HomeMy WebLinkAboutEM102_Energy Management Control Riser Diagram and NotesSHEET NO.
This drawing was prepared for use on a
specific site contemporaneously with its issue
date and it is not suitable for use on a
different project site or at a later time. Use of
this drawing for reference or example on
another project requires the services of
properly licensed architects and engineers.
Reproduction of this drawing for reuse on
another project is not authorized and may be
contrary to the law.
BRR Original printed on recycled paper
COPYRIGHT NOTICE
PROJECT NO.
SHEET TITLE
ISSUES & REVISIONS
DRAWN BY:
PROFESSIONAL SEAL
PROJECT MANAGER:
DOCUMENT DATE:
CHECKED BY:
PROJECT NAME
PROJECT ADDRESS
1 2 3 4 5 ABCDEABCDE12 3 4 5
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
ARCHITECT OF RECORD:
62930563
12/07/2021
THE FRESH
MARKET
The Centre Retail Center
NO. DATE DESCRIPTION
An Erdman Anthony Company
552 Fort Evans RD STE 200
Leesburg, VA 20176
703.777.5988
Leesburg@erdmananthony.com
116th St. and Rangeline Rd.
Carmel, Indiana
ENERGY
MANAGEMENT
CONTROL
RISER & NOTES
EM102
BSD
NGS
1. ALL SOLID LINES ARE FIELD WIRING, UNLESS OTHERWISE NOTED. ALL DASHED WIRING IS EITHER EXISTING OR FACTORY
INSTALLED.
2. DAYTON AIR SWITCH (2E462) IS TO BE WIRED IN ADDITION TO ANY OTHER SWITCHES LOCATED IN ELECTRIC DUCT
HEATERS (IF APPLICABLE).
3. SPACE TEMPERATURE SENSORS AND DEWPOINT TEMPERATURE SENSORS ARE TO BE LOCATED ON COLUMNS OR
RECESSED IN WALLS IN THE CENTER OF THE AREAS SERVED AND MOUNTED AT 84" A.F.F. COORDINATE WITH THE
ELECTRICAL (E) AND MECHANICAL (M) PLANS BY BRANDT ENGINEERING, INC.
4. SUPPLY AIR TEMPERATURE SENSORS ARE TO BE LOCATED A MINIMUM OF 6’ DOWNSTREAM OF DUCT HEATERS.
5. ALL SHIELDED WIRES USED FOR SENSORS SHALL BE CUT OFF AND TAPED BACK ON THE SENSOR END OF THE WIRE. THE
SHIELD SHALL BE GROUNDED TO THE GROUND LUG PROVIDED IN THE MAIN PANEL.
6. ALL CONTROL WIRES SHALL BE A MINIMUM OF 14 AWG (STRANDED), SHIELDED CABLES SHALL BE A MINIMUM OF 22 AWG.
ALL WIRING TO BE IN CONDUIT PROVIDED AND INSTALLED BY EC. POWER WIRING SHALL NOT BE RUN IN THE SAME
CONDUIT AS CONTROL WIRING.
7. INSTALLATION SHALL MEET ALL LOCAL, STATE, AND NATIONAL CODES AND IS THE RESPONSIBILITY OF THE INSTALLING
CONTRACTOR.
8. NETWORK COMMUNICATIONS CABLE MUST BE DAISY CHAINED. NO T-TAPPING IS ACCEPTABLE.
9. REFER TO PLAN EM103 FOR LIGHTING/EQUIPMENT RELAY CONTROL INPUT/OUTPUT SCHEDULES. REFER TO ELECTRICAL
(E) PLANS BY BRANDT ENGINEERING, INC. FOR LIGHTING AND EQUIPMENT CONTACTOR SCHEDULE.
1. THE CONTROLLER INPUT/OUTPUT BOARDS SHOWN ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO CONVEY
THE TYPICAL INSTALLATION WIRING REQUIREMENTS. SEE THE CPC CONTROL EQUIPMENT LIST FOR THE ACTUAL
INPUT/OUTPUT BOARD COUNT.
