HomeMy WebLinkAboutE104_Power PlanPA-33(P) WG/48" GF/80" PA-23 8 KEY NOTES 1 MOUNT RECEPTACLE TO GONDOLA MILLWORK. 2 FLOOR BOX FOR FUTURE DISPLAY. 3 RECEPTACLE FOR REVERSE OSMOSIS SYSTEM. MOUNT ABOVE EQUIPMENT SHELF. 4 CONTRACTOR SHALL CIRCUIT HOOD LIGHTS TO MANUFACTURER PROVIDED LIGHTING CONTROLS. 5 CONNECTION FOR HAND DRYER, MOUNT AT 45” AFF. COORDINATE LOCATION WITH ARCHITECTURAL DRAWINGS. 6 RECEPTACLE FOR BAGGED ICE FREEZER. 7 PLUG AND CONNECTOR FOR MEAT GRINDER OR MEAT SAW PROVIDE HUBBELL #HBL2423SW CONNECTOR, AND #HBL2421SW PLUG WITH 6’-0” LONG, 12/4 (3#12, #12 G.) SO CORD. HANG FROM CEILING WITH 12/4 SO CORD (FIELD-DETERMINE LENGTH) WITH STRAIN RELIEF GRIPS. 8 RECEPTACLE FOR MEAT AISLE TAKE-A-NUMBER SYSTEM. 9 RECEPTACLE FOR BUG LIGHT. PROVIDE CORD AND PLUG AND CONNECT TO BUG LIGHT. MOUNT BUG LIGHT AT 80” AFF TO BOTTOM UNLESS OTHERWISE NOTED. 10 CONNECT TO EXISTING AUTOMATIC DOOR OPERATOR. 11 RECEPTACLE FOR DEODORIZER. MOUNT RECEPTACLE 6” ABOVE COMPACTOR CHUTE DOOR. 12 ROUTE CONDUIT DOWN ALONG SIDE OF REFRIGERATION PIPING. 13 RECEPTACLE FOR FLOOR MACHINE. 14 CONNECT TO ICE FLAKER. 15 TRASH COMPACTOR CONNECTION. ROUTE POWER CIRCUIT FOR COMPACTOR THRU DISCONNECT SWITCH. MOUNT CONTROLLER AND PROVIDE CONTROL WIRING PER MANUFACTURER’S SPECIFICATIONS. 16 CONNECT TO BALER. 17 CONTRACTOR SHALL PROVIDE A CORD AND PLUG FOR THE EQUIPMENT. 18 AIR DOOR IS FURNISHED WITH MANUFACTURE'S DISCONNECT SWITCH. COORDINATE WITH MECHANICAL CONTRACTOR. 19 RECEPTACLE FOR DOCK LIGHT. 20 POWER AND CONTROL WIRING FROM CONDENSING UNIT ON ROOF, REFER TO E106. 21 RECEPTACLE FOR REFRIGERATION WIFI. MOUNT RECEPTACLE TO BAR JOIST. 22 FLOOR BOX FOR CHECKSTAND MERCHANDISER. 23 FLOOR BOX FOR ROTISSERIE CHICKEN. 24 FLOOR BOX FOR S/C PRODUCE BIN. 25 EMPLOYEE MICROWAVE RECEPTACLE. 26 CONTROL POWER FOR DEFROST PANEL. 27 RECEPTACLE FOR ELECTRIC WATER COOLER. COORDINATE LOCATION WITH PLUMBING CONTRACTOR PRIOR TO ROUGH-IN. 28 CONNECT TO FACTORY JUNCTION BOX FOR POWER TO CASE IG RECEPTACLES. 29 MOUNT RECEPTACLE HORIZONTALLY ABOVE THE COUNTER. 30 CONTROL POWER FOR REFRIGERATION RACK A. 31 POWER CONNECTION FOR RACK B CONTROLS 32 FAN COIL UNIT IS BEING RELOCATED IN THE ROOM, EC SHALL EXTEND EXISTING POWER AND CONTROL WIRING TO NEW LOCATION. 33 CONTROL POWER FOR COMPACTOR. COORDINATE LOCATION OF CONTROLLER WITH TFM REPRESENTATIVE PRIOR TO ROUGH-IN. 34 MOUNT RECEPTACLE HORIZONTALLY ABOVE BACKSPLASH. 35 SEE ELEVATION 1/E114 FOR RECEPTACLE LOCATIONS AND CIRCUITING. 