HomeMy WebLinkAboutA500 - PARTITION TYPES AND INTERIOR WALL SECTIONSPLENUM
COIL
COOLER PANEL TO
INCORPORATE 2-1/2"
PROTRUSION AROUND OPENING
CONT. WHITE ALUM FLASHING
(SILLS, HEADS, JAMBS) & SEALANT BY
TFM METALS VENDOR
MIN. 1" ARMOR FLEX
INSULATION BY COOLER
BOX MFR.
PRE-FAB COOLER PANEL
MIN. 1" ARMOR FLEX
INSULATION BY COOLER
BOX MFR.
2 1/2"
CONT. WHITE ALUM FLASHING
(SILLS, HEADS, JAMBS)
& SEALANT BY
TFM METALS VENDOR
VERIFY W/ MFR1' - 6 3/4"5' - 0"OH
(3) #10 TEK SCREW AT
EACH STUD (TYP)1"5/8" GYP BD ON 3 5/8" 20 GA. GALV.
METAL STUDS AT 16" @ EDGE OF
COOLER BOX
TOP OF COOLER REF
COOLER DRAWINGS FOR
DETAILS
A502
6
5/8" "MOLD TOUGH" FASTENED TO
COOLER WALL W/SCREWS
TOP OF CASE
SECURE PARTITION TO ROOF
STRUCTURE AND BRACE FROM
STOCK ROOM SIDE AS REQUIRED
(TYP ALL FULL HEIGHT WALLS)
1
1
EXISTING ROOF SYSTEM
3 5/8" 16 GAUGE METAL STUD WITH
NESTED 16 GA. GALV. METAL TRACK
CONT. BLOCKING SECURE TO 20 GA CLIP ANGLE WITH
(2) #10 TEK SCREWS SECURED TO EXIST JOIST.
INSULATION PACK TO
PREVENT LIGHT
TRANSMISSION INTO
SALES AREA. CLIP INSUL.
IN PLACE
A504
3
A102
2
METAL STUDS
SHEATHING BOTH SIDES
A
REFERENCE SIDE OPPOSITE SIDE
B
METAL STUDS
C
BATT INSULATION AS
APPLICABLE. REFERENCE
A100 & A402
SHEATHING
METAL STUDS
SHEATHING
EXISTING CMU
EXTERIOR
WALL
L 2 1/2" X 2 1/2" X 18 GA AT
48" OC VERT. ATTACH TO
STUD WITH (2) #10 TEK
SCREWS AND TO CMU WITH
1/4" MASONRY SCREWS 2"
MIN EMBEDMENT
PARTITION TYPES
BATT INSULATION AS
APPLICABLE. REFERENCE
A100 & A402
BATT INSULATION AS
APPLICABLE. REFERENCE
A100 & A402
PLAN:
LETTER INDICATES
PARTITION TYPE
NUMBER INDICATES
METAL STUD
THICKNESS
METAL STUD THICKNESS:
1 -1 5/8" METAL STUD
2 -2 1/2" METAL STUD
3 -3 5/8" METAL STUD
6 -6" METAL STUD
8 -8" METAL STUDA3
10
HEIGHT OF WALL (NO
NUMBER INDICATES TO
BOTTOM OF STRUCTURE
/ UNDERSIDE OF DECK)
1. IN CONJUNCTION WITH THEIR TRADE SPECIFIC DRAWINGS, CONTRACTOR IS
TO REFER TO RESPONSIBILITY SCHEDULE ON G001 FOR CLARIFICATION OF
SCOPE THAT NEEDS TO BE COORDINATED WITH OTHER TRADES.
2. REF A600 FOR SCHEDULE FINISH KEY.
3. REF A111 FOR SHEATHING PLAN
4. REF INTERIOR BUILDING ELEVATIONS AND FINISH SCHEDULE
FOR ADDITIONAL WALL FINISH REQUIREMENTS, TYP.
5. G.C. TO ENSURE THAT ALL INSTALLED WALLS MEET APPLICABLE CODE
REQUIREMENTS FOR FLAME SPREAD AND SMOKE DEVELOPMENT INDEX FOR
TYPE IIB CONSTRUCTION.
6. METAL STUDS TO BE 20 GA. (33 MIL) MIN AT 16" OC U.N.O. OR HEAVIER AS
INDICATED BY DRAWINGS.
7. ALL METAL STUD FLANGES TO BE 1 5/8" MIN WIDTH.
8. WHERE WALLS ARE NOT SHEATHED FULL HEIGHT ON BOTH SIDES, BRIDGING
IS REQUIRED PER THEIR MAX UNBRACED LENGTH. IF UNBRACED LENGTH OF A
6" 20 GA STUD > 25'-0", BRIDGING IS REQUIRED. IF UNBRACED LENGTH OF A
3 5/8" 20 GA STUD > 15'-0," BRIDGING IS REQUIRED.
9. FULLY SHEATHED WALLS TO RECEIVE BRIDGING AT 1/4 POINTS.
GENERAL NOTESPARTITION LEGEND
FF-EL
EL = 0'-0"4' - 0"16 GA STAINLESS STEEL
COLUMN WRAP BELOW 4'-0" A.F.F.
EL = 4'-0"A.F.F.
PAINT FINISH
FROM 4'-0" TO
DECK
TO UNDERSIDE OF STRUCTURE (VARIES)EXISTING
EL = VARIES
STRUCTURE
4
A500
_______
STEEL COLUMN
ADHERE 2" VERTICAL STRIP
TO COLUMN EACH SIDE
WITH ADHESIVE.
48" HIGH SS COLUMN WRAP.
