HomeMy WebLinkAboutE101_Lighting Fixture Schedule And Symbol LegendTRADITIONAL LIGHTING PACKAGE
TYPE SYMBOL DESCRIPTION MANUFACTURER AND MODEL # MOUNTING VOLTAGE LAMPS/
FIXTURE COLOR TEMP BALLASTS/
FIXTURE
INPUT
WATTS/
FIXTURE
NOTES
A 2'x2' LENSED GRID HIGH FLAT LENSE US LED GTR3-22-35-80-F-A-H-N CEILING RECESSED 120-277V LED - 5062 LUMENS 3500K 1 50.5 W
56 VA -
AE 2'x2' LENSED GRID HIGH FLAT LENSE EM US LED GTR3-22-35-80-F-A-H-B CEILING RECESSED 120-277V LED - 5062 LUMENS 3500K 1 50.5 W
56 VA 1
AG 2'x2' LENSED GRID TROFFER. US LED GTR3-22-35-80-F-A-S-N CEILING RECESSED 120-277V LED - 3564 LUMENS 3500K 1 32.8 W
36 VA -
AGE 2'x2' LENSED GRID3 HIGH FLAT LENSE EM US LED GTR3-22-35-80-F-A-S-B CEILING RECESSED 120-277V LED - 3564 LUMENS 3500K 1 32.8 W
36 VA 1
DL DOCK LIGHT WITH MOUNTING ARM, ON/OFF SWITCH,
AND WET LOCATION LABEL.US LED LEDDL16565Y01 WITH 90" ARM WALL BRACKET AT
5'-0" AFF 120-277V LED - 870 LUMENS 6500K 1 17 W
19 VA -
DP2 LED DECORATIVE PENDANT US LED FM1-WH-WH-35-105-180 CORD MOUNT 1O'-0"
AFF TO BOTTOM UON 120V LED - 3330 LUMENS 3500K 1 36 W
40 VA 4
H2 4' VAPORTIGHT LED. US LED USVT-24-35 SURFACE MOUNT 120V LED - 4014 LUMENS
3500K
2 STAR-TB
LED TUBE
1 31.4 W
44 VA -
H2 4' DG1 LINEAR HIGH LED W/DIMMING.US LED DG1-2-1-35-1-2-PUE- UNV2-4100-2
MOUNT 9' -6" AFF.
USING Y-DROP STYLE
TOGGLE KIT. UON
120-277V LED - 10142 LUMENS 3500K 1 97 W
108 VA -
H1 8' VAPORTIGHT LED. US LED USVT-44-35 SURFACE MOUNT 120V LED - 8028 LUMENS
3500K
4 STAR-TB
LED TUBE
1 62.8 W
88 VA -
LR6 LED DOWNLIGHT. 6 IN. TRIM. US LED LTR2-1-UNV-35-15-6R-C-WH CEILING RECESSED 120V LED - 877 LUMENS 3000K 1 15.5 W
16 VA -
M LED PENDANT. US LED P32
PENDANT MOUNT
14' -0" AFF TO
BOTTOM UON
120-277V LED - 1328 LUMENS 3500K 1 15 W
17 VA -
P 8 WATT LED GRAVITY-FIT PENDANT. US LED CRS89630K-106W-AB-10'
PENDANT MOUNT
6'-0" AFF TO BOTTOM
UON
120-277V LED - 750 LUMENS 3500K 1 8.1 W -
PS 3 LAMP FISHER ISLAND LED PENDANT. US LED FC00065870
PENDANT MOUNT
8'-0" AFF TO BOTTOM
UON
120-277V LED - 2250 LUMENS 3000K 3 27 W
30 VA -
W LED EXTERIOR EGRESS WALL SCONCE DUAL LITE PG-W
EM WALL SCONCE
9'-0" AFF TO BOTTOM
UON
120-277V LED - 405 LUMENS 6350K 1 2.78 W
3 VA 6
W1 LED EXTERIOR WALL SCONCE US LED DSCO1-3-UNVL-50-96-BZ
WALL SCONCE
15'-0" AFF TO BOTTOM
UON
120-277V LED - 960 LUMENS 5000K 1 40 W
44VA 5
B12 1-CIRCUIT TRACK (12'-0" NOMINAL LENGTH). US LED LT-12-P
CABLE MOUNT 12'-0"
AFF TO BOTTOM OF
TRACK UON
120V - - - -2
