HomeMy WebLinkAboutRangeline (Carmel) IN - ElectricalTRADITIONAL LIGHTING PACKAGE TYPE SYMBOL DESCRIPTION MANUFACTURER AND MODEL # MOUNTING VOLTAGE LAMPS/ FIXTURE COLOR TEMP BALLASTS/ FIXTURE INPUT WATTS/ FIXTURE NOTES A 2'x2' LENSED GRID HIGH FLAT LENSE US LED GTR3-22-35-80-F-A-H-N CEILING RECESSED 120-277V LED - 5062 LUMENS 3500K 1 50.5 W 56 VA - AE 2'x2' LENSED GRID HIGH FLAT LENSE EM US LED GTR3-22-35-80-F-A-H-B CEILING RECESSED 120-277V LED - 5062 LUMENS 3500K 1 50.5 W 56 VA 1 AG 2'x2' LENSED GRID TROFFER. US LED GTR3-22-35-80-F-A-S-N CEILING RECESSED 120-277V LED - 3564 LUMENS 3500K 1 32.8 W 36 VA - AGE 2'x2' LENSED GRID3 HIGH FLAT LENSE EM US LED GTR3-22-35-80-F-A-S-B CEILING RECESSED 120-277V LED - 3564 LUMENS 3500K 1 32.8 W 36 VA 1 DL DOCK LIGHT WITH MOUNTING ARM, ON/OFF SWITCH, AND WET LOCATION LABEL.US LED LEDDL16565Y01 WITH 90" ARM WALL BRACKET AT 5'-0" AFF 120-277V LED - 870 LUMENS 6500K 1 17 W 19 VA - DP2 LED DECORATIVE PENDANT US LED FM1-WH-WH-35-105-180 CORD MOUNT 1O'-0" AFF TO BOTTOM UON 120V LED - 3330 LUMENS 3500K 1 36 W 40 VA 4 H2 4' VAPORTIGHT LED. US LED USVT-24-35 SURFACE MOUNT 120V LED - 4014 LUMENS 3500K 2 STAR-TB LED TUBE 1 31.4 W 44 VA - H2 4' DG1 LINEAR HIGH LED W/DIMMING.US LED DG1-2-1-35-1-2-PUE- UNV2-4100-2 MOUNT 9' -6" AFF. USING Y-DROP STYLE TOGGLE KIT. UON 120-277V LED - 10142 LUMENS 3500K 1 97 W 108 VA - H1 8' VAPORTIGHT LED. US LED USVT-44-35 SURFACE MOUNT 120V LED - 8028 LUMENS 3500K 4 STAR-TB LED TUBE 1 62.8 W 88 VA - LR6 LED DOWNLIGHT. 6 IN. TRIM. US LED LTR2-1-UNV-35-15-6R-C-WH CEILING RECESSED 120V LED - 877 LUMENS 3000K 1 15.5 W 16 VA - M LED PENDANT. US LED P32 PENDANT MOUNT 14' -0" AFF TO BOTTOM UON 120-277V LED - 1328 LUMENS 3500K 1 15 W 17 VA - P 8 WATT LED GRAVITY-FIT PENDANT. US LED CRS89630K-106W-AB-10' PENDANT MOUNT 6'-0" AFF TO BOTTOM UON 120-277V LED - 750 LUMENS 3500K 1 8.1 W - PS 3 LAMP FISHER ISLAND LED PENDANT. US LED FC00065870 PENDANT MOUNT 8'-0" AFF TO BOTTOM UON 120-277V LED - 2250 LUMENS 3000K 3 27 W 30 VA - W LED EXTERIOR EGRESS WALL SCONCE DUAL LITE PG-W EM WALL SCONCE 9'-0" AFF TO BOTTOM UON 120-277V LED - 405 LUMENS 6350K 1 2.78 W 3 VA 6 W1 LED EXTERIOR WALL SCONCE US LED DSCO1-3-UNVL-50-96-BZ WALL SCONCE 15'-0" AFF TO BOTTOM UON 120-277V LED - 960 LUMENS 5000K 1 40 W 44VA 5 B12 1-CIRCUIT TRACK (12'-0" NOMINAL LENGTH). US LED LT-12-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - -2 B8 1-CIRCUIT TRACK (8'-0" NOMINAL LENGTH). US LED LT-8-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 B6 1-CIRCUIT TRACK (6'-0" NOMINAL LENGTH). US LED LT-6-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 B4 1-CIRCUIT TRACK ( 4'-0" NOMINAL LENGTH). US LED LT-4-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 B2 1-CIRCUIT TRACK (2'-0" NOMINAL LENGTH). US LED LT-2-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V - - - - 2 BC 1-CIRCUIT TRACK (FIELD CUT TO LENGTH).US LED LT-2-P CABLE MOUNT 12'-0" AFF TO BOTTOM OF TRACK UON 120V ----2 PAR38 LED TRACK HEAD AND GIMBAL RING FOR PAR 38. SALES FLOOR.US LED CTL 2838N-P TRACK MOUNT 120V LED - 1050 LUMENS 3000K 16PAR38G3 DIM/830NF25 1 16 18.5 VA - LT LED TRACK HEAD AND GIMBAL RING FOR PAR 30. SALES FLOOR.US LED CTL 2830N-P TRACK MOUNT 120V LED - 850 LUMENS 3000K 14PAR30G3 DIM/830NF25 1 14 12.5 VA - X LED EXIT SIGN.US LED CXL3RW UNIVERSAL 120-277V LED 1 3.7 4 VA 3 STRAIGHT TRACK JOINER. US LED TRACK JOINER. US LED TRACK END FEED. US LED NOTES: 1. CONNECT BRANCH CIRCUIT TO EMERGENCY BALLAST AHEAD OF CONTACTORS AND LOCAL SWITCHING. 2. ATTACH SUPPORT CABLE TO TRACK PER TFM'S INSTRUCTIONS. 3. CONNECT TO BRANCH CIRCUIT AHEAD OF CONTACTORS AND LOCAL SWITCHING. 4. DP2 FIXTURES LOCATED OVER THE CHECKSTANDS SHALL BE PROVIDED WITH (2) ADDITIONAL MANUFACTURER'S LENSES PER FIXTURE, PART #09-000130. 5. CONFIRM LAMP COLOR PRIOR TO ORDERING. 6. CONFIRM FIXTURE HOUSING COLOR PRIOR TO ORDERING. H2 H A DP2 M LR6 H1 PAR38 LT X P AE AG AGE B8 B12 B4 B6 BC B2 P2 W1 W RTU LFMC TFM UON WP C. WG AFF G. ROOF TOP UNIT UNLESS OTHERWISE NOTED LIQUIDTIGHT FLEXIBLE METAL CONDUIT THE FRESH MARKET ABOVE FINISHED FLOOR WEATHERPROOF(WHILE-IN-USE) GROUND WEATHERPROOF(WHILE-IN-USE)/GFCI TYPE CONDUIT IG ISOLATED GROUND GF GROUND FAULT CIRCUIT INTERRUPTER (P)PARTIAL CIRCUIT T1 DATA OUTLET WITH PATCH PANEL PORT # INDICATED. DSL OUTLET. PROVIDE CABLING TO DSL EQUIPMENT ON TELECOM BACKBOARD.DSL D1 TELEPHONE OUTLET WITH OUTLET # INDICATED. CPC OUTLET.CPC EMPLOYEE TIME CLOCK DATA OUTLET. PROVIDE CABLING PER TFM SPECIFICATIONS.TC DOOR SENSOR.DS NOTES: PROVIDE OUTLET BOX AND PROVIDE CONDUIT AS INDICATED ON DRAWINGS E109 AND EU102. ALL FIXTURES, LAMPS, TRACK, TRACK FITTINGS AND SUPPORT CABLE SHALL BE FURNISHED BY THE FRESH MARKET AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED. QUANTITIES SHALL BE VERIFIED BY TFM'S SUPPLIER. ETR,(E) EXISTING TO REMAIN TYPICAL LIGHTING FIXTURES - LETTER INDICATES TYPE. EMERGENCY LIGHTING UNIT -SEE LIGHTING FIXTURE SCHEDULE. REMOTE EMERGENCY LAMP HEADS - SEE LIGHTING FIXTURE SCHEDULE. DUPLEX RECEPTACLE. GFCI DUPLEX RECEPTACLE. GF GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF- WHILE-IN USE COVER.WG SPECIAL PURPOSE RECEPTACLE. ISOLATED GROUND SIMPLEX RECEPTACLE WITH ORANGE FACE. ISOLATED GROUND DUPLEX RECEPTACLE WITH ORANGE FACE. IG IG FLOOR BOX WITH DUPLEX GFCI RECEPTACLE AND ROUND BRASS COVER WITH FLIP LIDS. LEGRAND 881-895TGFI. FUSIBLE DISCONNECT, AMP RATING/# POLES/FUSE RATING INDICATED. IF NO FUSE RATING IS INDICATED, FUSE PER EQUIPMENT MANUFACTURER'S RECOMMENDED MOCP. PRVOIDE TYPE NEMA 3R FOR OUTDOOR LOCATIONS. ELECTRICAL CONNECTION TO EQUIPMENT. COORDINATE LOCATION AND CONNECTION DETAILS WITH EQUIPMENT PROVIDER. JUNCTION BOX. SINGLE POLE SWITCH. THREE-WAY SWITCH. 2-POLE MOTOR-RATED TOGGLE DISCONNECT WITH PADLOCKABLE HANDLE. 20A SWITCH WITH RED PILOT LIGHT (PILOT LIGHT ON WHEN LIGHTS ARE ON). DOOR LIMIT SWITCH. EXIT SIGN - SEE LIGHTING FIXTURE SCHEDULE. FILLED SECTION INDICATES FACE, ARROW INDICATES DIRECTION FLUSH MOUNTED PANEL BOARD. SURFACE MOUNTED PANEL BOARD. MOTION SENSOR - SENSOR SWITCH #CMR-9-LT-P, OR EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE PROPER OPERATION OF THE DEVICE. MOTION SENSOR - SENSOR SWITCH #CMR-PDT-2P, OR EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE PROPER OPERATION OF THE DEVICE. WEATHERPROOF PUSH BUTTON FOR DOOR BELL - EDWARDS #1785 OR EQUAL. DOOR BELL AND TRANSFORMER. EDWARDS #340-4GS BELL (24v, 4") AND #599 TRANSFORMER (120v PRI. - 24v SEC.) OR EQUAL. BRANCH CIRCUIT CONCEALED, UNLESS OTHERWISE NOTED. HOMERUN CIRCUIT - PANEL AND CIRCUIT NUMBER INDICATED. PIR OCCUPANCY SENSING WALL SWITCH - SENSOR SWITCH #WSD NGX OR EQUAL. CONTRACTOR SHALL ADJUST THE DEFAULT SETTINGS AFTER INSTALLATION TO PROVIDE PROPER OPERATION OF THE DEVICE. SWITCH TO BE SET FOR MANUAL 'ON' AND AUTO 'OFF' FLOOR BOX WITH SPECIAL RECEPTACLE TO MATCH EQUIPMENT REQUIREMENTS AND ROUND BRASS COVER. LEGRAND 881-896TCK. SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana LIGHTING SCHEDULE & SYMBOL LEGEND E-101 BSD DSP LC LIGHTING CONTACTOR COIL USB DUPLEX RECEPTACLE WITH USB CHARGER. E101 ELECTRICAL NOTES, SYMBOLS, AND SCHEDULES E102 LIGHTING PLAN E103 EMERGENCY LIGHTING AND EXIT SIGN PLAN E104 POWER PLAN E105 ENLARGED POWER PLANS E106 ROOF POWER PLAN E107 CASE POWER AND LIGHTING PLAN E108 LOW VOLTAGE DEVICES AND WIRING PLAN E109 LOW VOLTAGE RISER AND DETAILS E110 ELECTRICAL RISER E111 ELECTRICAL SCHEDULES E112 ELECTRICAL SCHEDULES E113 ELECTRICAL DETAILS E114 ELECTRICAL DETAILS E116 FIRE ALARM PLANS 1. PRIOR TO REFRIGERATION STARTUP PROVIDE SEAL FITTINGS AT ELECTRICAL PENETRATIONS INTO FREEZERS, COOLERS AND PREP AREAS TO PREVENT MOISTURE MIGRATION. CAULK AROUND CONDUIT PENETRATIONS THROUGH WALL AND CEILINGS. CAULK WIRES INSIDE CONDUIT ENTERING COOLER/FREEZER. SEE DETAIL 10/E113. 2. DO NOT ATTACH SUPPORTS TO THE ROOF DECK. INSTEAD, ATTACH SUPPORTS TO THE ROOF STRUCTURAL FRAMING. 3. UNLESS OTHERWISE NOTED, TYPE MC CABLE SHALL NOT BE PERMITTED EXCEPT FOR WHIPS OF LESS THAN 6 FEET DOWN FROM JUNCTION BOXES TO LIGHT FIXTURES MOUNTED IN DROPPED CEILINGS. 4. CONDUIT FOR LIGHTING AND EVAPORATOR SHALL RUN ALONG TOP OF COOLER BOXES. CONDUIT SHALL NOT RUN INSIDE COOLER BOXES. CONDUIT IS ALLOWED TO RUN INSIDE FREEZER BOXES (TO LIMIT BOX PENETRATIONS). 5. LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL BE USED UNDER REFRIGERATED CASES. 6. LIGHT FIXTURES IN FOOD PREP AREAS ARE ALL LED AND HAVE SHATTERPROOF COVERS. 7. ALL PENETRATIONS SHALL BE PROPERLY SEALED. 8. ALL SWITCHES & OUTLETS TO BE WHITE. COVERS TO BE STAINLESS AT FOOD PREP AREAS & “LIGHT ALMOND” EVERYWHERE ELSE. BOTH LEGRAND AND PASS & SEYMOUR MAKE THIS COLOR. 9. LIGHT FIXTURES ARE PURCHASED BY THE FRESH MARKET. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, INVENTORYING, SECURING AND INSTALLING THE FIXTURES 10. IN BOX COOLERS/FREEZERS, COORDINATE LIGHTING FIXTURES WITH BLOWER COIL UNITS. 11. LEVEL LIGHTING TRACKS AFTER INSTALLING, POSITIONING AND AIMING LAMP HEAD. 12. COORDINATE LIGHTING FIXTURE LOCATIONS WITH REFLECTED CEILING PLAN ON ARCHITECTURAL DRAWINGS. 13. DO NOT ATTACH SUPPORTS TO THE ROOF DECK. INSTEAD, ATTACH SUPPORTS TO THE ROOF STRUCTURAL FRAMING. 14. TYPE SO CORD (BLACK IF THERE IS AN EXPOSED OR GREEN CEILING AND WHITE IF THERE IS A WHITE CEILING), OR MC CABLE IF TYPE SO CORD IS PROHIBITED, SHALL BE USED FOR DROPS DOWN TO LIGHTING TRACK. 12/08/2021 02/07/22 KEY NOTES 1 CONNECT TO SWITCHES SUPPLIED WITH BOX COOLER/FREEZER. 2 MOUNT ON COOLER CEILING NEAR THE DOOR. 3 CIRCUIT CONTAINS EMERGENCY LIGHTING. SEE SHEET E103. CIRCUIT BATTERY PACK AHEAD OF SWITCHING 4 TYPE LR6 FIXTURES IN DELI CANOPY, BAKERY/MEAT/SEAFOOD CANOPY, AND FLORAL CANOPY ARE FACTORY WIRED TO JUNCTION BOX CONNECT BRANCH CIRCUIT TO JUNCTION BOX. 5 NOT USED. 6 SEE DRAWING E104 FOR DOCK LIGHT RECEPTACLE CIRCUIT. 7 MOUNT DOCK LIGHT AT 72” AFF. 8 LIGHT FIXTURE USED FOR NORMAL AND EMERGENCY EGRESS LIGHTING. 9 B.E.OFFICE SECURITY NIGHT LIGHT. 10 MOUNT JUNCTION BOX FOR BUILDING SIGN ON THE INTERIOR FACEOF THE EXTERIOR WALL. COORDINATE LOCATION WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.. 11 LIGHTING INVERTER TO PROVIDE 90 MINUTE BACKUP POWER TO INDICATED LIGHT FIXTURES. SEE "INV" SCHEDULE ON SHEET E112 EMERGENCY LIGHTING CIRCUIT CONTROL CONTACTOR WITH ENCLOSURE TO BE MOUNTED ABOVE THE INVERTER. SEE DETAILS5/E113 AND 9/E113 FOR ADDITIONAL INFORMATION. 12 EXISTING TO REMAIN EXTERIOR LIGHTING POWERED FROM LANDLORD HOUSE SERVICE. 13 EXISTING TO REMAIN EXTERIOR LIGHTING ASSUMED TO BE POWERED FROM CIRCUITS LA-16 & LA-18, VERIFY CIRCUITS IN FIELD. 1. WALK-IN BOX LIGHTING TO BE COORDINATED WITH OTHER TRADES. 2. REFER TO DRAWING E101 FOR LIGHT FIXTURE SCHEDULE AND LEGEND. 3. EMERGENCY INPUT OF EMERGENCY FIXTURES TO BE WIRED AHEAD OF ALL LOCAL CONTROLS. 4. CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF TRIP LIGHTING INSTALLED DURING CONSTRUCTION. GENERAL NOTES 4 54.4 Z Y INV-2(P) LB-75 INV-2(P) R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)DELLFRIOEFE-5052HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HONHC1872 ATLANTIC FOODBARSHHDD5136-TFMHONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D 48x18x60 L48x18x60 L48x18x60 L24x18x60 L WRAPPING BOARD UP UP MEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R.MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B B C C D D E E F F G G A A Z Y MEAT & SEAFOOD COOLER 303 C4 10'-0" MEAT & SEAFOOD PREP 304 C5 10'-0" OFFICE 400 C2 9'-6" WOMEN'S R.R. 401 C6 8'-0" MEN'S R.R. 402 C6 8'-0"INSTACART 404 C2 9'-6" CLOSET 403 C2 9'-6" ENTRY/EXIT VESTIBULE 100 - ETR FRONT END CHECKOUT AREA 101 C1 OTS FLORAL SALES 114 C1 OTS PRODUCE SALES 113 C1 OTS MEAT SERVICE AISLE 203 C3 9'-6" BAKERY SERVICE AISLE 112 C3 9'-6" DAIRY SALES 111 C1 OTS FROZEN SALES 110 C1 OTS GROCERY SALES 109 C1 OTS BEER AND WINE SALES 107 C1 OTS BULK/COFFEE/CANDY SALES 108 C1 OTS DELI PREP 202 C8 10'-0" RECEIVING 502 ETR ETR BOH CORRIDOOR 504 C1 OTS FLORAL COOLER 316 C4 10'-0" FLORAL PREP 315 C3 9'-6" PRODUCE COOLER 314 C4 10'-0" PRODUCE PREP 313 C5 10'-0" KITCHEN 312 C3 10'-0" COLD COOKED PREP 311 C5 10'-0" COLD COOKED COOLER 310 C4 10'-0" SCULLERY 309 C3 10'-0" FIRE RISER 503 ETR ETR BAKERY PREP 302 C3 9'-6" BAKERY COOLER 301 C4 10'-0" DAIRY COOLER 300 C4 10'-0" BREAK ROOM 405 C2 9'-0" RESTROOM 408 C2 8'-0" RESTROOM 407 C2 8'-0" WELLNESS ROOM 406 C2 9'-0" BULK COOLER 305 C4 10'-0" ICE CREAM FREEZER 306 C4 10'-0" BAKERY DELI GROCERY FREEZER 307 C4 10'-0" MEAT & SEAFOOD FREEZER 308 C5 10'-0" ELECTRICAL ROOM 501 ETR ETR RESTROOM COORIDOR 409 C2 12'-0" P2P2 P2 P2 P2 P2 P2P2 P2 LB-20 LB-2 LB-1 LB-27,29 LB-13 LB-15,17 LB-23 LB-3 LB-5 LB-71 LB-6,8 LB-10 LB-9 L1-24 LB-16 LB-18 LB-4 LB-75 LB-22(P) LB-25(P) LB-12 INV-2(P) INV-2(P) INV-2(P) INV-2(P) INV-2(P)INV-2(P) INV-2(P) INV-2(P)INV-2(P) INV-2(P) INV-2(P) INV-2(P) INV-2(P) INV-2(P) INV-2(P) INV-2(P) INV-4(P) INV-4(P)INV-4(P) INV-4(P) INV-3(P) INV-3(P)INV-3(P) INV-3(P)INV-3(P)INV-3(P) INV-3(P) INV-3(P)INV-3(P)INV-3(P) INV-3(P) INV-3(P) INV-3(P) INV-3(P) INV-3(P)INV-3(P) INV-3(P) INV-3(P) INV-3(P) INV-3(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P) INV-4(P)INV-4(P) INV-4(P) INV-4(P) INV-4(P)INV-4(P) INV-4(P)INV-4(P) INV-4(P) LB-7 INV-4(P) INV-4(P) 17 17 15 17 17 17 15 15 15 15 17 17 15 15 15 17 INV-4(P) INV-4(P) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 88 8 8 8 INV-4(P) INV-4(P) INV-4(P) LB-14 LB-73 INV-2(P)INV-2(P) INV-2(P) INV-2(P) LB-25(P) LB-22(P) INV-2(P) LB-26 INV-2(P) INV-2(P) INV-2(P) LB-11 LB-25(P) SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana LIGHTING PLAN E-102 BSD DSP 12/08/2021 02/07/22 1 FIXTURE POWERED BY THE EMERGENCY LIGHTING INVERTER AND SHOWN HERE FOR REFERENCE. SEE SHEET E102 FOR CIRCUITING. 