HomeMy WebLinkAboutA106 - FLOOR FINISH PLANDN
UP
1.4
1.41
1 2
2
2.1
2.1
2.5
2.5
3
3
3.5
3.5 3.9
4
4
5
5
5.4
5.4
6
6
4.4
B B
C C
D D
E E
F F
G G
A A
Z
Y
FLORAL
PREP
315
F2
FLORAL
COOLER
316
F2
PRODUCE
COOLER
314
F2
PRODUCE
PREP
313
F2
KITCHEN
312
F2
COLD
COOKED
PREP
311
F2
SCULLERY
309
F2
COLD
COOKED
COOLER
310
F2
MEAT &
SEAFOOD
PREP
304
F2
MEAT &
SEAFOOD
COOLER
303
F2
BAKERY
PREP
302
F2
DAIRY
COOLER
300
F2
BREAK
ROOM
405
F1
WELLNESS
ROOM
406
F1
RESTROOM
407
F2
RESTROOM
408
F2
BULK
COOLER
305
F2
ICE CREAM
FREEZER
306
F6
BAKERY
DELI
GROCERY
FREEZER
307
F6
MEAT &
SEAFOOD
FREEZER
308
F6
DAIRY
SALES
111
F1
GROCERY
SALES
109
F1
FROZEN
SALES
110
F1
BEER AND
WINE SALES
107
F1
BAKERY
SERVICE
AISLE
112
F1
DELI PREP
202
F2
FRONT END
CHECKOUT
AREA
101
F1
FLORAL
SALES
114
F1
PRODUCE
SALES
113
F1
MEAT
SERVICE
AISLE
203
F2
BULK/COFFEE/CANDY
SALES
108
F1
INSTACART
404
F1
MEN'S R.R.
402
F2
WOMEN'S
R.R.
401
F2
OFFICE
400
F1
FIRE RISER
503
F5
RECEIVING
502
F5
BOH
CORRIDOOR
504
F5
BOH
500
F5
7'-0"41'-0 1/2"22'-7 1/2"ELECTRICAL
ROOM
501
ETR
BAKERY
COOLER
301
F2
CLOSET
403
F1
ENTRY/EXIT
VESTIBULE
100
F1
TR8 TR8
TR4
TR3TR3
TR8
TR4
TR7
TR7
TR7
TR7
TR7
TR7TR7TR4
TR4 TR5 TR5 TR5TR2
TR8TR8TR2
TR2
TR2
TR3
15'-0"TR3
RESTROOM
COORIDOR
409
F1
4
4 4
4
4
4
4
4
4
4
TR10
6
4
R 4' - 2 1/4"R 3' - 3 1/2"R 3' - 7 1/2"R 3' - 4 1/4"
12'-4 1/2" 9'-2 1/2"13'-0"17'-4"9"4'-4 1/2"26'-2"
TR9
MOP SINK
414
F9
3
IT
413
F5
F11
F11
F11
5'-1" 21'-3 1/2" 10'-2 1/2" 3'-2"3'-2"10'-2 1/2"17'-7"3'-2"31'-6"27'-9 1/2"F4
4
4
4
8' - 1"
FLOORING TRANSITION
TO BE UNDER CASES.
TR11
TR11
TR11TR11
TR11
UP
SLOPE CONCRETE
TR9
LEGEND
F1
F2
F3
F4
F5
F6
LUXURY VINYL TILE 121.9 cm x 18.4 cm
FORMAT -RUNNING BOND
QUARRY TILE
WALK-OFF MAT
SEALED
CONCRETE
SEALED CONCRETE
(NON -SLIP)
F7 NOT USED
F8 NOT USED
F9
RESINOUS
FLOORING
F10 NOT USED
F11
NOT USED
LUXURY VINYL TILE 121.9 cm x 18.4 cm
FORMAT - RUNNING BOND
F1/F11
BUTT TILE
TOGETHER F2
F1/F11
THRESHOLD T2 SET IN FULL BEAD OF
CAULK AND SCREWED TO CONCRETE.
REFER TO MATERIAL FINISH SCHEDULE
ON SHEET A600
FREEZER WALL BEYOND
1/4"X4" SLEEVE ANCHORS.(4)
PER OPENING
THRESHOLD BY COOLER
VENDOR
TRANSITION DETAILS
TRANSITION
DETAILTR-3
TRANSITION
DETAILTR-2
NOT USEDTR-1
TRANSITION
DETAILTR-5
NOT USEDTR-6
TRANSITION
DETAILTR-4
TRENCH DRAIN,
REF TO DETAIL 6-
P502
FACE OF COOLER
BOX
F2/F5
PLATE ON TOP OF
COOLER PANEL
DOOR OPENING.
NOTE:
SEE PLUMBING DWG'S
FOR TRENCH GRATING
DEPTH
F2
TRANSITION
DETAILTR-8
F2
THRESHOLD T1 SET IN FULL
BEAD OF CAULK AND
SCREWED TO CONCRETE
SLAB. REFER TO MATERIAL
FINISH SCHEDULE ON
SHEET A600
TRANSITION
DETAILTR-9
THRESHOLD G.C. REFERENCE
DOOR SCEDULE.
