Loading...
HomeMy WebLinkAboutplan_design_release04292005_approvalELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:January 19, 2022 Project number Release date 427494 01/19/22 Construction type Occupancy classification Scope of release SPK, II-B M, S-1, REM Type of release Project name Street address City County ARCH ELEC FA HOOD MECH PLUM STR Standard The Fresh Market - Carmel IN 1392 S Rangeline Rd CARMEL HAMILTON To: Owner / Architect / Engineer BRR Architecture Trevor T Holcomb AR11800234 8131 S Metcalf Ave. Suite 300 Overland Park KS 66204 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: ACDS 4G0412AE 14B1600 14W1104A 4G0603AF 14B0907 14W09077 14M11081 14M0920 14M050709 This project has been reviewed under the 2014 Indiana Building Code, 2014 Indiana Fire Code, 2009 Indiana Electrical Code, 2012 Indiana Plumbing Code, 2014 Indiana Mechanical Code, 2014 Indiana Fuel Gas Code, 2010 Indiana Accessibility Chapter 11 (ICC A117.1 2009), and the 2010 Indiana Energy Conservation Code (ASHRAE 90.1 2007) The proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. Buildings, or portions thereof, shall be designed and constructed to sustain all dead, live, and environmental loads in accordance with Chapter 16, IBC (675 IAC 13-2.6). Required means of egress shall be maintained during construction and demolition, remodeling or alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5). Detailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6- 3(a), 675 IAC 12-6- 7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in accordance with Section 907, IBC (675 IAC 13-2.6). Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system shall be made. All functions of the system or alteration shall be tested in accordance with Section 907.7, IFC (675 IAC 22-2.5). Refrigeration Systems shall be tested in accordance with section 1108.1 IMC (675 IAC 18-1.6) Suspended-type unit heaters shall be installed and supported in accordance with Section 920, IMC (675 IAC 18-1.6). The complete installation of the kitchen exhaust hood and hood suppression system shall be in accordance with Sections 507 and 509, IMC (675 IAC 18-1.6). Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 2142909095, ty.holcomb@brrarch.com ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 14M0507161 9E250104B 14FG041114 4G0623A AREL Type I kitchen hoods shall be tested prior to occupancy as set forth in Section 507.16, IMC (675 IAC 18-1.6). All other metal piping shall be bonded in accordance with Section 250.104 [B] IEC (675 IAC 17-1.8) (Gas Piping) Gas fired appliances on wheels in Commercial Kitchens shall be installed as set forth in section 411.1.4 IFGC (675 IAC 25-3) (Quick Disconnects and Tethered) Storage of some commodities at a height of six feet or more may be high-piled storage as defined in 675 IAC 22-2.5, Section 202. Improper use of this structure for high-piled storage will subject the project design release to revocation in accordance with 675 IAC 12-6-23. Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. This order is effective upon service. If you would like to request informal review of this order, please complete the informal review form located at https://www.in.gov/dhs/4149.htm. Following receipt of this form, the Department may modify or reverse the order, however, a request for an informal review does not extend the deadline for filing a petition for review with the Fire Prevention and Building Safety Commission (Commission). Additionally, if you have any questions regarding this order, you may contact that Department at (317) 232-2222. If you desire a formal administrative review of this order by the Commission, you must comply with the requirements of Indiana Code § 4-21.5-3-7 and file a written petition for review within 15 days of the date this order was served, however, this period is extended to 18 days if service is made by mail. Your petition for review must state facts demonstrating that you are: (1) a person to whom the order is specifically directed; (2) aggrieved or adversely affected by the order; or (3) entitled to review under any law. You may submit your petition by the following methods: U.S. MAIL OR PERSONAL SERVICE ONLINE Fire Prevention and Building Safety Commission By completing the form at c/o Legal Counsel https://www.in.gov/dhs/4148.htm 302 W. Washington Street, Rm. E208 Indianapolis, IN 46204 For additional information about the administrative review process and applicable templates that may be used for filings, visit the following link https://www.in.gov/dhs/appeals.htm. Code review official Address (name,title of local official,street,city,state and ZIP code DESHAWN JORMAN JIM BLANCHARD ONE CIVIC SQUARECARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Indiana State Building Commissioner DJorman@dhs.IN.gov