2. IT IS THE RESPONSIBILITY OF THE REM TO PROVIDE THE SPECIFIED PREWIRED INPUT AND OUTPUT BOARDS AS
SHOWN ON PLAN EM103 WITH THE PREWIRED INPUTS AND OUTPUTS AS SPECIFIED IN THE REFRIGERATION
EQUIPMENT SPECIFICATIONS FOR ALL REFRIGERATION EQUIPMENT. THE REM SHALL COORDINATE ANY
DISCREPANCIES WITH ochsrterEFS, p.c. PRIOR TO FABRICATION OF EQUIPMENT.
3. ALL LOOSE CPC AND EMC COMPONENTS FOR REFRIGERATION CONTROL TO BE FURNISHED BY THE REM AS
SPECIFIED WITHIN THE REFRIGERATION EQUIPMENT SPECIFICATIONS.
4. ALL LOOSE CPC AND EMC COMPONENTS FOR MECHANICAL AND LIGHTING CONTROL TO BE FURNISHED BY THE REM
AS SPECIFIED WITHIN THE REFRIGERATION EQUIPMENT SPECIFICATIONS.
5. REFER TO THE REFRIGERATION INSTALLATION SPECIFICATIONS AND REFRIGERATION EQUIPMENT SPECIFICATIONS
FOR INFORMATION REGARDING THE ENERGY MANAGEMENT SYSTEM.
6. REFER TO MECHANICAL (M) PLANS BY BRANDT ENGINEERING, INC. FOR MECHANICAL EQUIPMENT LOCATIONS.
1. THE RIC SHALL COORDINATE WITH THE FIRE ALARM CONTRACTOR AND MECHANICAL CONTRACTOR ON FINAL SEQUENCE
OF OPERATIONS FOR SHUTDOWN OF MECHANICAL UNITS.
2. ONCE THE MODIFIED EXISTINS CPC E2 BX-400E MECHANICAL/LIGHTING CONTROL SYSTEM HAS BEEN INSTALLED AND THE
MECHANICAL SYSTEMS ARE READY TO BE BROUGHT ONLINE, THE MC & RIC MUST PROVIDE THE NECESSARY SUPERVISION
FOR THE START-UP OF THE CONTROL SYSTEM. THE MC & RIC MUST ENSURE THAT ALL OF THE MECHANICAL SYSTEMS ARE
OPERATING CORRECTLY AND PROVIDE ANY FINE TUNING OF THE SYSTEMS THAT IS REQUIRED.
3. REFER TO ALL NOTES FOR REFRIGERATION INSTALLATION CONTRACTOR AND REFRIGERATION EQUIPMENT
MANUFACTURER.
1. THE RIC SHALL BE RESPONSIBLE FOR SUPERVISING THE COMPLETE INSTALLATION OF THE ENERGY MANAGEMENT SYSTEM. THIS SHALL INCLUDE, BUT NOT
BE LIMITED TO, THE START-UP, PUNCHDOWN, AND PROGRAMMING OF THE ENTIRE REFRIGERATION CONTROL SYSTEM, MECHANICAL CONTROL SYSTEM,
AND LIGHTING/ EQUIPMENT CONTROL SYSTEM.
2. THE RIC SHALL PROVIDE AND INSTALL ALL NECESSARY NETWORK COMMUNICATION, SENSOR, AND CONTROL WIRING IN THE CONDUIT RACEWAY SYSTEM
PROVIDED AND INSTALLED BY THE EC FOR ALL CONTROL EQUIPMENT FOR REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS.
RIC SHALL BE RESPONSIBLE FOR SHIELDED CABLE AND CONTROL WIRE CONDUCTORS TO ALL DEVICES LISTED ON THE ENERGY MANAGEMENT (EM) PLANS
AS REQUIRED FOR A COMPLETE INSTALLATION. THE RIC SHALL COORDINATE AND RESOLVE ALL CONDUIT RACEWAY DISCREPANCIES WITH THE EC.
3. THE RIC SHALL PROVIDE AND INSTALL ALL NECESSARY TUBING FOR THE CPC IRLDSII REFRIGERANT LEAK DETECTION SYSTEM. THE RIC SHALL BE
RESPONSIBLE FOR ALL TUBING AND ASSOCIATED SUPPORTS FROM THE CONTROLLER TO ALL DEVICES LISTED ON THE ENERGY MANAGEMENT (EM) PLANS
AS REQUIRED FOR A COMPLETE INSTALLATION.
