Loading...
HomeMy WebLinkAboutRangeline (Carmel) IN - Energy ManagementSHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT SYSTEM OVERVIEW PLAN EM001 BSD NGS 1. THE BIDDING REFRIGERATION INSTALLATION CONTRACTORS, NOR THE GENERAL CONTRACTORS, SHALL PROVIDE ANY SUBCONTRACTOR WITH A PARTIAL SET OF DOCUMENTS. ALL GENERAL CONTRACTOR AND SUBCONTRACTORS TO BE PROVIDED WITH A COMPLETE SET OF CONSTRUCTION DOCUMENTS AND PROJECT SPECIFICATIONS THROUGHOUT THE BIDDING AND CONSTRUCTION PROCESSES OF THIS PROJECT. THERE ARE TO BE NO EXCEPTIONS TO THIS WITHOUT PRIOR APPROVAL BY THE FRESH MARKET PROJECT MANAGER. 2. THE REFRIGERATION INSTALLATION CONTRACTOR AND GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL COORDINATION BETWEEN ALL TRADES PRIOR TO COMMENCEMENT OF WORK AND THROUGHOUT THE PROJECT. 12/08/2021 02/07/22 FACP WF 4 54.4 Z Y 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y B/CDOUBLECOMBI12GC/OSUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTYSALADSORDER F R R H R N H H H H R H 20'CHEESEDISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSSMANNQ3.5-SS-4RRHUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12 HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANNIM-05-EN4-RHONHC1872ATLANTIC FOOD BARSHHDD5136-TFM HILL PHOENIXSSGC-SSC-8 HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D48x18x60 L48x18x60 L48x18x60 L24x18x60 LWRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR L H U S SM A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R. MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RLHUSSMANN RL 4DR RLHUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC ME A L S O L U T I O N S(WALK AROUND)HUSS MAN N IM-04-E5-RHUSSMANNI M - 0 4 - C 6- R H U S S M A N NIM-04-C6-RH U S S M A N NIM-04-C6-RH U S S M A N NIM-04-C6-RHUSSMANQ4BV 10' RL HUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCLUDES 4'PRODUCE DRINKS6' R E F R IG E R A T E DWIN E W / W I N EHOLDER 20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK CASES12' DRINKSHILL PHOENIXON5DM-NRG-12HILL PHOENIXON 5 DM-N RG-8 HILL PHOENIXON5DM-NRG-8HILL PH O EN IX ON5DM-NRG-12P A S T A S A U C E / S O UP S CHASE CHASE CHASE CHASE CHASE CHASE 2 2 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 ETR RTU-2 ETR RTU-1 ETR RTU-3S H S S S S S 4 5 7 6 8 1 0 1 0 8 S7 75 1 1 1 2 2 2 2 2 2 2 2 2 2 1 2 EMC OVERRIDE ALARM PANEL (SURFACE MOUNTED). MOUNT AT 60" A.F.F. TO BOTTOM OF PANEL. (4) BELDEN #5501F1 (2-#22c SHIELDED CABLE) TO CFP-8 FOR LIGHTING BYPASS S1 H H 4 1 1 1 2 3 4 6 5 1 4 1 7 1 1 1 LLSV 5 3 1 X X VS 1 5 DS SL 1 8 S 1 5 1 DO WF 1 8 5 1 3 9 9 OUTSIDE PHOTOCELL DEWPOINT SENSOR SPACE TEMPERATURE SENSOR OUTSIDE AIR AMBIENT TEMPERATURE SENSOR X EMS TEMPERATURE SENSOR REFRIGERATION CIRCUIT DESIGNATION EMS ELECTRIC DEFROST TERMINATION SENSOR EMS DOOR SWITCH X DS RETURN AIR TEMPERATURE SENSOR SL SUPPLY AIR TEMPERATURE SENSOR OVERHEAD WIRING IN CONDUIT BV HOT WATER TEMPERATURE SENSOR FLUID BALANCING VALVE STROBE LIGHT AND HORN UNDERGROUND WIRING IN CONDUIT LLSV CURRENT SENSOR LIQUID LINE SOLENOID VALVE S PUSH BUTTON SWITCHSUCTION TEMPERATURE SENSOR WATER FLOW SWITCHWF EVAPORATOR PRESSURE REGULATOR DRY CONTACT SUCTION PRESSURE SENSOR REFRIGERANT LEAK DETECTOR CPC MF168 OR 8RO BOARD LOCATED IN COMPRESSOR PANEL "A" AT COMPRESSOR RACK1 2 3 4 5 6 7 CPC MF168 I/O BOARD LOCATED IN RTU-1 CPC MF168 OR 8RO BOARD LOCATED IN COMPRESSOR PANEL "B" AT COMPRESSOR RACK 8 9 1 0 1 1 11 STROBE LIGHT AND HORN FOR REFRIGERANT LEAK ALARM. SEE DETAIL #11 ON SHEET RC104 FOR ADDITIONAL INFORMATION. 12 STROBE LIGHT AND HORN FOR REFRIGERANT LEAK ALARM. SEE DETAIL #8 ON SHEET RC104 FOR ADDITIONAL INFORMATION. 13 PROVIDE RS485 I/O NETWORK WIRING BETWEEN THE RACK COMPRESSOR PANEL, ROOFTOP CONDENSING UNIT PANELS, AND LIGHTING CONTROL PANEL AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 14 FACTORY INSTALLED TEMPERATURE SENSOR IS FACTORY WIRED TO ITS RESPECTIVE CASE CONTROLLER. 15 RTU UNIT WITH FACTORY INSTALLED I/O BOARD. PROVIDE RS485 I/O NETWORK WIRING BETWEEN RTU AND OTHER I/O BOARDS AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 16 (2) #16 AWG TO CPC 8RO BOARD IN POWERWALL UNIT FOR EMERGENCY LIGHTING CONTROL OF ZONE "EMR". 17 CONNECT TO COMM LOOP TO FACTORY INSTALLED CPC BOARDS. 18 MOUNT SUPPLY TEMP AT PLENUM PRIOR TO SPIRAL TRANSITION. 19 DELI HOOD CONTROL PANEL SHALL HAVE FIELD INSTALLED I/O BOARD, SEE DRAWING RC105 FOR ADDITIONAL DETAILS. PROVIDE RS485 I/O NETWORK WIRING BETWEEN HOOD CONTROL PANEL AND OTHER I/O BOARDS AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 20 PROVIDE RS485 I/O NETWORK WIRING BETWEEN THE CASES AND THE E2 CONTROLLER AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 21 CONNECT MOD BUS LOOP TO CASE CONTROLLERS. 1 FREEZER DOOR SWITCH N.C/WIRE TO BE CONNECTED TO DOOR SWITCH. CONTACT 'CLOSE' WHEN DOOR IS OPEN. 2 THE REFRIGERATION CONTRACTOR SHALL PROVIDE RS-485 I/O WIRING FROM I/O BOARD IN CONDENSER ELECTRICAL PANEL TO COMPRESSOR RACK CONTROL PANEL AND TO THE GLYCOL PUMP STATION AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 3 LIGHTING CONTACTOR CABINET. 4 TEMPERATURE SENSOR FOR HOT WATER HEAT RECLAIM INPUT AND OUTPUT. SEE SHEET P502. 5 DOOR SWITCH WITH BUILT-IN HORN/STROBE. SEE DETAIL 7 ON EM104 FOR MORE INFORMATION. 6 TEMPERATURE SENSOR FOR SELF-CONTAINED CASE FOR TEMPERATURE MONITORING ONLY INSTALLED BY REFRIGERATION CONTRACTOR AND WIRED BY REFRIGERATION CONTRACTOR. 7 RIC SHALL PROVIDE AND INSTALL LEAK DETECTION TUBING (SEE DETAIL 8 ON EM104) FROM RLDS UNIT SAMPLING PORT # TO THE INDICATED AREA PER DETAIL 8 ON EM103. TUBING SHALL ALSO BE INSTALLED FROM THE RLDS UNIT EXHAUST AND INTAKE PORTS UP THROUGH THE REFRIGERATION PIPING CHASE TO THE ROOF. INTAKE AND EXHAUST SHALL BE ADEQUATELY SEPARATED ON THE ROOF. 8 VERIFY LOCATION OF RTU AND SENSOR FOR RTU WITH MECHANICAL PLANS. 9 MECHANICAL UNIT SHALL HAVE FIELD INSTALLED I/O BOARD. PROVIDE RS485 I/O NETWORK WIRING BETWEEN RTU AND OTHER I/O BOARDS AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 10 REMOTE FACILITIES STATUS DISPLAY PANEL (FSD) WITH BUILT IN LIGHTING CONTROL PANEL (PUSHBUTTON OVERRIDES) LOCATED AT REAR MANAGER'S DESK. SEE DETAIL 4 ON E114 FOR ADDITIONAL INFORMATION. SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT TERMINATION PLAN - INPUTS EM101a BSD NGS 1. ALL NETWORK COMMUNICATION AND SENSOR WIRING SHALL BE INSTALLED IN CONDUIT RACEWAYS BETWEEN SPECIFIED LOCATIONS. ALL NETWORK COMMUNICATION AND SENSOR WIRING CONDUITS AND RACEWAYS WITH PULL STRINGS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL NETWORK COMMUNICATION AND SENSOR WIRING TO BE INSTALLED IN THESE CONDUITS SHALL BE FURNISHED AND INSTALLED BY THE REFRIGERATION INSTALLATION CONTRACTOR. ALL SENSOR AND DEVICE INSTALLATIONS AND ALL TERMINATIONS AND FINAL CONNECTIONS FOR NETWORK COMMUNICATION AND SENSOR WIRING SHALL BE BY THE REFRIGERATION INSTALLATION CONTRACTOR. 