HomeMy WebLinkAboutE101_Lighting Fixture Schedule And Symbol LegendTRADITIONAL LIGHTING PACKAGE TYPE SYMBOL DESCRIPTION MANUFACTURER AND MODEL # MOUNTING VOLTAGE LAMPS/ FIXTURE COLOR TEMP BALLASTS/ FIXTURE INPUT WATTS/ FIXTURE NOTES A 2'x2' LENSED GRID HIGH FLAT LENSE US LED GTR3-22-35-80-F-A-H-N CEILING RECESSED 120-277V LED - 5062 LUMENS 3500K 1 50.5 W 56 VA - AE 2'x2' LENSED GRID HIGH FLAT LENSE EM US LED GTR3-22-35-80-F-A-H-B CEILING RECESSED 120-277V LED - 5062 LUMENS 3500K 1 50.5 W 56 VA 1 AG 2'x2' LENSED GRID TROFFER. US LED GTR3-22-35-80-F-A-S-N CEILING RECESSED 120-277V LED - 3564 LUMENS 3500K 1 32.8 W 36 VA - AGE 2'x2' LENSED GRID3 HIGH FLAT LENSE EM US LED GTR3-22-35-80-F-A-S-B CEILING RECESSED 120-277V LED - 3564 LUMENS 3500K 1 32.8 W 36 VA 1 DL DOCK LIGHT WITH MOUNTING ARM, ON/OFF SWITCH, AND WET LOCATION LABEL.US LED LEDDL16565Y01 WITH 90" ARM WALL BRACKET AT 5'-0" AFF 120-277V LED - 870 LUMENS 6500K 1 17 W 19 VA - DP2 LED DECORATIVE PENDANT US LED FM1-WH-WH-35-105-180 CORD MOUNT 1O'-0" AFF TO BOTTOM UON 120V LED - 3330 LUMENS 3500K 1 36 W 40 VA 4 H2 4' VAPORTIGHT LED. US LED USVT-24-35 SURFACE MOUNT 120V LED - 4014 LUMENS 3500K 2 STAR-TB LED TUBE 1 31.4 W 44 VA - H2 4' DG1 LINEAR HIGH LED W/DIMMING.US LED DG1-2-1-35-1-2-PUE- UNV2-4100-2 MOUNT 9' -6" AFF. USING Y-DROP STYLE TOGGLE KIT. UON 120-277V LED - 10142 LUMENS 3500K 1 97 W 108 VA - H1 8' VAPORTIGHT LED. US LED USVT-44-35 SURFACE MOUNT 120V LED - 8028 LUMENS 3500K 4 STAR-TB LED TUBE 1 62.8 W 88 VA - LR6 LED DOWNLIGHT. 6 IN. TRIM. US LED LTR2-1-UNV-35-15-6R-C-WH CEILING RECESSED 120V LED - 877 LUMENS 3000K 1 15.5 W 16 VA - M LED PENDANT. US LED P32 PENDANT MOUNT 14' -0" AFF TO BOTTOM UON 120-277V LED - 1328 LUMENS 3500K 1 15 W 17 VA - P 8 WATT LED GRAVITY-FIT PENDANT. US LED CRS89630K-106W-AB-10' PENDANT MOUNT 6'-0" AFF TO BOTTOM UON 120-277V LED - 750 LUMENS 3500K 1 8.1 W - PS 3 LAMP FISHER ISLAND LED PENDANT. US LED FC00065870 PENDANT MOUNT 8'-0" AFF TO BOTTOM UON 120-277V LED - 2250 LUMENS 3000K 3 27 W 30 VA - W LED EXTERIOR EGRESS WALL SCONCE DUAL LITE PG-W EM WALL SCONCE 9'-0" AFF TO BOTTOM UON 120-277V LED - 405 LUMENS 6350K 1 2.78 W 3 VA 6 W1 LED EXTERIOR WALL SCONCE US LED DSCO1-3-UNVL-50-96-BZ WALL SCONCE 15'-0" AFF TO BOTTOM UON 120-277V LED - 960 LUMENS 5000K 1 40 W 44VA 5 B12 1-CIRCUIT TRACK (12'-0" NOMINAL LENGTH). US LED LT-12-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - -2 B8 1-CIRCUIT TRACK (8'-0" NOMINAL LENGTH). US LED LT-8-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 B6 1-CIRCUIT TRACK (6'-0" NOMINAL LENGTH). US LED LT-6-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 B4 1-CIRCUIT TRACK ( 4'-0" NOMINAL LENGTH). US LED LT-4-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 B2 1-CIRCUIT TRACK (2'-0" NOMINAL LENGTH). US LED LT-2-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 BC 1-CIRCUIT TRACK (FIELD CUT TO LENGTH).US LED LT-2-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V ----2 PAR38 LED TRACK HEAD AND GIMBAL RING FOR PAR 38. SALES FLOOR.US LED CTL 2838N-P TRACK MOUNT 120V LED - 1050 LUMENS 3000K 16PAR38G3 DIM/830NF25 1 16 18.5 VA - LT LED TRACK HEAD AND GIMBAL RING FOR PAR 30. SALES FLOOR.US LED CTL 2830N-P TRACK MOUNT 120V LED - 850 LUMENS 3000K 14PAR30G3 DIM/830NF25 1 14 12.5 VA - X LED EXIT SIGN.US LED CXL3RW UNIVERSAL 120-277V LED 1 3.7 4 VA 3 STRAIGHT TRACK JOINER. US LED TRACK JOINER. US LED TRACK END FEED. US LED NOTES: 1. CONNECT BRANCH CIRCUIT TO EMERGENCY BALLAST AHEAD OF CONTACTORS AND LOCAL SWITCHING. 