4. THE RIC SHALL PROVIDE AND INSTALL ALL CONTROL WIRING BETWEEN THE RTU UNITS AND THE CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH
WEATHERPROOF ENCLOSURES IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL TERMINATIONS OF THE CONTROL WIRING AT
CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES AND TO THE RTU UNITS SHALL BE BY THE RIC.
5. THE RIC SHALL PROVIDE ALL COORDINATION BETWEEN THE VARIOUS TRADES, INCLUDING MECHANICAL AND ELECTRICAL, TO ENSURE THAT ALL
EQUIPMENT IS PROPERLY CONTROLLED AND THAT ALL CONTROL POINTS HAVE BEEN ACCOMMODATED. THIS SHALL INCLUDE VERIFYING ALL MECHANICAL
EQUIPMENT TO BE CONTROLLED, VERIFYING ALL STAGES OF HEATING, COOLING, HEAT RECLAIM, FANS, ETC. AND ENSURING THAT ADEQUATE SENSORS
HAVE BEEN SUPPLIED TO ENABLE PROPER CONTROL OF SAME.
6. UPON COMPLETION OF THE EMS INSTALLATION, THE RIC SHALL PROVIDE ACCURATE AND COMPLETE AS-BUILT DOCUMENTATION TO THE OWNER AND THE
ENGINEER. THIS DOCUMENTATION MUST INCLUDE AN 8-1/2" x 11" PLAN INDICATING THE LOCATIONS OF ALL OF THE SENSORS, RELAYS, REMOTE
INPUT/OUTPUT BOARDS, CONTROLLERS, AND MODEM FOR THE REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS.
7. THE RIC SHALL FURNISH AND INSTALL A 48* x 36" PLAN WITH FRAME AND CLEAR PLEXI-GLASS COVER SHOWING THE FINAL LOCATIONS OF ALL OF THE
REFRIGERATION CIRCUITS HIGHLIGHTED FOR EACH CORRESPONDING PARALLEL COMPRESSOR RACK. THIS PLAN SHALL BE PLACED IN THE EXISTING
MEZZANINE MOTOR ROOM.
8. REFER TO ALL NOTES FOR REFRIGERATION EQUIPMENT MANUFACTURER
1. THE EC SHALL PROVIDE AND INSTALL ALL NECESSARY POWER FOR ALL CONTROL EQUIPMENT FOR REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT
CONTROL SYSTEMS. EC SHALL BE RESPONSIBLE FOR CONDUIT RACEWAYS AND POWER WIRE CONDUCTORS TO ALL DEVICES LISTED ON ENERGY
MANAGEMENT (EM) PLANS AS REQUIRED FOR A COMPLETE INSTALLATION.
2. THE EC SHALL PROVIDE AND INSTALL ALL NECESSARY CONDUIT RACEWAYS WITH PULL STRINGS FOR NETWORK COMMUNICATION, SENSOR, AND CONTROL
WIRING FOR ALL CONTROL EQUIPMENT FOR REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS AS FOLLOWS FOR THE
APPROPRIATE LOCATIONS:
UNDERGROUND: PVC CONDUIT WITH RIGID 90° CONDUIT TRANSITIONS THROUGH ALL CONCRETE SLABS.
INTERIOR OVERHEAD AND ABOVE GRADE CONCEALED/EXPOSED: E.M.T. CONDUIT WITH COMPRESSION FITTINGS AND NEMA 1
JUNCTION BOXES/WIRING TROUGHS. FLEXIBLE METALLIC CONDUIT RACEWAYS NO GREATER THAN 6' IN LENGTH SHALL BE UTILIZED FOR ALL FINAL
EQUIPMENT CONNECTIONS WHERE FLEXIBILITY IS REQUIRED.
EXTERIOR AND INTERIOR WITHIN WALK-IN COOLERS/WALK-IN FREEZERS/REFRIGERATED PREP ROOMS: RIGID CONDUIT WITH
THREADED FITTINGS AND NEMA 3R JUNCTION BOXES. WEATHERPROOF FLEXIBLE CONDUIT RACEWAYS NO GREATER THAN 6' IN LENGTH
SHALL BE UTILIZED FOR ALL FINAL EQUIPMENT CONNECTIONS WHERE FLEXIBILITY IS REQUIRED.
