HomeMy WebLinkAboutM102_Mechanical Notes Symbols and SchedulesSHEET NO.
This drawing was prepared for use on a
specific site contemporaneously with its issue
date and it is not suitable for use on a
different project site or at a later time. Use of
this drawing for reference or example on
another project requires the services of
properly licensed architects and engineers.
Reproduction of this drawing for reuse on
another project is not authorized and may be
contrary to the law.
BRR Original printed on recycled paper
COPYRIGHT NOTICE
PROJECT NO.
SHEET TITLE
ISSUES & REVISIONS
DRAWN BY:
PROFESSIONAL SEAL
PROJECT MANAGER:
DOCUMENT DATE:
CHECKED BY:
PROJECT NAME
PROJECT ADDRESS
1 2 3 4 5 ABCDEABCDE12 3 4 5
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
ARCHITECT OF RECORD:
62930563
12/07/2021
THE FRESH
MARKET
The Centre Retail Center
NO. DATE DESCRIPTION
An Erdman Anthony Company
552 Fort Evans RD STE 200
Leesburg, VA 20176
703.777.5988
Leesburg@erdmananthony.com
116th St. and Rangeline Rd.
Carmel, Indiana
CONTACT JOSEPH MILLER (804) 678-5135
WITH CARRIER FOR PRICING INFORMATION
FOR CAPTIVE AIRE FANS, CONTACT EVAN ZIPPERER
(336) 402-3752 FOR PRICING INFORMATION
PROVIDED AND
INSTALLED BY G.C.
PROVIDED AND INSTALLED
BY GENERAL CONTRACTOR
PROVIDED AND
INSTALLED BY G.C.
System Mfr Type Tons CLG MBH HTG MBH SEER Refrig Accessories Serves
1 Mitsubishi Heat Pump, Variable Capacity 1 2.8-12.0 3.0-21.0 23.0 R-410A 1,2 FE Office
INDOOR UNIT
ID Model Dimensions Wt(lbs) CFM Qty Configuration
FC-1 MSZ-FE12NA 32" x 11" x 12"h 27 162-410 1 High Wall
OUTDOOR UNIT
ID Model Dimensions Wt(lbs) Volt/Ph MCA MOCP kW CLG kW HTG
DS-1 MUZ-FE12NA 12"x35"x22"h 119 208/1 12.0 A 15 A 0.9 1.0
Notes (all units UON)
1 Install outdoor unit level on rails and platform.
2 Provide and install refrigerant line sets sized per manufacturer's installation instructions. Exterior insulation on refrigerant
lines shall be covered with UV resistant PVC jackets.
3 Indoor unit wired from outdoor unit by EC.
Accessories
1 Provide and install the mfr's programmable controller, MHK1.
2 Condensate overflow switch to shut down unit in the event of primary drain pan overflow.
Motor(s) Approx
ID Mfr Model Type Hp CFM Volt/Ph kW Dimensions Mgt Height Wt(lbs) Serves Notes
AD-1 Berner IDC12-3096AA Unheated (3) 1/2 4443 120/1 1.50 102"x18"x15"h 10'-0" AFF 240 Loading Dock 1,2,3,4
AD-2 Berner SLC07-1048AA Unheated (1) 1/5 1360 120/1 0.32 47" x 9" x 9"h 8'-0" AFF 42 Delivery Door 1,2,5
AD-3 Berner SLC07-1072AA Unheated (1) 1/5 2031 120/1 0.32 71" x 9" x 9"h 8'-0" AFF 56 Delivery Roll up Door 1,2,5
Notes
1 Install on wall above door. Coordinate exact mounting method and mounting height with door type prior to ordering equipment.
Mounting height listed above is nozzle height above floor.
2 Unit shall be capable of being fastened to wall at ends only, without intermediate support.
3 Provide with factory mounted single phase motor control panel, disconnect, and 24V controls.
4 Control via plunger type door switch for each door.
5 Provide and install deluxe control package.
Nom Tot Clg Sens Clg ARI Heating Heating Heating Supply
ID Mfr Model Tons MBH MBH (S)EER MBH-in Eff Stages CFM ESP OA cfm Wt(lbs)Dimensions
RTU-4 Carrier 48GCSM04 3 34.2 23.7 16.1 67 81% 2 1050 0.50" 0 775 75" x 47" x 34"h
RTU-5 Carrier 48GCSN04 3 35.1 25.6 16.1 67 81% 2 1200 0.75" 0 775 75" x 47" x 34"h
RTU-6 Carrier 48GCRM06 5 63.0 48.3 16.1 110 80% 2 2000 0.75" 200 850 75" x 47" x 42"h
ID Volt/Ph Fan Motor Drive kW MCA MOP Refrig Accessories Serves
RTU-4 460/3 0.71 Hp Direct 2.9 10 A 15 A R-410A 2,4,5,6 Bakery
RTU-5 460/3 0.71 Hp Direct 2.9 10 A 15 A R-410A 2,3,4,5,6 Kitchen
RTU-6 460/3 1.44 Hp Direct 5.0 13 A 15 A R-410A 1,2,4,5,6 Vestibule
Notes (all units)
1 Install level on Mfr's insulated 14"h roof curb. Verify roof slope in field.
2 Provide and install pleated disposable MERV-8 filters, change filters prior to turnover to TFM.
3 All outside air dampers shall fully close in unoccupied mode.
4 Units come with temporary thermostatic control for initial startup and operation. MC shall remove
Connect to CPC Einstein under the direction of the refrigeration controls contractor.
