Loading...
HomeMy WebLinkAboutE116_Fire Alarm Plan4 5 4.4 Z Y 1 FACP1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y B/CDOUBLECOMBI12GC/OSUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTY SALADSORDER F R R H R N H H H H R H 20' CHEESEDISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSSMANNQ3.5- S S - 4 RR HUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) SC R E F'G B E RR Y B I NSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12 HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANNIM - 05- E N 4 - R HONHC1872ATLANTIC FOOD BARSHHDD5136-TFM HILL PHOENIXSSGC-SSC-8 HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D48x18x60 L48x18x60 L48x18x60 L24x18x60 LWRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR L H U S SM A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R.MEN'S R.R. INSTACART ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLE BAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RLHUSSMANN RL 4DR RLHUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC ME A L S O L U T I O N S(WALK AROUND)HUSSMANNIM-04-E5-RHUSSMANNIM-04-C6-RH U S S M A N N I M - 0 4 - C 6 - R H U S S M A N N I M - 0 4-C 6 - R H U S S M A N N I M - 0 4 - C 6 - R HUSSMANQ4BV 10' RLHUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCL U D E S 4'PRODUCE DRINKS6'REFRIGERATEDWINE W/ WINEHOLDER20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK CA S ES 12' DRIN K S HILL PHOENIXON5DM-NRG-12HI L L PHOE N I X ON5DM-NRG-8HILL PHOENIXO N 5 D M-N RG-8HILL PHOENIXON5 D M- N R G -12 PASTASAUCE/SOUPS6 15CD 15CD 115CD 115CD 115CD 115CD 115CD115CD 15CD 15CD 75CD 75CD F F 30CD ANN 1 M 3 M M F 15CD 75CD 115CD 15CD 15CD 15CD F 75CD F F 75CD 75CD 30CD 30CD 30CD 30CD 30CD R R 5 5 SUPPLY SHUTDOWN RETURN SHUTDOWN R R5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN R R5 5 RETURN SHUTDOWNSUPPLY SHUTDOWN R R 5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN R R5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN R R5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN FIRE ALARM CONTROL PANEL. FIRE ALARM SYSTEM ANNUNCIATOR. HORN/STROBE - MOUNT 80" AFF TO CENTER - CANDELA RATING AS NOTED. STROBE - MOUNT 80" AFF TO CENTER - CANDELA RATING AS NOTED. SMOKE DETECTOR DUCT SMOKE DETECTOR - FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR, MOUNTED BY MECHANICAL CONTRACTOR. CEILING PENDANT MOUNTED HORN/STROBE, CANDELA RATING AS NOTED. CEILING PENDANT MOUNTED STROBE, CANDELA RATING AS NOTED. TEMPERATURE (HEAT) DETECTOR. SPRINKLER ALARM BELL. SPRINKLER VALVE TAMPER SWITCH. SPRINKLER FLOW SWITCH. FIRE ALARM MONITOR MODULE. FIRE ALARM CONTROL RELAY FIRE ALARM PULL STATION. R M F FIRE ALARM LEGEND FACP ANN 1. PROVIDE 200# NYLON PULLSTRING IN ALL EMPTY CONDUIT RACEWAYS. 2. PROVIDE PLASTIC BUSHINGS ON THE ENDS OF THE CONDUIT STUBS. 3. A COMPLETE FIRE ALARM SYSTEM FOR THE FRESH MARKET SHALL BE PROVIDED. 4. ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES AND ANY OTHER FIRE ALARM EQUIPMENT INCLUDING THE FIRE ALARM CONTROL PANEL SHALL BE U.L. APPROVED. 