EC SHALL BE RESPONSIBLE FOR THE CONDUIT RACEWAYS TO ALL DEVICES LISTED ON ENERGY MANAGEMENT (EM) PLANS AS REQUIRED FOR A COMPLETE
INSTALLATION.
3. THE EC SHALL PROVIDE ALL COMPONENTS AS REQUIRED FOR THE COMPLETE INSTALLATION OF THE LIGHTING/EQUIPMENT CONTROL SYSTEM. INSTALLATION
SHALL INCLUDE, BUT NOT BE LIMITED TO, FURNISHING AND INSTALLING ALL LOOSE MECHANICAL/LIGHTING CONTROL CONTACTORS. SEE
LIGHTING/EQUIPMENT CONTROL REQUIREMENTS ON ELECTRICAL (E) PLANS BY BRANDT ENGINEERING, INC. FOR LIGHTING AND EQUIPMENT CONTACTOR
SCHEDULE.
4. THE EC SHALL BE RESPONSIBLE FOR ALL CONDUIT RACEWAYS AND POWER WIRE CONDUCTORS TO EACH REFRIGERATION SYSTEM AS SPECIFIED.
5. REFER TO ALL NOTES FOR REFRIGERATION INSTALLATION CONTRACTOR AND REFRIGERATION EQUIPMENT MANUFACTURER.
1. THE REM SHALL FURNISH AND FACTORY INSTALL THE CPC CONTROLS IN THE NEW PARALLEL COMPRESSOR RACK CONTROL PANELS AS SPECIFIED. THE INSTALLATION SHALL INCLUDE, BUT NOT
BE LIMITED TO, THE INSTALLATION OF THE COPELAND INTELLIGENT STORE DISCUS 2.1 CONTROLS (CORESENSE DIAGNOSTICS), CPC MULTI-FLEX INPUT/OUTPUT BOARDS, CPC MULTI-FLEX ESR8
BOARDS, POWER SUPPLY, PRESSURE TRANSDUCERS, RECEIVER LEVEL TRANSDUCERS, TEMPERATURE SENSORS, POWER, AND CONTROL WIRING FROM THE CONTROL SYSTEM TO CONTROL
DEVICES MOUNTED ON THE RACK, LOCAL RS485 COMMUNICATION, SENSOR, AND CONTROL WIRING BETWEEN INPUT/OUTPUT BOARDS (BELDEN #8761-2 #22 SHIELDED CABLE), AND ALL FINAL
CONNECTIONS AS REQUIRED FOR A COMPLETE CONTROL SYSTEM. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT
RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
2. THE REM SHALL FURNISH THE REQUIRED LOOSE CPC PRESSURE TRANSDUCERS AND TEMPERATURE SENSORS FOR THE MODIFICATION OF THE EXISTING PARALLEL COMPRESSOR RACK. THE RIC
SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THESE COMPONENTS ON THE RACK INCLUDING ALL POWER, LOCAL RS485 COMMUNICATION (BELDEN #8761-2 #22 SHIELDED CABLE), SENSOR,
AND TRANSDUCER WIRING INSTALLATION AND TERMINATION REQUIRED. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE
CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
3. THE REM SHALL FURNISH AND FACTORY INSTALL THE CPC CONTROLS IN THE NEW ELECTRIC DEFROST PANEL AND NEW ROOFTOP AIR-COOLED CONDENSER AS SPECIFIED. THE INSTALLATION
SHALL INCLUDE, BUT NOT BE LIMITED TO, THE INSTALLATION OF THE CPC MULTI-FLEX INPUT/OUTPUT BOARDS, TRANSFORMERS, POWER SUPPLIES, AND CONTROL WIRING FROM THE CONTROL
SYSTEM TO CONTROL DEVICES MOUNTED ON THE NEW ELECTRIC DEFROST PANEL AND NEW ROOFTOP AIR-COOLED CONDENSER, LOCAL RS485 COMMUNICATION WIRING BETWEEN
INPUT/OUTPUT BOARDS (BELDEN #8761-2 #22 SHIELDED CABLE), AND ALL FINAL CONNECTIONS AS REQUIRED TO COMPLETE THE CONTROL SYSTEM. ALL FIELD COMMUNICATION AND CONTROL
WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
4. THE REM SHALL FURNISH THE REQUIRED LOOSE CPC WIRELESS GATEWAY RECEIVER, CPC IRLDS II CONTROLLER, EMC REFRIGERANT LEAK DETECTION CONTROL PANEL (LDCP), AND EMC
OVERRIDE/ALARM FOR REFRIGERATION AND LIGHTING CONTROL TO THE RIC FOR INSTALLATION. THE RIC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE CPC WIRELESS GATEWAY
RECEIVER, CPC IRLDS II CONTROLLER, EMC REFRIGERANT LEAK DETECTION CONTROL PANEL (LDCP), AND EMC OVERRIDE/ALARM PANEL FOR THE COMPLETE INSTALLATION OF THE
REFRIGERATION AND LIGHTING CONTROL SYSTEMS. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY
SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FIELD TUBING AND ASSOCIATED SUPPORTS SHALL BE PROVIDED AND INSTALLED BY THE RIC. ALL FINAL CONNECTIONS BY THE RIC.