2. ALL TUBING FOR THE CPC IRLDS II REFRIGERANT LEAK DETECTION SYSTEM SHALL BE FURNISHED AND INSTALLED BY THE REFRIGERATION INSTALLATION CONTRACTOR SUPPORTED FROM THE SENSOR WIRING CONDUITS INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL DEVICE INSTALLATIONS AND FINAL CONNECTIONS FOR THE TUBING SHALL BE BY THE REFRIGERATION INSTALLATION CONTRACTOR. 3. COORDINATE ALL SPECIFIED OVERHEAD SENSOR WIRING CONDUITS TO THE REFRIGERATED FIXTURES TO DROP AT THE SAME DROP LOCATIONS AS THE REFRIGERANT PIPING. REFER TO THE REFRIGERATION PIPING PLANS FOR THE OVERHEAD DROP LOCATIONS. 4. INSTALL NETWORK COMMUNICATION WIRING IN CONDUITS SEPARATE FROM SENSOR AND POWER WIRING. 5. MULTIPLE CPC TEMPERATURE SENSOR CABLES ORIGINATING FROM DIFFERENT CASES HAVING THE SAME CIRCUIT IDENTIFICATION MAY BE RUN IN THE SAME CONDUIT TO THE SPECIFIED CONTROL BOARD. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE NECESSARY CONDUITS AND RACEWAYS WITH PULL STRING LOCATIONS WITH THE REFRIGERATION INSTALLATION CONTRACTOR. TYPICAL FOR ALL MULTI-CASE REFRIGERATION CIRCUITS. 6. REFER TO THE MECHANICAL (M) PLANS BY BRANDT ENGINEERING, INC. FOR MECHANICAL EQUIPMENT LOCATIONS. 7. REFER TO UNDERGROUND LOW VOLTAGE CONDUIT ROUTING (EU) PLANS BY BRANDT ENGINEERING, INC. FOR UNDERGROUND CONDUIT ROUTING. 8. EACH REFRIGERATED CASE/EVAPORATOR ON A SYSTEM SHALL BE IDENTIFIED WITH A UNIT LETTER (UPPERCASE) AND SYSTEM NUMBER WITH A SENSOR LETTER (LOWERCASE) AFTERWARDS THERE IS MORE THAN ONE CASE/EVAPORATOR ON A SYSTEM. ALL SENSOR LETTERS SHALL BE ASSIGNED STARTING WITH 'a' FROM LEFT TO RIGHT WHEN VIEWED FROM THE FRONT (SALES AREA SIDE) OF THE CASE/EVAPORATOR LINE UP. 12/08/2021 02/07/22 4 54.4 Z Y SL SL 9 FACP 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B C D E F G A Z Y B/CDOUBLECOMBI12GC/OSUSHI 12' CMS SALADS H H H H DELI CHEESE DISPLAY TC TC R CARVING HOT PICKUP 34" AFF SOUP MTO SALADS PREPARED SPECIALTYSALADS ORDER F R R H R N H H H H R H 20'CHEESEDISPLAY GREENSDISPLAYHUSSMANNQ3.5-SS-6RHUSSMANNQ3.5-SS-4RRHUSSMANNQ3.5-SS-90R 38x26x42UTILITY CART RR RR BAGGED ICE CHESTNESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET) NESTING TABLES (PLANT SET)SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BIN SC REF'G BERRY BINSC REF'G BERRY BINSC REF'G BERRY BINREF. NARROW IN-LINE CASE (SELF-SERVICE)DELLFRIOEFE-5052HILL PHOENIXSSGC-SSC-8 HILL PHOENIXSSGC-SSC-8HILL PHOENIXSSGC-SSC-12 HOBARTOV500G2-EE HOBARTPW2E-41 TRUET-49-HCTRUET-23F-HCINTERMETROC535-HFC-U-GYBACE, LLCV63-HDLP HONHC1872HONHC1872HONHC1872HUSSMANNIM-05-IN8-RHUSSMANNIM-05-EN4-RHONHC1872ATLANTIC FOOD BARSHHDD5136-TFM HILL PHOENIXSSGC-SSC-8 HONHC1872 HONHC1872 WRAPPING BOARD WRAPPING BOARDWRAPPING BOARD D D D D48x18x60 L48x18x60 L48x18x60 L24x18x60 LWRAPPING BOARD UP UP ID5SLID5SLID5SLID5SLR L H U S SM A N N R L 2 D RRLHUSSMANN RL5DRRLHUSSMANN RL5DRRLHUSSMANN RL3DRID5SLID5SLID5SLID5SLMEAT & SEAFOOD COOLER MEAT & SEAFOOD PREP OFFICE WOMEN'S R.R. MEN'S R.R. INSTACART CLOSET ENTRY/EXIT VESTIBULE FRONT END CHECKOUT AREA FLORAL SALES PRODUCE SALES MEAT SERVICE AISLEBAKERY SERVICE AISLE DAIRY SALES FROZEN SALES GROCERY SALES BEER AND WINE SALES BULK/COFFEE/CANDY SALES DELI PREP RECEIVING BOH CORRIDOOR FLORAL COOLER FLORAL PREP PRODUCE COOLER PRODUCE PREP KITCHEN COLD COOKED PREP COLD COOKED COOLER SCULLERY FIRE RISER BAKERY PREP BAKERY COOLER DAIRY COOLER BREAK ROOM RESTROOM RESTROOM WELLNESS ROOM BULK COOLER ICE CREAM FREEZER BAKERY DELI GROCERY FREEZER MEAT & SEAFOOD FREEZER ELECTRICAL ROOM RESTROOM COORIDOR RLHUSSMANN RL 4DR RLHUSSMANN RL 4DR HILL PHOENIXBSD-SW-10RC-SSC ME A L S O L U T I O N S(WALK AROUND)HU S SMAN N IM-04-E5-RHUSSMANNI M - 0 4 - C 6- R H U S S M A N NIM-04-C6-RH U S S M A N NIM-04-C6-RH U S S M A N NIM-04-C6-RHUSSMANQ4BV 10' RL HUSSMANN RL 2DR ID5SLR ID5SLR ID5SL 12' S.S. REF. DELI/MEAT CASE, 5-DK 3DRFROZENSF4' SF REF'G CASE,5DK12' PRODUCE VA(INCLUDES 4'PRODUCE DRINKS6' R E F R I G E R A T E DWIN E W / W I N EHOLDER 20' BEER MD (5DK)W/BEER HOLDER28' DELI / CHEESE5 DK CASES12' DRINKSHILL PHOENIXON5DM-NRG-12HILL PHOENIXON 5 D M-N RG-8 HILL PHOENIXON5DM-NRG-8HILL PH OENI X ON5DM-NRG-12P A S T A S A U C E / S O UP S CHASE CHASE CHASE CHASE CHASE CHASE LLSV LLSV LLSV LLSV LLSV LLSV LLSV LLSV SL SL SL SL SL SL SL SL SL SL SL SL SLSL 9 9 9 9 9 9 9 9 SL SL SL 9 1 1 1 2 2 2 2 2 LLSV LLSV LLSV LLSV LLSV 3 1 1 1 1 1 1 6 1 2 3 4 6 5 1 4 1 7 1 1 1 LLSV 5 31 X X VS 1 5 DS SL 1 8 S 1 5 1 DO WF 1 8 5 1 3 9 9 OUTSIDE PHOTOCELL DEWPOINT SENSOR SPACE TEMPERATURE SENSOR OUTSIDE AIR AMBIENT TEMPERATURE SENSOR X EMS TEMPERATURE SENSOR REFRIGERATION CIRCUIT DESIGNATION EMS ELECTRIC DEFROST TERMINATION SENSOR EMS DOOR SWITCH X DS RETURN AIR TEMPERATURE SENSOR SL SUPPLY AIR TEMPERATURE SENSOR OVERHEAD WIRING IN CONDUIT BV HOT WATER TEMPERATURE SENSOR FLUID BALANCING VALVE STROBE LIGHT AND HORN UNDERGROUND WIRING IN CONDUIT LLSV CURRENT SENSOR LIQUID LINE SOLENOID VALVE S PUSH BUTTON SWITCH SUCTION TEMPERATURE SENSOR WATER FLOW SWITCHWF EVAPORATOR PRESSURE REGULATOR DRY CONTACT SUCTION PRESSURE SENSOR REFRIGERANT LEAK DETECTOR CPC MF168 OR 8RO BOARD LOCATED IN COMPRESSOR PANEL "A" AT COMPRESSOR RACK1 2 3 4 5 6 7 CPC MF168 I/O BOARD LOCATED IN RTU-1 CPC MF168 OR 8RO BOARD LOCATED IN COMPRESSOR PANEL "B" AT COMPRESSOR RACK 8 9 1 0 1 1 11 STROBE LIGHT AND HORN FOR REFRIGERANT LEAK ALARM. SEE DETAIL #11 ON SHEET RC104 FOR ADDITIONAL INFORMATION. 12 STROBE LIGHT AND HORN FOR REFRIGERANT LEAK ALARM. SEE DETAIL #8 ON SHEET RC104 FOR ADDITIONAL INFORMATION. 13 PROVIDE RS485 I/O NETWORK WIRING BETWEEN THE RACK COMPRESSOR PANEL, ROOFTOP CONDENSING UNIT PANELS, AND LIGHTING CONTROL PANEL AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 14 FACTORY INSTALLED TEMPERATURE SENSOR IS FACTORY WIRED TO ITS RESPECTIVE CASE CONTROLLER. 15 RTU UNIT WITH FACTORY INSTALLED I/O BOARD. PROVIDE RS485 I/O NETWORK WIRING BETWEEN RTU AND OTHER I/O BOARDS AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 16 (2) #16 AWG TO CPC 8RO BOARD IN POWERWALL UNIT FOR EMERGENCY LIGHTING CONTROL OF ZONE "EMR". 17 CONNECT TO COMM LOOP TO FACTORY INSTALLED CPC BOARDS. 