B8 1-CIRCUIT TRACK (8'-0" NOMINAL LENGTH). US LED LT-8-P
CABLE MOUNT 12'-0"
AFF TO BOTTOM OF
TRACK UON
120V - - - - 2
B6 1-CIRCUIT TRACK (6'-0" NOMINAL LENGTH). US LED LT-6-P
CABLE MOUNT 12'-0"
AFF TO BOTTOM OF
TRACK UON
120V - - - - 2
B4 1-CIRCUIT TRACK ( 4'-0" NOMINAL LENGTH). US LED LT-4-P
CABLE MOUNT 12'-0"
AFF TO BOTTOM OF
TRACK UON
120V - - - - 2
B2 1-CIRCUIT TRACK (2'-0" NOMINAL LENGTH). US LED LT-2-P
CABLE MOUNT 12'-0"
AFF TO BOTTOM OF
TRACK UON
120V - - - - 2
BC 1-CIRCUIT TRACK (FIELD CUT TO LENGTH).US LED LT-2-P
CABLE MOUNT 12'-0"
AFF TO BOTTOM OF
TRACK UON
120V ----2
PAR38 LED TRACK HEAD AND GIMBAL RING FOR
PAR 38. SALES FLOOR.US LED CTL 2838N-P TRACK MOUNT 120V LED - 1050 LUMENS
3000K
16PAR38G3
DIM/830NF25
1 16
18.5 VA -
LT LED TRACK HEAD AND GIMBAL RING FOR PAR
30. SALES FLOOR.US LED CTL 2830N-P TRACK MOUNT 120V LED - 850 LUMENS
3000K
14PAR30G3
DIM/830NF25
1 14
12.5 VA -
X LED EXIT SIGN.US LED CXL3RW UNIVERSAL 120-277V LED 1 3.7
4 VA 3
STRAIGHT TRACK JOINER. US LED
TRACK JOINER. US LED
TRACK END FEED. US LED
NOTES:
1. CONNECT BRANCH CIRCUIT TO EMERGENCY BALLAST AHEAD OF CONTACTORS AND LOCAL SWITCHING.
2. ATTACH SUPPORT CABLE TO TRACK PER TFM'S INSTRUCTIONS.
3. CONNECT TO BRANCH CIRCUIT AHEAD OF CONTACTORS AND LOCAL SWITCHING.
4. DP2 FIXTURES LOCATED OVER THE CHECKSTANDS SHALL BE PROVIDED WITH (2) ADDITIONAL MANUFACTURER'S LENSES PER FIXTURE, PART #09-000130.
5. CONFIRM LAMP COLOR PRIOR TO ORDERING.
6. CONFIRM FIXTURE HOUSING COLOR PRIOR TO ORDERING.
H2
H
A
DP2
M
LR6
H1
PAR38
LT
X
P
AE
AG
AGE
B8
B12
B4
B6
BC
B2
P2
W1
W
RTU
LFMC
TFM
UON
WP
C.
WG
AFF
G.
ROOF TOP UNIT
UNLESS OTHERWISE NOTED
LIQUIDTIGHT FLEXIBLE METAL CONDUIT
THE FRESH MARKET
ABOVE FINISHED FLOOR
WEATHERPROOF(WHILE-IN-USE)
GROUND
WEATHERPROOF(WHILE-IN-USE)/GFCI TYPE
CONDUIT
IG ISOLATED GROUND
GF GROUND FAULT CIRCUIT INTERRUPTER
(P)PARTIAL CIRCUIT
T1
DATA OUTLET WITH PATCH PANEL PORT # INDICATED.
DSL OUTLET. PROVIDE CABLING TO DSL EQUIPMENT ON
TELECOM BACKBOARD.DSL
D1
TELEPHONE OUTLET WITH OUTLET # INDICATED.
CPC OUTLET.CPC
EMPLOYEE TIME CLOCK DATA OUTLET. PROVIDE CABLING
PER TFM SPECIFICATIONS.TC
DOOR SENSOR.DS
NOTES:
PROVIDE OUTLET BOX AND PROVIDE CONDUIT AS INDICATED ON
DRAWINGS E109 AND EU102.
ALL FIXTURES, LAMPS, TRACK, TRACK FITTINGS AND SUPPORT CABLE SHALL BE FURNISHED BY THE FRESH MARKET AND
INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED. QUANTITIES SHALL BE VERIFIED BY TFM'S SUPPLIER.
