Loading...
HomeMy WebLinkAboutA108 - VALANCE CEILING PLAN1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B B C C D D E E F F G G A A Z Y FRONT END CHECKOUT AREA 101 C1 OTS FLORAL SALES 114 C1 OTS MEAT SERVICE AISLE 203 C3 9'-6" BAKERY SERVICE AISLE 112 C3 9'-6" DELI PREP 202 C8 11'-0" FLORAL COOLER 316 C4 10'-0" FLORAL PREP 315 C3 9'-6" B.O. HEADER @ 10'-6" B.O. HEADER @ 8'-6" B.O. HEADER @ 8'-6" B.O. HEADER @ 8'-6" 1 A109 _______ 3 A109 _______ 4 A109 _______2' - 3"8' - 0"8' - 0"8' - 0"8' - 0"2' - 3"1000S200-54 (CONTINUOUS)DELI VALANCE : 100 PLFTYP.TYP.4'-2"4'-2 1/2"12'-4 1/2"2 A109 _______1'-6"8 '-0"8'-0"1'-6"TYP.TYP.2 A501 _______ WAVE CEILING FURNISHED AND INSTALLED BY TFM DECOR VENDOR 45.00 ° 1 TYP. 4 5 6 7 2 3 TYP. TYP.4' - 9 3/4"23' - 9 3/8" 10' - 7 1/2"23' - 9 7/8"1' - 0"5' - 9"23' - 2 3/8" 10' - 9 1/8" 89' - 5"3' - 10"6' - 2 1/2"10' - 6"8' - 9 3/4"4' - 2 1/4"5 A109 _______ HATCHED AREA INDICATES STRUCTURAL FRAMING. REFERENCE STRUCTURAL SECTIONS. PROJECT NORTH SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE CONSULTANT PROJECT NO. SHEET TITLE ISSUES & REVISIONS CONSULTANT LOGO DRAWN BY: REBECCA BEASLEY PROFESSIONAL SEAL PROJECT MANAGER: DAN VON SEGGERN DOCUMENT DATE: CHECKED BY: JOHN SCHWEIGER PROJECT NAME PROJECT ADDRESS ARCHITECT DISCIPLINE LICENSE NUMBER 12/7/2021 12:18:00 PMVALANCE CEILING PLAN A108 62930563 12/07/21 THE FRESH MARKET 1392 S. RANGELINE ROAD CARMEL, IN 46032 1/8" = 1'-0"1 VALANCE CEILING PLANS 1. IN CONJUNCTION WITH THEIR TRADE SPECIFIC DRAWINGS, CONTRACTOR IS TO REFER TO RESPONSIBILITY SCHEDULE ON G001 FOR CLARIFICATION OF SCOPE THAT NEEDS TO BE COORDINATED WITH OTHER TRADES. 2. REFER TO DETAILS FOR JOIST REINFORCEMENT ANGLES AS REQUIRED. CONTRACTOR TO CONFIRM LOCATIONS AND REPORT DISCREPANCIES / DEFICIENCIES TO ARCHITECT IMMEDIATELY. 3. VERIFY CONDITIONS AND REPORT ALL DISCREPANCIES TO ARCHITECT IMMEDIATELY. 4. BRACE WALLS IN DIRECTION OPPOSITE OF CUSTOMER VIEW. GENERAL NOTES 1. IN CONJUNCTION WITH THEIR TRADE SPECIFIC DRAWINGS, CONTRACTOR IS TO REFER TO RESPONSIBILITY SCHEDULE ON G001 FOR CLARIFICATION OF SCOPE THAT NEEDS TO BE COORDINATED WITHOTHER TRADES. PROVIDE UNISTRUT SUPPORTS AS REQUIRED TO SUPPORT SUSPENDED LIGHTING GRIDS, SUSPENDED CEILING, REFRIGERATION UNITS, ETC. PAINT ANY UNISTRUT OR SUPPORT TO MATCH COLOR OF STRUCTURE ABOVE. CONNECTIONS TO BAR JOISTS ABOVE SHALL BE MADE AT PANEL POINTS. 2. COMPLY WITH SPECIAL REQUIREMENTS OF THE CODE WHICH PERTAIN TO THE SEISMIC REQUIREMENTS OF THIS PROJECT.. 3. REFERENCE A600 FINISH SCHEDULE FOR CEILING PAINT. 4. MODIFY EXISTING SPRINKLER SYSTEM AND FIRE ALARM AS REQUIRED BY LOCAL CODES. 5. REFERENCE A504 FOR CEILING JOIST ATTACHMENTS AND GYPSUM CONTROL JPINTS. SHEET NOTES 1. EXISTING JOIST GIRDER LOCATIONS (V.I.F.) 2. 3/4" DIAMETER THREADED ROD HANGERS. REF A110 FOR MORE INFORMATION. 3. DIAGONAL WIRE BRACE AT EACH THREADED ROD ATTACHMENT. 4. FABRICATOR OF SUSPENDED WAVE ELEMENT IS RESPONSIBLE FOR UPDATING AND INFORMING AOR & EOR OF ANY AND ALL FABRICATION CHANGES TO WEIGHT OF SUSPENDED STRUCTURE. 5. FABRICATOR OF SUSPENDED WAVE ELEMENTIS RESPONSIBLE FOR ENGINEERING OF SUSPENSION SYSTEM, CONNECTIONS, LATERAL (DIAGONAL CABLE OR SOLID ROD) BRACING AND ATTACHMENTS. 6. FABRICATOR OF SUSPENDED WAVE ELEMENTIS RESPONSIBLE FOR LAYOUT AND CONNECTION FOR INTEGRATED LIGHTING FIXTURES AND ELECTRICAL POWER. 7. CONNECTIONS TO EXISTING BUILDING STRUCTURAL SYSTEM: REFERENCE STRUCTURAL PLANS FOR REQUIRED STIFFENING OF EXISTING JOISTS AT ATTACHMENTS POINTS. KEYNOTE LEGEND NO. DATE DESCRIPTION 02/07/22