18 MOUNT SUPPLY TEMP AT PLENUM PRIOR TO SPIRAL TRANSITION. 19 DELI HOOD CONTROL PANEL SHALL HAVE FIELD INSTALLED I/O BOARD, SEE DRAWING RC105 FOR ADDITIONAL DETAILS. PROVIDE RS485 I/O NETWORK WIRING BETWEEN HOOD CONTROL PANEL AND OTHER I/O BOARDS AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 20 PROVIDE RS485 I/O NETWORK WIRING BETWEEN THE CASES AND THE E2 CONTROLLER AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 21 CONNECT MOD BUS LOOP TO CASE CONTROLLERS. 1 FREEZER DOOR SWITCH N.C/WIRE TO BE CONNECTED TO DOOR SWITCH. CONTACT 'CLOSE' WHEN DOOR IS OPEN. 2 THE REFRIGERATION CONTRACTOR SHALL PROVIDE RS-485 I/O WIRING FROM I/O BOARD IN CONDENSER ELECTRICAL PANEL TO COMPRESSOR RACK CONTROL PANEL AND TO THE GLYCOL PUMP STATION AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 3 LIGHTING CONTACTOR CABINET. 4 TEMPERATURE SENSOR FOR HOT WATER HEAT RECLAIM INPUT AND OUTPUT. SEE SHEET P502. 5 DOOR SWITCH WITH BUILT-IN HORN/STROBE. SEE DETAIL 7 ON EM104 FOR MORE INFORMATION. 6 TEMPERATURE SENSOR FOR SELF-CONTAINED CASE FOR TEMPERATURE MONITORING ONLY INSTALLED BY REFRIGERATION CONTRACTOR AND WIRED BY REFRIGERATION CONTRACTOR. 7 RIC SHALL PROVIDE AND INSTALL LEAK DETECTION TUBING (SEE DETAIL 8 ON EM104) FROM RLDS UNIT SAMPLING PORT # TO THE INDICATED AREA PER DETAIL 8 ON EM103. TUBING SHALL ALSO BE INSTALLED FROM THE RLDS UNIT EXHAUST AND INTAKE PORTS UP THROUGH THE REFRIGERATION PIPING CHASE TO THE ROOF. INTAKE AND EXHAUST SHALL BE ADEQUATELY SEPARATED ON THE ROOF. 8 VERIFY LOCATION OF RTU AND SENSOR FOR RTU WITH MECHANICAL PLANS. 9 MECHANICAL UNIT SHALL HAVE FIELD INSTALLED I/O BOARD. PROVIDE RS485 I/O NETWORK WIRING BETWEEN RTU AND OTHER I/O BOARDS AS SHOWN IN DETAIL #1 'EMS SYSTEM LAYOUT' ON DRAWING RC102. 10 REMOTE FACILITIES STATUS DISPLAY PANEL (FSD) WITH BUILT IN LIGHTING CONTROL PANEL (PUSHBUTTON OVERRIDES) LOCATED AT REAR MANAGER'S DESK. SEE DETAIL 4 ON E114 FOR ADDITIONAL INFORMATION. SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT TERMINAL PLAN - OUTPUTS EM101B BSD NGS 1. ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT RACEWAYS BETWEEN SPECIFIED LOCATIONS. ALL CONTROL WIRING CONDUITS AND RACEWAYS WITH PULL STRINGS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL CONTROL WIRING TO BE INSTALLED IN THESE CONDUITS SHALL BE FURNISHED AND INSTALLED BY THE REFRIGERATION INSTALLATION CONTRACTOR. ALL VALVE AND DEVICE INSTALLATIONS AND ALL TERMINATIONS AND FINAL CONNECTIONS FOR CONTROL WIRING SHALL BE BY THE REFRIGERATION INSTALLATION CONTRACTOR. 2. COORDINATE ALL SPECIFIED OVERHEAD CONTROL WIRING CONDUITS TO THE REFRIGERATED FIXTURES TO DROP AT THE SAME DROP LOCATIONS AS THE REFRIGERANT PIPING. REFER TO THE REFRIGERATION PIPING PLANS FOR THE OVERHEAD DROP LOCATIONS. 3. (2)#14S FROM EACH WALK-IN FREEZER/WALK-IN COOLER/ENCLOSED REFRIGERATED PREP ROOM TO THE EMC LEAK DETECTION CONTROL PANEL FOR THE REFRIGERANT LEAK SHUTDOWN/ALARM SYSTEM. SEE DETAIL ON PLAN EM104: ENERGY MANAGEMENT CONTROL DETAILS AND SCHEDULES FOR MORE INFORMATION. 4. REFER TO ELECTRICAL (E) PLANS BY BRANDT ENGINEERING, INC. FOR LIGHTING AND EQUIPMENT CONTACTOR SCHEDULE. REFER TO MECHANICAL (M) PLANS BY BRANDT ENGINEERING, INC. FOR MECHANICAL EQUIPMENT LOCATIONS. 5. REFER TO UNDERGROUND CONDUIT ROUTING (EU) PLANS BY BRANDT ENGINEERING, INC. FOR UNDERGROUND CONDUIT ROUTING. 6. EACH REFRIGERATED CASE/EVAPORATOR ON A SYSTEM SHALL BE IDENTIFIED WITH A UNIT LETTER (UPPERCASE) AND SYSTEM NUMBER WITH A SENSOR LETTER (LOWERCASE) AFTERWARDS. IF THERE IS MORE THAN ONE CASE/EVAPORATOR ON A SYSTEM. ALL SENSOR LETTERS SHALL BE ASSIGNED STARTING WITH 'a' FROM LEFT TO RIGHT WHEN VIEWED FROM THE FRONT (SALES AREA SIDE) OF THE CASE/EVAPORATOR LINE UP. 12/08/2021 02/07/22 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT CONTROL RISER & NOTES EM102 BSD NGS 1. ALL SOLID LINES ARE FIELD WIRING, UNLESS OTHERWISE NOTED. ALL DASHED WIRING IS EITHER EXISTING OR FACTORY INSTALLED. 2. DAYTON AIR SWITCH (2E462) IS TO BE WIRED IN ADDITION TO ANY OTHER SWITCHES LOCATED IN ELECTRIC DUCT HEATERS (IF APPLICABLE). 3. SPACE TEMPERATURE SENSORS AND DEWPOINT TEMPERATURE SENSORS ARE TO BE LOCATED ON COLUMNS OR RECESSED IN WALLS IN THE CENTER OF THE AREAS SERVED AND MOUNTED AT 84" A.F.F. COORDINATE WITH THE ELECTRICAL (E) AND MECHANICAL (M) PLANS BY BRANDT ENGINEERING, INC. 4. SUPPLY AIR TEMPERATURE SENSORS ARE TO BE LOCATED A MINIMUM OF 6’ DOWNSTREAM OF DUCT HEATERS. 5. ALL SHIELDED WIRES USED FOR SENSORS SHALL BE CUT OFF AND TAPED BACK ON THE SENSOR END OF THE WIRE. THE SHIELD SHALL BE GROUNDED TO THE GROUND LUG PROVIDED IN THE MAIN PANEL. 6. ALL CONTROL WIRES SHALL BE A MINIMUM OF 14 AWG (STRANDED), SHIELDED CABLES SHALL BE A MINIMUM OF 22 AWG. ALL WIRING TO BE IN CONDUIT PROVIDED AND INSTALLED BY EC. POWER WIRING SHALL NOT BE RUN IN THE SAME CONDUIT AS CONTROL WIRING. 7. INSTALLATION SHALL MEET ALL LOCAL, STATE, AND NATIONAL CODES AND IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 8. NETWORK COMMUNICATIONS CABLE MUST BE DAISY CHAINED. NO T-TAPPING IS ACCEPTABLE. 9. REFER TO PLAN EM103 FOR LIGHTING/EQUIPMENT RELAY CONTROL INPUT/OUTPUT SCHEDULES. REFER TO ELECTRICAL (E) PLANS BY BRANDT ENGINEERING, INC. FOR LIGHTING AND EQUIPMENT CONTACTOR SCHEDULE. 1. THE CONTROLLER INPUT/OUTPUT BOARDS SHOWN ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO CONVEY THE TYPICAL INSTALLATION WIRING REQUIREMENTS. SEE THE CPC CONTROL EQUIPMENT LIST FOR THE ACTUAL INPUT/OUTPUT BOARD COUNT. 2. IT IS THE RESPONSIBILITY OF THE REM TO PROVIDE THE SPECIFIED PREWIRED INPUT AND OUTPUT BOARDS AS SHOWN ON PLAN EM103 WITH THE PREWIRED INPUTS AND OUTPUTS AS SPECIFIED IN THE REFRIGERATION EQUIPMENT SPECIFICATIONS FOR ALL REFRIGERATION EQUIPMENT. THE REM SHALL COORDINATE ANY DISCREPANCIES WITH ochsrterEFS, p.c. PRIOR TO FABRICATION OF EQUIPMENT. 3. ALL LOOSE CPC AND EMC COMPONENTS FOR REFRIGERATION CONTROL TO BE FURNISHED BY THE REM AS SPECIFIED WITHIN THE REFRIGERATION EQUIPMENT SPECIFICATIONS. 4. ALL LOOSE CPC AND EMC COMPONENTS FOR MECHANICAL AND LIGHTING CONTROL TO BE FURNISHED BY THE REM AS SPECIFIED WITHIN THE REFRIGERATION EQUIPMENT SPECIFICATIONS. 5. REFER TO THE REFRIGERATION INSTALLATION SPECIFICATIONS AND REFRIGERATION EQUIPMENT SPECIFICATIONS FOR INFORMATION REGARDING THE ENERGY MANAGEMENT SYSTEM. 6. REFER TO MECHANICAL (M) PLANS BY BRANDT ENGINEERING, INC. FOR MECHANICAL EQUIPMENT LOCATIONS. 1. THE RIC SHALL COORDINATE WITH THE FIRE ALARM CONTRACTOR AND MECHANICAL CONTRACTOR ON FINAL SEQUENCE OF OPERATIONS FOR SHUTDOWN OF MECHANICAL UNITS. 