5. PENDANT MOUNTED NOTIFICATION APPLIANCES SHALL BE MOUNTED AT 14' AFF IN THE SALES AREA AND 9'-6" AFF IN REAR CORRIDOR AND RECEIVING AREAS. GENERAL NOTES KEY NOTES 1 PROPOSED LOCATION. COORDINATE FINAL LOCATION WITH THE FIRE CODE OFFICIAL & TFM. FACP SHALL BE FIRELITE OR SILENT KNIGHT. 2 FIRE ALARM MONITOR MODULE FOR HOOD FIRE SUPPRESSION SYSTEM. 3 COORDINATE LOCATION OF SPRINKLER SYSTEM FLOW AND TAMPER SWITCHES WITH SPRINKLER CONTRACTOR . 4 COORDINATE ANNUNCIATOR PANEL WITH AHJ AND TFM PROJECT MANAGER PRIOR TO ROUGH-IN. 5 DUCT SMOKE DETECTOR IN SUPPLY AND RETURN DUCTS, PROVIDED AND WIRED BY FIRE ALARM CONTRACTOR, INSTALLED IN DUCT BY MC. UPON ACTUATION, SMOKE DETECTOR SHALL SHUT DOWN THE HVAC UNIT AND SEND A SIGNAL TO THE BUILDING FIRE ALARM SYSTEM. REMOTE SIGNALING AND TEST/RESET STATION SHALL BE PROVIDED AND INSTALLED BY FIRE ALARM CONTRACTOR. TEST/REST STATION SHALL BE LOCATED IN AN ACCESSIBLE LOCATION, COORDINATE LOCATION WITH FIRE MARSHALL'S OFFICE PRIOR TO INSTALLATION. 6 FLOW SWITCHES AND TAMPER SWITCHES FOR SPRINKLER SYSTEM. VERIFY QUANTITIES AND LOCATIONS WITH SPRINKLER CONTRACTOR PRIOR TO INSTALLATION. PROVIDE MONITOR MODULES AS REQUIRED. 1. MONITOR MODULE FOR HOOD FIRE SUPPRESSION SYSTEM. 2. TYPICAL CONTROL RELAY AND DUCT DETECTOR FOR RTU FAN SHUTDOWN. 4. SPRINKLER FLOW AND TAMPER SWITCHES, REFER TO FIRE PROTECTION SHOP DRAWINGS FOR QUANTITIES AND LOCATIONS OF SPRINKLER FLOW AND TAMPER SWITCHES. 5. PROVIDE TWO TELEPHONE LINES FROM DACT TO TELEPHONE EQUIPMENT BACKBOARD FOR TERMINATION BY TELEPHONE SYSTEM INSTALLER. THE DACT SHALL BE PROGRAMMED TO CALL THE APPROVED CENTRAL STATION DESIGNATED BY TFM. M M SS 120V FACP EXTERIOR HORN STROBE IF REQUIRED BY AHJ. F SIGNALING LINE CIRCUIT, INSTALL 18G4C FPL WIRE NOTIFICATION APPLIANCE CIRCUITS, INSTALL 14G2C FPL WIRE SS REMOTE ANNUNCIATOR PANEL INSTALL 18G4C FPL WIRE M HS NOTE 1 15CD 15CD 75CD 75CD WP F F F M SS 15CD 15CD 15CD F F R R R R R R NOTE 3 NOTE 2 SSNOTE 4 F R RR R 15CD 15CD 15CD 30CD 30CD 30CD 30CD 30CD 75CD 75CD 75CD 115CD 115CD 115CD 75CD 75CD 75CD 75CD 115CD 115CD 115CD 115CD CONTROL UNIT ANNUNCIATOR ALARM NOTIFICATION FIRE SAFETY FUNCTIONS SUPPLEMENTARY ACTUATE ALARM SIGNAL ACTUATE TROUBLE SIGNAL ACTUATE SUPERVISORY SIGNAL ACTUATE GENERAL ALARM SHUTDOWN ROOF TOP UNITS ACTUATE REMOTE ANNUNCIATORS TRANSMIT ALARM SIGNAL TO SUPERVISINGSTATION . TRANSMIT TROUBLE SIGNAL TO SUPERVISINGSTATION TRANSMIT SUPERVISORY SIGNAL TOSUPERVISING STATION1 MANUAL STATION X X X X X 2 SMOKE DETECTOR - OTHER X X X X X 3 SPRINKLER SYSTEM WATERFLOW X X X X X 4 KITCHEN HOOD FIRE SUPPRSSSION RELEASE X X X X X 5 FIRE ALARM SYSTEM A/C POWER FAILURE X X X 6 FIRE ALARM SYSTEM LOW BATTERY X X X 7 OPEN CIRCUIT X X X 8 GROUND FAULT X X X 9 NOTIFICATION APPLIANCE SHORT CIRCUIT X X X 10 SPRINKLER SYSTEM VAVLE TAMPER X X X 11 SMOKE DETECTOR - DUCT X X 12 BUILDING OCCUPANCY/LOAD USE GROUP: M/S - NON-SEPARATED MIX USE M-MERCANTILE (PRIMARY) B-BUSINESS (ACCESSORY) S1-STORAGE (ACCESSORY) F1-KITCHENS (ACCESSORY) TOTAL OCCUPANT LOAD: 605 TENANT AREA: 24,569 S.F. SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana FIRE ALARM PLAN E-116 BSD DSP 12/08/2021 02/07/22