2 PENDANT MOUNT AT 12'-0" AFF. 3 FIXTURE WITH EMERGENCY BALLAST SHOWN HERE FOR REFERENCE. SEE SHEET E102 FOR CIRCUITING. 4 EMERGENCY LIGHTING CONTACTOR WITH ENCLOSURE MOUNTED ON WALL ABOVE INVERTER. CONTACTOR AND ENCLOSURE PROVIDED BY HILL PHOENIX AND INSTALLED BY ELECTRICAL CONTRACTOR. SEE INVERTER DETAILS 5/E113 AND 9/E113 FOR ADDITIONAL INFORMATION. 5 PENDANT MOUNT AT 9’-6” AFF. 6 MOUNT DIRECTLY ABOVE DOOR. 7 CONTRACTOR SHALL COORDINATE THE LOCATION OF EXIT SIGN WITH THE OTHER DISCIPLINES TO INSURE THAT THE SIGN IS NOT VISUALLY OBSCURED. 8 EXISTING TO REMAIN HID WALLPACK WITH EMERGENCY BALLAST SHOWN HERE FOR REFERENCE. KEY NOTES 1. REFER TO DRAWING E101 FOR LIGHT FIXTURE SCHEDULE AND LEGEND. 2. EMERGENCY INPUT OF EMERGENCY FIXTURES TO BE WIRED AHEAD OF ALL LOCAL CONTROLS. 3. EXTERIOR EGRESS NORMAL AND EMERGENCY LIGHT FIXTURES ARE EXISTING TO REMAIN AND SHOWN FOR REFERENCE ONLY. GENERAL NOTES 4 54.4 Z Y 1.4 1.41 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B B C C D D E E F F G G A A Z Y MEAT & SEAFOOD COOLER 303 C4 10'-0" MEAT & SEAFOOD PREP 304 C5 10'-0" OFFICE 400 C2 9'-6" WOMEN'S R.R. 401 C6 8'-0" MEN'S R.R. 402 C6 8'-0"INSTACART 404 C2 9'-6" CLOSET 403 C2 9'-6" ENTRY/EXIT VESTIBULE 100 - ETR FRONT END CHECKOUT AREA 101 C1 OTS FLORAL SALES 114 C1 OTS PRODUCE SALES 113 C1 OTS MEAT SERVICE AISLE 203 C3 9'-6" BAKERY SERVICE AISLE 112 C3 9'-6" DAIRY SALES 111 C1 OTS FROZEN SALES 110 C1 OTS GROCERY SALES 109 C1 OTS BEER AND WINE SALES 107 C1 OTS BULK/COFFEE/CANDY SALES 108 C1 OTS DELI PREP 202 C8 10'-0" RECEIVING 502 ETR ETR BOH CORRIDOOR 504 C1 OTS FLORAL COOLER 316 C4 10'-0" FLORAL PREP 315 C3 9'-6" PRODUCE COOLER 314 C4 10'-0" PRODUCE PREP 313 C5 10'-0" KITCHEN 312 C3 10'-0" COLD COOKED PREP 311 C5 10'-0" COLD COOKED COOLER 310 C4 10'-0" SCULLERY 309 C3 10'-0" FIRE RISER 503 ETR ETR BAKERY PREP 302 C3 9'-6" BAKERY COOLER 301 C4 10'-0" DAIRY COOLER 300 C4 10'-0" BREAK ROOM 405 C2 9'-0" RESTROOM 408 C2 8'-0" RESTROOM 407 C2 8'-0" WELLNESS ROOM 406 C2 9'-0" BULK COOLER 305 C4 10'-0" ICE CREAM FREEZER 306 C4 10'-0" BAKERY DELI GROCERY FREEZER 307 C4 10'-0" MEAT & SEAFOOD FREEZER 308 C5 10'-0" ELECTRICAL ROOM 501 ETR ETR RESTROOM COORIDOR 409 C2 12'-0" 1.4 1.41 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y B/CDOUBLECOMBI12GC/OSUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTY SALADSORDER F R R H R N H H H H R H 20' CHEESE DISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSSMANNQ3 . 5 - S S - 4 RRHUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC R E F ' G B E R R Y B I NSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12 HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANNIM - 0 5 - E N 4 -R HONHC1872 ATLANTIC FOOD BARSHHDD5136-TFMHILL PHOENIXSSGC-SSC-8 HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D 48x18x60 L48x18x60 L48x18x60 L24x18x60 L WRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR L H U S S M A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R.MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RL HUSSMANN RL 4DR RL HUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC MEAL SOLUTIONS(WALK AROUND)HUSSMANNIM-04-E5-RH U S S MANNIM-04-C6-RHUSSMANNIM - 0 4 - C 6 - RHUSSMANNIM - 0 4 - C 6 - RHUSSMANNIM-0 4 - C 6 -R HUSSMANQ4BV 10' RL HUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCLUDES 4'PRODUCE DRINKS6'RE FR I G ER A T E DWINE W/ WINEHOLDER20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 D K CA S E S 12' DRINKSHILL PHOENIXON5DM-NRG-12HILL PHOENIXON 5DM- N RG -8HILL PHOENIXON5DM-NRG-8HILL PHOE N IX ON5DM-NRG-12PASTASAUCE/SOUPSSHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana EMERGENCY LIGHTING AND EXIT SIGNS PLAN E-103 BSD DSP 12/08/2021 02/07/22 PA-33(P) WG/48" GF/80" PA-23 8 KEY NOTES 1 MOUNT RECEPTACLE TO GONDOLA MILLWORK. 2 FLOOR BOX FOR FUTURE DISPLAY. 3 RECEPTACLE FOR REVERSE OSMOSIS SYSTEM. MOUNT ABOVE EQUIPMENT SHELF. 4 CONTRACTOR SHALL CIRCUIT HOOD LIGHTS TO MANUFACTURER PROVIDED LIGHTING CONTROLS. 5 CONNECTION FOR HAND DRYER, MOUNT AT 45” AFF. COORDINATE LOCATION WITH ARCHITECTURAL DRAWINGS. 6 RECEPTACLE FOR BAGGED ICE FREEZER. 7 PLUG AND CONNECTOR FOR MEAT GRINDER OR MEAT SAW PROVIDE HUBBELL #HBL2423SW CONNECTOR, AND #HBL2421SW PLUG WITH 6’-0” LONG, 12/4 (3#12, #12 G.) SO CORD. HANG FROM CEILING WITH 12/4 SO CORD (FIELD-DETERMINE LENGTH) WITH STRAIN RELIEF GRIPS. 8 RECEPTACLE FOR MEAT AISLE TAKE-A-NUMBER SYSTEM. 9 RECEPTACLE FOR BUG LIGHT. PROVIDE CORD AND PLUG AND CONNECT TO BUG LIGHT. MOUNT BUG LIGHT AT 80” AFF TO BOTTOM UNLESS OTHERWISE NOTED. 10 CONNECT TO EXISTING AUTOMATIC DOOR OPERATOR. 11 RECEPTACLE FOR DEODORIZER. MOUNT RECEPTACLE 6” ABOVE COMPACTOR CHUTE DOOR. 12 ROUTE CONDUIT DOWN ALONG SIDE OF REFRIGERATION PIPING. 13 RECEPTACLE FOR FLOOR MACHINE. 14 CONNECT TO ICE FLAKER. 15 TRASH COMPACTOR CONNECTION. ROUTE POWER CIRCUIT FOR COMPACTOR THRU DISCONNECT SWITCH. MOUNT CONTROLLER AND PROVIDE CONTROL WIRING PER MANUFACTURER’S SPECIFICATIONS. 16 CONNECT TO BALER. 17 CONTRACTOR SHALL PROVIDE A CORD AND PLUG FOR THE EQUIPMENT. 18 AIR DOOR IS FURNISHED WITH MANUFACTURE'S DISCONNECT SWITCH. COORDINATE WITH MECHANICAL CONTRACTOR. 19 RECEPTACLE FOR DOCK LIGHT. 20 POWER AND CONTROL WIRING FROM CONDENSING UNIT ON ROOF, REFER TO E106. 21 RECEPTACLE FOR REFRIGERATION WIFI. MOUNT RECEPTACLE TO BAR JOIST. 22 FLOOR BOX FOR CHECKSTAND MERCHANDISER. 23 FLOOR BOX FOR ROTISSERIE CHICKEN. 24 FLOOR BOX FOR S/C PRODUCE BIN. 25 EMPLOYEE MICROWAVE RECEPTACLE. 26 CONTROL POWER FOR DEFROST PANEL. 27 RECEPTACLE FOR ELECTRIC WATER COOLER. COORDINATE LOCATION WITH PLUMBING CONTRACTOR PRIOR TO ROUGH-IN. 28 CONNECT TO FACTORY JUNCTION BOX FOR POWER TO CASE IG RECEPTACLES. 29 MOUNT RECEPTACLE HORIZONTALLY ABOVE THE COUNTER. 30 CONTROL POWER FOR REFRIGERATION RACK A. 31 POWER CONNECTION FOR RACK B CONTROLS 32 FAN COIL UNIT IS BEING RELOCATED IN THE ROOM, EC SHALL EXTEND EXISTING POWER AND CONTROL WIRING TO NEW LOCATION. 33 CONTROL POWER FOR COMPACTOR. COORDINATE LOCATION OF CONTROLLER WITH TFM REPRESENTATIVE PRIOR TO ROUGH-IN. 34 MOUNT RECEPTACLE HORIZONTALLY ABOVE BACKSPLASH. 35 SEE ELEVATION 1/E114 FOR RECEPTACLE LOCATIONS AND CIRCUITING. 36 CONTRACTOR TO ROUTE CIRCUITS IN BELOW SLAB CONDUIT AND CONNECT TO QUAD RECEPTACLE FURNISHED WITH CABINET. SEE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION. 37 RECEPTACLE FOR BATTERY POWERED WHEEL CHAIR. 38 CONNECTION TO WH RECIRC. PUMP. 39 COORDINATE OUTLET INSTALLATION WITH MILLWORK. 40 CONNECT TO INSTANTANEOUS WATER HEATER. COORDINATE INSTALLATION WITH PC PRIOR TO ROUGH-IN. 41 FLOOR BOX FOR HEN HUT. 42 CONNECTION TO QUAD RECEPTS, TYPICAL. 43 THIS GFCI RECEPTACLE SHALL PROVIDE GROUND FAULT PROTECTION FOR ANY DOWNSTREAM RECEPTACLES. 44 EC SHALL PROVIDE A 2 POLE CONTACTOR ABOVE ACCESSIBLE CEILING IN A NEMA 1 ENCLOSURE WITH 120V COIL FOR CONTROL OF DISHWASHER EXHAUST FAN. RUN CONTROL WIRING FROM COIL CONTACTOR TO DISHWASHER FAN RELAY AND RUN FAN POWER CIRCUIT THROUGH CONTACTOR SO FAN IS ENERGIZED WHEN DISHWASHER IS IN OPERATION. COORDINATE WORK WITH EQUIPMENT MANUFACTURER. REFER TO ROOF POWER PLAN ON E106 FOR FAN LOCATION AND ADDITIONAL INFORMATION. 45 EXISTING TO REMAIN DOK-LOK SYSTEM. VERIFY WORKING CONDITION OF EQUIPMENT AND CIRCUIT AND NOTIFY THE FRESH MARKET PROJECT MANAGER OF ANY PROBLEMS. 46 CLEAR WORKING SPACE FOR ELECTRICAL EQUIPMENT. 47 NO JUNCTION BOXES OR PULL BOXES ARE TO BE INSTALLED ABOVE REFRIGERATION PIPING, SEE REFRIGERATION PIPING PLAN ON SHEET R102. 48 RLDS TO BE MOUNTED SO TOP IS AT 5' AFF. LCP TO BE MOUNTED ABOVE RLDS. 49 EXISTING TO REMAIN DOCK LIFT. VERIFY WORKING CONDITION OF EQUIPMENT AND CIRCUIT AND NOTIFY THE FRESH MARKET PROJECT MANAGER OF ANY PROBLEMS. 50 EXISTING TO REMAIN RECEPTACLE CIRCUIT WIRED TO CIRCUIT R2-34. 51 EXISTING TO REMAIN CONNECTION TO HEATER RH-1. VERIFY EXACT CIRCUIT AND UPDATE PANEL DIRECTORY AS NEEDED. 52 EXISTING TO REMAIN CONNECTIONS TO DE-STRATIFICATION FANS. VERIFY EXACT CIRCUIT AND UPDATE PANEL DIRECTORY AS NEEDED. 4 54.4 Z Y (E) SB CNTRL PANEL (E) LB(1) (E) LB(2) (E) LA (E) H (E) R1 (E) R2 (E) SC (E)T2 IG/84"SC-23 30 31 HSB-2 26 FACP R2-37 LSB-37 PA-15 84" R2-39 48 LB-68 G-1 G-3 49PG-14,16PG-18,20 G-25,27 HSB-4 (E) (E) (E) 46 EQUIPMENT CLEARANCE EQUIPMENT CLEARANCE 47 50 50 50 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y HUSSMANNQ3.5-SS-6RHUSSMANNQ3.5-SS- 4 R R HUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC R E F'G B E RR Y B I NSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12HUSSMANN IM-05-IN8-RHUSSMANNIM-05- E N 4 - R HILL PHOENIXSSGC-SSC-8 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D 48x18x60 L48x18x60 L48x18x60 L24x18x60 L WRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR LH U S S M A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R. MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RL HUSSMANN RL 4DR RL HUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC MEAL SOLUTIONS(WALK AROUND)HUSSMANNIM-04-E5-RH U S SM A NNIM-04-C6-RHUSSMANNIM - 0 4- C 6 - RHUSSMANNIM - 0 4 - C 6 - RHUSSMANNIM - 0 4 -C 6 - R HUSSMANQ4BV 10' RL HUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCLUDES 4'PRODUCE DRINKS6'RE F R IG E R A T E DWINE W/ WINEHOLDER20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK C ASE S 12' DRINKSHILL PHOENIXON5DM-NRG-12HILL PHOENIXON 5 D M-N RG-8 HILL PHOENIXON5DM-NRG-8HILL PHOE NI X ON5DM-NRG-12PASTASAUCE/SOUPS35PF CR MS 24" 6 PF-5 EWC PF-11,13 PF-16 10 PF-18 10 PF-3 PF-20 10 +45" PF-42 PF-34,36 40 PF-1 5 GF/48" DETAIL "A" 36 (TYP.) CR-11 IG CR-9 IG CR-7 IG CR-5 IG CR-3 IG CR-1 IG PF-22 PF-24 PF-26 PF-14 27 GF GF GF 5 +45" 48" GF PF-38,40 40 118" 118" 118" 24" PF-28 37 WG/24" 9 LB-28 PF-30 L6-20R L6-20R 24 GF/48" 40PF-17 42 42 PF-15 E105 3 E105 2 (E) P (E) G (N) HSB (R)LSB (R) 300kVA T1 NEW 1200 AMP, GFCI BREAKER IN NEMA 3R ENCLOSURE PDS DETAIL "A" SC-29 IG IG IG IG 28 PA-24(P)9 28 28 28 28 IG SC-31 7 PA-32,34,36 PA-28 PA-26 WG/54" L15-20 WG/54" PA-30 WG/54"WG/54"WG/54"14 G-29,31 30/2 PA-38,40,42 PA-25 34 7 L15-20 WG/54" WG/54" PA-31 PD-23 SC-39 PD-25 WG/56" WG/56" WG/56" PD-27 WG/56" PC-35,37 41 L14-20R PF-21 PF-23 PF-19 CR-21 IG/48" PF-44 PF-46 PF-48 E105 1 PF-9 PF-7 39 (4)-L6-15RPF-37,39 PF-33,35 PF-29,31 PF-25,27 CR-19 IG 1 PF-49,51 PF-53,55 PF-41,43(2)L14-20RPF-45,47 3917 21 PF-60 GF PB-29 PF-50 PF-54 PF-52 2 2 2 2 PF-58 18"PF-56 18" 20 PA-11 PA-13 PA-17 PA-24(P)9 USB/48" USB/48" USB/18" USB/18" 24"PA-9 GF/48" GF/48" GF/48" 25 29 29 USB/18" USB/18" GF/48" PA-7 20 24"GF 43 48" GF PA-3 +45" PA-21 EWC +45" PA-1 PA-5 5 +48" +48" 16 P-15,17,19 60/3 PA-22 WG/48" 13 LIGHTING INVERTER 4 G-12 B G-8(P) 9 LSB-16 44 4 L1-42 56" PA-656" E114 2 SC-20 IG/48" 56" PD-29 56" 9 PA-39,41 L14-20R L14-30R PC-28,30 23 IG SC-28 PD 49 (E)P-9,11,13 45 (E)G-26 G-4 18 18 G-6 18 G-2 G-10 19 G-8(P)9 G-14 11 PA-19 32 22 22 22 3 G-16 51 (E)G-24 (E) (E) (E) PA EMC OVERRIDE ALARM PANEL PA-2 SC-1 IG/48"ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 ETR DF-1 52 52 52 52 52 ETR DF-1 52 1. ALL EXPOSED CONDUIT SHALL BE ROUTED PARALLEL TO PERPENDICULAR TO THE STRUCTURE. ANY REQUIRED CHANGE OF DIRECTION SHALL BE 90 DEG. NO 45 DEG OR CROSS RUNS ARE ALLOWED. GENERAL NOTES SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana POWER PLAN E-104 BSD DSP 12/08/2021 02/07/22 HOBARTOV500G2-EE HOBARTPW2E-41 D D D D MEAT & SEAFOOD COOLER BAKERY PREP BAKERY COOLER HUSSMAN Q4BV 10' RL HUSSMANN RL 2DR ID 5 S L 20 9 88" PB-1,3,5 PB-13 11 TO EF3 PB-6 WG/24" PB-4 WG/48" 88" PB-7,9,11 10 PB-2 WG/48" PB-8 WG/48" WG/48" GFIG IG GF/72" SC-27 4 PB-10 PA-24(P) 6 SUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTY SALADSORDER F R R H R N H H H H R H 20' CHEESE DISPLAY GREENSDISPLAY HUSSMANNQ3.5-SS-6RHUSSMANNQ3 . 5 - S S - 4 RRHUSSMANN Q3.5-SS-90R BERRY BINBERRY BINSC REF'G BERRY ATLANTIC FOOD BARSHHDD5136-TFMAISLE BAKERY SERVICE AISLE BULK/COFFEE/CANDY SALES DELI PREP MS-15 MS-17(P) MS-13 MS-1 MS-3 IG MS-2(P) GF GF MS-7 GF MS-19 SC-11(P) IG IG GF SC-35(P) SC-18 MS-2(P) MS-6 MS-8 MS-4 IG 5 6- 3 0 R MS-35,37 MS-27GF/48"MS-69(P) MS-23,25 MS-69(P) 13 SC-24(P) IG IG 18"GF/48"6- 3 0 R 48"4 8 " 3 IG IG SC-24(P) 13 GF/48"MS GF MS-29 MS-31 MS-33 IG SC-22 MS-70 4 8 "18"WP 78" MS-9 MS-11 48" 96" 6-20R MS-58,60 48" GF GF GF GFMS-50 MS-48 MS-52 MS-54 7 7 7 7 GF MS-24 MS-30,32 L6-20R GF MS-28(P)IG 13 SC-26(P)48" GF 48" MS-26 IG 13 SC-26(P) MS-42 18" IG SC-35(P) IG 5 GF GF L6-30R MS-16,18 MS-34 MS-36 MS-40 48" 48" IG 13 SC-22(P) 48" GF/48" 13 SC-26(P) 48" MS-17(P) 13 SC-24P) MS-12 MS-56 18" 48" MS-20 GF GF GF MS-10 GF 12 GF GF 12 GF GF MS-14 MS-39 12 GF GF 12 MS-41 MS-28(P) MS-43 18" KEY NOTES 1 CONNECT TO HOOD LIGHTING. WIRE TO HOOD MOUNTED JUNCTION BOX FOR LIGHT POWER. 