2. ONCE THE MODIFIED EXISTINS CPC E2 BX-400E MECHANICAL/LIGHTING CONTROL SYSTEM HAS BEEN INSTALLED AND THE MECHANICAL SYSTEMS ARE READY TO BE BROUGHT ONLINE, THE MC & RIC MUST PROVIDE THE NECESSARY SUPERVISION FOR THE START-UP OF THE CONTROL SYSTEM. THE MC & RIC MUST ENSURE THAT ALL OF THE MECHANICAL SYSTEMS ARE OPERATING CORRECTLY AND PROVIDE ANY FINE TUNING OF THE SYSTEMS THAT IS REQUIRED. 3. REFER TO ALL NOTES FOR REFRIGERATION INSTALLATION CONTRACTOR AND REFRIGERATION EQUIPMENT MANUFACTURER. 1. THE RIC SHALL BE RESPONSIBLE FOR SUPERVISING THE COMPLETE INSTALLATION OF THE ENERGY MANAGEMENT SYSTEM. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, THE START-UP, PUNCHDOWN, AND PROGRAMMING OF THE ENTIRE REFRIGERATION CONTROL SYSTEM, MECHANICAL CONTROL SYSTEM, AND LIGHTING/ EQUIPMENT CONTROL SYSTEM. 2. THE RIC SHALL PROVIDE AND INSTALL ALL NECESSARY NETWORK COMMUNICATION, SENSOR, AND CONTROL WIRING IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC FOR ALL CONTROL EQUIPMENT FOR REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS. RIC SHALL BE RESPONSIBLE FOR SHIELDED CABLE AND CONTROL WIRE CONDUCTORS TO ALL DEVICES LISTED ON THE ENERGY MANAGEMENT (EM) PLANS AS REQUIRED FOR A COMPLETE INSTALLATION. THE RIC SHALL COORDINATE AND RESOLVE ALL CONDUIT RACEWAY DISCREPANCIES WITH THE EC. 3. THE RIC SHALL PROVIDE AND INSTALL ALL NECESSARY TUBING FOR THE CPC IRLDSII REFRIGERANT LEAK DETECTION SYSTEM. THE RIC SHALL BE RESPONSIBLE FOR ALL TUBING AND ASSOCIATED SUPPORTS FROM THE CONTROLLER TO ALL DEVICES LISTED ON THE ENERGY MANAGEMENT (EM) PLANS AS REQUIRED FOR A COMPLETE INSTALLATION. 4. THE RIC SHALL PROVIDE AND INSTALL ALL CONTROL WIRING BETWEEN THE RTU UNITS AND THE CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL TERMINATIONS OF THE CONTROL WIRING AT CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES AND TO THE RTU UNITS SHALL BE BY THE RIC. 5. THE RIC SHALL PROVIDE ALL COORDINATION BETWEEN THE VARIOUS TRADES, INCLUDING MECHANICAL AND ELECTRICAL, TO ENSURE THAT ALL EQUIPMENT IS PROPERLY CONTROLLED AND THAT ALL CONTROL POINTS HAVE BEEN ACCOMMODATED. THIS SHALL INCLUDE VERIFYING ALL MECHANICAL EQUIPMENT TO BE CONTROLLED, VERIFYING ALL STAGES OF HEATING, COOLING, HEAT RECLAIM, FANS, ETC. AND ENSURING THAT ADEQUATE SENSORS HAVE BEEN SUPPLIED TO ENABLE PROPER CONTROL OF SAME. 6. UPON COMPLETION OF THE EMS INSTALLATION, THE RIC SHALL PROVIDE ACCURATE AND COMPLETE AS-BUILT DOCUMENTATION TO THE OWNER AND THE ENGINEER. THIS DOCUMENTATION MUST INCLUDE AN 8-1/2" x 11" PLAN INDICATING THE LOCATIONS OF ALL OF THE SENSORS, RELAYS, REMOTE INPUT/OUTPUT BOARDS, CONTROLLERS, AND MODEM FOR THE REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS. 7. THE RIC SHALL FURNISH AND INSTALL A 48* x 36" PLAN WITH FRAME AND CLEAR PLEXI-GLASS COVER SHOWING THE FINAL LOCATIONS OF ALL OF THE REFRIGERATION CIRCUITS HIGHLIGHTED FOR EACH CORRESPONDING PARALLEL COMPRESSOR RACK. THIS PLAN SHALL BE PLACED IN THE EXISTING MEZZANINE MOTOR ROOM. 8. REFER TO ALL NOTES FOR REFRIGERATION EQUIPMENT MANUFACTURER 1. THE EC SHALL PROVIDE AND INSTALL ALL NECESSARY POWER FOR ALL CONTROL EQUIPMENT FOR REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS. EC SHALL BE RESPONSIBLE FOR CONDUIT RACEWAYS AND POWER WIRE CONDUCTORS TO ALL DEVICES LISTED ON ENERGY MANAGEMENT (EM) PLANS AS REQUIRED FOR A COMPLETE INSTALLATION. 2. THE EC SHALL PROVIDE AND INSTALL ALL NECESSARY CONDUIT RACEWAYS WITH PULL STRINGS FOR NETWORK COMMUNICATION, SENSOR, AND CONTROL WIRING FOR ALL CONTROL EQUIPMENT FOR REFRIGERATION, MECHANICAL, AND LIGHTING/EQUIPMENT CONTROL SYSTEMS AS FOLLOWS FOR THE APPROPRIATE LOCATIONS: UNDERGROUND: PVC CONDUIT WITH RIGID 90° CONDUIT TRANSITIONS THROUGH ALL CONCRETE SLABS. INTERIOR OVERHEAD AND ABOVE GRADE CONCEALED/EXPOSED: E.M.T. CONDUIT WITH COMPRESSION FITTINGS AND NEMA 1 JUNCTION BOXES/WIRING TROUGHS. FLEXIBLE METALLIC CONDUIT RACEWAYS NO GREATER THAN 6' IN LENGTH SHALL BE UTILIZED FOR ALL FINAL EQUIPMENT CONNECTIONS WHERE FLEXIBILITY IS REQUIRED. EXTERIOR AND INTERIOR WITHIN WALK-IN COOLERS/WALK-IN FREEZERS/REFRIGERATED PREP ROOMS: RIGID CONDUIT WITH THREADED FITTINGS AND NEMA 3R JUNCTION BOXES. WEATHERPROOF FLEXIBLE CONDUIT RACEWAYS NO GREATER THAN 6' IN LENGTH SHALL BE UTILIZED FOR ALL FINAL EQUIPMENT CONNECTIONS WHERE FLEXIBILITY IS REQUIRED. EC SHALL BE RESPONSIBLE FOR THE CONDUIT RACEWAYS TO ALL DEVICES LISTED ON ENERGY MANAGEMENT (EM) PLANS AS REQUIRED FOR A COMPLETE INSTALLATION. 3. THE EC SHALL PROVIDE ALL COMPONENTS AS REQUIRED FOR THE COMPLETE INSTALLATION OF THE LIGHTING/EQUIPMENT CONTROL SYSTEM. INSTALLATION SHALL INCLUDE, BUT NOT BE LIMITED TO, FURNISHING AND INSTALLING ALL LOOSE MECHANICAL/LIGHTING CONTROL CONTACTORS. SEE LIGHTING/EQUIPMENT CONTROL REQUIREMENTS ON ELECTRICAL (E) PLANS BY BRANDT ENGINEERING, INC. FOR LIGHTING AND EQUIPMENT CONTACTOR SCHEDULE. 4. THE EC SHALL BE RESPONSIBLE FOR ALL CONDUIT RACEWAYS AND POWER WIRE CONDUCTORS TO EACH REFRIGERATION SYSTEM AS SPECIFIED. 5. REFER TO ALL NOTES FOR REFRIGERATION INSTALLATION CONTRACTOR AND REFRIGERATION EQUIPMENT MANUFACTURER. 1. THE REM SHALL FURNISH AND FACTORY INSTALL THE CPC CONTROLS IN THE NEW PARALLEL COMPRESSOR RACK CONTROL PANELS AS SPECIFIED. THE INSTALLATION SHALL INCLUDE, BUT NOT BE LIMITED TO, THE INSTALLATION OF THE COPELAND INTELLIGENT STORE DISCUS 2.1 CONTROLS (CORESENSE DIAGNOSTICS), CPC MULTI-FLEX INPUT/OUTPUT BOARDS, CPC MULTI-FLEX ESR8 BOARDS, POWER SUPPLY, PRESSURE TRANSDUCERS, RECEIVER LEVEL TRANSDUCERS, TEMPERATURE SENSORS, POWER, AND CONTROL WIRING FROM THE CONTROL SYSTEM TO CONTROL DEVICES MOUNTED ON THE RACK, LOCAL RS485 COMMUNICATION, SENSOR, AND CONTROL WIRING BETWEEN INPUT/OUTPUT BOARDS (BELDEN #8761-2 #22 SHIELDED CABLE), AND ALL FINAL CONNECTIONS AS REQUIRED FOR A COMPLETE CONTROL SYSTEM. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 2. THE REM SHALL FURNISH THE REQUIRED LOOSE CPC PRESSURE TRANSDUCERS AND TEMPERATURE SENSORS FOR THE MODIFICATION OF THE EXISTING PARALLEL COMPRESSOR RACK. THE RIC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THESE COMPONENTS ON THE RACK INCLUDING ALL POWER, LOCAL RS485 COMMUNICATION (BELDEN #8761-2 #22 SHIELDED CABLE), SENSOR, AND TRANSDUCER WIRING INSTALLATION AND TERMINATION REQUIRED. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 3. THE REM SHALL FURNISH AND FACTORY INSTALL THE CPC CONTROLS IN THE NEW ELECTRIC DEFROST PANEL AND NEW ROOFTOP AIR-COOLED CONDENSER AS SPECIFIED. THE INSTALLATION SHALL INCLUDE, BUT NOT BE LIMITED TO, THE INSTALLATION OF THE CPC MULTI-FLEX INPUT/OUTPUT BOARDS, TRANSFORMERS, POWER SUPPLIES, AND CONTROL WIRING FROM THE CONTROL SYSTEM TO CONTROL DEVICES MOUNTED ON THE NEW ELECTRIC DEFROST PANEL AND NEW ROOFTOP AIR-COOLED CONDENSER, LOCAL RS485 COMMUNICATION WIRING BETWEEN INPUT/OUTPUT BOARDS (BELDEN #8761-2 #22 SHIELDED CABLE), AND ALL FINAL CONNECTIONS AS REQUIRED TO COMPLETE THE CONTROL SYSTEM. ALL FIELD COMMUNICATION AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 4. THE REM SHALL FURNISH THE REQUIRED LOOSE CPC WIRELESS GATEWAY RECEIVER, CPC IRLDS II CONTROLLER, EMC REFRIGERANT LEAK DETECTION CONTROL PANEL (LDCP), AND EMC OVERRIDE/ALARM FOR REFRIGERATION AND LIGHTING CONTROL TO THE RIC FOR INSTALLATION. THE RIC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE CPC WIRELESS GATEWAY RECEIVER, CPC IRLDS II CONTROLLER, EMC REFRIGERANT LEAK DETECTION CONTROL PANEL (LDCP), AND EMC OVERRIDE/ALARM PANEL FOR THE COMPLETE INSTALLATION OF THE REFRIGERATION AND LIGHTING CONTROL SYSTEMS. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FIELD TUBING AND ASSOCIATED SUPPORTS SHALL BE PROVIDED AND INSTALLED BY THE RIC. ALL FINAL CONNECTIONS BY THE RIC. 5. THE REM SHALL FURNISH THE REQUIRED LOOSE CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH ENCLOSURES, CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES; SPACE, SUPPLY AIR, RETURN AIR, AND SUCTION TEMPERATURE SENSORS; DEWPOINT TEMPERATURE SENSORS, AND DOMESTIC WATER HEATER TEMPERATURE SENSOR FOR THE COMPLETE INSTALLATION OF THE MECHANICAL CONTROL SYSTEM. THE RIC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH ENCLOSURES, ALL CPC MULTI-FLEX INPUT/OUTPUT BOARDS WITH WEATHERPROOF ENCLOSURES; SPACE, SUPPLY AIR, RETURN AIR, AND SUCTION TEMPERATURE SENSORS; DEWPOINT TEMPERATURE SENSORS, AND DOMESTIC WATER HEATER TEMPERATURE SENSOR FOR THE COMPLETE INSTALLATION OF THE MECHANICAL CONTROL SYSTEM. ALL FIELD COMMUNICATION, SENSOR, AND CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 6. THE CPC TEMPERATURE SENSORS FOR THE SPECIFIED DELFIELD REFRIGERATED CASES SHALL BE FURNISHED BY THE REM TO THE RIC FOR INSTALLATION. ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 7. THE CPC WIRELESS TEMPERATURE SENSORS FOR THE SELF-CONTAINED REFRIGERATED CASES SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. 8. THE CPC TEMPERATURE SENSORS FOR THE WALK-IN COOLERS, WALK-IN FREEZERS, AND REFRIGERATED PREP ROOMS SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 9. THE CPC IRLDS II END FILTERS FOR THE REFRIGERANT LEAK DETECTION SYSTEM FOR THE WALK-IN COOLERS, WALK-IN FREEZERS, ENCLOSED REFRIGERATED PREP ROOMS, MEZZANINE MOTOR ROOM, RETURN AIR DUCT, AND AMBIENT PURGE SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD TUBING AND ASSOCIATED SUPPORTS SHALL BE PROVIDED AND INSTALLED BY THE RIC. ALL FINAL CONNECTIONS BY THE RIC. 10. THE EMC REFRIGERANT LEAK INDICATORS FOR THE REFRIGERANT LEAK DETECTION SYSTEM FOR THE WALK-IN COOLERS, WALK-IN FREEZERS, ENCLOSED REFRIGERATED PREP ROOMS, AND MEZZANINE MOTOR ROOM SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 11. THE EMC DOOR MONITORING ALARMS FOR THE WALK-IN FREEZERS SHALL BE FURNISHED BY THE REM TO THE RIC FOR FIELD INSTALLATION. ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY THE RIC. 12. THE CPC AMBIENT TEMPERATURE SENSORS SHALL BE FURNISHED BY THE REM AND FIELD INSTALLED BY THE RIC. ALL FIELD SENSOR WIRING SHALL BE PROVIDED AND INSTALLED BY THE RIC IN THE CONDUIT RACEWAY SYSTEM PROVIDED AND INSTALLED BY THE EC. ALL FINAL CONNECTIONS BY RIC. 1. THE REFRIGERATION CASE MANUFACTURER SHALL FURNISH ALL REFRIGERATED CASE FIXTURES NOTED WITH CPC TEMPERATURE SENSORS. 2. THE REFRIGERATION CASE MANUFACTURER SHALL FURNISH ALL REFRIGERATED CASE FIXTURES NOTED WITH CPC DEFROST TERMINATION TEMPERATURE SENSORS. WIRE TYPES: WIRING SCHEDULE AND LEGEND 1 - BELDEN #8761 (2 #22 SHIELDED CABLE) 2 - BELDEN #8760 (2 #18 SHIELDED CABLE) 3 - BELDEN #8771 (3 #22 SHIELDED CABLE) 4 - BELDEN #8729 (4 #22 SHIELDED CABLE) 5 - 2 #14 6 - 2 #12 7 8 - 480V, 3Ø, DEDICATED POWER BY EC 9 - ECHELON NETWORK WIRING. ONE (1) PAIR CPC PART #135-2300 (NON-PLENUM) AND #135-2301 (PLENUM) - 120V, 1Ø, DEDICATED POWER BY EC ALL CONDUIT AND POWER WIRING FURNISHED BY EC. ALL 120V/1Ø OR 208V/1Ø CONTROL WIRING SHALL BE IN CONDUIT. ALL LOW VOLTAGE CONTROL/SENSOR WIRING SHALL BE IN CONDUIT. THE 120V/1Ø OR 208V/1Ø CONTROL WIRING SHALL NOT BE RUN IN THE SAME CONDUIT AS THE LOW VOLTAGE CONTROL/SENSOR WIRING. CABLE LEGEND: WIRING INSTALLED BY THE EC IN CONDUIT WIRING FACTORY INSTALLED NOTES: SYMBOL DESCRIPTION MF168 CPC INPUT (16) / RELAY OUTPUT (8) BOARD 8R0 CPC (8) RELAY OUTPUT BOARD MF88 CPC INPUT (8) / RELAY OUTPUT (8) BOARD ESR CPC MULTI-FLEX ESR BOARD ELECTRICAL CONTRACTOR MF168AO CPC INPUT (16) / RELAY OUTPUT (8), ANALOG OUTPUT (4) BOARD EMS WIRE TYPE1 CPC INPUT (16) BOARDMF16 EC 10 - CAT 5E CABLE BY TFM DATA WIRING CONTRACTOR. CSPM CORESENSE PROTECTION MODULE MOUNTED ON EACH RACK COMPRESSOR 8 RTU-1 MF168AO (FACTORY INSTALLED) ALL COMPONENTS WITHIN FACTORY INSTALLED AND PREWIRED. MF168AO MF168 MF168 RS485 I/O NETWORK A E2 CONTROLLER CX-300 #1 1 2 3 4 5 6 7 8 9 . 0 - 2EEINSTEIN MF168 8 ALL COMPONENTS WITHIN FACTORY INSTALLED AND PREWIRED. RACK PANEL "B" MF168AO MF168 MF168 RACK PANEL "A" 1 1 PRODIGY PRODIGY MF88 7 TFM BACKROOM HUB 10 PHONE LINE 10 LEAK DETECTION 8R0 ALL COMPONENTS WITHIN FACTORY INSTALLED AND PREWIRED. REFRIGERATION LEAK DETECTION SYSTEM (RLDS) 8RO REFRIGERATION 1 8RO CONTROL PANEL 8RO CONDENSER 'B' (FACTORY INSTALLED) (FACTORY INSTALLED) CONDENSER 'A' CSPM CSPMCSPM CSPM CSPM CSPM RS485 MODBUS NETWORK 1 MF88 MF88 1 E2 CONTROLLER RX-300 #2 1 2 3 4 5 6 7 8 9 . 