5. THE REM SHALL FURNISH THE REQUIRED LOOSE CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH ENCLOSURES, CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES;
SPACE, SUPPLY AIR, RETURN AIR, AND SUCTION TEMPERATURE SENSORS; DEWPOINT TEMPERATURE SENSORS, AND DOMESTIC WATER HEATER TEMPERATURE SENSOR FOR THE COMPLETE
INSTALLATION OF THE MECHANICAL CONTROL SYSTEM. THE RIC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH ENCLOSURES, ALL CPC
MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES; SPACE, SUPPLY AIR, RETURN AIR, AND SUCTION TEMPERATURE SENSORS; DEWPOINT TEMPERATURE SENSORS, AND
DOMESTIC WATER HEATER TEMPERATURE SENSOR FOR THE COMPLETE INSTALLATION OF THE MECHANICAL CONTROL SYSTEM. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING
SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
6. THE CPC TEMPERATURE SENSORS FOR THE SPECIFIED DELFIELD REFRIGERATED CASES SHALL BE FURNISHED BY THE REM TO THE RIC FOR INSTALLATION. ALL FIELD SENSOR WIRING SHALL BE
PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
7. THE CPC WIRELESS TEMPERATURE SENSORS FOR THE SELF-CONTAINED REFRIGERATED CASES SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION.
8. THE CPC TEMPERATURE SENSORS FOR THE WALK-IN COOLERS, WALK-IN FREEZERS, AND REFRIGERATED PREP ROOMS SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION.
ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
9. THE CPC IRLDS II END FILTERS FOR THE REFRIGERANT LEAK DETECTION SYSTEM FOR THE WALK-IN COOLERS, WALK-IN FREEZERS, ENCLOSED REFRIGERATED PREP ROOMS, MEZZANINE MOTOR
ROOM, RETURN AIR DUCT, AND AMBIENT PURGE SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD TUBING AND ASSOCIATED SUPPORTS SHALL BE PROVIDED
AND INSTALLED BY THE RIC. ALL FINAL CONNECTIONS BY THE RIC.
10. THE EMC REFRIGERANT LEAK INDICATORS FOR THE REFRIGERANT LEAK DETECTION SYSTEM FOR THE WALK-IN COOLERS, WALK-IN FREEZERS, ENCLOSED REFRIGERATED PREP ROOMS, AND
MEZZANINE MOTOR ROOM SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT
RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
11. THE EMC DOOR MONITORING ALARMS FOR THE WALK-IN FREEZERS SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND
INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC.
12. THE CPC AMBIENT TEMPERATURE SENSORS SHALL BE FURNISHED BY THE REM AND FIELD INSTALLED BY THE RIC. ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN
THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY RIC.
1. THE REFRIGERATION CASE MANUFACTURER SHALL FURNISH ALL REFRIGERATED CASE FIXTURES NOTED WITH CPC TEMPERATURE SENSORS.
2. THE REFRIGERATION CASE MANUFACTURER SHALL FURNISH ALL REFRIGERATED CASE FIXTURES NOTED WITH CPC DEFROST TERMINATION TEMPERATURE
SENSORS.