2 CONNECT TO HOOD CONTROLS CIRCUIT. REFER TO MECHANICAL SHEET M501-M511 AND ENERGY MANAGEMENT DRAWINGS FOR MORE INFORMATION. 3 PROVIDE AND INSTALL 6” ID CONDUIT, FOR BEER LINES, FROM BEER COOLER TO THE BEER TAPS. REFER TO ’NSD’ MARKET SQUARE DRAWINGS FOR ADDITIONAL REQUIREMENTS. 4 MOUNT RECEPTACLE IN AN ABOVE-FLOOR CAST BOX. SEE DETAIL 3/E105. 5 CONNECT TO FACTORY JUNCTION BOX FOR POWER TO CASE IG RECEPTACLES. 6 RECEPTACLE FOR BUG LIGHT. PROVIDE CORD AND PLUG AND CONNECT TO BUG LIGHT. MOUNT BUG LIGHT AT 80” AFF TO BOTTOM UNLESS OTHERWISE NOTED. 7 CPC BOARD MOUNTED INSIDE DELI HOOD CONTROL PANEL. ALL CONTROL WIRING BETWEEN CPC BOARD AND DELI HOOD CONTROL PANEL PROVIDED AND INSTALLED BY THE REFRIGERATION CONTRACTOR. 8 EC TO PROVIDE A CORD FOR DIRECT EQUIPMENT CONNECTION. 9 MAIN POWER CONNECTION TO PROOF BOX. PROVIDE CORD AND CONNECT TO PROOF BOX. RUN A FULL SIZE NEUTRAL FOR CONNECTION TO THE CONTROLS TRANSFORMER. 10 MAIN POWER CONNECTION TO RACK OVEN BLOWER. PROVIDE CORD AND CONNECT TO OVEN. RUN A FULL SIZE NEUTRAL FOR CONNECTION TO CONTROLS TRANSFORMER. 11 120V CONTROL POWER CONNECTION FOR OVEN AND EXHAUST FAN. SEE DETAIL 3/E113. CONNECT TO EQUIPMENT WITH LFMC. 12 CONNECT FACTORY MOUNTED RECEPTACLE AT BASE OF CASE. 13 RECEPTACLE FOR MEDIA PLAYER MENU BOARDS MOUNTED AT 96"AFF. VERIFY AND COORDINATE MOUNTING LOCATIONS WITH FOOD SERVICE DRAWINGS. 14 BLAST CHILLER IS PROVIDED WITH A POWER CORD. EC TO PROVIDE A RECEPTACLE AND MATCHING RIGHT ANGLE PLUG. VERIFY RECEPTACLE/PLUG CONFIGURATION WITH MANUFACTURER PRIOR TO PURCHASE. 15 EC TO PROVIDE A CORD AND MATCHING RIGHT ANGLE PLUG FOR THE, ALTO SHAM OVEN, FRYER AND TILT KETTLE..B B/CDOUBLECOMBI12GC/OID5SLID5SLID5SLKITCHEN COLD COOKED PREP PDS-27,29,31 PD TO EF-1 ON ROOF TO MUA-1 ON ROOF PD-2 PD-4 1 2 30" PD-14 7 H-2,4,6 15-50R 6-20R 15-50R PDS-18,20 PDS-19,21,23 PDS-10,12,14 15-50R 15 PDS-3,5,7 PDS-11,13,15 42"60" 30" 30" PDS 42" 42"PDS-24,26 8 PDS-11,13,15 60" 15 14 L15-30R PDS-33,35,37 PD-3WG/48" WG/48" 312 C3 10'-0" H-8,10,12 WG/48" SC-25 PD-5 IG/WP 48" PD-11 PD-13 PD-15 PD-17 WP 18" PD-19 WP/18"PD-7 WG 48" PD-21 WG 48" WG/48" 1. ALL EXPOSED CONDUIT SHALL BE ROUTED PARALLEL TO PERPENDICULAR TO THE STRUCTURE. ANY REQUIRED CHANGE OF DIRECTION SHALL BE 90 DEG. NO 45 DEG OR CROSS RUNS ARE ALLOWED. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HOOD FIELD WIRING CONNECTIONS. REFER TO HOOD DRAWINGS ON THE M501-M511. GENERAL NOTES SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana POWER PLANS E-105 BSD DSP 12/08/2021 02/07/22 1 DISCONNECT SWITCH PROVIDED WITH RTU AND WIRED BY ELECTRICAL CONTRACTOR. 2 480 VOLT, 3 POLE, NEMA 3R, 30 AMP, FUSED SAFETY SWITCH, FUSE AT 15 AMPS. 3 208 VOLT, 3 POLE, NEMA 3R, 30 AMP, FUSED SAFETY SWITCH, FUSED AT 30 AMPS. 4 208 VOLT, 2 POLE, NEMA 3R, 30 AMP, FUSED SAFETY SWITCH, FUSED AT 25 AMPS. 5 TWO SPEED FAN DISCONNECT SWITCH IS FACTORY INSTALLED AND SHALL BE WIRED BY ELECTRICAL CONTRACTOR. SEE DETAIL 2/E106. 6 208 VOLT, 2 POLE, NEMA 3R, 30 AMP, FUSED SAFETY SWITCH, FUSED AT 15 AMPS. 7 DISCONNECT SWITCH PROVIDED WITH FAN AND WIRED BY ELECTRICAL CONTRACTOR. 8 RUN 3#12, #12 GND IN 3/4" C. TO ASSOCIATED INDOOR FAN COIL UNIT FOR POWER AND CONTROLS. INSTALL PER MANUFACTURERS INSTRUCTIONS. 9 EXHAUST FAN SHALL BE CONTROLLED VIA EMS SYSTEM TO RUN ONLY DURING OCCUPIED HOURS. SEE DETAIL 2/E113. 10 CONDENSER PROVIDED WITH WEATHER PROOF CONTROL PANEL AND DOOR ACTIVATED DISCONNECT SWITCH. 11 208 VOLT, 3 POLE, NEMA 3R, 30 AMP, FUSED SAFETY SWITCH, FUSED AT 15 AMPS. 12 FAN SHALL BE POWERED FROM BAKERY OVEN. SEE DETAIL 3/E113. 13 FAN CIRCUIT SHALL BE RUN THROUGH TWO SPEED CONTROLLER AND MOTORIZED DAMPER CIRCUIT SHALL BE RUN THROUGH CONTACTOR, BOTH FACTORY INSTALLED IN THE POWER PLUS UNIT. SEE DETAIL 2/E106. 14 RUN 2 #12 PLUS GROUND IN SEPARATE 3/4" CONDUIT DOWN TO HOOD CONTROL PANEL FOR FAN CONTROLS. SEE HOOD DRAWINGS FOR ADDITIONAL INFORMATION ON THE HOOD REGULAR AND LOW VOLTAGE POWER REQUIREMENTS. 15 RUN CIRCUIT THROUGH THE CONTACTOR FOR THE DISHWASHER CIRCUIT TO INTERLOCK FAN OPERATION WITH THE OPERATION OF THE DISHWASHER. SEE E104 FOR ADDITIONAL INFORMATION. 16 480 VOLT, 3 POLE, NEMA 3R, 30 AMP, FUSED SAFETY SWITCH, FUSE AT 15 AMPS. 17 EQUIPMENT IS EXISTING TO REMAIN. 18 EXISTING TO REMAIN MOTOR ROOM EXHAUST AND PURGE FANS. EXISTING CPC CONTROLS ARE ALSO TO REMAIN AND SHALL BE RECONNECTED TO NEW CPC CONTROL SYSTEM. 20 WIRE RECEPTACLE TO NEAREST EXISTING ROOF RECEPTACLE CIRCUIT, PRESUMED TO BE G-32. KEY NOTES (E) H-1,3,5 10 P-20,22,24 PF-70,72 8 6 12 7WP 17 HSB-9 P-8,10,12 10 PF-68(P) WG G-36 9 7 17 (E) (E)G-32 H-13,15,17 2 2 PF-68(P)WG 15 7 7 H-2,4,6 14 H-8,10,12 14 PA-33 PA-35 9 7 REL. FAN COIL OUTDOOR UNIT ETR RTU-2 ETR RTU-3 ETR EF-9 ETR EF-8 ETR RTU-1 (E) (E) (E) H-7,9,11 17 (E) (E) (E)G-32 H-25,27,29 18 (E)G-20 (E) (E) (E) H-2,4,6 2 H-25,27,29 WG WG (E)G-32 (E) H-14,16,18 2 2 PD-42 PD-42 20 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ROOF POWER PLAN E-106 BSD DSP 12/08/2021 02/07/22 1 DOOR LIMIT SWITCH ON FREEZER DOORS PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER. MOUNT AND CONNECT PER REFRIGERATION SPECIFICATIONS. 2 RECEPTACLE FOR DRAIN LINE HEATER. 3 CONNECT TO DOOR HEATER CABLE. 4 CONTRACTOR SHALL CIRCUIT REFRIGERATED CASE UL LISTED LOAD CENTER PROVIDED WITH THE EQUIPMENT. REFER TO KITCHEN SERVICES DRAWINGS FOR ADDITIONAL INFORMATION. 5 CONTRACTOR TO ROUTE CONDUIT HORIZONTALLY INSIDE WALL FROM CHASE TO JUNCTION BOX MOUNTED AT EACH CASE. REFER TO DETAIL 3 DRAWING EM103. 6 MOUNT ON CEILING NEXT TO BLOWER COIL UNIT. KEY NOTES 1 PROVIDE 200LB PULL STRING IN ALL EMPTY CONTROLS CONDUIT. 2 REFER TO G001, R001 AND EM001 FOR RESPONSIBILITY MATRICES THAT DELINEATES SCOPE BETWEEN SUBCONTRACTORS. 3 ROUTE ALL CONDUIT ALONG SIDE OF REFRIGERATION DROPS. 4 POWER CONDUCTORS AND CONTROL CONDUCTORS SHALL BE RUN IN SEPARATE CONDUITS. SHEET NOTES 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B B C C D D E E F F G G A A Z Y R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) DELLFRIOEFE-5052HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HONHC1872 ATLANTIC FOOD BARSHHDD5136-TFM HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D 48x18x60 L48x18x60 L48x18x60 L24x18x60 LWRAPPING BOARD UP UP MEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R. MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR CHASE CHASE CHASE CHASE CHASE CHASE L F L F L F L F L F L F L F L F L F L F L F L F LF LF R1-1 LB-37 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 R1-1 LB-37 R1-3 LB-39 R1-3 LB-39 R1-3 LB-39 R1-5LB-41R1-18 LB-74 R1-6 LB-42 R1-10 LB-46 R1-10 LB-46 R1-12 LB-48 R1-12 LB-48 D D D D D D LS LS 3#12 IN 3/4" C TO PNL LB 2#10, 1#10 GND IN 3/4" C TO DEFROST CONTROL PANEL 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 3#12 IN 3/4" C TO PNL LB F L R1-7LB-434#12 W/ 1#12 GND IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL LB FL R1-9LB-45F L R1-9LB-45FLFLF L 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB R 1- 11 L B - 4 7 R 1 - 1 1 L B - 4 7 R1-11LB-472#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL F L R1-13LB-49F L R1-15LB-51F L R1-17LB-536#12 W/ 1#12 GND IN 3/4" C TO PNL R1 6#12 W/ 1#12 GND IN 3/4" C TO PNL LB FLR1-19LB-55 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL LFR1-21LB-57FLFLFLFLR 1 - 2 3 L B - 5 9 R 1- 2 5 L B - 61 R 1 - 2 5 L B - 6 1 R 1 - 2 5 L B - 6 1 LFR1-21LB-57F L R1-27LB-63F L R1-31LB-67F L R1-31LB-67F L R1-33LB-69F L R1-33LB-696#12 W/ 1#12 GND IN 3/4" C TO PNL R1 6#12 W/ 1#12 GND IN 3/4" C TO PNL LB F R1-35L F R 1 - 3 9 L B- 3 8 LFR 1 - 39 L B - 3 8 L FR1-39 LB-38 LFR1-39LB-38LFR1-39LB-38FR1 -41FR1-2LFR1-8LB-44LFR1-8LB-44LFR1-8LB-44LFR1-8LB-44LFR 1 - 8 L B - 4 4 FLR1-4LB-40FLR1-4LB-40 R 1 - 4 LB-40R1-4L B- 4 0 LFR 1 - 2 0 L B - 7 6 L F R 1 - 2 0 L B - 76 F L FL R1-20LB-76R1-20LB-76L F R 1 - 1 4 L B - 7 0 L F R 1 - 1 4 LB - 7 0 F L F L R1-14LB-70R1-14LB-70L F R 1 -1 6 L B - 7 2 F L R1-16LB-72L F R 1 - 1 6 L B - 7 2 FL R1-16LB-724#12 W/ 1#12 GND IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL LB 4#12 W/ 1#12 GND IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL LB 4#12 W/ 1#12 GND IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL LB 1/20 R1-22 2/20 2/35 2#8, 1#10 GND IN 1" C TO DEFROST CONTROL PANEL 2/20 2/201/20 R1-34 1/20 R1-32 1/20 R1-36 2/20 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL LS R2-1 2/20 1/20 R2-3 1/20 R2-7 1/20 2/20 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 2/20 R2-9 1/20 1/20 R2-29,31 2/20 2/25 2#10, 1#10 GND IN 3/4" C TO DEFROST CONTROL PANEL R1-38 R1-40 R1-42 TYPICAL D 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL 3#12 IN 3/4" C TO PNL LB L F R1-5LB-41D 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL R1-37 2/20 2/35 2#10, 1#10 GND IN 3/4" C TO DEFROST CONTROL PANEL 2#12, 1#12 GND IN 3/4" C TO DEFROST CONTROL PANEL L F R1-29 LB-78 3#12 IN 3/4" C TO PNL LB 3#12 IN 3/4" C TO PNL R1 L F R1-29 LB-78 FFF R 1 - 2 4 R1-24R1-243#12 IN 3/4" C TO PNL R1 H H H H R1-17HR1-41HR1-39HR1-39HR1-39 HR 1 - 3 9 HR 1 - 3 9 HR 1 - 2 4 HR1-24H R1-24H H HH H R1-26 R1-26 R1-26R1-28R1-28R1 -30 R2-11R2-134#12 W/ 1#12 GND IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL R1 4#12 W/ 1#12 GND IN 3/4" C TO PNL R1 3#12 IN 3/4" C TO PNL R2 3#12 IN 3/4" C TO PNL R2 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana CASE POWER AND LIGHTING PLAN E-107 BSD NGS REFRIGERATED DEFROST CIRCUITING SCHEDULE (RDCS) CIRCUIT ID DESCRIPTION DEFROST LOAD DEFROST CIRCUIT FAN CIRCUIT TYPE LOAD(KVA) QTY BREAKER(S) CONTACTOR(S) MIN WIRE SIZE LOAD(VA) QTY BREAKER(S) CONTACTOR(S) MIN WIRE SIZE A1 -A,B Freezer, Bakery (252 sf)E 6.3 2 2P-35A 2P-35A #8 624 1 2P-15A 2P-15A #12 A2 -A Freezer, Ice Cream (73 sf)E 3.2 1 2P-20A 2P-20A #12 312 1 2P-15A 2P-15A #12 A3 -A Freezer, Meat/Seafood (57 sf)E 2.1 1 2P-15A 2P-15A #12 208 1 2P-15A 2P-15A #12 A5 -A RL w/ Innovator Doors - Seafood - 3 doors E 2.1 1 2P-20A 2P-20A #12 A6 -A RL w/ Innovator Doors - Ice Cream - 2 doors E 1.4 1 2P-15A 2P-15A #12 A7 -A RL w/ Innovator Doors - Bakery - 2 doors E 1.4 1 2P-15A 2P-15A #12 A8 -A,B,C RL w/ Innovator Doors - Ice Cream - 13 doors E 9.1 1/2 2P-20A / 2P-30A 2P-20A / 2P-30A #12 / #10 A9 -A,B RL w/ Innovator Doors - Ice Cream - 8 doors E 5.6 2 2P-20A 2P-20A #12 B4 -A Cooler, Cold Cooked (87 sf)E 2.8 1 2P-20A 2P-20A #12 166 1 2P-15A 2P-15A #12 3 LARGEST DEFROST CIRCUIT KVA = 21.0 12/08/2021 02/07/22 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B/CDOUBLECOMBI12GC/OSUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTY SALADSORDER F R R H R N H H H H R H 20'CHEESE DISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSS M A N N Q3 . 5 - S S-4RRHUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR FRE-706FRE-706 FRE-705 BRM-712 FLO-409 FLO-409 FLO-409 FRE-706 FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708FRE-711 GRO-563 BCC-423 GRO-563 GRO-562 GRO-407 a GRO-407 a GRO-407 a GRO-409 GRO-562 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-039 FRE-707 BWL-4WF GRO-556 GRO-4XX GRO-556 GRO-554 GRO-568 GRO-554 GRO-554 GRO-554 GRO-554 GRO-554 GRO-554 GRO-554 GRO-554 GRO-554 FRE-706 GRO-4XX GRO-048 GRO-4XXGRO-4XX GRO-048 GRO-4XX GRO-4XX GRO-4XX FRE-802 FRE-803 FRE-802 FRE-803 FRE-802 GRO-4XX GRO-XXX DRY-900 DRY-515 DRY-515 BKY-900 BKY-424 BKY-801a MEA-026 MEA-023 a SFD-030 SFD-064SFD-065 SFD-057 MEA-025 MEA-405 MEA-533 SFD-406 BKY-201 BKY-202 BKY-532BKY-532BKY-532BKY-532 BKY-206 BRM-712 BKY-316 BKY-801 b BKY-3XX MEA-204 MEA-337MEA-337 MEA-337 MEA-339 MEA-340MEA-340 MEA-205MEA-201 MEA-310 MEA-337 MEA-338 MEA-311 MEA-900 SFD-325 SFD-900 MEA-203 MEA-521 SFD-518 MEA-520 MEA-515MEA-515 MEA-520 MEA-202 DEL-513 SFD-516 DEL-513 BRM-712 MEA-901 FLO-4XX FLO-XXX FLO-4XX BKY-515 BKY-514 SFD-517 SFD-518 SFD-901 BRM-705BRM-705 BRM-712 FLO-413 FLO-413 PRO-441PRO-441 FRE-706 GRO-4XX GRO-4XX MEA- DEL-0XX DEL-141b MEA-049 b MEA-048 DEL-141a MEA-049 a BWL-541 BCC-438 BCC-438 BCC-4XX BCC-4XX BCC-2XX a BCC-2XX b BCC-2XX c BCC-2XX d GRO-565 GRO-553 GRO-553 GRO-553 GRO-553 GRO-553 GRO-553 GRO-553 GRO-553 GRO-553 BCC-202 a GRO-407 c BCC-542 BCC-543 BCC-544 BCC-543 BCC-544 BCC-542 BCC-542 BCC-542 BCC-542 BCC-542 BCC-542 BCC-542 GRO-4XX BCC-XXX BCC-XXX BCC-4XX BCC-4XX BCC-4XX BCC-2XX d BCC-2XX c BCC-2XX b BCC-2XX a BCC-2XX h BCC-2XX g BCC-2XX f BCC-2XX e BCC-4XX BCC-4XX DEL-524 DEL-526 BRM-506 BRM-506BRM-506 BRM-504 BRM-504 BRM-504 BRM-734 BCC-202 b FLO-409 SFD-517 BKY-331 DEL-105 BRM-504 FLO-412 RES-701RES-701 FRE-802 RES-500RES-500 OFF-501 OFF-401a OFF-506 OFF-507OFF-507 BWL-441a FLO-900 FLO-XXX PRO-332 PRO-334 PRO-336 PRO-335 PRO-332 PRO-900 PRO-523PRO-523 DEL-513 DEL-514 DEL-514 DEL-514 DEL-513 PRO- PRO-0XX b PRO-0XX PRO-0XX a GRO-0XX PRO-901 PRO-438 GRO-410 FRO-400 a BWL-426 a BKY-033 BKY-034 BWL-018 FRO-063 FRO-064 FRO-066b FRO-066 a FRO-067 FRO-068 PRO-050 b PRO-050 c PRO-050 d PRO-051 PRO-052 BKY-035 BWL-021 FRO-067 FRO-065 a FRO-068 DRY-057b DRY-057 a DRY-058 SFD-0XX SFD-062 SFD-0XX PRO-304 PRO-305 PRO-322 PRO-204PRO-202PRO-205 PRO-203 PRO-801 PRO-524 PRO-524 PRO-523PRO-524 PRO-523 