0 - 2EEINSTEIN RS485 I/O NETWORK A RS485 MODBUS NETWORK MF88 MEAT CASE #1 (FACTORY INSTALLED) MF88 MEAT CASE #2 (FACTORY INSTALLED) 1 MF88 MEAT CASE #3 (FACTORY INSTALLED) 1 MF88 MEAT CASE #4 (FACTORY INSTALLED) 1 MF88 MEAT CASE #5 (FACTORY INSTALLED) 1 1 1 1 1 RS485 MODBUS COM4A COM4A COM4B 10 1 PANEL 'LA' PANEL 'LB' (SECTION 1) PANEL 'LB' (SECTION 2) PLM PLM PLM 4 4 12/08/2021 02/07/22 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 345 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT SCHEDULES & DETAILS EM103 BSD NGS OVERHEAD ADJACENT TO STUD WALL EMT CONDUIT IN WALL OVERHEAD EMT CONDUIT TO SPECIFIED LOCATION EMT CONDUIT ON FACE OF WALL UNDERGROUND ADJACENT TO CMU OR COOLER PANEL WALL UNDERGROUND ADJACENT TO STUD WALL UNDERGROUND FREE STANDING UNDERGROUND PVC CONDUIT TO SPECIFIED LOCATION FLOOR SLAB 4X4 JUNCTION BOX RECESSED IN WALL ELEVATION TO TOP OF JUNCTION BOX AT 90" A.F.F. PVC CONDUIT IN WALL FLEXIBLE METALLIC CONDUIT WHIP FOR CASE CONNECTION FLEXIBLE METALLIC CONDUIT WHIP FOR CASE CONNECTION RIGID CONDUIT 90° TRANSITION COUPLING FLEXIBLE METALLIC CONDUIT WHIP FOR CASE CONNECTION FLEXIBLE METALLIC CONDUIT WHIP FOR CASE CONNECTION FLOOR SLAB FLOOR SLABFLOOR SLAB ELEVATION TO TOP OF JUNCTION BOX AT 90" A.F.F. ELEVATION TO TOP OF JUNCTION BOX AT 90" A.F.F. 4X4 JUNCTION BOX RECESSED IN WALL 4X4 JUNCTION BOX RECESSED IN WALL N L CPC OUTPUT NO NCM 10A CUBE RELAY 2 7 3 OR 6 4 OR 5 1 OR 8 120V COIL N L 120V COIL CONTACTOR FOR ELECTEICALL HELD CONTACTORS 10 AMP CUBE RELAY FOR CPC OUTPUT CONTROL OF CONTACTORS EXCEEDING 2 AMP DRAW. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL. COMPARE CUBE RELAY NUMBERING AGAINST THIS DETAIL TO ENSURE CORRECT WIRING TERMINATIONS. CUBE RELAY PROVIDED MAY BE NUMBERED DIFFERENTLY. THE CORRESPONDING FAIL SAFE DIP SWITCH SHOULD BE PLACED IN THE 'UP' POSITION FOR CORRECT OPERATION OF THE RELAYS. 2 1 8 7 3 4 5 6 21834 65 7NOTE: REFRIGERATED CASES: ELECTRICAL CONTRACTOR SHALL FURNISH ALL CONDUIT RACEWAY MATERIALS REQUIRED FOR CONNECTION TO THE REFRIGERATION CASES. REFRIGERATION INSTALLATION CONTRACTOR TO MAKE ALL FINAL POWER WIRING CONNECTIONS TO REFRIGERATION CASES. REFRIGERATION INSTALLATION CONTRACTOR TO MAKE ALL FINAL SENSOR AND CONTROL WIRING CONNECTIONS TO REFRIGERATED CASES. SEE ELECTRICAL (E) PLANS BY ERDMAN ANTHONY WITH REGARDS TO POWER WIRING DETAILS. THE RIC SHALL WIRE THE REFRIGERATION CIRCUIT REMOTE LIQUID LINE SOLENOID VALVE TO THE FACTORY WIRED REFRIGERATION CIRCUIT OUTPUT. THE REM SHALL PROGRAM THE REFRIGERATION CIRCUIT TO SHUTDOWN UPON LEAK DETECTION BY THE CPC RLDS AND ACTIVATE THE EMC REFRIGERATION LEAK INDICATOR. WALK-IN COOLERS, WALK-IN FREEZERS AND ENCLOSED REFRIGERATION PREP ROOMS: RACK: NC PI NO CPC RELAY: NO NCM NO NCM NO NCM NO NCM NO NC M NO NC M NO NC M NO NCM FAN COOL/ DEHUMID 1 (OA) COOL/ DEHUMID 2 (OA) COOL 3 (OA) COOL / DEHUMID 4 NO NC M NO NC M NO NC M NO NC M NO NC M NO NC M NO NC M NO NCM GAS HT1 GAS HT 2 GAS HT 3 GAS HT 4 OA DAMPER OA DAMPER R G YI1 Y1B Y2 Y3 W1 W2 W3 W4 CFMCFM LOWHIGH RTUs: RTU-1 (SALES AREA) (MF168 BOARD) RTUs: RTU-1 (SALES AREA) (8RO BOARD) RTUs: RTU-4 (BAKERY); RTU-5 (KITCHEN); RTU-6 (VESTIBULE) (MF88 BOARD) NO NC M NO NC M NO NC M NO NC M NO NC M NO NCM NO NC M NO NCM FAN GAS HT 1 GAS HT 2 COOL 1 R G W1 W2 Y1 OA DAMPER MIN MAX COOL 2 Y2 UNDERGROUND PVC CONDUIT TO SPECIFIED LOCATION RIGID CONDUIT 90° UNDERGROUND PVC CONDUIT TO SPECIFIED LOCATION RIGID CONDUIT 90° UNDERGROUND PVC CONDUIT TO SPECIFIED LOCATION RIGID CONDUIT 90° 4 1 SWITCH: CIRCUIT HUB DRAIN DIMENSIONED 2 1 KICKPLATE FRONT (SALES AREA) FRONT OF CASE: SALES AREA (NO DRAIN SIDE)) (WALL, PREP AREA, BACK OF CASE, REAR OF CASE: CONDUIT RISERS TO THE LEFT OF REFRIGERATION CASE DRAIN BARKER REFRIGERATED CASES HUB DRAIN DIMENSIONED 21 KICKPLATE FRONT (SALES AREA) FRONT OF CASE: SALES AREA (NO DRAIN SIDE)) (WALL, PREP AREA, BACK OF CASE, REAR OF CASE: CONDUIT RISERS TO THE RIGHT OF REFRIGERATION CASE DRAIN HUSSMANN AND HILL PHOENIX REFRIGERATED CASES CL CL 1. POWER CONDUIT RISER FOR FAN, LIGHT, ANTI-SWEAT HEATERS, DEFROST -6' FLEXIBLE WHIP WITH ALL CONDUCTORS - ONE POWER RISER CONDUIT/WHIP PER REFRIGERATION CIRCUIT (EG). ALL JUMPERS BETWEEN CASES ON THE SAME REFRIGERATION CIRCUIT ARE INSTALLED BY THE ELECTRICAL CONTRACTOR. L F D 1. ALL SCALE POWER AND COMMUNICATION LOOP CONDUIT SPACED 6" TO THE RIGHT/LEFT OF CASE CONDUITS. 2. ALL POWER CONDUIT AND SENSOR CONDUIT RISERS ON LENGTH CENTERLINE OF HUB DRAIN DIMENSION. 2. SENSOR/CONDUIT RISER FOR TEMPERATURE SENSORS - 6' FLEXIBLE WHIP - ONE SENSOR/RISER CONDUIT/WHIP PER REFRIGERATION CIRCUIT (EG). ALL SHIELDED CABLE TO BE AS LONG AS FURTHEST CASE FROM RISER CONDUIT. - NO SPLICES WILL BE MADE IN SHIELDED CABLE. XH MF168AO AI Board #1 (I)MF168 AI Board #2 (I)MF168 AI Board #3 (I)MF168 AI Board #4 (I)168AO Board #1 (AO)MF168AO AI Board #1 (I)MF168 AI Board #2 (I)MF168 AI Board #3 (I)MF168 AI Board #4 (I)MF168 AI Board #5 (I)168AO Board #1 (AO) Compressor Panel A Compressor Panel A Compressor Panel A Compressor Panel A Compressor Panel A Compressor Panel B Compressor Panel B Compressor Panel B Compressor Panel B Compressor Panel B Compressor Panel B CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 RX-300 #2 RX-300 #2 RX-300 #2 RX-300 #2 RX-300 #2 RX-300 #2 1 *Suction Pressure - A 1 A1A- Box Temp 1 A8B- Defrost Temp 1 1 *Digital Unloader Comp A1 1 *Suction#1 Pressure - B 1 B1A- Box Temp 1 B11A- Case Temp 1 B20A- Box Temp 1 B32A- Case Temp 1 *Digital Unloader Comp B1 2 *Discharge Pressure - A 2 A1A- Defrost Temp 2 A8C- Case Temp 2 2 2 *Suction#2 Pressure - SB 2 B1A- Defrost Temp 2 B12A- Case Temp 2 B21A- Box Temp 2 B33A- Case Temp 2 *Digital Unloader Comp SB1 3 *Drop Leg Pressure - A 3 A1B- Defrost Temp 3 A8C- Defrost Temp 3 3 3 *Discharge Pressure - B 3 B2A- Box Temp 3 B12B- Case Temp 3 B22A- Box Temp 3 B33B- Case Temp 3 4 *Suction Header Temp - A 4 A2A- Box Temp 4 A9A- Case Temp 4 4 4 *Drop Leg Pressure - B 4 B3A- Box Temp 4 B13A- Case Temp 4 B23A- Box Temp 4 B33C- Case Temp 4 5 *Drop Leg Temp - A 5 A2A- Defrost Temp 5 A9A- Defrost Temp 5 *Note: Prewired Output 5 *Suction#1 Header Temp - B 5 B4A- Box Temp 5 B13B- Case Temp 5 B24A- Box Temp 5 B33D- Case Temp *Note: Prewired Output 6 *Liquid Header Temp- A 6 A3A- Box Temp 6 A9B- Case Temp 6 6 *Suction#2 Header Temp - SB 6 B4A- Defrost Temp 6 B14A- Case Temp 6 B25A- Case Temp 6 B34A- Case Temp 7 *Compressor A Digital Alarm 7 A3A- Defrost Temp 7 A9B- Defrost Temp 7 7 *Drop Leg Temp - B 7 B5A- Case Temp 7 B14B- Case Temp 7 B25B- Case Temp 7 B35A- Case Temp 8 *Rupture Disk Alarm 8 A5A- Case Temp 8 A10A- Case Temp 8 8 *Liquid Header Temp- B 8 B5B- Case Temp 8 B14C- Case Temp 8 B26A- Case Temp 8 B36A- Case Temp 9 *Separator Diff Alarm 9 A5A- Defrost Temp 9 A10A- Defrost Temp 9 9 *Compressor B1 Digital Alarm 9 B8A- Case Temp 9 B14D- Case Temp 9 B27A- Case Temp 9 B37A- Case Temp 10 *Phase Loss Alarm - A 10 A6A- Case Temp 10 A10B- Case Temp 10 10 *Compressor B3 Digital Alarm 10 B8B- Case Temp 10 B14E- Case Temp 10 B27B- Case Temp 10 B37B- Case Temp 11 *Refrigerant Level - A 11 A6A- Defrost Temp 11 A10B- Defrost Temp 11 11 *Rupture Disk Alarm 11 B8C- Case Temp 11 B15A- Case Temp 11 B27C- Case Temp 11 12 *Motor Room Temp Sensor 12 A7A- Case Temp 12 