WIRE TYPES:
WIRING SCHEDULE AND LEGEND
1 - BELDEN #8761 (2 #22 SHIELDED CABLE)
2 - BELDEN #8760 (2 #18 SHIELDED CABLE)
3 - BELDEN #8771 (3 #22 SHIELDED CABLE)
4 - BELDEN #8729 (4 #22 SHIELDED CABLE)
5 - 2 #14
6 - 2 #12
7
8 - 480V, 3Ø, DEDICATED POWER BY EC
9 - ECHELON NETWORK WIRING. ONE (1) PAIR CPC PART
#135-2300 (NON-PLENUM) AND #135-2301 (PLENUM)
- 120V, 1Ø, DEDICATED POWER BY EC
ALL CONDUIT AND POWER WIRING FURNISHED BY EC. ALL 120V/1Ø OR
208V/1Ø CONTROL WIRING SHALL BE IN CONDUIT. ALL LOW VOLTAGE
CONTROL/SENSOR WIRING SHALL BE IN CONDUIT. THE 120V/1Ø OR
208V/1Ø CONTROL WIRING SHALL NOT BE RUN IN THE SAME CONDUIT AS
THE LOW VOLTAGE CONTROL/SENSOR WIRING.
CABLE LEGEND:
WIRING INSTALLED BY
THE EC IN CONDUIT
WIRING FACTORY
INSTALLED
NOTES:
SYMBOL DESCRIPTION
MF168 CPC INPUT (16) / RELAY OUTPUT (8) BOARD
8R0 CPC (8) RELAY OUTPUT BOARD
MF88 CPC INPUT (8) / RELAY OUTPUT (8) BOARD
ESR CPC MULTI-FLEX ESR BOARD
ELECTRICAL CONTRACTOR
MF168AO CPC INPUT (16) / RELAY OUTPUT (8), ANALOG
OUTPUT (4) BOARD
EMS WIRE TYPE1
CPC INPUT (16) BOARDMF16
EC
10 - CAT 5E CABLE BY TFM DATA WIRING CONTRACTOR.
CSPM CORESENSE PROTECTION MODULE MOUNTED
ON EACH RACK COMPRESSOR
8
RTU-1
MF168AO
(FACTORY
INSTALLED)
ALL COMPONENTS WITHIN
FACTORY INSTALLED AND
PREWIRED.
MF168AO
MF168
MF168
RS485 I/O
NETWORK A
E2
CONTROLLER
CX-300
#1
1 2 3
4 5 6
7 8 9
. 0 -
2EEINSTEIN
MF168
8
ALL COMPONENTS WITHIN
FACTORY INSTALLED AND
PREWIRED.
RACK PANEL "B"
MF168AO
MF168
MF168
RACK PANEL "A"
1
1
PRODIGY
PRODIGY
MF88
7
TFM BACKROOM HUB
10
PHONE LINE
10
LEAK DETECTION
8R0
ALL COMPONENTS
WITHIN FACTORY
INSTALLED AND
PREWIRED.
REFRIGERATION LEAK
DETECTION SYSTEM
(RLDS)
8RO
REFRIGERATION
1
8RO
CONTROL PANEL
8RO
CONDENSER 'B'
(FACTORY
INSTALLED)
(FACTORY
INSTALLED)
CONDENSER 'A'
CSPM
CSPMCSPM
CSPM
CSPM
CSPM
RS485
MODBUS
NETWORK
1
MF88
MF88
1
E2
CONTROLLER
RX-300
#2
1 2 3
4 5 6
7 8 9
. 0 -
2EEINSTEIN
RS485 I/O
NETWORK A
RS485
MODBUS
NETWORK
MF88
MEAT CASE #1
(FACTORY
INSTALLED)
MF88
MEAT CASE #2
(FACTORY
INSTALLED)
1
MF88
MEAT CASE #3
(FACTORY
INSTALLED)
1
MF88
MEAT CASE #4
(FACTORY
INSTALLED)
1
MF88
MEAT CASE #5
(FACTORY
INSTALLED)
1
1
1
1
1
RS485
MODBUS
COM4A COM4A
COM4B
10
1
PANEL 'LA'
PANEL 'LB'
(SECTION 1)
PANEL 'LB'
(SECTION 2)
PLM
PLM
PLM
4
4
12/08/2021
02/07/22