HomeMy WebLinkAboutE116_Fire Alarm Plan4 5 4.4
Z
Y
1
FACP1.4
1.4 1
1 2
2 2.1
2.5
2.5
3
3
3.5
3.5 3.9
4
4
5
5
5.4
5.4
6
6
4.4
B
C
D
E
F
G
A
Z
Y
B/CDOUBLECOMBI12GC/OSUSHI
12' CMS
SALADS
H
H
H
H
DELI
CHEESE
DISPLAY
TC
TC
R
CARVING
HOT
PICKUP
34"
AFF
SOUP
MTO SALADS
PREPARED
SPECIALTY
SALADSORDER
F
R
R
H
R
N
H H
H
H
R
H
20'
CHEESEDISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSSMANNQ3.5-
S
S
-
4
RR
HUSSMANNQ3.5-SS-90R
38x26x42UTILITY CART
RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)
SC
R
E
F'G
B
E
RR
Y
B
I
NSC REF'G BERRY BINSC REF'G BERRY BIN
SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12
HOBARTOV500G2-EE
HOBARTPW2E-41
TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP
HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANNIM
-
05-
E
N
4
-
R
HONHC1872ATLANTIC FOOD BARSHHDD5136-TFM
HILL PHOENIXSSGC-SSC-8
HONHC1872 HONHC1872
WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD
D
D
D
D48x18x60 L48x18x60 L48x18x60 L24x18x60 LWRAPPING BOARD
UP
UP
ID5SLID5SLID5SLID5SLR
L
H
U
S
SM
A
N
N
R
L
2
D
RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT &
SEAFOOD
COOLER
MEAT &
SEAFOOD
PREP
OFFICE
WOMEN'S
R.R.MEN'S R.R.
INSTACART
ENTRY/EXIT
VESTIBULE
FRONT END
CHECKOUT
AREA
FLORAL
SALES
PRODUCE
SALES
MEAT
SERVICE
AISLE BAKERY
SERVICE
AISLE
DAIRY
SALES
FROZEN
SALES
GROCERY
SALES
BEER AND
WINE SALES
BULK/COFFEE/CANDY
SALES
DELI PREP
RECEIVING
BOH
CORRIDOOR
FLORAL
COOLER
FLORAL
PREP
PRODUCE
COOLER
PRODUCE
PREP
KITCHEN
COLD
COOKED
PREP
COLD
COOKED
COOLER
SCULLERY
FIRE RISER
BAKERY
PREP
BAKERY
COOLER
DAIRY
COOLER
BREAK
ROOM
RESTROOM
RESTROOM
WELLNESS
ROOM
BULK
COOLER
ICE CREAM
FREEZER
BAKERY
DELI
GROCERY
FREEZER
MEAT &
SEAFOOD
FREEZER
ELECTRICAL
ROOM
RESTROOM
COORIDOR
RLHUSSMANN RL 4DR RLHUSSMANN RL 4DR
HILL PHOENIXBSD-SW-10RC-SSC
ME
A
L
S
O
L
U
T
I
O
N
S(WALK AROUND)HUSSMANNIM-04-E5-RHUSSMANNIM-04-C6-RH
U
S
S
M
A
N
N
I
M
-
0
4
-
C
6
-
R
H
U
S
S
M
A
N
N
I
M
-
0
4-C
6
-
R
H
U
S
S
M
A
N
N
I
M
-
0
4
-
C
6
-
R
HUSSMANQ4BV 10'
RLHUSSMANN RL 2DR
ID5SLR ID5SLR
ID5SL
12' S.S. REF. DELI/MEAT
CASE, 5-DK
3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCL
U
D
E
S 4'PRODUCE DRINKS6'REFRIGERATEDWINE W/ WINEHOLDER20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK CA
S
ES
12' DRIN
K
S
HILL PHOENIXON5DM-NRG-12HI L L PHOE
N
I
X
ON5DM-NRG-8HILL PHOENIXO N 5 D M-N RG-8HILL PHOENIXON5
D
M-
N
R
G -12 PASTASAUCE/SOUPS6
15CD
15CD
115CD 115CD 115CD
115CD 115CD115CD
15CD
15CD
75CD
75CD
F
F
30CD
ANN
1
M
3
M M
F
15CD
75CD
115CD
15CD 15CD
15CD
F
75CD
F
F
75CD
75CD
30CD
30CD
30CD
30CD 30CD
R
R
5
5
SUPPLY
SHUTDOWN
RETURN
SHUTDOWN
R
R5
5
RETURN
SHUTDOWN SUPPLY
SHUTDOWN
R
R5
5
RETURN
SHUTDOWNSUPPLY
SHUTDOWN
R
R 5
5
RETURN
SHUTDOWN
SUPPLY
SHUTDOWN
R
R5
5
RETURN
SHUTDOWN
SUPPLY
SHUTDOWN
R
R5
5
RETURN
SHUTDOWN
SUPPLY
SHUTDOWN
FIRE ALARM CONTROL PANEL.