TRANSITION
DETAILTR-10
F5
4"
REF PLUMBING FOR
TRENCH DRAIN
SECTION THRU
OUTLET
STEP BACK FOOTING
AROUND TRENCH
DRAIN OUTLET COOLER WALL
W1 APPLIED TO
COOLER. REFER TO
PARTITION DETAILS
F2
INSIDE OF
COOLER
INTEGRAL B2
BASE AS
SCHEDULED
TRANSITION
DETAILTR-11
SLOPE SLAB
TO TRENCH
CONCRETE SLAB
MAX1/2"TRANSITION
DETAILTR-7
THRESHOLD T1 SET IN FULL
BEAD OF CAULK AND SCREWED
TO CONCRETE SLAB. REFER TO
MATERIAL FINISH SCHEDULE ON
SHEET A600
F1
F2
THRESHOLD T1 SET IN
FULL BEAD OF CAULK
AND SCREWED TO
CONCRETE SLAB. REFER
TO MATERIAL FINISH
SCHEDULE ON SHEET
A600
SHEET NOTES
1. IN CONJUNCTION WITH THEIR TRADE SPECIFIC DRAWINGS,
CONTRACTOR IS TO REFER TO RESPONSIBILITY SCHEDULE ON
G001 FOR CLARIFICATION OF SCOPE THAT NEEDS TO BE
COORDINATED WITH OTHER TRADES.
2. ALL DIMENSIONS ARE TAKEN FROM STUD UNLESS NOTED
OTHERWISE.
3. FIELD VERIFY ALL DIMENSIONS.
4. NOT USED.
5. COMPLY WITH ALL MANUFACTURERS' RECOMMENDATIONS FOR
SURFACE PREPARATION, MIXING INSTRUCTIONS, APPLICATION
TECHNIQUES, ETC.
6. ALL EXPOSED CONCRETE SLAB AREAS TO BE SEALED. REFER
TO SPECIFICATIONS. COORDINATE TIMING WITH TFM PM.
7. CONDUIT AND PIPE PENETRATIONS THROUGH FLOOR TILES
ARE TO BE NEAT AND TIGHT.
8. EXTERIOR DOORS AND VESTIBULES AND THEIR THRESHOLDS
ARE FURNISHED AND INSTALLED BY G.C. INTERIOR THRESHOLD
PROVIDED AND INSTALLED BY TFM FLOORING/TILE VENDOR.
9. REFER TO MEP AND STRUCTURAL SLAB PLAN FOR LOCATION
OF ALL FLOOR DRAINS, FLOOR SINKS, REFRIGERATION PITS.
10. USE EPOXY BONDING MORTAR AT ALL WALL TILE AND QUARRY
TILE BASES AT PREP/COOLER/FREEZER BOXES.
11. NOT USED.
12. MAXIMUM VARIATION IN THE CONCRETE SLAB IS 1/8" IN 10 FEET
FROM REQUIRED PLANE, WITH NO MORE THAN 1/16" VARIATION
IN 24 INCHES WHEN MEASURED FROM THE HIGH POINTS IN THE
SURFACE.
13. PROVIDE INDUSTRY STANDARD MOISTURE TEST ON ANY NEW
SLAB-ON-GRADE OR ELEVATED SLABS SEVEN TO TEN DAYS
PRIOR TO TFM'S FLOORING FINISHES INSTALLATION.
14. REFERENCE A105 FOR SLOPING FLOORS.
KEYED NOTES
NOT USED.
CONTROL JOINT
RESINOUS FLOORING FINISH. EXTEND RESINOUS FINISH
6" VERTICALLY AT EACH WALL.
ALL WALL TILE AND QUARRY TILE BASE AT
PREP/COOLER/FREEZER BOXES TO USE EPOXY BONDING
MORTAR.
FLOOR DRAIN; REFER TO PLUMBING DRAWINGS FOR
SPECIFICATION AND LOCATION.
PROVIDE GROUT LINE AT TRANSITIONS UNDER
EQUIPMENT, TYP.
FLOOR SINK; REFER TO PLUMBING DRAWINGS FOR
SPECIFICATION AND LOCATION.
1
2
3
4
5
6
7
PROJECT NORTH SHEET NO.
This drawing was prepared for use on a
specific site contemporaneously with its issue
date and it is not suitable for use on a
different project site or at a later time. Use of
this drawing for reference or example on
another project requires the services of
properly licensed architects and engineers.
Reproduction of this drawing for reuse on
another project is not authorized and may be
contrary to the law.
BRR Original printed on recycled paper
COPYRIGHT NOTICE
CONSULTANT
PROJECT NO.
SHEET TITLE
ISSUES & REVISIONS
CONSULTANT LOGO
DRAWN BY: REBECCA BEASLEY
PROFESSIONAL SEAL
PROJECT MANAGER: DAN VON SEGGERN
DOCUMENT DATE:
CHECKED BY: JOHN SCHWEIGER
PROJECT NAME
PROJECT ADDRESS
TREVOR TYSON HOLCOMB
ARCHITECT
AR11800234
ARCHITECT OF RECORD:
TREVOR TYSON HOLCOMB
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
12/7/2021 12:17:48 PMFLOOR FINISH
PLAN
A106
62930563
12/07/21
THE FRESH
MARKET
1392 S. RANGELINE
ROAD
CARMEL, IN 46032
1/8" = 1'-0"1 FINISH FLOOR PLAN
NO. DATE DESCRIPTION
02/07/22