Loading...
HomeMy WebLinkAboutEM104_Energy Management Control DetailsSHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT CONTROL DETAILS EM104 BSD NGS DEFROST BREAKER OR FUSES DEFROST CONTACTOR DEFROST RELAY DEFROST BREAKER OR FUSES DEFROST CONTACTOR SYSTEM SWITCH DEFROST LIGHT NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. 1 PHASE DEFROST (AS REQUIRED) (ONE PER CASE) PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. PRE-WIRED IN DEFROST PANEL. ESR VALVE (AT RACK OR REMOTE LOCATION) TO ESR BOARD LOW VOLTAGE TEMP PROBE FOR DEFROST TERM. (ONE PER CASE) TEMP PROBE (ONE PER CASE) TO MF168 INPUT BOARD ANALOG INPUT (AI) TO MF168 INPUT BOARD ANALOG INPUT (AI) NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. DEFROST BREAKER OR FUSES DEFROST CONTACTOR DEFROST RELAY SYSTEM SWITCH DEFROST LIGHT PRE-WIRED PANEL LOCATED IN DEFROST PANEL. LOW TEMP PROBE FOR DEFROST TERM. (ONE PER EVAP COIL) TEMP PROBE (ONE PER WALK-IN) TO MF168 INPUT BOARD ANALOG INPUT (AI) TO MF168 INPUT BOARD ANALOG INPUT (AI) NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. DEFROST HEATER FAN DELAY DOOR SWITCH TO MF168 INPUT BOARD DIGITAL INPUT (DI) DEFROST HEATER FAN DELAY FAN RELAY FAN BREAKER OR FUSES FAN NOTE: VERIFY ALL CONNECTIONS WITH CASE WIRING DIAGRAMS. SWITCH BY E.C. MOUNT ON UNIT COIL. NOTE: VERIFY ALL CONNECTIONS WITH CASE WIRING DIAGRAMS. NOTE: VERIFY ALL PANEL DIAGRAMS. BREAKER OR FUSES DEFROST CONTACTOR DEFROST RELAY SYSTEM SWITCH DEFROST LIGHT PRE-WIRED PANEL LOCATED IN DEFROST PANEL. NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. TEMP PROBE FOR DEFROST TERM. (ONE PER EVAP COIL) LOW VOLTAGE TEMP PROBE (ONE PER WALK-IN) TO MF168 INPUT BOARD ANALOG INPUT (AI) TO MF168 INPUT BOARD ANALOG INPUT (AI) DEFROST HEATER FAN DELAY FAN RELAY FAN CONTACTOR FAN BREAKER OR FUSES NOTE: VERIFY ALL CASE WIRING DIAGRAMS. CONNECTIONS WITH PANEL DIAGRAMS. NON-ESR VALVE (AT RACK OR REMOTE LOCATION) PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. ESR VALVE (AT RACK OR REMOTE LOCATION) TO ESR BOARD NON-ESR VALVE (AT RACK OR REMOTE LOCATION) PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. TO ESR BOARD NON-ESR VALVE (AT RACK OR REMOTE LOCATION) ESR VALVE (AT RACK OR REMOTE LOCATION) 1 PHASE DEFROST DEFROST HEATER FAN DELAY TO MF168 OUTPUT BOARD TO MF168 OUTPUT BOARD TO MF168 OUTPUT BOARD 2 POLE WP SERVICE SWITCH BY E.C. MOUNT ON UNIT COIL. ANTI-SWEAT HEATER (IF REQUIRED) TO CIRCUIT BREAKER IN ELECTRICAL PANEL PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. LOW VOLTAGE TEMP PROBE (ONE PER CASE) TO MF168 INPUT BOARD ANALOG INPUT (AI) NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. TO ESR BOARD NON-ESR VALVE (AT RACK OR REMOTE LOCATION) ESR VALVE (AT RACK OR REMOTE LOCATION) TO MF168 OUTPUT BOARD NOTES: 1. HEAT TRACE CABLE, SELF LIMITING TYP FOR FREEZER PROTECTION, WITH PARALLEL CONNECTED HEATER ZONES, 5 WATT/FT., 120V, SIMILAR AND EQUAL TO RAYCHEM 5XL-1. VERIFY WITH REFRIGERATION CONTRACTOR MODEL OF HEAT TRACE TAPE AND INSTALLATION REQUIREMENTS. 2. 