REFERENCE A100 FOR
LOCATIONS.
PROVIDE 1/4" GAP
BETWEEN (2) STAINLESS
STEEL HALVES
1/4"
PAINT TO COLUMN ABOVE
SS PER FINISH SCHEDULE
PLUMBING
VENT, REF
PLUMB
PROVIDE BLOCKING
AS NEEDED FOR SS
WRAP
STEEL COLUMN
ADHERE 2" VERTICAL
STRIP TO COLUMN EACH
SIDE WITH ADHESIVE.
48" HIGH SS COLUMN
WRAP. REFERENCE
A101.
PROVIDE 1/4" GAP
BETWEEN (2)
STAINLESS STEEL
HALVES
1/4"
PARTITION NOTES
1. REFERENCE CAPTURE TRACK DETAILS FOR DEFLECTION REQUIREMENTS.
2. METAL STUDS ARE SPACED AT 16" ON CENTER MAX UNLESS NOTED OTHERWISE
3. ALL GYPSUM BOARD IS TO BE 5/8" THICK UNLESS NOTED OTHERWISE
4. MAXIMUM HEIGHT OF NON LOAD BEARING WALL ABOVE HEADER TO BE 20'-0".
5. IN ROOMS WITH LAY-IN CEILINGS, EXTEND FINISH 6" MIN ABOVE CEILING. IN ROOMS WITH GYP BOARD
CEILING STOP FINISH AT CEILING.
6. HOLD ALL SUBSTRATE 1/2" ABOVE CONCRETE TO AVOID WICKING ACTION.
7. PROVIDE FIRE BLOCKING AT FLOOR AND ROOF LEVELS, CONCEALED SPACES BETWEEN STAIRWAY
STRINGERS, PENETRATIONS IN FLOOR/CEILING ASSEMBLIES AND OTHER LOCATIONS AS REQUIRED PER
CODE.
8. REFERENCE STRUCTURAL PLANS AND 1/A110 FOR BULKHEAD ATTACHMENTS.
9. PROVIDE BLOCKING AT ALL WALL HUNG EQUIPMENT AS REQUIRED AND DETAILED IN DRAWINGS.
COORDINATE EXACT LOCATION WITH ARCHITECT/OWNER/TENANT.
10. IN CONJUNCTION WITH THEIR TRADE SPECIFIC DRAWINGS, CONTRACTOR IS TO REFER TO
RESPONSIBILITY SCHEDULE ON G001 FOR CLARIFICATION OF SCOPE THAT NEEDS TO BE COORDINATED
WITHOTHER TRADES.
11. REF A600 FOR SCHEDULE FINISH KEY.
12. REF A111 FOR SHEATHING PLAN
13. REF INTERIOR BUILDING ELEVATIONS AND FINISH SCHEDULE FOR ADDITIONAL WALL FINISH
REQUIREMENTS, TYP.
14. G.C. TO ENSURE THAT ALL INSTALLED WALLS MEET APPLICABLE CODE REQUIREMENTS FOR FLAME
SPREAD AND SMOKE DEVELOPMENT INDEX FOR TYPE IIB CONSTRUCTION.
15. METAL STUDS TO BE 20 GA. (33 MIL) MIN AT 16" OC U.N.O. OR HEAVIER AS INDICATED BY DRAWINGS.
16. ALL METAL STUD FLANGES TO BE 1 5/8" MIN WIDTH.
17. WHERE WALLS ARE NOT SHEATHED FULL HEIGHT ON BOTH SIDES, BRIDGING IS REQUIRED PER THEIR
MAX UNBRACED LENGTH. IF UNBRACED LENGTH OF A 6" GA 20 GA STUD > 25'-0", BRIDGING IS REQUIRED. IF
BRACED LENGTH OF A 3 5/8" 20 GA STUD > 15'-0," BRIDGING IS REQUIRED.
18. FULLY SHEATHED WALLS TO RECEIVE BRIDGING AT 1/4 POINTS
SHEET NO.
This drawing was prepared for use on a
specific site contemporaneously with its issue
date and it is not suitable for use on a
different project site or at a later time. Use of
this drawing for reference or example on
another project requires the services of
properly licensed architects and engineers.
Reproduction of this drawing for reuse on
another project is not authorized and may be
contrary to the law.
BRR Original printed on recycled paper
COPYRIGHT NOTICE
CONSULTANT
PROJECT NO.
SHEET TITLE
ISSUES & REVISIONS
CONSULTANT LOGO
DRAWN BY: REBECCA BEASLEY
PROFESSIONAL SEAL
PROJECT MANAGER: DAN VON SEGGERN
DOCUMENT DATE:
CHECKED BY: JOHN SCHWEIGER
PROJECT NAME
PROJECT ADDRESS
1 2 3 4 5 ABCDEABCDE123 4 5
TREVOR TYSON HOLCOMB
ARCHITECT
AR11800234
ARCHITECT OF RECORD:
TREVOR TYSON HOLCOMB
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
12/7/2021 12:18:50 PMPARTITION TYPES
AND INTERIOR
WALL SECTIONS
A500
62930563
12/07/21
THE FRESH
MARKET
1392 S. RANGELINE
ROAD
CARMEL, IN 46032
1" = 1'-0"1 SECTION AT REAR LOADING DAIRY COOLER
1" = 1'-0"3 SALES FLOOR COLUMN WRAP DETAIL
1 1/2" = 1'-0"4 COLUMN WRAP-SS1
1 1/2" = 1'-0"5 COLUMN WRAP-SS PIPE NO. DATE DESCRIPTION
02/07/22