ETR,(E) EXISTING TO REMAIN
TYPICAL LIGHTING FIXTURES - LETTER INDICATES TYPE.
EMERGENCY LIGHTING UNIT -SEE LIGHTING FIXTURE
SCHEDULE.
REMOTE EMERGENCY LAMP HEADS - SEE LIGHTING
FIXTURE SCHEDULE.
DUPLEX RECEPTACLE.
GFCI DUPLEX RECEPTACLE.
GF
GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF-
WHILE-IN USE COVER.WG
SPECIAL PURPOSE RECEPTACLE.
ISOLATED GROUND SIMPLEX RECEPTACLE WITH ORANGE
FACE.
ISOLATED GROUND DUPLEX RECEPTACLE WITH ORANGE
FACE.
IG
IG
FLOOR BOX WITH DUPLEX GFCI RECEPTACLE AND ROUND
BRASS COVER WITH FLIP LIDS. LEGRAND 881-895TGFI.
FUSIBLE DISCONNECT, AMP RATING/# POLES/FUSE RATING
INDICATED. IF NO FUSE RATING IS INDICATED, FUSE PER
EQUIPMENT MANUFACTURER'S RECOMMENDED MOCP.
PRVOIDE TYPE NEMA 3R FOR OUTDOOR LOCATIONS.
ELECTRICAL CONNECTION TO EQUIPMENT. COORDINATE
LOCATION AND CONNECTION DETAILS WITH EQUIPMENT
PROVIDER.
JUNCTION BOX.
SINGLE POLE SWITCH.
THREE-WAY SWITCH.
2-POLE MOTOR-RATED TOGGLE DISCONNECT WITH
PADLOCKABLE HANDLE.
20A SWITCH WITH RED PILOT LIGHT (PILOT LIGHT ON
WHEN LIGHTS ARE ON).
DOOR LIMIT SWITCH.
EXIT SIGN - SEE LIGHTING FIXTURE SCHEDULE.
FILLED SECTION INDICATES FACE, ARROW INDICATES
DIRECTION
FLUSH MOUNTED PANEL BOARD.
SURFACE MOUNTED PANEL BOARD.
MOTION SENSOR - SENSOR SWITCH #CMR-9-LT-P, OR
EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT
SETTINGS AFTER INSTALLATION TO PROVIDE PROPER
OPERATION OF THE DEVICE.
MOTION SENSOR - SENSOR SWITCH #CMR-PDT-2P, OR
EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT
SETTINGS AFTER INSTALLATION TO PROVIDE PROPER
OPERATION OF THE DEVICE.
WEATHERPROOF PUSH BUTTON FOR DOOR BELL -
EDWARDS #1785 OR EQUAL.
DOOR BELL AND TRANSFORMER. EDWARDS #340-4GS
BELL (24v, 4") AND #599 TRANSFORMER (120v PRI. - 24v
SEC.) OR EQUAL.
BRANCH CIRCUIT CONCEALED, UNLESS OTHERWISE
NOTED.
HOMERUN CIRCUIT - PANEL AND CIRCUIT NUMBER
INDICATED.
PIR OCCUPANCY SENSING WALL SWITCH - SENSOR SWITCH
#WSD NGX OR EQUAL. CONTRACTOR SHALL ADJUST THE
DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE
PROPER OPERATION OF THE DEVICE. SWITCH TO BE SET
FOR MANUAL 'ON' AND AUTO 'OFF'
FLOOR BOX WITH SPECIAL RECEPTACLE TO MATCH
EQUIPMENT REQUIREMENTS AND ROUND BRASS COVER.
LEGRAND 881-896TCK.
SHEET NO.
This drawing was prepared for use on a
specific site contemporaneously with its issue
date and it is not suitable for use on a
different project site or at a later time. Use of
this drawing for reference or example on
another project requires the services of
properly licensed architects and engineers.
Reproduction of this drawing for reuse on
another project is not authorized and may be
contrary to the law.
BRR Original printed on recycled paper
COPYRIGHT NOTICE
PROJECT NO.
SHEET TITLE
ISSUES & REVISIONS
DRAWN BY:
PROFESSIONAL SEAL
PROJECT MANAGER:
DOCUMENT DATE:
CHECKED BY:
PROJECT NAME
PROJECT ADDRESS
1 2 3 4 5 ABCDEABCDE12 3 4 5
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
ARCHITECT OF RECORD:
62930563
12/07/2021
THE FRESH
MARKET
The Centre Retail Center
NO. DATE DESCRIPTION
An Erdman Anthony Company
552 Fort Evans RD STE 200
Leesburg, VA 20176
703.777.5988
Leesburg@erdmananthony.com
116th St. and Rangeline Rd.