5 Provide 2nd through 5th year complete unit parts only, extended warranty.
Accessories
1 Provide with manufacturer's OA hood and 2-position motorized damper
2 Phase loss protection
3 Hot gas reheat dehumidificaiton system and space humidity sensor
4 Drain pan overflow switch
5 Stainless steel heat exchanger.
6 Hinged access panels
ID Type Mfr Model Description Overall Neck CFM NC max Mounting Material DR TR FD Notes
CD-A S Krueger 5RM2 Round Cone 22.5" dia 10" 200-350 25 Exposed Duct Aluminum YES NO NO 1
CD-B S Krueger 5SHPCR Louvered, Removable Core 24 x 24 10" 250-395 25 T-bar lay-in Aluminum YES YES NO 2
CD-C S Krueger 5SHPCR Louvered, Removable Core 24 x 24 6" 0-125 25 T-bar lay-in Aluminum YES YES NO 2
CD-D S Krueger 5SHPCR Louvered, Removable Core 24 x 24 8" 125-245 25 T-bar lay-in Aluminum YES YES NO 2
CD-E S Krueger 5SHPCR Louvered, Removable Core 12x12 6" 0-150 25 T-bar lay-in Aluminum YES YES NO 2
CD-F S Krueger 5SHPCR Louvered, Removable Core 24x24 12" 400-500 25 T-bar lay-in Aluminum YES YES NO 2
CD-G S Krueger 5RM2 Round Cone 31.5" dia 14" 500 25 Exposed Duct Aluminum YES NO NO 1
CG-A E Krueger 56490 Perforated Face 24 x 24 6" 0-100 20 T-bar lay-in Aluminum YES YES NO
CG-B R Krueger 56490 Perforated Face 24 x 24 8" 100-200 20 T-bar lay-in Aluminum YES YES NO
CG-C R Krueger 56490 Perforated Face 24 x 24 18x18 1000-1200 20 T-bar lay-in Aluminum YES NO NO
CG-D R Krueger 56490 Perforated Face 24 x 24 16x16 900 20 T-bar lay-in Aluminum YES NO NO
CG-E R Krueger 56490 Perforated Face 24 x 24 10" 250-400 20 T-bar lay-in Aluminum YES YES NO
SDR-A S Krueger DPL Drum Louver 14 x 8 12 x 6 200-345 25 Exposed Duct Aluminum YES NO NO 2
SDR-B S Krueger DPL Drum Louver 20 x 8 18 x 6 350-500 25 Exposed Duct Aluminum YES NO NO 2
HSR-A S Krueger 5885 Louvered, Double Deflection, 1/2" spacing 14x8 12x6 0-225 25 Exposed Duct Aluminum YES NO NO
HSR-B S Krueger 5885 Louvered, Double Deflection, 1/2" spacing 20x8 18x6 230-400 25 Exposed Duct Aluminum YES NO NO
HSG-A R Krueger S585 Louvered, 1/2" spacing, 0 deg deflec. 20x12 28x10 575 20 Exposed Duct Aluminum NO NO NO
HSG-B R Krueger S585 Louvered, 1/2" spacing, 0 deg deflec. 32X20 30x18 1720-1800 20 Exposed Duct Aluminum NO NO NO 1
HSG-C R Krueger S585 Louvered, 1/2" spacing, 0 deg deflec. 26x14 24x12 1000 20 Exposed Duct Aluminum NO NO NO 1
LG-A S Krueger 1900 Linear Slot Diffuser with Adj. Defec. 72" Long (3) 1" slot 360 25 T-bar lay-in Aluminum NO NO NO 3,4
LG-B S Krueger 1900 Linear Slot Diffuser with Adj. Defec. 48" Long (2) 1" slot 0-240 25 Exposed Duct Aluminum NO NO NO 3
Abbreviations Notes
DR - Opposed blade volume damper 1 Prime coat, paint in field. Coordinate color with Architect and GC.
TR - Square to round neck transition.2 Adjust throw pattern in field so that registers do not blow into refrigerated cases,
FD - Fire damper assembly with radiation blanket exhaust hoods or cause hanging signs or decorative fixtures to sway.
