Loading...
HomeMy WebLinkAboutA4.01 Roof Plan8:12 8:12 8:12 4:12 8:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 4:12 MIN. 203 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D" "A" 2501ROOF AREA: SQ. FT.PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;1'-0"\PTYP. \A1;7'-9" \A1;6'-4{\H0.75x;\S1#2;}" \A1;5'-0"10:12 "C" 195ROOF AREA: SQ. FT. \A1;4'-0" 10:12 \A1;18'-0" POT VENTS \A1;6'-0" \A1;4'-0" \A1;4'-0"ROOF AREA "C"SQ FTG195AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.260.330.4243.2610AT EAVE0.390.330.5656.7408.00TOTAL (MIN)0.650.650.98100.003 HIGH -RIDGE VENT0.260.330.5047.37004.00AT EAVE0.390.330.5652.6308.00TOTAL (MIN)0.650.651.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEELEVATION NC2GATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2501AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.334.174.2449.59100AT EAVE5.004.174.3150.41062.00TOTAL (MIN)8.348.348.54100.003 HIGH -RIDGE VENT3.334.174.0047.760032.00AT EAVE5.004.174.3852.24063.00TOTAL (MIN)8.348.348.38100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE"B"572ROOF AREA:SQ. FT.GUTTER AND DOWNSPOUTS4:124:124:12ROOF AREA "B"SQ FTG572AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.760.950.8543.2620AT EAVE1.140.951.1156.74016.00TOTAL (MIN)1.911.911.96100.003 HIGH -RIDGE VENT0.760.950.00#####000.00AT EAVE1.140.950.00#####00.00TOTAL (MIN)1.911.910.00######ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEA4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Rockwall 2054.300Home for * Market Home *, 7231-020002836 Trailblazer Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 02/04/22