BRM-506GRO-056 GRO-4XXGRO-4XX GRO-4XX GRO-547 GRO-547 GRO-565 PRO-531 PRO-533 FLO-413 MEA-312 FLO-423b FLO-431 FLO-514FLO-514FLO-514 FLO-430 FLO-4XX FLO-4XX FLO-4XX BWL-426 b SFD-3XX DEL-300 SFD-326SFD-310 PRO-333 ODS-501ODS-501 SFD-408 a SFD-326 BRM-506 PRO-523 PRO-524 BCC-444 ODS-510 ODS-512 ODS-512ODS-512 ODS-512 NETWORK FOR SQUARE TO GOON MEZZ PRO-440 PRO-435 BRM-512 BRM-513 MEA-331 BRM-728 BKY-901 BRM-726BRM-726 BRM-727 MEA-530 MEA-528 BRM-711 BRM-509BRM-509BRM-509 DRY-400 a DRY-059 BKY-203 BKY-030 BKY-031 BKY-032 FRO-067 FRO-068 BWL-0XX BKY-205 BKY-327 a PRO-427 PRO-428 PRO-424 PRO-424 PRO-426 PRO-427 PRO-428 PRO-426 PRO-429 PRO-429 PRO-430PRO-430PRO-430PRO-430PRO-430PRO-430 PRO-048 g PRO-048 h PRO-048 i PRO-048 j PRO-048 c PRO-048 d PRO-048 e PRO-048 f GRO-5XX GRO-5XX GRO-5XX GRO-5XX GRO-5XX BCC-439 BCC-441 ODS-511 ODS-510 ODS-512 ODS-512ODS-512ODS-512 ODS-511 ODS-510 ODS-512 ODS-512ODS-512ODS-512 ODS-509 BKY-322 DRY-400bFRO-400b DEL-4XX PRO-048 a PRO-048 b PRO-050 a BKY-XXX DEL-0XX DEL-0XX DEL-0XX DRY-058 DRY-059 BKY-331 SFD-061 SFD-059 SFD-063 SFD-3XX DEL-409a FRO-065b SFD-309 MEA-801a MEA-801b MEA-801c SFD-801a BWL-0XX BWL-0XX GRO-0XX DEL-0XX DEL-0XXa GRO-0XX DEL-0XXb DEL-0XX GRO-703 PRO-701 BWL-426 c FRO-400 c DEL-409b BCC-XXX GRO-569 BWL-0XX BCC-4XX BCC-4XX FLO-412 BKY-0XX BKY-0XX BKY-0XX BKY-511 BKY-533 BKY-511 BKY-533BKY-533BKY-533 BCC-900 GRO-560 GRO-561 GRO-552 GRO-552 GRO-552 GRO-4XX GRO-0XX GRO-0XX GRO-407 b GRO-0XX GRO-0XX GRO-0XX ODS-505 ODS-505 BCC-400 BCC-400 SFD-801b MEA-328 DEL-323 DRY-514 BKY-515 BKY-515 BKY-204 BCC-4XX GRO-564 GRO-573 BRM-504 BRM-504 BRM-509 FLO-423c FLO-423a DEL-513 GRO-574 GRO-574 DRY-515 GRO-574 GRO-574 DRY-514 DRY-514 GRO-573GRO-573 BKY-3XX GRO-574GRO-574 BRM-712 BKY-311 BKY-425BKY-425 BKY-4XX FRE-708FRE-708FRE-708FRE-708FRE-708FRE-708 DRY-514 BWL-018 BWL-020 a BWL-413 GRO-564 DRY-0XX GRO-901 PRO-523 PRO-202DEL-220 MEA-801d MEA-334 SFD-408b BKY-515 BKY-515 GRO-562 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-556 GRO-563 GRO-572GRO-572 BKY-311 BKY-327 b FLO-431 BCC-514 BCC-513BCC-513 BWL-023 BRM-506 BKY-527 BKY-529 GRO-407 a BKY-425 MEA-023b SFD-013 MEA-4XX MEA-0XX MEA-0XX MEA-0XX PRO-440 PRO-435 FLO-4XX BWL-413 BKM-201 BRM-712 BKM-404 a BKM-200BKM-406 IDS-200 IDS-406 FRE-706FRE-706FRE-706 BRM-506PRO-421 PRO-422 PRO-421 PRO-422 OFF-401b OFF-506 OFF-507OFF-507 BRM-505 BRM-710 PRO-424 DEL-408PRO-421 PRO-421 PRO-422PRO-422PRO-422PRO-422PRO-422PRO-422PRO-422PRO-422 PRO-421 PRO-421 PRO-421 PRO-421 BWL-4WE10 BWL-4WG.2 BWL-4WG.1BWL-4WG.1BWL-4WG.1 BWL-4WG.2BWL-4WG.2 PRO-523 PRO-523 BRM-504 BWL-4WE BWL-4WE BKM-514BKM-514BKM-514BKM-514 BKM-513BKM-513 BKM-514BKM-514BKM-514BKM-514 BKM-513BKM-513BKM-513BKM-513BKM-513BKM-513BKM-513BKM-513 BKM-514BKM-514BKM-514 BKM-514 BKM-514BKM-514BKM-514 BKM-514 BKM-514BKM-514BKM-514 BKM-514 BKM-515 BKM-XXX BKM-515BKM-515BKM-515BKM-515BKM-515 BCC-700 BCC-300 BCC-801 BRM-504 BRM-509BRM-509 GRO-4XX RES-701 RES-701 BKM-514 BKM-514 BKM-513 BKM-404 b BWL-020 b BWL-020 c BWL-4XX BWL-4WBBWL-4WBBWL-4WB BWL-4WBBWL-4WBBWL-4WBBWL-4WC BWL-4WB BWL-4WB BWL-4WC BWL-4WDBWL-4WD BWL-4WD BWL-4WD.1 FRE-706 FRE-708FRE-708 FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710FRE-710 FLO-4XX BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)NESTING TABLES (PLANT SET) SC R E F ' G B E RRY BI NSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC R EF' G B E RRY BI NSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12 HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANN IM- 0 5 - E N 4 - R HONHC1872ATLANTIC FOOD BARSHHDD5136-TFM HILL PHOENIXSSGC-SSC-8 HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D 48x18x60 L48x18x60 L48x18x60 L24x18x60 L WRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR LH U S S M A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R.MEN'S R.R. ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED COOLER FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RL HUSSMANN RL 4DR RL HUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC M E A L S O L U T IO N S(WALK AROUND)HU S S MAN N IM-04-E5-RHUSSMANNI M - 04 - C 6 - R H U S SM A N NIM-04-C6-RHUSSMANNIM-04-C6-RHUSSMANNIM-04-C6-RHUSSMANQ4BV 10' RLHUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCL U D ES 4'PRODUCE DRINKS6' R E F R IG E R A T E DWINE W/ WINEH O L D E R 20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK CASES12' DRIN K S HILL PHOENIXO N 5DM- N RG-12HILL PHOENIXO N5D M- NR G -8HILL PHOENIXON5DM-NRG-8HILL PHOENIXO N 5DM- N RG-1 2 PASTASAUCE/SOUPSPS17/54" PS14/54" 1/2" C. TO EMS AT FCU-1 14 14 1/2" C. TO RTU-2 ON ROOF 1/2" C. TO RTU-5 ON ROOF 1/2" C. TO RTU-4 ON ROOF REGISTER 1REGISTER 2REGISTER 3REGISTER 4REGISTER 5REGISTER 626 26 26 26 26 26 26 1 PUBLIC WI-FI (MOUNTED AT CEILING)12 12 13 48" 48" 48"48" 7 PS16/54" 17 5 PS13/36"27 ANT.- 4 ANT.- 8 ANT.- 7 ANT.- 6 13 7 1 EXTEND CONDUIT TO ABOVE CEILING ANT.- 11 ANT.- 14 3 PS9/54" 22 CK17/54" 12 ANT.- 1 ANT.- 3 ANT.- 2 ANT.- 10 ANT.- 9ANT.- 5 WAP-3/B21 MOUNT IN DROP CEILING 8 9 10 11 18 2 AP-WI(3) B21 AP-WI(2) B18 AP-WI(1) B-18 4 PS19/54" PS18/54" PS18/54" WAP-3/B3 2 22 4 4 25 PS20/54" B10/54" 19 19TC-3 48" 17 17 17 17 4 3/4" C. FROM EMC OVERRIDE ALARM PANEL TO RACK A CONTROL BX-400. 23 24 SSH S S S S SS H S 1/2" C. TO RTU-1 ON ROOF PF CR 14 14 15 1414 15 18 20 48"17 1/2" C. TO RTU-1 ON ROOF 1/2" C. TO RTU-6 ON ROOF12 13 2 1/2" C. TO (E) RH-1 IN DOCK AREA 1/2" C. TO RTU-3 ON ROOF PS15/54" G F 15 6 21 29 S S S S 9 11 11 10 S16 SGENERAL NOTES 1. DATA CABLING SHALL BE CAT 6 PER TFM SPECIFICATIONS. 2. UNLESS OTHERWISE REQUIRED, SUPPORT CABLING FROM ROOF JOISTS WITH J-HOOKS OF CABLE TIES. 3. NO TELEPHONE OUTLETS OTHER THAN T1-T8 SHOWN ON THIS SHEET. DO NOT INSTALL ANY ADDITIONAL OUTLETS UNLESS REQUESTED BY TFM. 4. WIRING INDICATED ON THIS SHEET IS TO BE PROVIDED BY TFM’S SELECTED VENDORS AND IS SHOWN FOR COORDINATION ONLY. 5. ALL CONDUIT #’S ( ) ON THIS SHEET ARE SCHEDULED ON THIS SHEET. SEE CONDUIT SCHEDULE AND STUB UP LOCATIONS ON EU102 FOR REFERENCE. 6. THIS DRAWING SHOWS PROPOSED ROUTING FOR TELECOM/DATA CONDUITS. COORDINATE FINAL ROUTING WITH FIELD CONDITIONS. 7. PROVIDE RACEWAYS, DEVICE BOXES AND PULL STRING IN ALL CONTROL & DATA CONDUITS. 8. EXTEND CONDUITS UP TO JOIST LEVEL OR RIGHT UNDER MEZZANINE AND THEN RUN WIRING WITHOUT CONDUIT UP IN THE JOISTS. 9. ALL CONDUITS SHALL BE CONCEALING IN WALLS AND TERMINATE IN FLUSH MOUNTED J-BOXES AT HEIGHT SPECIFIED (IN PLAN OR KEYNOTES). AT EGRESS DOORS, EXTEND WITHIN FRAME TO LATCH SIDE JAMB. KEY NOTES 1 FOR REGISTERS, ALWAYS PROVIDE FOR AT LEAST 1 ADDITIONAL REGISTER MORE THAN SHOWN ON PLANS. COIL SPARE CABLE IN U\ST CHECKSTAND FOR FUTURE USE. 2 WAP LOCATION. 3 BOX AND CONDUIT ONLY FOR FUTURE TELEPHONE. 4 STUB 3/4”C TO TOP OF COOLER. SEE DETAIL 6/E113. 5 CONDUIT STUBBED UP BELOW TELEPHONE BOARD IN MEZZANINE. 6 LOW VOLTAGE CONDUIT STUBBED UP INTO MEZZANINE BELOW TELEPHONE BOARD. SEE DETAIL 3/EU102. 7 COORDINATE LOCATION WITH PULL STATION FOR HOOD FIRE SUPPRESSION SYSTEM. 8 STUB LOW VOLTAGE CONDUITS THRU MEZZANINE FLOOR AT THIS LOCATION. 9 WATER HEAT RECLAIM TANK MOUNTED TEMPERATURE SENSOR. VERIFY LOCATION. 10 WATER HEATER OUTLET PIPING MOUNTED TEMPERATURE SENSOR. VERIFY LOCATION. 11 CONNECT CONDUIT TO HOT WATER LINE FLOW SWITCH. 12 1/2” EMT FOR AUTO DOOR SECURITY FROM DOOR OPERATOR TO JUNCTION BOX LOCATED ABOVE VESTIBULE CEILING. 13 3/4” CONDUIT WITH PULL STRING FOR LOW VOLTAGE WIRING STUBBED ABOVE VESTIBULE. 14 3/4” CONDUIT WITH PULL STRING RUN IN A LOOP FASHION TO JUNCTION BOXES MOUNTED IN STEEL STRUCTURE UNDERNEATH ROOFTOP UNITS’ LOW VOLTAGE CONTROL CABINETS. 15 1" CONDUIT WITH PULL STRING FROM ROOFTOP UNIT CONDUIT LOOP TO MOTOR ROOM JUNCTION BOX MOUNTED OVER COMPRESSOR RACK. 16 3/4” CONDUIT WITH PULL STRING FROM JUNCTION BOX MOUNTED OVER COMPRESSOR RACK THROUGH GOOSENECK RAIN HOOD CURB TO JUNCTION BOX AT UNDERSIDE OF CONDENSER RACK STEEL SUPPORTS. 17 INSTALL A JUNCTION BOX FOR FOOD SERVICE CONTRACTOR. STUB 3/4”C FROM JUNCTION BOX TO ABOVE ABOVE COOLER BOX WALL. LEAVE A PULL STRING IN CONDUIT. 18 ROUTE LOW VOLTAGE CONDUITS FROM UNDERGROUND UP CHASE ON REAR WALL, THEN ACROSS THE BOTTOM OF THE MEZZANINE THEN UP AND THRU MEZZANINE FLOOR BELOW THE PHONEBOARD ON THE MEZZANINE. 19 PROVIDE SINGLE GANG BOX AND 1" CONDUIT STUBBED INTO JOIST AREA FOR TELE/DATA OUTLETS. COORDINATE LOCATION WITH DEPARTMENTAL DESK. 20 SEE DWG EU101 FOR CONDUIT ROUTING AND STUB-UP AREAS. 21 WIRING TROUGH AT FLOOR LEVEL AND TRANSITION TO (4) 2” CONDUITS FOR FINAL RUN TO REFRIGERATION RACK CONTROL PANELS. SEE DETAIL 3/EU102. 22 WIRING TO BACK END OFFICE PATCH PANEL. 23 MICROPHONE BOH OFFICE AREA (CONNECT TO MUSAK AMP) SEE DETAIL 2/E114 FOR LOCATION AND MOUNTING HEIGHT. 24 STUB UP 2” CONDUIT FROM BOH OFFICE TO ROOF JOIST FOR BACKROOM WIRING. STUB CONDUIT TIGHT AGAINST WALL. 25 MICROPHONE BOH AREA (CONNECT TO MUSAK AMP). 26 MICROPHONE CHECKSTAND AREA (CONNECT TO MUSAK AMP) MOUNT IN CABINET UNDER COUNTERTOP. 27 MICROPHONE FEO (CONNECT TO MUSAK AMP). 28 ROUTE CONTROL WIRING CONDUITS FOR REFRIGERATED CASE TEMPERATURE SENSORS OVERHEAD TO REFRIGERATION RACK CONTROL PANEL. REFER TO REFRIGERATION DRAWINGS FOR ADDITIONAL INFORMATION. 1. SYSTEM WILL BE CISCO 540G. 2. PROVIDE EIGHT PRE-PROGRAMED CISCO IP TELEPHONES. 3. PROVIDED EDCO SURGE PROTECTORS FOR 120V OUTLETS AND FIVE CO LINES. OR ADDITIONAL AS REQUESTED BY THE FRESH MARKET. 4. COORDINATE PAGING WITH MUSIC SYSTEM. 5. CABLING SHALL BE 4-PAIR CATEGORY 5E. ALL WIRES SHALL BE TERMINATED ON A 66M150 BLOCK IN A WORKMANLIKE MANNER. THE 66M150 BLOCK SHALL BE MOUNTED ON AN 89D BRACKET. CABLING SHALL BE ROUTED BETWEEN STANDOFF BRACKET AND BACK OF BLOCK. 6. A SPARE CABLE SHALL BE RUN TO THE F.E. OFFICE, THEN COILED AND LABELED ON BOTH ENDS FOR FUTURE USE. 7. TELEPHONE CABLES SHALL NOT BE INSTALLED IN SAME RACEWAY AS LINE VOLTAGE WIRING. 8. COORDINATE TELEPHONE NUMBERS AND OUTLETS WITH LOCAL TELEPHONE COMPANY. ALLOW ALL TELEPHONES TO DIAL OUT. 9. ALL RUNS FROM PATCH PANEL TO DEPARTMENT PHONES TO BE CAT 5E. 10. FACE PLATES TO BE RJ45. TELEPHONE SPECIFICATIONS SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930564 12/03/2021 10844 SW VILLAGE PKWY PORT ST LUCIE, FL 34987 NO. DATE DESCRIPTION PH: 703-777-5988 552 Fort Evans RD STE 200 Leesburg, VA 20176 www.dwyer.com THE FRESH MARKET STORE #10367 PROJECT NORTH This item has been digitally signed and sealed on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. LOW VOLTAGE DEVICES & WIRING PLAN E-108 BSD DSP CONDUIT SCHEDULE TAG # CONDUIT TYPE OF WIRING NOTES QUANTITY SIZE 1 1 1" TELECOM 1 1a 1 1" TELECOM 1 2 1 2" TELECOM 2 3 1 1" TELECOM 3 4 1 2" TELECOM 4 5 1 1" TELECOM 5 1 1" FIRE ALARM 1 1" SPARE 1 2" SPARE 6 1 2" TELECOM - SEE E109 6 7 1 2" REFRIGERATION CONTROLS 8 1 1-1/2" REFRIGERATION CONTROLS 9 1 1-1/2" REFRIGERATION CONTROLS 10 1 1" REFRIGERATION CONTROLS 11 1 2" REFRIGERATION CONTROLS 12 1 2" REFRIGERATION CONTROLS 13 1 1" REFRIGERATION CONTROLS 14 1 2" REFRIGERATION CONTROLS 15 1 2" CHECKSTAND DATA 7 15a 1 2" CHECKSTAND DATA 7 16 1 2" CHECKSTAND DATA 7 16a 1 2" CHECKSTAND DATA 7 17 1 2" CHECKSTAND DATA 7 17a 1 2" CHECKSTAND DATA 7 18 1 1" REFRIGERATION CONTROLS 19 1 1" TELECOM 7 20 1 1" TELECOM 7 21 2 1" TELECOM 22 1 1" TELECOM 7 23 1 1" REFRIGERATION CONTROLS 24 1 1" REFRIGERATION CONTROLS 25 1 1" TELECOM 7 26 1 1" TELECOM 7 27 1 1" TELECOM 7 27 1 1" TELECOM 7 28 1 1" TELECOM 7 29 1 1" TELECOM 7 30 1 1" TELECOM 7 NOTES LINES IN TELECOM CONDUIT: 1. TELEPHONE 305 TO FLORAL FROM C. #3 2. DSL TO FEO/64K TO FEO/ PHONE PBX TO FEO/ 56K TO FEO/UNICRU DSL TO JUNCTION BOX/TELEPHOE TO FEO/ TELEPHONE 305 TO FLORAL. 3. WAP TO DELI. 4. DATA FROM FEO TO BEO. 5. WIRELESS PHONE ANTENNA FROM PHONE BOARD/ TELEPHONE 304 TO DELI. 6. RJ11 TO BEO MUZAK-PA AND MOH/ FAX LINE FROM PHONE BOARD/ CPC TO BEO PATCH #8/ TELEPHONE 302 TO BEO/ TELEPHONE 303 TO BAKERY. 7. CONDUIT TO BE ROUTED BELOW SLAB. 12/08/2021 02/07/22 12 11 10 9 8 7 6 5 4 3 2 1 23 22 21 20 19 18 17 16 15 14 13 24 12 11 10 9 8 7 6 5 4 3 2 1 23 22 21 20 19 18 17 16 15 14 13 24 2423 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 22 21 20 19 PHONE BOARD 12 11 10 9 8 7 6 5 4 3 2 1 PRIMARY HUNT 1 HUNT 2 FAX FIRE 1 FIRE 2 DSL 66 BLOCK FACILITY FIRE 1FIRE 2TO FAX AT B IN C. #1 TO PORT F19 IN C. #3FXO 2-LINE 3 (ROLLOVER 2)FXO 1-LINE 2 (ROLLOVER 1)FXO O-LINE 1Public WiFi12 PORT PATCH PANEL Coil and terminate above seating area at the front of the store above the ceiling Public Wifi (only if we have a customer seating area) Ceiling area above seating BACK END OFFICE AREA (BEO) PATCH PANEL B (24 PORT) CEILING AREA THROUGHOUT SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana LOW VOLTAGE RISER AND DETAIL E-109 BSD DSP 12/08/2021 02/07/22 FEEDER SCHEDULE - 1/E110 1 4 SETS OF 4-350MCM (CU.) IN 4" CONDUITS. 1200 AMP RETAIL SERVICE METERING EQUIPMENT AND DISCONNECT SWITCH IN MAIN ELECTRIC ROOM. 2 4 SETS OF 4-350 (CU.), 1#3/0 (CU.) GND, IN 3-1/2" CONDUITS. 3 3-500 (CU.), 1#3 (CU.) G. IN 4" C. 4 2 SETS OF 4-600 (CU.), 1#4/0 (CU.) G. IN 4" CONDUITS. 5 4#3, 1#6 G., IN 1-1/2" C. WIRING SHALL BE AS SHORT AS POSSIBLE. 