2. ATTACH SUPPORT CABLE TO TRACK PER TFM'S INSTRUCTIONS. 3. CONNECT TO BRANCH CIRCUIT AHEAD OF CONTACTORS AND LOCAL SWITCHING. 4. DP2 FIXTURES LOCATED OVER THE CHECKSTANDS SHALL BE PROVIDED WITH (2) ADDITIONAL MANUFACTURER'S LENSES PER FIXTURE, PART #09-000130. 5. CONFIRM LAMP COLOR PRIOR TO ORDERING. 6. CONFIRM FIXTURE HOUSING COLOR PRIOR TO ORDERING. H2 H A DP2 M LR6 H1 PAR38 LT X P AE AG AGE B8 B12 B4 B6 BC B2 P2 W1 W RTU LFMC TFM UON WP C. WG AFF G. ROOF TOP UNIT UNLESS OTHERWISE NOTED LIQUIDTIGHT FLEXIBLE METAL CONDUIT THE FRESH MARKET ABOVE FINISHED FLOOR WEATHERPROOF(WHILE-IN-USE) GROUND WEATHERPROOF(WHILE-IN-USE)/GFCI TYPE CONDUIT IG ISOLATED GROUND GF GROUND FAULT CIRCUIT INTERRUPTER (P)PARTIAL CIRCUIT T1 DATA OUTLET WITH PATCH PANEL PORT # INDICATED. DSL OUTLET. PROVIDE CABLING TO DSL EQUIPMENT ON TELECOM BACKBOARD.DSL D1 TELEPHONE OUTLET WITH OUTLET # INDICATED. CPC OUTLET.CPC EMPLOYEE TIME CLOCK DATA OUTLET. PROVIDE CABLING PER TFM SPECIFICATIONS.TC DOOR SENSOR.DS NOTES: PROVIDE OUTLET BOX AND PROVIDE CONDUIT AS INDICATED ON DRAWINGS E109 AND EU102. ALL FIXTURES, LAMPS, TRACK, TRACK FITTINGS AND SUPPORT CABLE SHALL BE FURNISHED BY THE FRESH MARKET AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED. QUANTITIES SHALL BE VERIFIED BY TFM'S SUPPLIER. ETR,(E) EXISTING TO REMAIN TYPICAL LIGHTING FIXTURES - LETTER INDICATES TYPE. EMERGENCY LIGHTING UNIT -SEE LIGHTING FIXTURE SCHEDULE. REMOTE EMERGENCY LAMP HEADS - SEE LIGHTING FIXTURE SCHEDULE. DUPLEX RECEPTACLE. GFCI DUPLEX RECEPTACLE. GF GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF- WHILE-IN USE COVER.WG SPECIAL PURPOSE RECEPTACLE. ISOLATED GROUND SIMPLEX RECEPTACLE WITH ORANGE FACE. ISOLATED GROUND DUPLEX RECEPTACLE WITH ORANGE FACE. IG IG FLOOR BOX WITH DUPLEX GFCI RECEPTACLE AND ROUND BRASS COVER WITH FLIP LIDS. LEGRAND 881-895TGFI. FUSIBLE DISCONNECT, AMP RATING/# POLES/FUSE RATING INDICATED. IF NO FUSE RATING IS INDICATED, FUSE PER EQUIPMENT MANUFACTURER'S RECOMMENDED MOCP. PRVOIDE TYPE NEMA 3R FOR OUTDOOR LOCATIONS. ELECTRICAL CONNECTION TO EQUIPMENT. COORDINATE LOCATION AND CONNECTION DETAILS WITH EQUIPMENT PROVIDER. JUNCTION BOX. SINGLE POLE SWITCH. THREE-WAY SWITCH. 2-POLE MOTOR-RATED TOGGLE DISCONNECT WITH PADLOCKABLE HANDLE. 