S - Supply 3 Directional Vanes initially set straight down.
R - Return 4 Provide and install with mfr's insulated plenum boot.
E - Exhaust
ETR/NEW Unit Serves Outside Return Supply Exhaust Pressure Notes
ETR RTU-1 Supermarket Sales 4400 8600 13000 4400
ETR RTU-2 Back Areas 100 1100 1200 100
ETR RTU-3 Back Areas 200 2200 2400 200
NEW RTU-4 Bakery 0 1050 1050 0
NEW RTU-5 Kitchen 0 1200 1200 0
NEW RTU-6 Vestibule 200 1800 2000 200
NEW EF-1 Hood 2100 -2100
NEW EF-2 Dishwasher 1150 -1150
NEW EF-3 Bakery Oven 900 -900
NEW EF-4 Utility Room 150 -150
NEW EF-5 Employee Restrooms 150 -150
NEW EF-6 Customer Restrooms 75 -75
NEW EF-7 Customer Restrooms 75 -75
ETR EF-8 Motor Room Purge 9000 0 1
ETR EF-9 Motor Room Ventilation 450 0 1
NEW MUA-1 Hoods 1 & 2 1100 1100
TOTAL 6000 14050 1400
Notes
1 Makeup air via intake louver
Fan Roof
ID Mfr Type Model CFM ESP Drive RPM Sones Motor Volt/Ph Dimensions Opening Wt(lbs) Serves Notes
EF-1 Captive Aire Roof Mounted NCA18HPFA 2100 1.750" Belt 1223 14.7 2 Hp 460/3 38" dia x 34"h 26.0" sq. 241 Hood 1 1,3,7,9,10,11
EF-2 Captive Aire Roof Mounted NCA10FA 1150 0.60" Belt 1235 13.9 1/2 Hp 115/1 31" dia x 28"h 19.0" sq. 136 Dishwasher 1,2,3,5,10,12,13
EF-3 Captive Aire Roof Mounted NCA14HPFA 900 0.80" Belt 1337 8.2 1/2 Hp 115/1 30" dia x 27"h 19" sq. 136 Bakery 1,3,5,6,10
EF-4 Captive Aire Roof Mounted DR10HFA 150 0.30" Direct 1181 3.3 1/16 Hp 115/1 21" dia x 15"h 13" sq 76 Utility Room 1,2,3,4,5,10
EF-5 Captive Aire Roof Mounted DR10HFA 150 0.30" Direct 1181 3.3 1/16 Hp 115/1 21" dia x 15"h 13" sq 76 Employee Restroom 1,2,3,4,5,10
EF-6 Captive Aire Ceiling Mounted CFA 150CA 75 0.30" Direct 484 N/A 0.134 Hp 115/1 12.25" x 12"h -- 24 Customer Restroom 2,4,10,14,17
EF-7 Captive Aire Ceiling Mounted CFA 150CA 75 0.30" Direct 484 N/A 0.134 Hp 115/1 12.25" x 12"h -- 24 Customer Restroom 2,4,10,14,17
MUA-1 Captive Aire Roof mounted A1-D.500-G10-MPU 1100 0.60" Direct 999 15.9 0.75 Hp 460/3 179" x 39.5" x 63.5"h 14" x 11.5" 1104 Hood 1 7,10,15,16,18
Notes
1 Install fan level on 14"h insulated roof curb. Verify roof slope in field.
2 With factory installed and wired speed controller.
3 With factory installed and wired disconnect switch.
4 Control via EMS. Fan shall run continuously during occupied hours and shall de-energize in unoccupied hours.
5 Provide and install gravity backdraft damper at curb.
6 Interlock with bakery oven operation.
7 Control via hood EMS control panel.
8 Provide and install burglar bars at roof opening.
9 Fan shall be controlled via heat sensor in accordance with Mechanical Code Section 507.2.1.1.
10 Refer to manufacturer's hood/fan drawings for details and additional information. Provide starters and relays and wire as recommended by mfr.
11 Fan shall be UL 762 listed.
12 Interlock with dishwasher operation.
13 Backdraft damper for dishwasher shall be stainless steel.
14 Suspend fan from structure with vibration isolators. Provided with integral backdraft damper.
15 Direct-fired natural gas makeup air unit, 86 MBH-in.
16 Interlock operation with EF-1.
17 With plug type disconnect.
18 With motorized backdraft damper.
MECHANICAL
SCHEDULES
M102
ID Quan Type Mfr Model kW Volt/Ph Amps Mounting Dimensions Controls Set point Serves Notes
EUH-1 1 Unit Heater Berko HUHAA327 3 277/1 11 Ceiling Bracket 14"x 9"x 16"h Built in 45 F Motor Room 1
Notes
1 With mounting bracket.
12/08/2021
Digitally signed by Justin Litz
02/07/22