A10C- Case Temp 12 Loading Dock Temp 12 *Separator Diff Alarm 12 B10A- Case Temp 12 B16A- Case Temp 12 B28A- Case Temp 12 13 Cond A Ambient Temp Sensor 13 A7A- Defrost Temp 13 A10C- Defrost Temp 13 Ltg Override A,B2,C2 13 *Phase Loss Alarm - B 13 B10B- Case Temp 13 B17A- Case Temp 13 B29A- Case Temp 13 14 Hot Water Reclaim Temp 14 A8A- Case Temp 14 A10D- Case Temp 14 Ltg Override B1,C1 14 *Refrigerant Level - B 14 B10C- Case Temp 14 B17B- Case Temp 14 B29B- Case Temp 14 15 Hot Water Supply Temp 15 A8A- Defrost Temp 15 A10D- Defrost Temp 15 Ltg Override EMR 15 Cond B Ambient Temp Sensor 15 B10D- Case Temp 15 B17C- Case Temp 15 B30A- Case Temp 15 16 Recirc Pump Flow Switch 16 A8B- Case Temp 16 A10E- Case Temp 16 Ltg Override OS 16 16 B10E- Case Temp 16 B19A- Box Temp 16 B31A- Case Temp 16 *Note: Prewired Input *Note: Prewired Input 168AO Board #1 (DO)168 Board #2 (DO)168 Board #3 (DO)168 Board #4 (DO)168AO Board #1 (DO)MF168 Board #2 (DO)MF168 Board #3 (DO)MF168 Board #4 (DO)MF168 Board #5 (DO)8RO Board #6 (DO) Compressor Panel A Compressor Panel A Compressor Panel A Compressor Panel A Compressor Panel B Compressor Panel B Compressor Panel B Compressor Panel B Compressor Panel B Compressor Panel B CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 RX-300 #2 RX-300 #2 RX-300 #2 RX-300 #2 RX-300 #2 RX-300 #2 1 *Compressor A1 1 A1 - Refrig (LLSV**)1 *A3 - Electric Defrost 1 *A8 - Refrig (EPR & LLSV**)1 *Compressor B1 1 B1 - Refrig (LLSV**)1 *B5 - Refrigeration 1 *B13 - Refrigeration 1 B22 - Refrig (LLSV**)1 *B30 - Refrigeration 2 *Compressor A2 2 *A1 - Evaporator Fans 2 *A5 - Refrig (EPR & LLSV**)2 *A8 - Electric Defrost 2 *Compressor B2 2 *B1 - Evaporator Fans 2 *B6 - Refrigeration 2 *B14 - Refrigeration 2 B23 - Refrig (LLSV**)2 *B31 - Refrigeration 3 Remote Alarm Relay (See Note)3 *A1 - Electric Defrost 3 *A5 - Electric Defrost 3 3 *Compressor SB1 3 *B1 - Electric Defrost 3 *B7 - Refrigeration 3 *B15 - Refrigeration 3 B24 - Refrig (LLSV**)3 *B32 - Refrigeration 4 *A9B Cond Bypass Valve 4 A2 - Refrig (LLSV**)4 *A6 - Refrig (EPR & LLSV**)4 4 *Compressor SB2 4 B2 - Refrig (LLSV**)4 *B8 - Refrigeration 4 *B16 - Refrigeration 4 *B25 - Refrigeration 4 *B33 - Refrigeration 5 *H.W. Heat Reclaim Valve - A 5 *A2 - Evaporator Fans 5 *A6 - Electric Defrost 5 5 *Standard Unloader B2 5 B3 - Refrig (LLSV**)5 *B9 - Refrigeration 5 *B17 - Refrigeration 5 *B26 - Refrigeration 5 *B34 - Refrigeration 6 *Standard Unloader A2 6 *A2 - Electric Defrost 6 *A7- Refrig (EPR & LLSV**)6 6 *Standard Unloader SB2 6 B4 - Refrig (LLSV**)6 *B10 - Refrigeration 6 B19 - Refrig (LLSV**)6 *B27 - Refrigeration 6 *B35 - Refrigeration 7 7 A3 - Refrig (LLSV**)7 *A7 - Electric Defrost 7 7 *A9B Cond Bypass Valve 7 *B4 - Evaporator Fans 7 *B11 - Refrigeration 7 B20 - Refrig (LLSV**)7 *B28 - Refrigeration 7 *B36 - Refrigeration 8 8 *A3 - Evaporator Fans 8 8 8 *Space Heat Reclaim - B 8 *B4 - Electric Defrost 8 *B12 - Refrigeration 8 B21 - Refrig (LLSV**)8 *B29 - Refrigeration 8 *B37 - Refrigeration *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output *Note: Prewired Output **Note: LLSV is field wired **Note: LLSV is field wired **Note: LLSV is field wired **Note: LLSV is field wired **Note: LLSV is field wired **Note: LLSV is field wired **Note: LLSV is field wired 8RO Board #14 (DO) Condenser 'A' CX-300 #1 1 *Condenser Fans - Stage 1 2 *Condenser Fans - Stage 2 3 *Condenser Fans - Stage 3 4 *Condenser Fans - Stage 4 5 6 7 8 *Split Condenser *Note: Prewired Output 8RO Board #11 (DO) Condenser 'B' RX-300 #2 1 *Condenser Fans - Stage 1 2 *Condenser Fans - Stage 2 3 *Condenser Fans - Stage 3 4 *Condenser Fans - Stage 4 5 *Condenser Fans - Stage 5 6 7 8 *Split Condenser *Note: Prewired Output 8RO Board #12 (DO) LEAK DETECTION CONTROLLER RX-300 #2 1 Horn Enable- RTU1 Return Air- RDLS Port 1 2 Motor Room - RLDS port 2 3 A1- Bakery Freezer - RLDS port 3 4 A2- Ice Cream - RLDS port 4 5 A3- Meat/Seafood Freezer - RLDS port 5 6 B1- Meat/Seafood Cooler - RLDS port 6 7 B2- DairyCooler - RLDS port 7 8 B3- Bakery Cooler - RLDS port 8 8RO Board #13 (DO) LEAK DETECTION CONTROLLER RX-300 #2 1 B23- Meat/Seafood Prep - RLDS port 9 2 B4- Cold Cooked Cooler - RLDS port 10 3 B22- Cold Cooked Prep - RLDS port 11 4 B24- Produce Prep- RLDS port 12 5 B19- Produce Cooler - RLDS port 13 6 B21- Floral Cooler - RLDS port 14 7 8 MF168AO Board #5 (I)ETR Prodigy Board #1 (I)ETR Prodigy Board #2 (I)MFRCB Board #1 (I)MFRCB Board #2 (I)MFRCB Board #3 (I) RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 RTU-6 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 1 Space Temp Sensor #1 1 Space Temperature Sensor 1 Space Temperature Sensor 1 Space Temperature Sensor 1 Space Temperature Sensor 1 Space Temperature Sensor 2 Space Temp Sensor #2 2 Supply Air Temp Sensor 2 Supply Air Temp Sensor 2 Supply Air Temp Sensor 2 Supply Air Temp Sensor 2 Supply Air Temp Sensor 3 Dew Point Sensor - Sales 3 Return Air Temp Sensor 3 Return Air Temp Sensor 3 Return Air Temp Sensor 3 Return Air Temp Sensor 3 Return Air Temp Sensor 4 Supply Air Temp Sensor 4 TXV Bulb / Suction Temp 4 TXV Bulb / Suction Temp 4 TXV Bulb / Suction Temp 4 TXV Bulb / Suction Temp 4 TXV Bulb / Suction Temp 5 *Return Air Temp Sensor 5 5 5 Bakery Fan Run Proof 5 Dew Point Sensor 5 6 *Mixed Air Temp Sensor 6 6 6 6 6 7 *Coil Leaving Air Temp 7 7 7 7 7 8 *Post Heat Reclaim Temp 8 8 8 8 8 9 *OA Damper Feedback 10 *Comp #1 Suction Temp 11 *Comp #2 Suction Temp 12 *Fan Status Proof 13 *Drain Pan Float Switch 14 *Outside Due Point 15 *Ambient Temp 16 *Light Level Sensor-See Note *Note: Prewired Input MF168AO Board #5 (O)168AO Board #2 (AO)ETR Prodigy Board #6 (O)ETR Prodigy Board #7 (O)MFRCB Board #1 (O)MFRCB Board #2 (O)RCB88 Board #3 (O) RTU-1 RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 RTU-6 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 CX-300 #1 1 *Main Fan 1 *Digital Compressor#1 Signal 1 Main Fan 1 Main Fan 1 Main Fan 1 Main Fan 1 Main Fan 2 *Cool 1 2 2 Cool 1 2 Cool 1 2 Cool 1 2 Cool 1 2 Cool 1 3 *Cool 2 3 3 3 3 Cool 2 3 Cool 2 3 Cool 2 4 *Heat 1 4 4 Heat 1 4 Heat 1 4 Heat 1 4 Heat 1 4 Heat 1 5 *Heat 2 *Note: Prewired Output 5 Heat 2 5 Heat 2 5 Heat 2 5 Heat 2 5 Heat 2 6 *OA Damper Control 6 Outside Air Damper 6 Outside Air Damper 6 Outside Air Damper 6 Outside Air Damper 6 Outside Air Damper 7 7 7 7 7 *Dehumidification-Hot Gas 7 8 8 8 8 8 8 *Note: Prewired Output *Note: Connect to pink wires on RTU 12/08/2021 02/07/22 SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE PROJECT NO. SHEET TITLE ISSUES & REVISIONS DRAWN BY: PROFESSIONAL SEAL PROJECT MANAGER: DOCUMENT DATE: CHECKED BY: PROJECT NAME PROJECT ADDRESS 1 2 3 4 5 ABCDEABCDE12 3 4 5 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 ARCHITECT OF RECORD: 62930563 12/07/2021 THE FRESH MARKET The Centre Retail Center NO. DATE DESCRIPTION An Erdman Anthony Company 552 Fort Evans RD STE 200 Leesburg, VA 20176 703.777.5988 Leesburg@erdmananthony.com 116th St. and Rangeline Rd. Carmel, Indiana ENERGY MANAGEMENT CONTROL DETAILS EM104 BSD NGS DEFROST BREAKER OR FUSES DEFROST CONTACTOR DEFROST RELAY DEFROST BREAKER OR FUSES DEFROST CONTACTOR SYSTEM SWITCH DEFROST LIGHT NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. 