FIRE ALARM SYSTEM ANNUNCIATOR.
HORN/STROBE - MOUNT 80" AFF TO CENTER - CANDELA
RATING AS NOTED.
STROBE - MOUNT 80" AFF TO CENTER - CANDELA RATING AS
NOTED.
SMOKE DETECTOR
DUCT SMOKE DETECTOR - FURNISHED AND WIRED BY
ELECTRICAL CONTRACTOR, MOUNTED BY MECHANICAL
CONTRACTOR.
CEILING PENDANT MOUNTED HORN/STROBE, CANDELA
RATING AS NOTED.
CEILING PENDANT MOUNTED STROBE, CANDELA RATING AS
NOTED.
TEMPERATURE (HEAT) DETECTOR.
SPRINKLER ALARM BELL.
SPRINKLER VALVE TAMPER SWITCH.
SPRINKLER FLOW SWITCH.
FIRE ALARM MONITOR MODULE.
FIRE ALARM CONTROL RELAY
FIRE ALARM PULL STATION.
R
M
F
FIRE ALARM LEGEND
FACP
ANN
1. PROVIDE 200# NYLON PULLSTRING IN ALL EMPTY CONDUIT RACEWAYS.
2. PROVIDE PLASTIC BUSHINGS ON THE ENDS OF THE CONDUIT STUBS.
3. A COMPLETE FIRE ALARM SYSTEM FOR THE FRESH MARKET SHALL BE PROVIDED.
4. ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES AND ANY OTHER FIRE
ALARM EQUIPMENT INCLUDING THE FIRE ALARM CONTROL PANEL SHALL BE U.L.
APPROVED.
5. PENDANT MOUNTED NOTIFICATION APPLIANCES SHALL BE MOUNTED AT 14' AFF IN
THE SALES AREA AND 9'-6" AFF IN REAR CORRIDOR AND RECEIVING AREAS.
GENERAL NOTES
KEY NOTES
1 PROPOSED LOCATION. COORDINATE FINAL LOCATION WITH THE
FIRE CODE OFFICIAL & TFM. FACP SHALL BE FIRELITE OR SILENT
KNIGHT.
2 FIRE ALARM MONITOR MODULE FOR HOOD FIRE SUPPRESSION
SYSTEM.
3 COORDINATE LOCATION OF SPRINKLER SYSTEM FLOW AND
TAMPER SWITCHES WITH SPRINKLER CONTRACTOR .
4 COORDINATE ANNUNCIATOR PANEL WITH AHJ AND TFM PROJECT
MANAGER PRIOR TO ROUGH-IN.
5 DUCT SMOKE DETECTOR IN SUPPLY AND RETURN DUCTS,
PROVIDED AND WIRED BY FIRE ALARM CONTRACTOR,
INSTALLED IN DUCT BY MC. UPON ACTUATION, SMOKE
DETECTOR SHALL SHUT DOWN THE HVAC UNIT AND SEND A
SIGNAL TO THE BUILDING FIRE ALARM SYSTEM. REMOTE
SIGNALING AND TEST/RESET STATION SHALL BE PROVIDED AND
INSTALLED BY FIRE ALARM CONTRACTOR. TEST/REST STATION
SHALL BE LOCATED IN AN ACCESSIBLE LOCATION, COORDINATE
LOCATION WITH FIRE MARSHALL'S OFFICE PRIOR TO
INSTALLATION.
6 FLOW SWITCHES AND TAMPER SWITCHES FOR SPRINKLER
SYSTEM. VERIFY QUANTITIES AND LOCATIONS WITH SPRINKLER
CONTRACTOR PRIOR TO INSTALLATION. PROVIDE MONITOR
MODULES AS REQUIRED.