36 CONTRACTOR TO ROUTE CIRCUITS IN BELOW SLAB CONDUIT AND CONNECT TO QUAD RECEPTACLE FURNISHED WITH CABINET. SEE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION. 37 RECEPTACLE FOR BATTERY POWERED WHEEL CHAIR. 38 CONNECTION TO WH RECIRC. PUMP. 39 COORDINATE OUTLET INSTALLATION WITH MILLWORK. 40 CONNECT TO INSTANTANEOUS WATER HEATER. COORDINATE INSTALLATION WITH PC PRIOR TO ROUGH-IN. 41 FLOOR BOX FOR HEN HUT. 42 CONNECTION TO QUAD RECEPTS, TYPICAL. 43 THIS GFCI RECEPTACLE SHALL PROVIDE GROUND FAULT PROTECTION FOR ANY DOWNSTREAM RECEPTACLES. 44 EC SHALL PROVIDE A 2 POLE CONTACTOR ABOVE ACCESSIBLE CEILING IN A NEMA 1 ENCLOSURE WITH 120V COIL FOR CONTROL OF DISHWASHER EXHAUST FAN. RUN CONTROL WIRING FROM COIL CONTACTOR TO DISHWASHER FAN RELAY AND RUN FAN POWER CIRCUIT THROUGH CONTACTOR SO FAN IS ENERGIZED WHEN DISHWASHER IS IN OPERATION. COORDINATE WORK WITH EQUIPMENT MANUFACTURER. REFER TO ROOF POWER PLAN ON E106 FOR FAN LOCATION AND ADDITIONAL INFORMATION. 45 EXISTING TO REMAIN DOK-LOK SYSTEM. VERIFY WORKING CONDITION OF EQUIPMENT AND CIRCUIT AND NOTIFY THE FRESH MARKET PROJECT MANAGER OF ANY PROBLEMS. 46 CLEAR WORKING SPACE FOR ELECTRICAL EQUIPMENT. 47 NO JUNCTION BOXES OR PULL BOXES ARE TO BE INSTALLED ABOVE REFRIGERATION PIPING, SEE REFRIGERATION PIPING PLAN ON SHEET R102. 48 RLDS TO BE MOUNTED SO TOP IS AT 5' AFF. LCP TO BE MOUNTED ABOVE RLDS. 49 EXISTING TO REMAIN DOCK LIFT. VERIFY WORKING CONDITION OF EQUIPMENT AND CIRCUIT AND NOTIFY THE FRESH MARKET PROJECT MANAGER OF ANY PROBLEMS. 50 EXISTING TO REMAIN RECEPTACLE CIRCUIT WIRED TO CIRCUIT R2-34. 51 EXISTING TO REMAIN CONNECTION TO HEATER RH-1. VERIFY EXACT CIRCUIT AND UPDATE PANEL DIRECTORY AS NEEDED. 52 EXISTING TO REMAIN CONNECTIONS TO DE-STRATIFICATION FANS. VERIFY EXACT CIRCUIT AND UPDATE PANEL DIRECTORY AS NEEDED. 4 54.4 Z Y (E) SB CNTRL PANEL (E) LB(1) (E) LB(2) (E) LA (E) H (E) R1 (E) R2 (E) SC (E)T2 IG/84"SC-23 30 31 HSB-2 26 FACP R2-37 LSB-37 PA-15 84" R2-39 48 LB-68 G-1 G-3 49PG-14,16PG-18,20 G-25,27 HSB-4 (E) (E) (E) 46 EQUIPMENT CLEARANCE EQUIPMENT CLEARANCE 47 50 50 50 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y HUSSMANNQ3.5-SS-6RHUSSMANNQ3.5-SS- 4 R R HUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC R E F'G B E RR Y B I NSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12HUSSMANN IM-05-IN8-RHUSSMANNIM-05- E N 4 - R HILL PHOENIXSSGC-SSC-8 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D 48x18x60 L48x18x60 L48x18x60 L24x18x60 L WRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR LH U S S M