7.9" PITCH WILL REQUIRE 1.2" CABLE/FT. PIPE. 3. INSULATION TO BE INSTALLED BY REFRIGERATION CONTRACTOR. 4 FOR USE IN ALL FREEZERS AND MEAT COOLERS. 5 HEAT TRACE TAPE SUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. 6 REFER TO SPECIFICATIONS FOR TYPICAL ROUTING. 3/4" INSULATION TRAP STANDPIPE DRAINAGE TUBE NYLON TIES TIE WRAP ICE CREAM ICE CREAM ICE CREAM HEAT TRACE CABLE TO BE EXTENDED FOR FULL LENGTH OF DRAIN PIPE POWER CONNECTION FLEX CONDUIT (SEE RAYCHEM INSTALLATION GUIDE). NEMA 4X VAPOR PROOF JUNCTION BOX. FREEZER WALL RIGID P.V.C. CONDUIT, INSTALL #12 GROUND WIRE WITH OTHER CONDUCTORS. PACK CONDUIT TIGHTLY WITH FIBERGLASS INSULATION. SEAL BOTH ENDS WITH DUCT SEAL. TO GFCI CIRCUIT BREAKER WITH 30mA TRIP SETTING (TYPICAL FOR ALL HEAT TRACE CIRCUITS). EVAPORATOR *PLASTIC FLUSH SWITCH BOXES AND PVC CONDUIT INSTALLED AT FACTORY. ALL CONDUIT TO BE INSTALLED INSIDE FREEZER. NOTE: 1 . FLOOR FREEZER DOOR LIGHTING FIXTURE MOUNTED INSIDE FREEZER CONNECT TO DOOR TRIM HEATER 120V POWER FOR FREEZER DOOR HEATER JUNCTION BOX MOUNTED ON TOP OF FREEZER * PRESS SWITCH WITH A PRESS PILOT LIGHT. FACTORY INSTALLED CONDUIT CONNECT TO PRESSURE RELIEF LOUVERS JUNCTION BOX MOUNTED ON TOP OF FREEZER 120V POWER SOURCE INSULATION DOOR SWITCH\STROBE\HORN FLOOR COMPRESSOR ROOM FROM HORN/STROBE TO REFRIGERATION CONTROL PANEL. SEE SHEET RC101. VOLTAGE SURFACE MOUNTED EMC-RLI 24V STROBE LIGHT AND HORN PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER AND INSTALLED BY RC. RIC TO PROVIDE AND INSTALL PARKER PARAFLEX SERIES FRPE 1/4" SENSING TUBING FROM RLDS UNIT TO THE END OF THE REFRIGERATION RACK CLOSEST TO THE EXHAUST FAN. FILTER PROVIDED WITH RLDS UNIT. CONTACTOR 2 POLE WP SERVICE CONNECTIONS WITH DEFROST INTAKE HOOD EXHAUST FAN COMPRESSOR RACK FLOOR OR PREP DOOR CONNECTIONS WITH NOTE: VERIFY ALL NOTE: EC SHALL PROVIDE JUNCTION BOXES AND CONDUIT PER DIRECTION OF THE RC. FROM DOOR SWITCH CONTACTS TO EMS CONTROL SYSTEM. SEE SHEET RC101. (COOLERS, FREEZERS & PREP ROOMS) SURFACE MOUNTED EMC-RLI 24V STROBE LIGHT AND HORN PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER AND INSTALLED BY RC ON PRE-INSTALLED JUNCTION BOX CENTERED ABOVE DOOR. IF WALK-IN OR PREP DOOR OPENS OUT INTO A SPACE VISIBLE TO THE PUBLIC, EMC-RLI UNIT TO BE INSTALLED INSIDE WALK-IN/PREP ROOM. (FREEZERS ONLY) SURFACE MOUNTED EMC-DMA 120V COMBINATION DOOR SWITCH\STROBE LIGHT AND HORN PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER AND INSTALLED BY EC. WALK-IN FROM HORN/STROBE TO REFRIGERATION CONTROL PANEL. SEE SHEET RC101. RIC TO PROVIDE AND INSTALL PARKER PARAFLEX SERIES FRPE 1/4" SENSING TUBING FROM RLDS UNIT, THROUGH CONDUIT PRE INSTALLED IN WALL OF THE WALK-IN OR PREP ROOM. FILTER PROVIDED WITH RLDS UNIT AND SHALL BE LOCATED IN PRE INSTALLED 4"X4" BOX. PROVIDE SEALANT PIPING GOOSENECK REFRIG INTAKE LINE FILTER PROVIDED WITH RLDS UNIT. RIC TO PROVIDE AND INSTALL PARKER PARAFLEX SERIES FRPE 1/4" SENSING TUBING FROM RLDS UNIT UP THROUGH REFRIGERATION PIPING GOOSENECK FOR RLDS INTAKE AND EXHAUST. SEE NOTE 7 ON RC101. 12/08/2021 02/07/22