1 PHASE DEFROST (AS REQUIRED) (ONE PER CASE) PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. PRE-WIRED IN DEFROST PANEL. ESR VALVE (AT RACK OR REMOTE LOCATION) TO ESR BOARD LOW VOLTAGE TEMP PROBE FOR DEFROST TERM. (ONE PER CASE) TEMP PROBE (ONE PER CASE) TO MF168 INPUT BOARD ANALOG INPUT (AI) TO MF168 INPUT BOARD ANALOG INPUT (AI) NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. DEFROST BREAKER OR FUSES DEFROST CONTACTOR DEFROST RELAY SYSTEM SWITCH DEFROST LIGHT PRE-WIRED PANEL LOCATED IN DEFROST PANEL. LOW TEMP PROBE FOR DEFROST TERM. (ONE PER EVAP COIL) TEMP PROBE (ONE PER WALK-IN) TO MF168 INPUT BOARD ANALOG INPUT (AI) TO MF168 INPUT BOARD ANALOG INPUT (AI) NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. DEFROST HEATER FAN DELAY DOOR SWITCH TO MF168 INPUT BOARD DIGITAL INPUT (DI) DEFROST HEATER FAN DELAY FAN RELAY FAN BREAKER OR FUSES FAN NOTE: VERIFY ALL CONNECTIONS WITH CASE WIRING DIAGRAMS. SWITCH BY E.C. MOUNT ON UNIT COIL. NOTE: VERIFY ALL CONNECTIONS WITH CASE WIRING DIAGRAMS. NOTE: VERIFY ALL PANEL DIAGRAMS. BREAKER OR FUSES DEFROST CONTACTOR DEFROST RELAY SYSTEM SWITCH DEFROST LIGHT PRE-WIRED PANEL LOCATED IN DEFROST PANEL. NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. TEMP PROBE FOR DEFROST TERM. (ONE PER EVAP COIL) LOW VOLTAGE TEMP PROBE (ONE PER WALK-IN) TO MF168 INPUT BOARD ANALOG INPUT (AI) TO MF168 INPUT BOARD ANALOG INPUT (AI) DEFROST HEATER FAN DELAY FAN RELAY FAN CONTACTOR FAN BREAKER OR FUSES NOTE: VERIFY ALL CASE WIRING DIAGRAMS. CONNECTIONS WITH PANEL DIAGRAMS. NON-ESR VALVE (AT RACK OR REMOTE LOCATION) PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. ESR VALVE (AT RACK OR REMOTE LOCATION) TO ESR BOARD NON-ESR VALVE (AT RACK OR REMOTE LOCATION) PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. TO ESR BOARD NON-ESR VALVE (AT RACK OR REMOTE LOCATION) ESR VALVE (AT RACK OR REMOTE LOCATION) 1 PHASE DEFROST DEFROST HEATER FAN DELAY TO MF168 OUTPUT BOARD TO MF168 OUTPUT BOARD TO MF168 OUTPUT BOARD 2 POLE WP SERVICE SWITCH BY E.C. MOUNT ON UNIT COIL. ANTI-SWEAT HEATER (IF REQUIRED) TO CIRCUIT BREAKER IN ELECTRICAL PANEL PRE-WIRED PANEL LOCATED AT COMPRESSOR RACK. LOW VOLTAGE TEMP PROBE (ONE PER CASE) TO MF168 INPUT BOARD ANALOG INPUT (AI) NOTE: VERIFY ALL CONNECTIONS WITH PANEL DIAGRAMS. TO ESR BOARD NON-ESR VALVE (AT RACK OR REMOTE LOCATION) ESR VALVE (AT RACK OR REMOTE LOCATION) TO MF168 OUTPUT BOARD NOTES: 1. HEAT TRACE CABLE, SELF LIMITING TYP FOR FREEZER PROTECTION, WITH PARALLEL CONNECTED HEATER ZONES, 5 WATT/FT., 120V, SIMILAR AND EQUAL TO RAYCHEM 5XL-1. VERIFY WITH REFRIGERATION CONTRACTOR MODEL OF HEAT TRACE TAPE AND INSTALLATION REQUIREMENTS. 2. 7.9" PITCH WILL REQUIRE 1.2" CABLE/FT. PIPE. 3. INSULATION TO BE INSTALLED BY REFRIGERATION CONTRACTOR. 4 FOR USE IN ALL FREEZERS AND MEAT COOLERS. 5 HEAT TRACE TAPE SUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. 6 REFER TO SPECIFICATIONS FOR TYPICAL ROUTING. 3/4" INSULATION TRAP STANDPIPE DRAINAGE TUBE NYLON TIES TIE WRAP ICE CREAM ICE CREAM ICE CREAM HEAT TRACE CABLE TO BE EXTENDED FOR FULL LENGTH OF DRAIN PIPE POWER CONNECTION FLEX CONDUIT (SEE RAYCHEM INSTALLATION GUIDE). NEMA 4X VAPOR PROOF JUNCTION BOX. FREEZER WALL RIGID P.V.C. CONDUIT, INSTALL #12 GROUND WIRE WITH OTHER CONDUCTORS. PACK CONDUIT TIGHTLY WITH FIBERGLASS INSULATION. SEAL BOTH ENDS WITH DUCT SEAL. TO GFCI CIRCUIT BREAKER WITH 30mA TRIP SETTING (TYPICAL FOR ALL HEAT TRACE CIRCUITS). EVAPORATOR *PLASTIC FLUSH SWITCH BOXES AND PVC CONDUIT INSTALLED AT FACTORY. ALL CONDUIT TO BE INSTALLED INSIDE FREEZER. NOTE: 1 . FLOOR FREEZER DOOR LIGHTING FIXTURE MOUNTED INSIDE FREEZER CONNECT TO DOOR TRIM HEATER 120V POWER FOR FREEZER DOOR HEATER JUNCTION BOX MOUNTED ON TOP OF FREEZER * PRESS SWITCH WITH A PRESS PILOT LIGHT. FACTORY INSTALLED CONDUIT CONNECT TO PRESSURE RELIEF LOUVERS JUNCTION BOX MOUNTED ON TOP OF FREEZER 120V POWER SOURCE INSULATION DOOR SWITCH\STROBE\HORN FLOOR COMPRESSOR ROOM FROM HORN/STROBE TO REFRIGERATION CONTROL PANEL. SEE SHEET RC101. VOLTAGE SURFACE MOUNTED EMC-RLI 24V STROBE LIGHT AND HORN PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER AND INSTALLED BY RC. RIC TO PROVIDE AND INSTALL PARKER PARAFLEX SERIES FRPE 1/4" SENSING TUBING FROM RLDS UNIT TO THE END OF THE REFRIGERATION RACK CLOSEST TO THE EXHAUST FAN. FILTER PROVIDED WITH RLDS UNIT. CONTACTOR 2 POLE WP SERVICE CONNECTIONS WITH DEFROST INTAKE HOOD EXHAUST FAN COMPRESSOR RACK FLOOR OR PREP DOOR CONNECTIONS WITH NOTE: VERIFY ALL NOTE: EC SHALL PROVIDE JUNCTION BOXES AND CONDUIT PER DIRECTION OF THE RC. FROM DOOR SWITCH CONTACTS TO EMS CONTROL SYSTEM. SEE SHEET RC101. (COOLERS, FREEZERS & PREP ROOMS) SURFACE MOUNTED EMC-RLI 24V STROBE LIGHT AND HORN PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER AND INSTALLED BY RC ON PRE-INSTALLED JUNCTION BOX CENTERED ABOVE DOOR. IF WALK-IN OR PREP DOOR OPENS OUT INTO A SPACE VISIBLE TO THE PUBLIC, EMC-RLI UNIT TO BE INSTALLED INSIDE WALK-IN/PREP ROOM. (FREEZERS ONLY) SURFACE MOUNTED EMC-DMA 120V COMBINATION DOOR SWITCH\STROBE LIGHT AND HORN PROVIDED BY REFRIGERATION EQUIPMENT MANUFACTURER AND INSTALLED BY EC. WALK-IN FROM HORN/STROBE TO REFRIGERATION CONTROL PANEL. SEE SHEET RC101. RIC TO PROVIDE AND INSTALL PARKER PARAFLEX SERIES FRPE 1/4" SENSING TUBING FROM RLDS UNIT, THROUGH CONDUIT PRE INSTALLED IN WALL OF THE WALK-IN OR PREP ROOM. FILTER PROVIDED WITH RLDS UNIT AND SHALL BE LOCATED IN PRE INSTALLED 4"X4" BOX. PROVIDE SEALANT PIPING GOOSENECK REFRIG INTAKE LINE FILTER PROVIDED WITH RLDS UNIT. RIC TO PROVIDE AND INSTALL PARKER PARAFLEX SERIES FRPE 1/4" SENSING TUBING FROM RLDS UNIT UP THROUGH REFRIGERATION PIPING GOOSENECK FOR RLDS INTAKE AND EXHAUST. SEE NOTE 7 ON RC101. 12/08/2021 02/07/22