living has
only provided a labor and material allowance for
the scope of demolition denoted on the
drawings. Any additional scope added or
uncovered during demolition result in filing a
Change Order during construction.
Homeowners understand that demolition work
will generate dust and noise throughout the
house. Custom Living will provide site protection
measures to reduce where possible, but
Homeowners should not expect 100%
containment.
EXISTING / DEMO PLAN
SCALE: 3/4" = 1'DESIGNER: TRACY WOLFEE: tracy@customlivingusa.comC: 317.379.943802/04/22