6 4#3, 1#6 GND. IN 1-1/2" C. 7 3#1/0, 1#6 GND. IN 2" C. 8 3#4, 1#8 GND. IN 1-1/2" C. 9 3#4, 1#8 GND. IN 1-1/2" C. 10 4#6, 1#10 GND. IN 1" C. 11 4#1/0, 1#6 GND. IN 2" C. 12 3#10, 1#10 GND. IN 3/4" C. 13 4#1, 1#4 GND. IN 1-1/2" C. 14 4#8, 1#10 GND. IN 3/4" C. 15 4#250, 1#3 GND. IN 3" C. 16 4#4/0, 1#4 GND. IN 2-1/2" C. 17 4#3/0, 1#6 GND. IN 2-1/2" C. (E) UTILITY PAD-MOUNTED TRANSFORMER AND METER 277/480V SECONDARY 4 M 1 1 (E) PANEL LB (Sect1) 208V 250A SMART BREAKER PANEL (E) SILVER BULLET LTG CONTROL PANEL (E) PANEL LB (Sect2) 208V 250A SMART BREAKER PANEL (E) PANEL LA 480V 125A SMART BREAKER PANEL (E) PANEL H 480V 100A 208V PANEL (E) PANEL R1 100A 208V PANEL (E) PANEL R2 208V 100A PANEL (E) PANEL SC 208V 100A PANEL (E) T2 15kVA 480-208V TRANSFORMER (E) 208V, 3P 60A N.F.S.S. (E) 12" x 12" WIRE TROUGH (E) 12" x 12" WIRE TROUGH (E) TVSS (E) (E) (E)(E) (E) (R) LSB 120/208V (R) T1 300kVA 480-208V TRANSFORMER PANEL HSB 1200 AMP DISTRIBUTION SECTION 480/277V FRONT ACCESSIBLE ONLY 480V, 3P 1200A, GFCI BREAKER IN NEMA 3R ENCLOSURE 2 3 4 MEZZANINE MOTOR ROOM GROUND FLOOR ELECTRIC ROOM (R) TVSS PANEL MS 208V 225A PANEL PDS 208V 225A PANEL PD 208V 225A PANEL MS 208V 225A 16 MARKET SQUARE PREP KITCHEN 11 14 PANEL PF 208V 225A PANEL CR 208V 125A W/TVSS F.E. OFFICE 15 (E) PANEL P 480V 125A PANEL EQUIP (E) PANEL G 208V 100A PANEL EQUIP 6 (E)(E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) PANEL PB 225A PANEL BAKERY (E) (E) (E)(E) (E) COMPRESSOR RACK B COMPRESSOR RACK A 79 LIGHTING INVERTER INV 5 DEFROST LOADS 8 (E) 6 (E) GROUND FLOOR 12 17 2 3 3 6 5 (E) 7 (E) 611 10 8 11 6 8 8 12 13 16 5 (R) TVSS 6 PANEL PA 208V 225A 11 THIS RISER DIAGRAM DOES NOT SHOW ACTUAL PHYSICAL ARRANGEMENT OF EQUIPMENT. SEE FLOOR PLANS FOR EQUIPMENT LAYOUTS. THE FOLLOWING SWITCHGEAR SHALL BE SUPPLIED BY HILL PHOENIX: - POWERBOARDS HSB, PA, PB, PD, PDS, MS, CR AND PF - EXTERIOR DISCONNECT - 4 POLE, NORMALLY CLOSED "EMR" CONTACTOR WITH ENCLOSURE FOR QUOTATION, CONTACT KRISTY PITCHFORD AT HILL PHOENIX TELEPHONE: 770-285-3218 SWITCHGEAR NATIONAL ACCOUNT 1 #3/0 GROUNDING ELECTRODE CONDUCTOR IN 3/4"C. TO CONCRETE FOUNDATION REINFORCING STEEL. BUILDING STEEL FRAMING, AND METAL WATER MAIN; AND #6 GROUNDING ELECTRODE CONDUCTOR IN 1/2"C. TO DRIVEN GROUND RODS. 2 #4/0 GROUND TO BUILDING STEEL. 3 RELOCATED TRANSFORMER AND LSB PANEL. 4 EXISTING POWER COMPANY TRANSFORMER WITH BUILT IN METERING TO REMAIN. 5 120/208 VOLT LIGHTING INVERTER WITH FOUR 20 AMP OUTPUT BREAKERS TO BE PROVIDED BY TFM WITH LIGHTING PACKAGE. SEE SPECIFICATION IN LIGHT FIXTURE SCHEDULE ON E101, DETAIL 5/E113 AND ASSOCIATED PANEL SCHEDULE "INV" ON SHEET E112 FOR ADDITIONAL INFORMATION. 6 RELOCATED TRANSIENT VOLTAGE SURGE SUPPRESSOR. CONTRACTOR SHALL INSPECT AND SERVICE THE UNIT AND REPLACE IT WITH EQUIVALENT IF IT IS FOUND TO BE UNUSABLE. 7 INSTALL JUNCTION BOX OR PULL BOX AS REQUIRED TO EXTEND EXISTING FEEDER TO LOCATION OF RELOCATED PANEL LSB. 8 INSTALL JUNCTION BOX OR PULL BOX AS REQUIRED TO EXTEND EXISTING FEEDER TO LOCATION OF REPLACEMENT PANEL HSB. KEY NOTES SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ELECTRICAL RISER E-110 BSD DSP LOAD CALCULATIONS - Panel LSB Demand Derated Load Description KW Factor %KW Type Amps LIGHTING General 33.0 100 33.0 C 91.7 GENERAL Outlets (First 10 KW)10.0 100 10.0 NC 27.8 Outlets (Remainder)13.0 50 6.5 NC 105.3 Equipment (Misc)29.6 100 29.6 NC 82.2 Defrost Panel 24.8 100 24.8 NC 68.6 KITCHEN EQUIPMENT Kitchen Equip.260.3 65 169.2 NC 470.0 Total kW ............................370.7 Total Derated kW kW AMPS CONTINUOUS LOAD.......................................33.0 x 125 percent.........................41.3 114.6 TOTAL NON CONTINUOUS............................240.1 666.9 REQUIRED FEEDER.......................................281.3 781.5 (Next higher standard size.......................................800 amps) Existing 208V, 3 phase, 4 wire 800 amp panel and breaker are adequate. NOTES 1) Commercial kitchen equipment which has a thermostatic control or is used intermittently, has a feeder demand factor of 65% per NEC 220.56 ABBREVIATIONS kW = Kilowatts C = Continuous NC = NonContinuous 12/08/2021 02/07/22 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ELECTRICAL SCHEDULES E-111 BSD DSP PANEL SCHEDULE HSB 480 Volt, 3 Phase, 4 Wire, 1200 Amp, MLO Main Distribution Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 TVSS 3 100 (1) (1) 0 200 0.1 2 Compressor Rack A 3 70 (1) (1) 24 19900 6.6 (1) 0 0.1 (1) 24 6.6 (1) 0 0.1 (1) 24 6.6 3 (R) Panel LSB 3 350 (1) (1) (2) 370725 131.4 4 Compressor Rack B 3 150 (1) (1) 78 64500 21.5 (via 300 kVA transformer T1) (1) (2) 122.5 (1) 78 21.5 (1) (2)124.7 (1) 78 21.5 5 (E) Panel H 3 100 (1) (1) 77 63984 21.3 6 (E) Panel P 3 125 (1) (1) 56 46898 15.6 (1) 77 21.3 (1) 56 15.6 (1) 77 21.3 (1) 56 15.6 7 (E) Panel LA 3 (1) (1) 1 900 0.0 8 Space 3 0 0.0 (1) 1 0.6 (100 Amp Frame) 0 0.0 (1) 1 0.3 0 0.0 9 Space 3 0 0.0 10 Space 3 0 0.0 (200 Amp Frame) 0 0.0 (100 Amp Frame) 0 0.0 0 0.0 0 0.0 11 Space 3 0 0.0 12 Panel SC & CR 3 25 (1) (1) 11 8908 3.4 (200 Amp Frame) 0 0.0 (via 15 kVA transformer T2) (1) 11 2.2 0 0.0 (1) 11 3.4 152.7 144.5 146.4 47.1 45.9 47.1 Total KW Phase A......................................................... 199.9 Total Connected kW.......................................... 576 Total KW Phase B......................................................... 190.4 Total Connected Amps............................................... 694 Total KW Phase C......................................................... 193.6 Minimum Service Size.................................................. 867 AMPS NOTES: (1) See Electrical Riser for Wire and Conduit Size. (2) See load calculations on E110. PANEL SCHEDULE LSB (Panel previously referred to as Panel MDP2) Relocated 208 Volt, 3 Phase, 4 Wire, 800 Amp, Distribution Panel with 800 Amp MCB and Surge Suppressor, 100,000 AIC. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 Panel PD 3 (E)150 (1) (1) 81 29110 10.8 2 Panel PDS 3 (E)200 (1) (1) (3) 88692 30.0 (1) 81 9.3 (1) (3)28.6 (1) 81 9.0 (1) (3)24.6 7 (E) Panel LB 3 (E)150 (1) (1) 87 31204 9.3 8 Panel PA 3 (E)150 (1) (1) 108 38695 16.0 (1) 87 8.6 (1) 108 17.4 (1) 87 13.3 (1) 108 18.6 13 (E) TVSS 3 (E)100 (1) (1) 0 0.0 14 (E) Panel R2 3 (E)100 (1) (1) 9 3134 1.2 (1) 0 0.0 (1) 9 1.4 (1) 0 0.0 (1) 9 0.6 19 Panel PB 3 (E)100 (1) (1) 25 9124 3.3 20 SPARE 3 (E)100 0 0.0 (1) 25 3.4 0 0.0 (1) 25 2.4 0 0.0 25 (E) Panel R1 3 (E)60 (1) (1) 47 17003 7.8 26 (E) Panel G 3 (E)100 (1) (1) 35 12694 6.0 (1) 47 5.8 (1) 35 3.6 (1) 47 3.5 (1) 35 3.2 31 (2) Panel MS 3 225 (1) (1) 184 66225 22.0 32 SPARE 3 (E)40 0 0.0 (1) 184 19.6 0 0.0 (1) 184 24.6 0 0.0 37 (2) Defrost Panel 3 70 (1) (1) 69 24840 8.3 38 Space 3 0 0.0 (1) 69 8.3 0 0.0 (1) 69 8.3 0 0.0 43 (2,4) Dishwasher 3 175 #2/0 2" 139 50004 16.7 44 Space 3 0 0.0 #2/0 139 16.7 0 0.0 #2/0 139 16.7 0 0.0 78.1 71.6 77.8 53.2 50.9 47.0 Total KW Phase A......................................................... 131.4 Total Connected kW.......................................... 371 Total KW Phase B......................................................... 122.5 Total KW Phase C......................................................... 124.7 Refer to Load Calculations On E110. NOTES: Panel is being relocated within the electric room to allow for NEC working clearances, extend existing circuits noted in schedule to new panel location. (1) See Electrical Riser for Wire and Conduit Size. (2) Provide a new breaker as indicated, match existing fault current ratings. (3) See panel schedule for minimum service size. (4) Provide a Handle Padlock Device to lock breaker in Off position for servicing. Ltg Control Zones PANEL SCHEDULE LB (Sect 1) Ltg Control ZonesExisting to Remain 208 Volt, 3 Phase, 4 Wire, 36 Pole, 250 Amp MLO Smart Breaker Secondary Panel, Series Rated at 65K AIC. # Description P A W Cond FLA Watts KwA KwB KwC # Description P A W Cond FLA Watts KwA KwB KwC Power Link G3 Processor C2 1 Lighting - Vestibule 1 (E)15 #12 3/4" 1 108 0.1 2 Lighting - Floral 1 (E)15 #12 3/4" 2 296 0.3 C2 3 Lighting - RR Vestibule 1 (E)15 #12 3/4" 1 108 0.1 4 Lighting M - Bulk 1 (E)15 #12 3/4" 1 75 0.1 B1 5 Track Ltg - Checkout 1 (E)15 #12 3/4" 12 1440 1.4 6 Lighting - Grocery 1 (E)15 #12 3/4" 4 490 0.5 B1 7 Track Ltg - Checkout 1 (E)15 #12 3/4" 12 1440 1.4 8 Lighting - Grocery 1 (E)15 #12 3/4" 4 490 0.5 B1 9 Lighting - Wine 1 (E)15 #12 3/4" 4 432 0.4 10 Track Ltg - Bulk 1 (E)15 #12 3/4" 12 1440 1.4 B1 11 Track Ltg - Wine 1 (E)15 #12 3/4" 12 1440 1.4 12 Track Ltg - M/S Isle 1 (E)15 #12 3/4" 12 1440 1.4 C2 13 Lighting - Deli Canopy 1 (E)15 #12 3/4" 3 352 0.4 14 Track Ltg - Cold Isle 1 (E)15 #12 3/4" 12 1440 1.4 C2 15 Lighting - Deli 1 (E)15 #12 3/4" 3 408 0.4 16 (2) Lighting - Bakery Canopy 1 20 #12 3/4" 1 176 0.2 C2 17 Lighting - Deli 1 (E)15 #12 3/4" 3 408 0.4 18 (2) Lighting - M/S Isle 1 20 #12 3/4" 4 459 0.5 19 SPARE 2 (E)30 0 0.0 20 (1,3) FE/Toilets 1 20 #12 3/4" 3 357 0.4 A 21 0 0.0 22 (2) Lighting-M/S Produce Prep1 20 #12 3/4" 4 504 0.5 C1 23 Track Ltg - Sales (Deli) 1 (E)15 #12 3/4" 12 1440 1.4 24 (2,3) Lighting-Bakery Serv Isle 1 20 #12 3/4" 3 408 0.4 25 (2) Lighting - Coolers 1 20 #12 3/4" 5 574 0.6 26 (2) Lighting - Scully 1 20 #12 3/4" 4 492 0.5 OS 27 (2) Building Mounted Sign-Entry1 20 #12 3/4" 10 1200 1.2 28 (2) Recepts- Wine/Beer Display1 20 #12 3/4" 8 900 0.9 OS 29 (2) Building Mounted Sign-Entry1 20 #12 3/4" 10 1200 1.2 30 (E) Destratification Fans 1 (E)15 ETR ETR 2 180 0.2 31 Space 1 0 0.0 32 (E) Destratification Fans 1 (E)15 ETR ETR 2 180 0.2 33 (1,3) Emerg. Lighting Inverter 2 30 #10 3/4" 6 1322 0.6 34 (E) Destratification Fans 1 (E)15 ETR ETR 1 120 0.1 #10 6 0.7 36 (E) Destratification Fans 1 (E)15 ETR ETR 1 120 0.1 2.5 2.7 6.7 3.3 3.2 3.1 Total KW Phase A.........................................................9.3 Total Connected kW.......................................... 31 Total KW Phase B.........................................................8.6 Total Connected Amps..................................... 87 Total KW Phase C.........................................................13.3 Minimum Service Size....................................... 108 AMPS NOTES: (1) Provide a new standard breaker as indicated, match existing fault current ratings. (2) Provide a new smart breaker as indicated, match existing fault current ratings. (3) Provide Circuit Breaker Handle Padlock Attachment for Locking Breaker in the 'ON" Position. Ltg Control Zones PANEL SCHEDULE LA Ltg Control Zones #Description P A W Cond FLA Watts KwA KwB KwC # Description P A W Cond FLA Watts KwA KwB KwC 1 1 SPARE 1 (E)15 0 0.0 2 SPARE 1 (E)15 0 0.0 1 2 3 SPARE 1 (E)15 0 0.0 4 SPARE 1 (E)15 0 0.0 2 1 5 SPARE 1 (E)15 0 0.0 6 SPARE 1 (E)15 0 0.0 1 2 7 SPARE 1 (E)15 0 0.0 8 SPARE 1 (E)15 0 0.0 2 1 9 SPARE 1 (E)15 0 0.0 10 SPARE 1 (E)15 0 0.0 1 2 11 SPARE 1 (E)15 0 0.0 12 Space 1 0 0.0 2 1 13 Space 1 0 0.0 14 Space 1 0 0.0 1 2 15 Space 1 0 0.0 16 Rear Wall Packs 1 (E)20 ETR ETR 2 600 0.6 2 1 17 Space 1 0 0.0 18 Rear Wall Packs - Receiving 1 (E)20 ETR ETR 1 300 0.3 1 2 19 Space 1 0 0.0 20 Space 1 0 0.0 2 1 21 SPARE 1 (E)15 0 0.0 22 Space 1 0 0.0 2 23 SPARE 1 (1)15 0 0.0 24 Space 1 0 0.0 1 25 SPARE 1 (1)15 0 0.0 26 Space 1 0 0.0 1 2 27 SPARE 1 (1)15 0 0.0 28 Space 1 0 0.0 29 Space 1 0 0.0 30 Space 1 0 0.0 0.0 0.0 0.0 0.0 0.6 0.3 Total KW Phase A.........................................................0.0 Total Connected kW.......................................... 1 Total KW Phase B.........................................................0.6 Total Connected Amps..................................... 1 Total KW Phase C.........................................................0.3 Minimum Service Size....................................... 1 AMPS NOTES: (1) ExistIng standard breaker installed in smart panel. HC- Handle Blocking Device to Prevent Inadvertant Shutoff. PANEL SCHEDULE H Existing to Remain 480 Volt, 3 Phase, 4 Wire, 42 Pole, 125 Amp MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 (E) RTU-2 3 (E)45 ETR ETR 25 20775 6.9 2 EF-1 3 (E)15 #12 3/4" 4 3407 1.1 ETR 25 6.9 #12 4 1.1 ETR 25 6.9 #12 4 1.1 7 (E) RTU-3 3 (E)45 ETR ETR 25 20775 6.9 8 (1,2) Hood Supply Fan MUA-13 15 #12 3/4" 1 914 0.3 ETR 25 6.9 #12 1 0.3 ETR 25 6.9 #12 1 0.3 13 RTU-4 3 (E)15 #12 3/4" 3 2900 1.0 14 (1) MUA1 - Cond 1 3 15 #12 3/4" 6 5152 1.7 #12 3 1.0 #12 6 1.7 #12 3 1.0 #12 6 1.7 19 (1) RTU-5 3 15 #12 3/4" 3 2900 1.0 20 (1,2) Hood Exhaust Fan EF-1 3 15 #12 3/4" 3 2161 0.7 #12 3 1.0 #12 3 0.7 #12 3 1.0 #12 3 0.7 25 (1) RTU-6 3 15 #12 3/4" 6 5000 1.7 26 Space 1 0 0.0 #12 6 1.7 28 Space 1 0 0.0 #12 6 1.7 30 Space 1 0 0.0 17.5 17.5 17.5 3.9 3.9 3.9 Total KW Phase A.........................................................21.3 Total Connected kW.......................................... 64 Total KW Phase B.........................................................21.3 Total Connected Amps............................................... 77 Total KW Phase C.........................................................21.3 Minimum Service Size.................................................. 96 AMPS NOTES: (1) Provide a new breaker as indicated, match existing fault current ratings. (2) Connect Through Controller in Deli Hood Control Panel. PANEL SCHEDULE P Existing to Remain 480 Volt, 3 Phase, 4 Wire, 42 Pole, 225 Amp MLO Panel, 18,000 AIC. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 SPARE 1 (E)15 0 0.0 2 SPARE 3 (E)15 0 0.0 3 SPARE 1 (E)15 0 0.0 0 0.0 5 SPARE 1 (E)15 0 0.0 0 0.0 7 SPARE 1 (E)15 0 0.0 8 Condenser - Rack A 3 (E)15 #12 3/4" 7 5983 2.0 9 (E) Loading Dock Lift 3 (E)15 ETR ETR 8 6316 2.1 #12 7 2.0 ETR 8 2.1 #12 7 2.0 ETR 8 2.1 14 SPARE 3 (E)50 0 0.0 15 (1) Baler 3 40 #8 3/4" 20 16650 5.6 0 0.0 #8 20 5.6 0 0.0 #8 20 5.6 20 (1) Condenser - Rack B 3 25 #10 3/4" 22 17950 6.0 21 Space 1 0 0.0 #10 22 6.0 23 Space 1 0 0.0 #10 22 6.0 25 Space 1 0 0.0 26 SPARE 3 (E)35 0 0.0 27 Space 1 0 0.0 0 0.0 29 SPARE 1 (E)15 0 0.0 0 0.0 7.7 7.7 7.7 8.0 8.0 8.0 Total KW Phase A.........................................................15.6 Total Connected kW.......................................... 47 Total KW Phase B.........................................................15.6 Total Connected Amps............................................... 57 Total KW Phase C.........................................................15.6 Minimum Service Size.................................................. 71 AMPS NOTES: (1) Provide a new breaker as indicated, match existing fault current ratings. Ltg Control Zones PANEL SCHEDULE LB (Sect 2) Ltg Control ZonesExisting to Remain 208 Volt, 3 Phase, 4 Wire, 42 Pole, 250 Amp MLO Smart Breaker Secondary Panel, Series Rated at 65K AIC. #Description P A W Cond FLA Watts KwA KwB KwC # Description P A W Cond FLA Watts KwA KwB KwC B2 37 B25-Beer/Wine Case Lts 1 (E)15 #12 3/4" 2 240 0.2 38 B14-Sushi/Cheese Case Lts 1 (E)15 #12 3/4" 1 156 0.2 B2 39 A8-Ice Cream Case Lts 1 (E)15 #12 3/4" 2 264 0.3 40 B33-Produce Case Lts 1 (E)15 #12 3/4" 3 360 0.4 B2 B2 41 A9-Ice Cream Case Lts 1 (E)15 #12 3/4" 1 168 0.2 42 A5-Seafood Case Lts 1 (E)15 #12 3/4" 1 60 0.1 B2 B2 43 B26-Dairy Case Lts 1 (E)15 #12 3/4" 2 180 0.2 44 B10-Meal Solutions Case Lts 1 (E)15 #12 3/4" 3 300 0.3 B2 B2 45 B5-Dairy Case Lts 1 (E)15 #12 3/4" 3 360 0.4 46 B12-Produce Case Lts 1 (E)15 #12 3/4" 3 360 0.4 B2 B2 47 B8-Dairy Case Lts 1 (E)15 #12 3/4" 3 312 0.3 48 B13-Produce Case Lts 1 (E)15 #12 3/4" 3 360 0.4 B2 B2 49 A7-Bakery Case Lts 1 (E)15 #12 3/4" 0 48 0.0 50 Space 1 0 0.0 B2 51 B30-Bakery Case Lts 1 (E)15 #12 3/4" 0 36 0.0 52 Space 1 0 0.0 B2 53 B11-Bakery Case Lts 1 (E)15 #12 3/4" 1 168 0.2 54 Space 1 0 0.0 B2 55 (1) A6-Ice Cream Case Lts 1 20 #12 3/4" 0 48 0.0 56 Space 1 0 0.0 B2 57 (1) B29-Beer/Pasta Case Lts 1 20 #12 3/4" 2 180 0.2 58 Space 1 0 0.0 B2 59 (1) B28-Beverage Case Lts 1 20 #12 3/4" 2 228 0.2 60 Space 1 0 0.0 B2 61 (1) B27-Deli Case Lts 1 20 #12 3/4" 4 528 0.5 62 Space 1 0 0.0 B2 63 (1) B31-Meat Case Lts 1 20 #12 3/4" 2 180 0.2 64 Space 1 0 0.0 B2 65 SPARE 1 20 0 0.0 66 Space 1 0 0.0 B2 67 (1) B6-Meat/Seafood Case Lts1 20 #12 3/4" 1 72 0.1 68 (1) HW Recirc. Pump 1 20 #12 3/4" 2 200 0.2 RP B2 69 (1) B7-Meat/Seafood Case Lts1 20 #12 3/4" 1 60 0.1 70 B35-Produce Island Lts 1 (E)15 #12 3/4" 2 240 0.2 B2 71 (2) Track Ltg - Produce 1 20 #12 3/4" 12 1440 1.4 72 B36-Produce Island Lts 1 (E)15 #12 3/4" 1 120 0.1 B2 73 (2) Lighting - Stock Room 1 20 #12 3/4" 15 1746 1.7 74 B32-Seafood Case Lts 1 (E)15 #12 3/4" 1 60 0.1 B2 75 (1,2) Lighting - RR, BR, Well 1 20 #12 3/4" 3 363 0.4 76 B34-Produce Island Lts 1 (E)15 #12 3/4" 2 240 0.2 B2 77 (2) Lighting - Mezz 1 20 #12 3/4" 3 388 0.4 78 B37- Beer/Wine Case Lts 1 (E)15 #12 3/4" 3 300 0.3 B2 2.9 1.4 2.7 0.7 1.2 0.8 Total KW Phase A.........................................................3.6 Total Connected kW.......................................... 10 Total KW Phase B.........................................................2.6 Total Connected Amps..................................... 27 Total KW Phase C.........................................................3.5 Minimum Service Size....................................... 34 AMPS NOTES: (1) Provide a new smart breaker as indicated, match existing fault current ratings. (2) Provide Circuit Breaker Handle Padlock Attachment for Locking Breaker in the 'ON" Position. PANEL SCHEDULE R1 Existing to Remain 208 Volt, 3 Phase, 4 Wire, 42 Pole, 100 Amp MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 B25- Beer/Wine Case Fans 1 (E)15 #12 3/4" 1 120 0.1 2 B16-Salad Case Fans 1 (E)15 #12 3/4" 4 456 0.5 3 A8-Ice Cream Fans 1 (E)15 #12 3/4" 4 449 0.4 4 B33-Produce Case Fans 1 (E)15 #12 3/4" 2 216 0.2 5 A9-Ice Cream Fans 1 (E)15 #12 3/4" 2 264 0.3 6 A5-Seafood Case Fans 1 20 #12 3/4" 1 150 0.2 7 B26-Dairy Case Fans 1 (E)15 #12 3/4" 1 96 0.1 8 B10-Meal Solutions Case Fans1 (E)15 #12 3/4" 2 180 0.2 9 B5-Dairy Case Fans 1 (E)15 #12 3/4" 4 456 0.5 10 B12-Produce Case Fans 1 (E)15 #12 3/4" 4 456 0.5 11 B8-Dairy Case Fans 1 (E)15 #12 3/4" 2 180 0.2 12 B13-Produce Case Fans 1 (E)15 #12 3/4" 4 456 0.5 13 A7-Bakery Case Fans 1 (E)15 #12 3/4" 1 100 0.1 14 B35-Produce Island Fans 1 (E)15 #12 3/4" 8 960 1.0 15 B30-Bakery Case Fans 1 (E)15 #12 3/4" 0 24 0.0 16 B36-Produce Island Fans 1 (E)15 #12 3/4" 4 480 0.5 17 B11-Bakery Case Fans/AS 1 (E)15 #12 3/4" 2 276 0.3 18 B32-Seafood Case Fans 1 (E)15 #12 3/4" 0 36 0.0 19 A6-Ice Cream Case Fans 1 (E)15 #12 3/4" 1 100 0.1 20 B34-Produce Island Fans 1 (E)15 #12 3/4" 8 960 1.0 21 (2) B29-Beer/ Pasta Case Fans1 20 #12 3/4" 1 156 0.2 22 B21-Floral Cooler 1 (R)15 #12 3/4" 1 96 0.1 23 (2) B28-Beverage Case Fans 1 20 #12 3/4" 1 84 0.1 24 (2) B17-Deli Case Fans /AS 1 20 #12 3/4" 1 144 0.1 25 (2) B27-Deli Case Fans 1 20 #12 3/4" 2 192 0.2 26 (2) A8- Ice Cream AS 1 20 #12 3/4" 15 1819 1.8 27 (2) B31-Meat Case Fans 1 20 #12 3/4" 1 96 0.1 28 A9- Ice Cream AS 1 (E)15 #12 3/4" 9 1116 1.1 29 (2) B37-Beer/Wine Case Fans 1 20 #12 3/4" 1 156 0.2 30 A6- Ice Cream AS 1 (E)15 #12 3/4" 2 185 0.2 31 (2) B6-Meat/Seafood Case Fans1 20 #12 3/4" 4 480 0.5 32 B2-Dairy Cooler 1 (E)15 #12 3/4" 3 324 0.3 33 (2) B7-Meat/Seafood Case Fans1 20 #12 3/4" 4 480 0.5 34 B20-Bulk Cooler 1 (E)15 #12 3/4" 1 108 0.1 35 (2) B9-Seafood Ice Table 1 20 #12 3/4" 1 108 0.1 36 B3-Bakery Cooler 1 (E)15 #12 3/4" 2 216 0.2 37 (1,2) B4- Drain Line Heat Trace1 20 #12 3/4" 8 1000 1.0 38 (1,2) A1-Drain Line Heat Trace1 20 #12 3/4" 8 1000 1.0 39 (2) B14-Sushi/Cheese Fans/AS1 20 #12 3/4" 5 624 0.6 40 (1,2) A2-Drain Line Heat Trace1 20 #12 3/4" 8 1000 1.0 41 (2) B15-Deli Case Fans 1 20 #12 3/4" 2 204 0.2 42 (1,2) A3-Drain Line Heat Trace1 20 #12 3/4" 8 1000 1.0 2.1 2.3 1.3 5.7 3.5 2.2 Total KW Phase A.........................................................7.8 Total Connected kW.......................................... 17 Total KW Phase B.........................................................5.8 Total Connected Amps..................................... 47 Total KW Phase C.........................................................3.5 Minimum Service Size....................................... 59 AMPS NOTES: (1) Provide a GFCI Type Circuit Breaker with 30 milliamp trip for equipment protection. (2) Provide a new breaker as indicated, match existing fault current ratings. PANEL SCHEDULE R2 Existing to Remain 208 Volt, 3 Phase, 4 Wire, 42 Pole, 100 Amp MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 B22-Cold Cooked Cooler 1 (E)15 #12 3/4" 2 204 0.2 2 SPARE 1 (E)15 0 0.0 3 B24-Produce Prep 1 (E)15 #12 3/4" 2 204 0.2 4 SPARE 1 (E)15 0 0.0 5 Space 1 0 0.0 6 SPARE 1 (E)15 0 0.0 7 B19-Produce Cooler 1 (E)15 #12 3/4" 2 204 0.2 8 Space 1 0 0.0 9 B23-Meat/Seafood Prep 1 (E)15 #12 3/4" 3 408 0.4 10 Space 1 0 0.0 11 A5- Seafood AS 1 (E)15 #12 3/4" 3 419 0.4 12 Space 1 0 0.0 13 A7- Bakery AS 1 (E)15 #12 3/4" 2 185 0.2 14 SPARE 2 (E)15 0 0.0 15 SPARE 1 (E)15 0 0.0 0 0.0 17 SPARE 1 (E)15 0 0.0 18 SPARE 2 (E)15 0 0.0 19 Space 1 0 0.0 0 0.0 21 Space 1 0 0.0 22 SPARE 2 (E)15 0 0.0 23 SPARE 1 (E)15 0 0.0 0 0.0 25 Space 1 0 0.0 26 SPARE 2 (E)15 0 0.0 27 Space 1 0 0.0 0 0.0 29 B1-Meat/Seafood Cooler 2 (E)15 #12 3/4" 1 270 0.1 30 SPARE 2 (E)15 0 0.0 #12 1 0.1 0 0.0 33 Space 1 0 0.0 34 (E) Motor Room Recepts 1 (E)20 ETR ETR 5 540 0.5 35 Space 1 0 0.0 36 Space 1 0 0.0 37 (1) Fire Alarm Control Panel 1 (E)20 #12 3/4" 4 500 0.5 38 Space 1 0 0.0 39 Refrig. Leak Detection System1 (E)20 #12 3/4" 2 200 0.2 40 SPARE 1 (E)15 0 0.0 41 SPARE 1 (E)15 0 0.0 42 Space 1 0 0.0 1.2 0.8 0.6 0.0 0.5 0.0 Total KW Phase A.........................................................1.2 Total Connected kW.......................................... 3 Total KW Phase B.........................................................1.4 Total Connected Amps..................................... 9 Total KW Phase C.........................................................0.6 Minimum Service Size....................................... 11 AMPS NOTES: (1) Provide a Handle Blocking Device to hold breaker in On position. PANEL SCHEDULE SC (Panel previously referred to as Panel S) Existing to Remain 208 Volt, 3 Phase, 4 Wire, 42 Pole, 125 Amp MLO Panel with Isolated Ground Bar and Surge Suppressor, 10,000 AIC. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 IT Rack 1 (E)20 #12 3/4" 8 1000 1.0 2 SPARE 1 (E)20 0 0.0 3 SPARE 1 (E)20 0 0.0 4 SPARE 1 (E)20 0 0.0 5 SPARE 1 (E)20 0 0.0 6 SPARE 1 (E)20 0 0.0 7 SPARE 1 (E)20 0 0.0 8 SPARE 1 (E)20 0 0.0 9 SPARE 1 (E)20 0 0.0 10 SPARE 1 (E)20 0 0.0 11 SPARE 1 (E)20 0 0.0 12 Space 1 0 0.0 13 SPARE 1 (E)20 0 0.0 14 SPARE 1 (E)20 0 0.0 15 SPARE 1 (E)20 0 0.0 16 SPARE 1 (E)20 0 0.0 17 SPARE 1 (E)20 0 0.0 18 (1,2) Recept POS/Printers 1 20 #12 3/4" 1 84 0.1 19 SPARE 1 (E)20 0 0.0 20 (1,2) Scale Rec - Mobile Bulk 1 20 #12 3/4" 1 84 0.1 21 SPARE 1 (E)20 0 0.0 22 Market Square Patch Panels 1 20 #12 3/4" 2 200 0.2 23 SPARE 1 (E)20 0 0.0 24 (1,2) Deli Menu Boards 1 20 #12 3/4" 8 1000 1.0 25 (1,2) Scale Rec - CCook Prep 1 20 #12 3/4" 1 84 0.1 26 (1,2) Deli Menu Boards 1 20 #12 3/4" 7 800 0.8 27 (1) Scale Recept - Bakery 1 20 #12 3/4" 1 168 0.2 28 (1) Scale Rec - Mobile Meat Cut1 20 #12 3/4" 1 84 0.1 29 (1) Scale Rec - Meat Aisle 1 20 #12 3/4" 2 252 0.3 30 Space 1 0 0.0 31 (1) Scale Rec - SF Aisle 1 20 #12 3/4" 1 168 0.2 32 (E) TVSS 3 (E)30 ETR ETR 0.3 100 0.0 33 1 0 0.0 ETR 0.3 0.0 35 (1) Scale Recept - Deli 1 20 #12 3/4" 4 420 0.4 ETR 0.3 0.0 37 1 20 #12 3/4" 0 0.0 38 Panel CR 3 (E)40 #8 1" 12 4180 1.2 39 (1) Scale Recept - Prod. Prep 1 20 #12 3/4" 1 84 0.1 #8 12 1.6 41 Space 1 2 200 0.2 #8 12 1.4 1.3 0.3 0.9 2.1 1.9 2.5 Total KW Phase A.........................................................3.4 Total Connected kW.......................................... 9 Total KW Phase B.........................................................2.2 Total Connected Amps..................................... 25 Total KW Phase C.........................................................3.4 Minimum Service Size....................................... 31 AMPS NOTES: Provide Isolated Ground Conductor for All Branch Circuits. Shared Neutral Conductors shall not be Permitted. (1) Breaker shall be GFCI. (2) Provide new breaker compatible with existing panel and matching the existing AIC rating. PANEL SCHEDULE MS 208 Volt, 3 Phase, 4 Wire, 72 Pole, 225 Amp MLO Panel. 22k AIC. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 Heated Shelf Food Warmer 1 20 #12 3/4" 9 1090 1.1 2 (1) Mkt Square Monitors 1 20 #12 3/4" 3 350 0.4 3 Heated Shelf Food Warmer 1 20 #12 3/4" 9 1090 1.1 4 (1) Soup Kettle 1 20 #12 3/4" 7 800 0.8 5 Heated Shelf Food Warmer 1 20 #12 3/4" 9 1090 1.1 6 (1) Soup Kettle 1 20 #12 3/4" 7 800 0.8 7 (1) Warming Drawer 1 20 #12 3/4" 13 1600 1.6 8 Hot Food Wells 1 20 #12 3/4" 8 1000 1.0 9 (1) CVAP Holding Cabinet 1 20 #12 3/4" 19 2292 2.3 10 Hot Food Wells 1 20 #12 3/4" 8 1000 1.0 11 (1) CVAP Holding Cabinet 1 20 #12 3/4" 19 2292 2.3 12 (1) Warming Drawer 1 20 #12 3/4" 13 1600 1.6 13 (1) CVAP Holding Cabinet 1 20 #12 3/4" 19 2292 2.3 14 Conv. Recepts 1 20 #12 3/4" 3 360 0.4 15 (1) Heat Lamps 1 20 #12 3/4" 9 1125 1.1 16 (1) Turbo Chef Oven 2 30 #10 3/4" 30 6200 3.1 17 (1) Heat Lamps 1 20 #12 3/4" 13 1500 1.5 #10 30 3.1 19 Conv. Recepts 1 20 #12 3/4" 5 540 0.5 20 Conv. Recepts 1 20 #12 3/4" 3 360 0.4 21 1 20 #12 3/4" 0 0.0 22 Wrap Station 1 20 #12 3/4" 7 780 0.8 23 (1) Panini Rapid Cook Oven 2 30 #10 3/4" 29 6000 3.0 24 Slicer 1 20 #12 3/4" 4 420 0.4 #10 29 3.0 26 Slicer 1 20 #12 3/4" 4 420 0.4 27 (1) UC Refrigerator 1 20 #12 3/4" 2 180 0.2 28 Conv. Recepts 1 20 #12 3/4" 3 360 0.4 29 (1) Back Bar Cooler 1 20 #12 3/4" 3 400 0.4 30 (1) Finishing Oven 2 20 #12 3/4" 14 2808 1.4 31 (1) Back Bar Cooler 1 20 #12 3/4" 3 400 0.4 #12 14 1.4 33 Conv. Recept - Util Rm 1 20 #12 3/4" 2 180 0.2 34 Juicer 1 20 #12 3/4" 3 300 0.3 35 (1) Panini Rapid Cook Oven 2 30 #10 3/4" 30 6200 3.1 36 (1) UC Refrigerator 1 20 #12 3/4" 3 400 0.4 #10 30 3.1 38 Wine Serving System 1 20 #12 3/4" 1 100 0.1 39 Deli Case Mounted Recepts 1 20 #12 3/4" 3 360 0.4 40 Iced Tea Brewer 1 20 #12 3/4" 14 1700 1.7 41 Deli Case Mounted Recepts 1 20 #12 3/4" 3 360 0.4 42 (1) UC Refrigerator 1 20 #12 3/4" 2 180 0.2 43 (1) UC Refrigerator 1 20 #12 3/4" 2 180 0.2 44 (1) Blender 1 20 #12 3/4" 15 1800 1.8 45 SPARE 1 20 0 0.0 46 (1) Blender 1 20 #12 3/4" 15 1800 1.8 47 SPARE 1 20 0 0.0 48 Deli Corner Recept 1 20 #12 3/4" 2 180 0.2 49 SPARE 1 20 0 0.0 50 Deli Corner Recept 1 20 #12 3/4" 2 180 0.2 51 SPARE 1 20 0 0.0 52 Deli Corner Recept 1 20 #12 3/4" 2 180 0.2 53 SPARE 1 20 0 0.0 54 Deli Corner Recept 1 20 #12 3/4" 2 180 0.2 55 Space 1 0 0.0 56 Countertop Steamer 1 20 #12 3/4" 15 1800 1.8 57 Space 1 0 0.0 58 (1) Rice Cooker 2 20 #12 3/4" 7 1456 0.7 59 Space 1 0 0.0 #12 7 0.7 61 Space 1 0 0.0 62 Rice Cooker 2 20 #12 3/4" 7 1456 0.7 63 Space 1 0 0.0 #12 7 0.7 65 Ondo Food Locker 2 20 #10 3/4" 12 2500 1.3 66 (1) CVAP Holding Cabinet 1 20 #12 3/4" 19 2292 2.3 #10 12 1.3 68 Space 1 0 0.0 69 Conv. Recepts 1 20 #12 3/4" 5 640 0.6 70 (1) CVAP Mobile Hold Cabinet 1 20 #12 3/4" 19 2292 2.3 71 Conv. Recepts 1 20 #12 3/4" 3 360 0.4 72 Space 1 0 0.0 13.5 5.9 13.4 8.5 13.8 11.3 Total KW Phase A.........................................................22.0 Total Connected kW.......................................... 66 Total KW Phase B.........................................................19.6 Loads Derated per NEC 220.56 Total KW Phase C.........................................................24.6 Minimum Service Size....................................... 120 AMPS NOTES: (1) Breaker shall be GFCI. (2) Provide a Handle Padlock Device to lock breaker in Off position for servicing. PANEL SCHEDULE G Existing to Remain 208 Volt, 3 Phase, 4 Wire, 42 Pole, 100 Amp MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 GWH-1 Controls 1 (E)20 #12 3/4" 5 600 0.6 2 Air Door AD-1 1 (E)20 #12 3/4" 13 1500 1.5 3 GWH-1 Controls 1 (E)20 #12 3/4" 5 600 0.6 4 Air Door AD-2 1 (E)20 #12 3/4" 3 320 0.3 5 SPARE 1 (E)20 0 0.0 6 Air Door AD-3 1 (E)20 #12 3/4" 3 320 0.3 7 SPARE 1 (E)20 0 0.0 8 Recepts - Bug Lights 1 (E)20 #12 3/4" 2 192 0.2 9 SPARE 1 (E)20 0 0.0 10 Receptacle Dock Light 1 (E)15 #12 3/4" 5 540 0.5 11 SPARE 1 (E)20 0 0.0 12 Receiving Doorbell 1 (E)15 #12 3/4" 2 200 0.2 13 SPARE 1 (E)20 0 0.0 14 Recept - Deodorizer 1 (E)15 #12 3/4" 2 250 0.3 15 SPARE 1 (E)20 0 0.0 16 Reverse Osmosis Machine 1 (E)15 #12 3/4" 3 360 0.4 17 SPARE 1 (E)20 0 0.0 18 SPARE 1 (E)15 0 0.0 19 SPARE 1 (E)20 0 0.0 20 SPARE 1 (E)15 0 0.0 21 SPARE 1 (E)20 0 0.0 22 SPARE 1 (E)20 0 0.0 23 SPARE 1 (E)20 0 0.0 24 (E)RH-1 1 (E)20 ETR ETR 5 600 0.6 25 (2) Defrost Panel Control Power2 15 #12 3/4" 6 1200 0.6 26 (E) Dok-Lock System 1 (E)20 ETR ETR 8 1000 1.0 #12 6 0.6 28 SPARE 1 (E)20 0 0.0 29 (2) Ice Flaker 2 15 #12 3/4" 7 1400 0.7 30 Space 1 0 0.0 #12 7 0.7 32 (E) Roof Recepts 1 (E)20 ETR ETR 5 540 0.5 33 Space 1 0 0.0 34 (E) Roof Recepts 1 (E)20 ETR ETR 5 540 0.5 35 (2) Rack A Control Power 2 15 #12 3/4" 6 1200 0.6 36 Employee RR - EF-7 1 (E)15 #12 3/4" 1 132 0.1 #12 6 0.6 38 SPARE 1 (E)15 0 0.0 39 (2) Rack B Control Power 2 15 #12 3/4" 6 1200 0.6 40 SPARE 1 (E)15 0 0.0 #12 6 0.6 42 SPARE 1 (E)15 0 0.0 2.5 1.8 1.9 3.5 1.8 1.3 Total KW Phase A.........................................................6.0 Total Connected kW.......................................... 13 Total KW Phase B.........................................................3.6 Total Connected Amps..................................... 35 Total KW Phase C.........................................................3.2 Minimum Service Size....................................... 44 AMPS NOTES: (1) Breaker shall be GFCI. (2) Provide a new breaker as indicated, match existing fault current ratings. (3) Provide a Handle Padlock Device to lock breaker in Off position for servicing. 12/08/2021 02/07/22 HILL PHOENIX TO DETERMINE NUMBER OF LIGHTING CONTACTORS REQUIRED BASE ON PANELBOARD SCHEDULES. 1. 20A, 4-POLE, NORMALLY CLOSED, ELECTRICALLY HELD LIGHTING CONTACTOR WITH 120V COIL AND 600V LINE CONTACTS MOUNTED IN POWERPLUS UNIT. QUANTITY OF CONTACTORS REQUIRED FOR EACH ZONE SHALL BE DETERMINED BASED ON THE PANELBOARD SCHEDULES RATHER THAN FROM THIS DIAGRAM. 2. RELAY CONTACTS ON CPC CONTROL BOARD INSIDE POWERPLUS UNIT. 3. ALL WIRING SHALL COMPLY WITH THE 2011 NEC. 4. ALL PRE-WIRED EQUIPMENT MUST BE LISTED AND LABELED PER NEC 110.3 (A AND B). 5. FLASH PROTECTION WARNING LABELS ON SWITCHBOARDS AND PANELBOARDS SHALL BE INSTALLED PER NEC 110.16. 6. SPACES ABOUT ELEC EQUIPMENT SHALL MEET NEC 110.26 (A-F). 7. CONDUCTORS INSTALLED IN UNDERGROUND RACEWAYS MUST BE RATED FOR WET LOCATIONS. 8. ALL CABLE OR RACEWAY WIRING INSTALLED IN EXPOSED OR CONCEALED LOCATIONS UNDER METAL CORRUGATED SHEET ROOF DECKING SHALL BE INSTALLED AND SUPPORTED PER NEC 300.4. 9. CONTACTOR TO BE SHIPPED LOOSE ALONG WITH AN ENCLOSURE. SEE DETAIL 5, NOTE 1 ON SHEET E113 FOR MORE INFORMATION. RUN #10 GROUND FROM "INV" TO CONTACTOR ENCLOSURE. NOTES - 1/E112 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ELECTRICAL SCHEDULES E-112 BSD DSP PANEL SCHEDULE PF 208 Volt, 3 Phase, 4 Wire, 72 Pole, 225 Amp, Flush Mount, MLO Panel, Rated at 10,000 AIC. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 (1,2) Men's Hand Dryer 1 20 #12 3/4" 13 1500 1.5 2 Recept - F.E Office 1 20 3 360 0.4 3 (1,2) Women's Hand Dryer 1 20 #12 3/4" 13 1500 1.5 4 Recept - F.E Office 1 20 3 360 0.4 5 (1) Electric Water Cooler 1 20 #12 3/4" 6 700 0.7 6 Recept - F.E Office 1 20 3 360 0.4 7 Coffee Grinder 1 15 #10 1" 9 1100 1.1 8 Recept - F.E Office 1 20 3 360 0.4 9 Coffee Grinder 1 15 #10 1" 9 1100 1.1 10 Recept - F.E Office Comp. Cart 1 20 3 360 0.4 11 (2) Floral Sink Instahot 2 30 #10 1" 22 4576 2.3 12 Floor Rec. - Utility Table 1 20 5 540 0.5 #10 22 2.3 14 Recept Bagged Ice Freezer 1 20 #12 3/4" 10 1200 1.2 15 Recepts- Floral 1 20 #12 1" 3 360 0.4 16 Auto Door Operator 1 20 #12 3/4" 7 800 0.8 17 Recepts- Floral 1 20 #12 1" 3 360 0.4 18 Auto Door Operator 1 20 #12 3/4" 7 800 0.8 19 Instacart Heat & Hold 1 20 #12 1" 16 1920 1.9 20 Auto Door Operator 1 20 #12 3/4" 7 800 0.8 21 Instacart True T49 Refrigerator 1 20 #12 1" 10 1200 1.2 22 Registers 1 and 2 Belts 1 20 #12 1" 3 400 0.4 23 Instacart True T23 Freezer 1 20 #12 1" 10 1200 1.2 24 Registers 3 and 4 Belts 1 20 #12 1" 3 400 0.4 25 Nut Grinder 2 15 #10 1" 10 2080 1.0 26 Registers 5 and 6 Belts 1 20 #12 1" 3 400 0.4 #10 10 1.0 28 Recept- Powered Wheel Chair 1 20 #12 3/4" 2 180 0.2 29 Nut Grinder 2 15 #10 1" 10 2080 1.0 30 Recept - Outdoor/Vest Bug Lt 1 20 #12 3/4" 2 276 0.3 #10 10 1.0 32 Recept - Outdoor/Window Disp 1 20 6 720 0.7 33 Nut Grinder 2 15 #10 1" 10 2080 1.0 34 (2) Men's Sink Instahot 2 20 #10 3/4" 22 4576 2.3 #10 10 1.0 #10 22 2.3 37 Nut Grinder 2 15 #10 1" 10 2080 1.0 38 (2) Women's Sink Instahot 2 30 #10 3/4" 22 4576 2.3 #10 10 1.0 #10 22 2.3 41 Coffee Brewer 2 20 #10 1" 14 2900 1.5 42 Front End Microwave 1 20 #12 1" 10 1200 1.2 #10 14 1.5 44 Floor Recept - Checkout 1 20 #10 1" 2 180 0.2 45 Coffee Brewer 2 20 #10 1" 14 2900 1.5 46 Floor Recept - Checkout 1 20 #10 1" 2 180 0.2 #10 14 1.5 48 Floor Recept - Checkout 1 20 #10 1" 2 180 0.2 49 6' Berry Produce Case 2 20 #10 1" 15 3180 1.6 50 Floor Recept - Seasonal Wine 1 20 #10 1" 2 180 0.2 #10 15 1.6 52 Floor Recept - Seasonal Bulk 1 20 #10 1" 2 180 0.2 53 6' Berry Produce Case 2 20 #10 1" 15 3180 1.6 54 Floor Recept - Seasonal Beer 1 20 #10 1" 2 180 0.2 #10 15 1.6 56 Column Recepts - Produce 1 20 #12 1" 2 180 0.2 57 SPARE 1 20 0 0.0 58 Column Recepts - Gondolas 1 20 #12 1" 2 180 0.2 59 SPARE 1 20 0 0.0 60 Recept - Refrig WIFI 1 20 #12 3/4" 1 100 0.1 61 SPARE 1 20 0 0.0 62 SPARE 1 20 0 0.0 63 SPARE 1 20 0 0.0 64 SPARE 1 20 0 0.0 65 SPARE 1 20 0 0.0 66 Recept- Coffee Conv 1 20 #12 1" 2 180 0.2 67 SPARE 1 20 0 0.0 68 Roof Recepts 1 20 #12 ` 3 360 0.4 69 SPARE 1 20 0 0.0 70 DS-1/FC-1 2 15 #12 3/4" 5 1000 0.5 71 Drink Case Condensate Pan 1 15 13 1500 1.5 #12 5 0.5 14.6 10.3 12.6 7.0 7.7 7.0 Total KW Phase A.........................................................21.6 Total Connected kW.......................................... 59 Total KW Phase B.........................................................18.0 Total Connected Amps..................................... 165 Total KW Phase C.........................................................19.6 Minimum Service Size....................................... 206 AMPS NOTES: (1) Breaker shall be GFCI for personel protection. (2) Handle Pad Lock device to lock breaker in Off position for servicing. PANEL SCHEDULE CR 208 Volt, 3 Phase, 4 Wire, 30 Pole, 125 Amp, Flush Mount MLO Panel with Additional Isolated Ground Bar and with Integral TVSS. Rated at 10,000 AIC #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 IG Recept - Cashier 1 20 #12 1" 3 400 0.4 2 Space 1 0 0.0 3 IG Recept - Cashier 1 20 #12 1" 3 400 0.4 4 Space 1 0 0.0 5 IG Recept - Cashier 1 20 #12 1" 3 400 0.4 6 Space 1 0 0.0 7 IG Recept - Cashier 1 20 #12 1" 3 400 0.4 8 Space 1 0 0.0 9 IG Recept - Cashier 1 20 #12 1" 3 400 0.4 10 Space 1 0 0.0 11 IG Recept - Cashier 1 20 #12 1" 3 400 0.4 12 Space 1 0 0.0 13 SPARE 1 20 0 0.0 14 Space 1 0 0.0 15 IG Recept - F.E Office Comp Crt 1 20 #12 3/4" 3 400 0.4 16 Space 1 0 0.0 17 IG Recept - FE Office I.E.I Panel 1 20 #12 3/4" 3 400 0.4 18 Space 1 0 0.0 19 IG Recept - Order Kiosk 1 20 #12 1" 3 400 0.4 20 Space 1 0 0.0 21 IG Recept - Instacart Cashier 1 20 #12 3/4" 3 400 0.4 22 Space 1 0 0.0 23 GF-IG Recept Coffee Scale 1 20 2 180 0.2 24 Space 1 0 0.0 25 Space 1 20 0 0.0 26 TVSS 3 15 0 0.0 27 Space 1 20 0 0.0 0 0.0 29 Space 1 20 0 0.0 0 0.0 1.2 1.6 1.4 0.0 0.0 0.0 Total KW Phase A.........................................................1.2 Total Connected kW.......................................... 4 Total KW Phase B.........................................................1.6 Total Connected Amps..................................... 12 Total KW Phase C.........................................................1.4 Minimum Service Size....................................... 15 AMPS NOTES: Provide Isolated Ground Conductor for All Branch Circuits. Shared Neutral Conductors shall not be Permitted. (1) Provide new breaker compatible with existing panel and matching the existing AIC rating. PANEL SCHEDULE PB 208 Volt, 3 Phase, 4 Wire, 42 Pole, 100 Amp MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 (2) Double Wide Proof Box 3 20 #12 3/4" 4 1584 0.5 2 Recept. - Bread Slicer 1 20 #12 3/4" 6 760 0.8 #12 4 0.5 4 Recept. - Bakery Microwave 1 20 #12 3/4" 13 1500 1.5 #12 4 0.5 6 Recept. - 20 QT Mixer 1 20 #12 3/4" 12 1400 1.4 7 (2) Double Rack Oven Blower 3 20 #12 3/4" 4 1500 0.5 8 Recepts - Bakery Prep 1 20 #12 3/4" 5 540 0.5 #12 4 0.5 10 Recept - Food Processor 1 20 #12 3/4" 7 840 0.8 #12 4 0.5 12 1 20 0 0.0 13 Rack Oven Controls 1 20 #12 3/4" 8 1000 1.0 14 1 20 0 0.0 15 1 0 0.0 16 1 20 0 0.0 17 1 0 0.0 18 1 20 0 0.0 19 Space 1 0 0.0 20 1 0 0.0 21 Space 1 0 0.0 22 1 20 0 0.0 23 1 0 0.0 24 1 20 0 0.0 25 Space 1 0 0.0 26 1 20 0 0.0 27 Space 1 0 0.0 28 1 20 0 0.0 29 Space 1 0 0.0 30 1 20 0 0.0 31 Space 1 0 0.0 32 Space 1 0 0.0 33 0 0.0 34 Space 1 0 0.0 35 0 0.0 36 Space 1 0 0.0 37 Space 1 0 0.0 38 Space 1 0 0.0 39 Space 1 0 0.0 40 Space 1 0 0.0 41 Space 1 0 0.0 42 Space 1 0 0.0 2.0 1.0 1.0 1.3 2.3 1.4 Total KW Phase A.........................................................3.3 Total Connected kW.......................................... 9 Total KW Phase B.........................................................3.4 Total Connected Amps..................................... 25 Total KW Phase C.........................................................2.4 Minimum Service Size....................................... 32 AMPS NOTES: (1) Breaker shall be GFCI for personel protection. (2) Provide a Handle Pad Lock device to lock breaker in Off position for servicing. (3) Provide a Handle Blocking Device to Prevent Inadvertant Shutoff. PANEL SCHEDULE PD 208 Volt, 3 Phase, 4 Wire, 42 Pole, 225 Amp, Flush Mount, MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 (1) Pizza Prep Table - Kitchen 1 20 #12 3/4" 5 560 0.6 2 Deli Hood Ltg 1 20 #10 3/4" 8 1000 1.0 3 Recepts - Kitchen Conv. 1 20 #12 3/4" 5 540 0.5 4 Deli Hood Controls 1 20 #12 3/4" 3 400 0.4 5 Recept - CCP Prep Slicer 1 20 #12 3/4" 4 420 0.4 6 Shunt Trip Power 1 20 #12 3/4" 4 500 0.5 7 Recep. - CCP Pizza Wrap 1 20 #10 3/4" 10 1150 1.2 8 (2) Blast Chiller 3 30 #10 3/4" 19 6700 2.2 9 (1) UC Refrig. CCP Prep (T48) 1 20 #12 3/4" 3 360 0.4 #10 19 2.2 11 Food Processor - CCP Cheese 1 20 #12 3/4" 4 420 0.4 #10 19 2.2 13 Food Processor - CCP 1 20 #12 3/4" 7 840 0.8 14 Hood CPC Board Power 1 20 #12 3/4" 1 100 0.1 15 Food Processor - CCP Dicer 1 20 #12 3/4" 7 840 0.8 16 SPARE 1 20 0 0.0 17 (1) UC Refrig CCP Prep (T48) 1 20 #12 3/4" 3 360 0.4 18 SPARE 1 20 0 0.0 19 (1) Pizza Prep Table - CCP 1 20 #12 3/4" 5 560 0.6 20 SPARE 1 20 0 0.0 21 Recept - CCP Conv. 1 20 #12 3/4" 2 180 0.2 22 SPARE 1 20 0 0.0 23 Recept - Veggie Noodler PP 1 20 #12 3/4" 4 500 0.5 24 SPARE 1 20 0 0.0 25 Recept - Produce Prep 1 20 #12 3/4" 3 360 0.4 26 SPARE 1 20 0 0.0 27 Recept - Overwrap Machine PP 1 20 #12 3/4" 7 780 0.8 28 SPARE 1 20 0 0.0 29 Rec - Dept Mgr's Desk/Bug Lt 1 20 0 0.0 30 Space 1 0 0.0 31 SPARE 1 20 0 0.0 32 Space 1 0 0.0 33 SPARE 1 20 0 0.0 34 Space 1 0 0.0 35 Space 1 0 0.0 36 Space 1 0 0.0 37 SF Steamer 3 50 #6 1" 33 12000 4.0 38 Space 1 0 