1. MONITOR MODULE FOR HOOD FIRE SUPPRESSION SYSTEM.
2. TYPICAL CONTROL RELAY AND DUCT DETECTOR FOR RTU FAN SHUTDOWN.
4. SPRINKLER FLOW AND TAMPER SWITCHES, REFER TO FIRE PROTECTION
SHOP DRAWINGS FOR QUANTITIES AND LOCATIONS OF SPRINKLER FLOW AND
TAMPER SWITCHES.
5. PROVIDE TWO TELEPHONE LINES FROM DACT TO TELEPHONE EQUIPMENT
BACKBOARD FOR TERMINATION BY TELEPHONE SYSTEM INSTALLER. THE
DACT SHALL BE PROGRAMMED TO CALL THE APPROVED CENTRAL STATION
DESIGNATED BY TFM.
M
M
SS 120V
FACP
EXTERIOR HORN STROBE
IF REQUIRED BY AHJ.
F
SIGNALING LINE CIRCUIT,
INSTALL 18G4C FPL WIRE
NOTIFICATION
APPLIANCE CIRCUITS,
INSTALL 14G2C FPL
WIRE
SS
REMOTE
ANNUNCIATOR
PANEL
INSTALL 18G4C FPL WIRE
M
HS
NOTE 1
15CD 15CD 75CD
75CD
WP
F F F
M
SS
15CD 15CD 15CD
F F R R R R R R
NOTE 3
NOTE 2
SSNOTE 4
F
R RR R
15CD 15CD 15CD 30CD
30CD
30CD
30CD 30CD 75CD 75CD 75CD
115CD 115CD 115CD 75CD 75CD 75CD 75CD 115CD 115CD 115CD 115CD
CONTROL UNIT ANNUNCIATOR ALARM NOTIFICATION FIRE SAFETY FUNCTIONS SUPPLEMENTARY
ACTUATE ALARM SIGNAL ACTUATE TROUBLE SIGNAL ACTUATE SUPERVISORY SIGNAL ACTUATE GENERAL ALARM SHUTDOWN ROOF TOP UNITS ACTUATE REMOTE ANNUNCIATORS TRANSMIT ALARM SIGNAL TO SUPERVISINGSTATION . TRANSMIT TROUBLE SIGNAL TO SUPERVISINGSTATION TRANSMIT SUPERVISORY SIGNAL TOSUPERVISING STATION1 MANUAL STATION X X X X X
2 SMOKE DETECTOR - OTHER X X X X X
3 SPRINKLER SYSTEM WATERFLOW X X X X X
4 KITCHEN HOOD FIRE SUPPRSSSION RELEASE X X X X X
5 FIRE ALARM SYSTEM A/C POWER FAILURE X X X
6 FIRE ALARM SYSTEM LOW BATTERY X X X
7 OPEN CIRCUIT X X X
8 GROUND FAULT X X X
9 NOTIFICATION APPLIANCE SHORT CIRCUIT X X X
10 SPRINKLER SYSTEM VAVLE TAMPER X X X
11 SMOKE DETECTOR - DUCT X X
12
BUILDING OCCUPANCY/LOAD
USE GROUP: M/S - NON-SEPARATED MIX USE
M-MERCANTILE (PRIMARY)
B-BUSINESS (ACCESSORY)
S1-STORAGE (ACCESSORY)
F1-KITCHENS (ACCESSORY)
TOTAL OCCUPANT LOAD: 605
TENANT AREA: 24,569 S.F.
SHEET NO.
This drawing was prepared for use on a
specific site contemporaneously with its issue
date and it is not suitable for use on a
different project site or at a later time. Use of
this drawing for reference or example on
another project requires the services of
properly licensed architects and engineers.
Reproduction of this drawing for reuse on
another project is not authorized and may be
contrary to the law.
BRR Original printed on recycled paper
COPYRIGHT NOTICE
PROJECT NO.
SHEET TITLE
ISSUES & REVISIONS
DRAWN BY:
PROFESSIONAL SEAL
PROJECT MANAGER:
DOCUMENT DATE:
CHECKED BY:
PROJECT NAME
PROJECT ADDRESS
1 2 3 4 5 ABCDEABCDE12 3 4 5
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
ARCHITECT OF RECORD:
62930563
12/07/2021
THE FRESH
MARKET
The Centre Retail Center
NO. DATE DESCRIPTION
An Erdman Anthony Company
552 Fort Evans RD STE 200
Leesburg, VA 20176
703.777.5988
Leesburg@erdmananthony.com
116th St. and Rangeline Rd.
Carmel, Indiana
FIRE ALARM
PLAN
E-116
BSD
DSP
12/08/2021
02/07/22