A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R. MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RL HUSSMANN RL 4DR RL HUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC MEAL SOLUTIONS(WALK AROUND)HUSSMANNIM-04-E5-RH U S SM A NNIM-04-C6-RHUSSMANNIM - 0 4- C 6 - RHUSSMANNIM - 0 4 - C 6 - RHUSSMANNIM - 0 4 -C 6 - R HUSSMANQ4BV 10' RL HUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCLUDES 4'PRODUCE DRINKS6'RE F R IG E R A T E DWINE W/ WINEHOLDER20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK C ASE S 12' DRINKSHILL PHOENIXON5DM-NRG-12HILL PHOENIXON 5 D M-N RG-8 HILL PHOENIXON5DM-NRG-8HILL PHOE NI X ON5DM-NRG-12PASTASAUCE/SOUPS35PF CR MS 24" 6 PF-5 EWC PF-11,13 PF-16 10 PF-18 10 PF-3 PF-20 10 +45" PF-42 PF-34,36 40 PF-1 5 GF/48" DETAIL "A" 36 (TYP.) CR-11 IG CR-9 IG CR-7 IG CR-5 IG CR-3 IG CR-1 IG PF-22 PF-24 PF-26 PF-14 27 GF GF GF 5 +45" 48" GF PF-38,40 40 118" 118" 118" 24" PF-28 37 WG/24" 9 LB-28 PF-30 L6-20R L6-20R 24 GF/48" 40PF-17 42 42 PF-15 E105 3 E105 2 (E) P (E) G (N) HSB (R)LSB (R) 300kVA T1 NEW 1200 AMP, GFCI BREAKER IN NEMA 3R ENCLOSURE PDS DETAIL "A" SC-29 IG IG IG IG 28 PA-24(P)9 28 28 28 28 IG SC-31 7 PA-32,34,36 PA-28 PA-26 WG/54" L15-20 WG/54" PA-30 WG/54"WG/54"WG/54"14 G-29,31 30/2 PA-38,40,42 PA-25 34 7 L15-20 WG/54" WG/54" PA-31 PD-23 SC-39 PD-25 WG/56" WG/56" WG/56" PD-27 WG/56" PC-35,37 41 L14-20R PF-21 PF-23 PF-19 CR-21 IG/48" PF-44 PF-46 PF-48 E105 1 PF-9 PF-7 39 (4)-L6-15RPF-37,39 PF-33,35 PF-29,31 PF-25,27 CR-19 IG 1 PF-49,51 PF-53,55 PF-41,43(2)L14-20RPF-45,47 3917 21 PF-60 GF PB-29 PF-50 PF-54 PF-52 2 2 2 2 PF-58 18"PF-56 18" 20 PA-11 PA-13 PA-17 PA-24(P)9 USB/48" USB/48" USB/18" USB/18" 24"PA-9 GF/48" GF/48" GF/48" 25 29 29 USB/18" USB/18" GF/48" PA-7 20 24"GF 43 48" GF PA-3 +45" PA-21 EWC +45" PA-1 PA-5 5 +48" +48" 16 P-15,17,19 60/3 PA-22 WG/48" 13 LIGHTING INVERTER 4 G-12 B G-8(P) 9 LSB-16 44 4 L1-42 56" PA-656" E114 2 SC-20 IG/48" 56" PD-29 56" 9 PA-39,41 L14-20R L14-30R PC-28,30 23 IG SC-28 PD 49 (E)P-9,11,13 45 (E)G-26 G-4 18 18 G-6 18 G-2 G-10 19 G-8(P)9 G-14 11 PA-19 32 22 22 22 3 G-16 51 (E)G-24 (E) (E) (E) PA EMC OVERRIDE ALARM PANEL PA-2 SC-1 IG/48"ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 52 52 52 52 52 ETR DF-1 52 1. ALL EXPOSED CONDUIT SHALL BE ROUTED PARALLEL TO PERPENDICULAR TO THE STRUCTURE. ANY REQUIRED CHANGE OF DIRECTION SHALL BE 90 DEG. NO 45 DEG OR CROSS RUNS ARE ALLOWED. GENERAL NOTES SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana POWER PLAN E-104 BSD DSP 12/08/2021 02/07/22