0.0 #6 33 4.0 40 Roof Recepts 1 20 0 0.0 #6 33 4.0 42 Roof Recepts 1 20 #12 3/4" 5 540 0.5 7.5 6.7 5.7 3.3 2.6 3.3 Total KW Phase A.........................................................10.8 Total Connected kW.......................................... 29 Total KW Phase B.........................................................9.3 Total Connected Amps..................................... 81 Total KW Phase C.........................................................9.0 Minimum Service Size....................................... 101 AMPS NOTES: (1) Provide a GFCI Breaker. (2) Provide a Handle Pad Lock device to lock breaker in Off position for servicing. (3) Provide a Handle Blocking Device to hold breaker in On position. Ltg Control Zones LIGHTING INVERTER INV Ltg Control Zones120/208 Volt, 1 Phase, 3 Wire, 2.7 KVA Lighting Inverter with 4 output breakers #Description P A W Cond FLA Watts KwB KwC # Description P A W Cond FLA Watts KwB KwC EMR 1 (1) SPARE 1 20 #12 3/4" 0 0.0 2 (1) Stocking Emergency Lts 1 20 #12 3/4" 5 582 0.6 C2 EMR 3 (1) Grocery Emergency Lts 1 20 #12 3/4" 2 255 0.3 4 (1) Produce Emergency Lts 1 20 #12 3/4" 4 485 0.5 C2 0.0 0.3 0.6 0.5 Total KW Phase B.........................................................0.6 Total Connected Kw.......................................... 1.3 Total KW Phase C.........................................................0.7 Total Connected Amps..................................... 4 Minimum Service Size....................................... 5 AMPS NOTES: (1) See Detail 10/E113 All circuits fed from the lighting inverter shall be field wired through a normally closed lighting contactor mounted above the lighting inverter. See detail 5/E13. Contractor shall ensure that load is balanced on the two phases of the inverter as much as possible. Maximum amperage per phase shall be 11.2 amps. PANEL SCHEDULE PDS 208 Volt, 3 Phase, 4 Wire, 42 Pole, 225 Amp, Flush Mount, MLO Panel. #Description P A W Cond FLA Watts KwA KwB KwC #Description P A W Cond FLA Watts KwA KwB KwC 1 (Combi Shunt Trip Space) 1 0 0.0 2 (1,3)10 Pan Combi (C4T10) 3 60 #6 1-1/4" 50 18000 6.0 3 (1,3)10 Pan Combi (C4T10) 3 60 #6 1-1/4" 50 18000 6.0 #6 50 6.0 #6 50 6.0 #6 50 6.0 #6 50 6.0 8 (Combi Shunt Trip Space) 1 0 0.0 9 (Combi Shunt Trip Space) 1 20 #12 3/4" 0 0.0 10 (1) Electric Kettle 3 40 #8 3/4" 27 9800 3.3 11 (1,3) 6 Pan Combi (C4T6) 3 30 #8 3/4" 25 9000 3.0 #8 27 3.3 #8 25 3.0 #8 27 3.3 #8 25 3.0 16 (Kettle Shunt Trip Space) 1 20 #12 3/4" 0 0.0 17 (Fryer Shunt Trip Space) 1 20 0 0.0 18 (1) Rice Cooker 2 20 #10 3/4" 7 1456 0.7 19 (1) Pressure Fryer 3 50 #8 3/4" 38 13680 4.6 #10 7 0.7 #8 38 4.6 22 (Rice Cooker Shunt Trip Space) 1 0 0.0 #8 38 4.6 24 (1) Rice Cooker 2 20 #10 3/4" 7 1456 0.7 25 (Alto Sham Shunt Trip Space) 1 0 0.0 #10 7 0.7 27 (1) Alto Sham Oven 3 40 #8 3/4" 29 10600 3.5 28 (Rice Cooker Shunt Trip Space) 1 0 0.0 #8 29 3.5 30 Space 1 0 0.0 #8 29 3.5 32 Space 1 0 0.0 33 Blast Chiller 3 30 #10 3/4" 19 6700 2.2 34 Space 1 0 0.0 #10 19 2.2 36 Space 1 0 0.0 #10 19 2.2 38 Space 1 0 0.0 39 Space 1 0 0.0 40 Space 1 0 0.0 41 Space 1 0 0.0 42 Space 1 0 0.0 19.3 19.3 19.3 10.7 9.3 10.7 Total KW Phase A.........................................................30.0 Total Connected kW.......................................... 89 Total KW Phase B.........................................................28.6 Panel Derated per NEC 220 Total KW Phase C.........................................................30.0 Minimum Service Size....................................... 160 AMPS NOTES: (1) Breaker shall be shunt trip and be connected to the existing hood control panel so it trips upon activation of the fire suppression system. (2) Provide a GFCI Breaker. (3) Provide a Handle Pad Lock device to lock breaker in Off position for servicing. 12/08/2021 02/07/22 NOTES - 1/E113 NOTES - 10/E113 NOTES - 6/E113 NOTES - 7/E113 NOTES - 2/E113 NOTES -5/E113 NOTES - 9/E113 LIGHT MOUNTED INSIDE COOLER BOX CONNECT TO 120V POWER SOURCE FACTORY INSTALLED CONDUIT JUNCTION BOX MOUNTED ON TOP OF COOLER BOX PRESS SWITCH WITH PILOT LIGHT NOTE: SEE REFRIGERATION SPECIFICATIONS FOR CONDUIT SEALING REQUIREMENTS. WALL MOUNTED LIGHT IS FACTORY PROVIDED. AREA LIGHTING INSIDE COOLER IS PROVIDED BY TFM AND INSTALLED BY EC ELR 20A Emergency Lighting Inverter Utility Power Emergency Power Test Test Emergency Lighting Load SwitchlegNormal Panel 20A NormalLighting Load Local Control Device ɸ N ɸ N Normal Power Monitor SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ELECTRICAL DETAILS E-113 BSD DSP 12/08/2021 02/07/22 B22 SPARE OPEN SPARE OPEN SPARE B9 TC-2 OPEN SPARE B14 SPARE B1 CLIENT 1 B13 SPARE PA-10 PA-12 PA-14 PA-16 PA-18 18" AFF PS11 FAX B8 PRINTER PS14 302-BEO PHONE EMC OVERRIDE ALARM PANEL B11 CPC VOICE/DATA PULL BOX 4-11/16 X 4-11/16 JUNCTION BOX WALL MOUNT IT CABINET 84" AFF ROUGH IN 4 X 4 JUNCTION BOX MUZAK REC. (120V) (2) 3/4" MUZAK CONDUITS INDEPENDENT FROM VOICE/DATA PULL BOX AND BROUGHT TO AN ACCESSIBLE LOCATION ABOVE WALL OPEN SPARE B23 SPARE PULL BOX IN ACCESSIBLE LOCATION ABOVE BOH OFFICE 1" CONDUIT PA-20 MUZAK BOX KRONOS 54" AFF B2 TC-1 2" CONDUIT TO FEO 2" CONDUIT TO DEMARK 1" CONDUIT ELECTRICAL PANELS IT CLOSET PCPHONE SAFE ELECTRICALPANEL PF ELECTRICALPANEL CR CEILING F.E ELEVATION #1 FLOOR ELEC/DATA RACEWAY (LEGRAND AL5200 DUAL CHANNEL ALUMINUM RACEWAY - FINISH: BRUSHED ALUMINUM) SECTIONS JOINED WITH AN INTERNAL ELBOW PART AL5217 ALL FEEDS TO THE RACEWAY SHALL ENTER FROM BEHIND THROUGH A WALL BOX CONNECTOR PART AL521 F.E ELEVATION #2 F.E ELEVATION #4 PRINTER PAGING MICROPHONE 1 2 VOICE/DATA PULL BOX TOP AT 11' AFF 4-11/16 X 4-11/16 JUNCTION BOX 84" AFF (2) 1" CONDUITS WITH 4"X4" JBOX WITH DOUBLE GANG PLASTER RING FOR DATA LINES VOLUME CONTROLS FOR MUSIC JBOX FOR TEMP SENSOR. LOCATION TO BE COORDINATED WITH MECH. SONITROL JUNCTON BOX INSIDE OFFICE DOOR LATCH +48" AFF +60" AFF ISONAS KEY PAD BURGLAR SYSTEM (OUTSIDE OF OFFICE) PF-4 PAGING MICROPHONE PF-2 OPEN SPARE F14 TC-2 CR-15PS13PF-8 MODEM F14 SPARE PF-6 F.E ELEVATION #3 ELEC/DATA RACEWAY (LEGRAND AL5200 DUAL CHANNEL ALUMINUM RACEWAY - FINISH: BRUSHED ALUMINUM) SECTIONS JOINED WITH AN INTERNAL ELBOW PART AL5217 ALL FEEDS TO THE RACEWAY SHALL ENTER FROM BEHIND THROUGH A WALL BOX CONNECTOR PART AL521 1" CONDUIT 2" CONDUIT TO BEO 2" CONDUIT TO DEMARK F8 SPARE F9 SPARE F13 SPARE F12 TC-1 F15 SPARE OPEN SPARE OPEN SPARE 1" CONDUIT TO SEATING OPEN SPARE JUNCTION BOX FOR FUTURE SAFE MONITORING CONDUIT STUBBED TO 6" ABOVE CEILING 4-11/16" JUNCTION BOX WITH (1) 1" & (1) 3/4" CONDUIT STUBBED TO JUST ABOVE OFFICE CEILING FOR ISONAS PANEL 84" AFF IG CR-17 NOTE: ALL OPEN PORTS ARE TO BE WIRED BACK TO THE TFM PROVIDED PATCH PANEL (HUB) THESE DETAILS ARE FOR REFERENCE ONLY, SEE ARCH SHEETS FOR EXACT DIMENSIONS SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ELECTRICAL DETAILS E-114 BSD DSP ELEC/DATA RACEWAY (LEGRAND AL5200 DUAL CHANNEL ALUMINUM RACEWAY - FINISH: BRUSHED ALUMINUM) 12/08/2021 02/07/22 4 5 4.4 Z Y 1 FACP1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y B/CDOUBLECOMBI12GC/OSUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTY SALADSORDER F R R H R N H H H H R H 20' CHEESEDISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSSMANNQ3.5- S S - 4 RR HUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) SC R E F'G B E RR Y B I NSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12 HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANNIM - 05- E N 4 - R HONHC1872ATLANTIC FOOD BARSHHDD5136-TFM HILL PHOENIXSSGC-SSC-8 HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D48x18x60 L48x18x60 L48x18x60 L24x18x60 LWRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR L H U S SM A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R.MEN'S R.R. INSTACART ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLE BAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RLHUSSMANN RL 4DR RLHUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC ME A L S O L U T I O N S(WALK AROUND)HUSSMANNIM-04-E5-RHUSSMANNIM-04-C6-RH U S S M A N N I M - 0 4 - C 6 - R H U S S M A N N I M - 0 4-C 6 - R H U S S M A N N I M - 0 4 - C 6 - R HUSSMANQ4BV 10' RLHUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCL U D E S 4'PRODUCE DRINKS6'REFRIGERATEDWINE W/ WINEHOLDER20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK CA S ES 12' DRIN K S HILL PHOENIXON5DM-NRG-12HI L L PHOE N I X ON5DM-NRG-8HILL PHOENIXO N 5 D M-N RG-8HILL PHOENIXON5 D M- N R G -12 PASTASAUCE/SOUPS6 15CD 15CD 115CD 115CD 115CD 115CD 115CD115CD 15CD 15CD 75CD 75CD F F 30CD ANN 1 M 3 M M F 15CD 75CD 115CD 15CD 15CD 15CD F 75CD F F 75CD 75CD 30CD 30CD 30CD 30CD 30CD R R 5 5 SUPPLY SHUTDOWN RETURN SHUTDOWN R R5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN R R5 5 RETURN SHUTDOWNSUPPLY SHUTDOWN R R 5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN R R5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN R R5 5 RETURN SHUTDOWN SUPPLY SHUTDOWN FIRE ALARM CONTROL PANEL. FIRE ALARM SYSTEM ANNUNCIATOR. HORN/STROBE - MOUNT 80" AFF TO CENTER - CANDELA RATING AS NOTED. STROBE - MOUNT 80" AFF TO CENTER - CANDELA RATING AS NOTED. SMOKE DETECTOR DUCT SMOKE DETECTOR - FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR, MOUNTED BY MECHANICAL CONTRACTOR. CEILING PENDANT MOUNTED HORN/STROBE, CANDELA RATING AS NOTED. CEILING PENDANT MOUNTED STROBE, CANDELA RATING AS NOTED. TEMPERATURE (HEAT) DETECTOR. SPRINKLER ALARM BELL. SPRINKLER VALVE TAMPER SWITCH. SPRINKLER FLOW SWITCH. FIRE ALARM MONITOR MODULE. FIRE ALARM CONTROL RELAY FIRE ALARM PULL STATION. R M F FIRE ALARM LEGEND FACP ANN 1. PROVIDE 200# NYLON PULLSTRING IN ALL EMPTY CONDUIT RACEWAYS. 2. PROVIDE PLASTIC BUSHINGS ON THE ENDS OF THE CONDUIT STUBS. 3. A COMPLETE FIRE ALARM SYSTEM FOR THE FRESH MARKET SHALL BE PROVIDED. 4. ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES AND ANY OTHER FIRE ALARM EQUIPMENT INCLUDING THE FIRE ALARM CONTROL PANEL SHALL BE U.L. APPROVED. 5. PENDANT MOUNTED NOTIFICATION APPLIANCES SHALL BE MOUNTED AT 14' AFF IN THE SALES AREA AND 9'-6" AFF IN REAR CORRIDOR AND RECEIVING AREAS. GENERAL NOTES KEY NOTES 1 PROPOSED LOCATION. COORDINATE FINAL LOCATION WITH THE FIRE CODE OFFICIAL & TFM. FACP SHALL BE FIRELITE OR SILENT KNIGHT. 2 FIRE ALARM MONITOR MODULE FOR HOOD FIRE SUPPRESSION SYSTEM. 3 COORDINATE LOCATION OF SPRINKLER SYSTEM FLOW AND TAMPER SWITCHES WITH SPRINKLER CONTRACTOR . 4 COORDINATE ANNUNCIATOR PANEL WITH AHJ AND TFM PROJECT MANAGER PRIOR TO ROUGH-IN. 5 DUCT SMOKE DETECTOR IN SUPPLY AND RETURN DUCTS, PROVIDED AND WIRED BY FIRE ALARM CONTRACTOR, INSTALLED IN DUCT BY MC. UPON ACTUATION, SMOKE DETECTOR SHALL SHUT DOWN THE HVAC UNIT AND SEND A SIGNAL TO THE BUILDING FIRE ALARM SYSTEM. REMOTE SIGNALING AND TEST/RESET STATION SHALL BE PROVIDED AND INSTALLED BY FIRE ALARM CONTRACTOR. TEST/REST STATION SHALL BE LOCATED IN AN ACCESSIBLE LOCATION, COORDINATE LOCATION WITH FIRE MARSHALL'S OFFICE PRIOR TO INSTALLATION. 6 FLOW SWITCHES AND TAMPER SWITCHES FOR SPRINKLER SYSTEM. VERIFY QUANTITIES AND LOCATIONS WITH SPRINKLER CONTRACTOR PRIOR TO INSTALLATION. PROVIDE MONITOR MODULES AS REQUIRED. 1. MONITOR MODULE FOR HOOD FIRE SUPPRESSION SYSTEM. 2. TYPICAL CONTROL RELAY AND DUCT DETECTOR FOR RTU FAN SHUTDOWN. 4. SPRINKLER FLOW AND TAMPER SWITCHES, REFER TO FIRE PROTECTION SHOP DRAWINGS FOR QUANTITIES AND LOCATIONS OF SPRINKLER FLOW AND TAMPER SWITCHES. 5. PROVIDE TWO TELEPHONE LINES FROM DACT TO TELEPHONE EQUIPMENT BACKBOARD FOR TERMINATION BY TELEPHONE SYSTEM INSTALLER. THE DACT SHALL BE PROGRAMMED TO CALL THE APPROVED CENTRAL STATION DESIGNATED BY TFM. M M SS 120V FACP EXTERIOR HORN STROBE IF REQUIRED BY AHJ. F SIGNALING LINE CIRCUIT, INSTALL 18G4C FPL WIRE NOTIFICATION APPLIANCE CIRCUITS, INSTALL 14G2C FPL WIRE SS REMOTE ANNUNCIATOR PANEL INSTALL 18G4C FPL WIRE M HS NOTE 1 15CD 15CD 75CD 75CD WP F F F M SS 15CD 15CD 15CD F F R R R R R R NOTE 3 NOTE 2 SSNOTE 4 F R RR R 15CD 15CD 15CD 30CD 30CD 30CD 30CD 30CD 75CD 75CD 75CD 115CD 115CD 115CD 75CD 75CD 75CD 75CD 115CD 115CD 115CD 115CD CONTROL UNIT ANNUNCIATOR ALARM NOTIFICATION FIRE SAFETY FUNCTIONS SUPPLEMENTARY ACTUATE ALARM SIGNAL ACTUATE TROUBLE SIGNAL ACTUATE SUPERVISORY SIGNAL ACTUATE GENERAL ALARM SHUTDOWN ROOF TOP UNITS ACTUATE REMOTE ANNUNCIATORS TRANSMIT ALARM SIGNAL TO SUPERVISINGSTATION . TRANSMIT TROUBLE SIGNAL TO SUPERVISINGSTATION TRANSMIT SUPERVISORY SIGNAL TOSUPERVISING STATION1 MANUAL STATION X X X X X 2 SMOKE DETECTOR - OTHER X X X X X 3 SPRINKLER SYSTEM WATERFLOW X X X X X 4 KITCHEN HOOD FIRE SUPPRSSSION RELEASE X X X X X 5 FIRE ALARM SYSTEM A/C POWER FAILURE X X X 6 FIRE ALARM SYSTEM LOW BATTERY X X X 7 OPEN CIRCUIT X X X 8 GROUND FAULT X X X 9 NOTIFICATION APPLIANCE SHORT CIRCUIT X X X 10 SPRINKLER SYSTEM VAVLE TAMPER X X X 11 SMOKE DETECTOR - DUCT X X 12 BUILDING OCCUPANCY/LOAD USE GROUP: M/S - NON-SEPARATED MIX USE M-MERCANTILE (PRIMARY) B-BUSINESS (ACCESSORY) S1-STORAGE (ACCESSORY) F1-KITCHENS (ACCESSORY) TOTAL OCCUPANT LOAD: 605 TENANT AREA: 24,569 S.F. SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana FIRE ALARM PLAN E-116 BSD DSP 12/08/2021 02/07/22