Carmel, Indiana
LIGHTING
SCHEDULE &
SYMBOL
LEGEND
E-101
BSD
DSP
LC LIGHTING CONTACTOR COIL
USB
DUPLEX RECEPTACLE WITH USB CHARGER.
E101 ELECTRICAL NOTES, SYMBOLS, AND SCHEDULES
E102 LIGHTING PLAN
E103 EMERGENCY LIGHTING AND EXIT SIGN PLAN
E104 POWER PLAN
E105 ENLARGED POWER PLANS
E106 ROOF POWER PLAN
E107 CASE POWER AND LIGHTING PLAN
E108 LOW VOLTAGE DEVICES AND WIRING PLAN
E109 LOW VOLTAGE RISER AND DETAILS
E110 ELECTRICAL RISER
E111 ELECTRICAL SCHEDULES
E112 ELECTRICAL SCHEDULES
E113 ELECTRICAL DETAILS
E114 ELECTRICAL DETAILS
E116 FIRE ALARM PLANS
1. PRIOR TO REFRIGERATION STARTUP PROVIDE SEAL FITTINGS AT ELECTRICAL PENETRATIONS INTO
FREEZERS, COOLERS AND PREP AREAS TO PREVENT MOISTURE MIGRATION. CAULK AROUND
CONDUIT PENETRATIONS THROUGH WALL AND CEILINGS. CAULK WIRES INSIDE CONDUIT
ENTERING COOLER/FREEZER. SEE DETAIL 10/E113.
2. DO NOT ATTACH SUPPORTS TO THE ROOF DECK. INSTEAD, ATTACH SUPPORTS TO THE ROOF
STRUCTURAL FRAMING.
3. UNLESS OTHERWISE NOTED, TYPE MC CABLE SHALL NOT BE PERMITTED EXCEPT FOR WHIPS OF
LESS THAN 6 FEET DOWN FROM JUNCTION BOXES TO LIGHT FIXTURES MOUNTED IN DROPPED
CEILINGS.
4. CONDUIT FOR LIGHTING AND EVAPORATOR SHALL RUN ALONG TOP OF COOLER BOXES. CONDUIT
SHALL NOT RUN INSIDE COOLER BOXES. CONDUIT IS ALLOWED TO RUN INSIDE FREEZER BOXES
(TO LIMIT BOX PENETRATIONS).
5. LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL BE USED UNDER REFRIGERATED CASES.
6. LIGHT FIXTURES IN FOOD PREP AREAS ARE ALL LED AND HAVE SHATTERPROOF COVERS.
7. ALL PENETRATIONS SHALL BE PROPERLY SEALED.
8. ALL SWITCHES & OUTLETS TO BE WHITE. COVERS TO BE STAINLESS AT FOOD PREP AREAS &
“LIGHT ALMOND” EVERYWHERE ELSE. BOTH LEGRAND AND PASS & SEYMOUR MAKE THIS COLOR.
9. LIGHT FIXTURES ARE PURCHASED BY THE FRESH MARKET. THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR RECEIVING, INVENTORYING, SECURING AND INSTALLING THE FIXTURES
10. IN BOX COOLERS/FREEZERS, COORDINATE LIGHTING FIXTURES WITH BLOWER COIL UNITS.
11. LEVEL LIGHTING TRACKS AFTER INSTALLING, POSITIONING AND AIMING LAMP HEAD.
12. COORDINATE LIGHTING FIXTURE LOCATIONS WITH REFLECTED CEILING PLAN ON ARCHITECTURAL
DRAWINGS.
13. DO NOT ATTACH SUPPORTS TO THE ROOF DECK. INSTEAD, ATTACH SUPPORTS TO THE ROOF
STRUCTURAL FRAMING.
14. TYPE SO CORD (BLACK IF THERE IS AN EXPOSED OR GREEN CEILING AND WHITE IF THERE IS A
WHITE CEILING), OR MC CABLE IF TYPE SO CORD IS PROHIBITED, SHALL BE USED FOR DROPS
DOWN TO LIGHTING TRACK.
12/08/2021
02/07/22