20A SWITCH WITH RED PILOT LIGHT (PILOT LIGHT ON WHEN LIGHTS ARE ON). DOOR LIMIT SWITCH. EXIT SIGN - SEE LIGHTING FIXTURE SCHEDULE. FILLED SECTION INDICATES FACE, ARROW INDICATES DIRECTION FLUSH MOUNTED PANEL BOARD. SURFACE MOUNTED PANEL BOARD. MOTION SENSOR - SENSOR SWITCH #CMR-9-LT-P, OR EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE PROPER OPERATION OF THE DEVICE. MOTION SENSOR - SENSOR SWITCH #CMR-PDT-2P, OR EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE PROPER OPERATION OF THE DEVICE. WEATHERPROOF PUSH BUTTON FOR DOOR BELL - EDWARDS #1785 OR EQUAL. DOOR BELL AND TRANSFORMER. EDWARDS #340-4GS BELL (24v, 4") AND #599 TRANSFORMER (120v PRI. - 24v SEC.) OR EQUAL. BRANCH CIRCUIT CONCEALED, UNLESS OTHERWISE NOTED. HOMERUN CIRCUIT - PANEL AND CIRCUIT NUMBER INDICATED. PIR OCCUPANCY SENSING WALL SWITCH - SENSOR SWITCH #WSD NGX OR EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE PROPER OPERATION OF THE DEVICE. SWITCH TO BE SET FOR MANUAL 'ON' AND AUTO 'OFF' FLOOR BOX WITH SPECIAL RECEPTACLE TO MATCH EQUIPMENT REQUIREMENTS AND ROUND BRASS COVER. LEGRAND 881-896TCK. SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana LIGHTING SCHEDULE & SYMBOL LEGEND E-101 BSD DSP LC LIGHTING CONTACTOR COIL USB DUPLEX RECEPTACLE WITH USB CHARGER. E101 ELECTRICAL NOTES, SYMBOLS, AND SCHEDULES E102 LIGHTING PLAN E103 EMERGENCY LIGHTING AND EXIT SIGN PLAN E104 POWER PLAN E105 ENLARGED POWER PLANS E106 ROOF POWER PLAN E107 CASE POWER AND LIGHTING PLAN E108 LOW VOLTAGE DEVICES AND WIRING PLAN E109 LOW VOLTAGE RISER AND DETAILS E110 ELECTRICAL RISER E111 ELECTRICAL SCHEDULES E112 ELECTRICAL SCHEDULES E113 ELECTRICAL DETAILS E114 ELECTRICAL DETAILS E116 FIRE ALARM PLANS 1. PRIOR TO REFRIGERATION STARTUP PROVIDE SEAL FITTINGS AT ELECTRICAL PENETRATIONS INTO FREEZERS, COOLERS AND PREP AREAS TO PREVENT MOISTURE MIGRATION. CAULK AROUND CONDUIT PENETRATIONS THROUGH WALL AND CEILINGS. CAULK WIRES INSIDE CONDUIT ENTERING COOLER/FREEZER. SEE DETAIL 10/E113. 2. DO NOT ATTACH SUPPORTS TO THE ROOF DECK. INSTEAD, ATTACH SUPPORTS TO THE ROOF STRUCTURAL FRAMING. 3. UNLESS OTHERWISE NOTED, TYPE MC CABLE SHALL NOT BE PERMITTED EXCEPT FOR WHIPS OF LESS THAN 6 FEET DOWN FROM JUNCTION BOXES TO LIGHT FIXTURES MOUNTED IN DROPPED CEILINGS. 4. CONDUIT FOR LIGHTING AND EVAPORATOR SHALL RUN ALONG TOP OF COOLER BOXES. CONDUIT SHALL NOT RUN INSIDE COOLER BOXES. CONDUIT IS ALLOWED TO RUN INSIDE FREEZER BOXES (TO LIMIT BOX PENETRATIONS). 5. LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL BE USED UNDER REFRIGERATED CASES. 6. LIGHT FIXTURES IN FOOD PREP AREAS ARE ALL LED AND HAVE SHATTERPROOF COVERS. 7. ALL PENETRATIONS SHALL BE PROPERLY SEALED. 8. ALL SWITCHES & OUTLETS TO BE WHITE. COVERS TO BE STAINLESS AT FOOD PREP AREAS & “LIGHT ALMOND” EVERYWHERE ELSE. BOTH LEGRAND AND PASS & SEYMOUR MAKE THIS COLOR. 9. LIGHT FIXTURES ARE PURCHASED BY THE FRESH MARKET. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, INVENTORYING, SECURING AND INSTALLING THE FIXTURES 10. IN BOX COOLERS/FREEZERS, COORDINATE LIGHTING FIXTURES WITH BLOWER COIL UNITS. 11. LEVEL LIGHTING TRACKS AFTER INSTALLING, POSITIONING AND AIMING LAMP HEAD. 12. COORDINATE LIGHTING FIXTURE LOCATIONS WITH REFLECTED CEILING PLAN ON ARCHITECTURAL DRAWINGS. 13. DO NOT ATTACH SUPPORTS TO THE ROOF DECK. INSTEAD, ATTACH SUPPORTS TO THE ROOF STRUCTURAL FRAMING. 14. TYPE SO CORD (BLACK IF THERE IS AN EXPOSED OR GREEN CEILING AND WHITE IF THERE IS A WHITE CEILING), OR MC CABLE IF TYPE SO CORD IS PROHIBITED, SHALL BE USED FOR DROPS DOWN TO LIGHTING TRACK. 12/08/2021 02/07/22