HomeMy WebLinkAboutRangeline (Carmel) IN - Structural CalculationsSTRUCTURAL
CALCULATIONS
PROJECT:
THE FRESH MARKET,
CARMEL, IN
AVS JOB NO. 8116
CLIENT:
BRR ARCHITECTURE
8131 METCALF, SUITE 300
OVERLAND PARK, KANSAS 66204
A. V. SCHWAN & ASSOCIATES
CONSULTING STRUCTURAL ENGINEERS
6000 E. THOMAS ROAD, SUITE 1
SCOTTSDALE, ARIZONA 85251
602.265.4331
www.AVSchwan.com
1
2
3
4
A.V. Schwan & Associates JOB TITLE The Fresh Market
6000 E Thomas Rd
Scottsdale, AZ 85251 JOB NO.8116 SHEET NO.
602-265-4331 CALCULATED BY BG DATE
CHECKED BY DATE
Ultimate Wind Pressures
Wind Loads - Components & Cladding : h ≤ 60'
Kh (case 1) =0.93 h =23.0 ft 0.2h =4.6 ft
Base pressure (qh) =22.7 psf 0.6h =13.8 ft
Minimum parapet ht = 2.0 ft GCpi = +/-0.18
Roof Angle (θ) = 1.2 deg qi = qh = 22.7 psf
Type of roof = Monoslope
Roof Surface Pressure (psf)User input
Area 10 sf 20 sf 50 sf 100 sf 200 sf 350 sf 500 sf 1000 sf 25 sf 50 sf
Negative Zone 1 -42.7 -39.9 -36.2 -33.3 -30.5 -28.2 -26.8 -26.8 -39.0 -36.2
Negative Zone 1'-24.5 -24.5 -24.5 -24.5 -21.1 -18.3 -16.6 -16.0 -24.5 -24.5
Negative Zone 2 -56.3 -52.7 -47.9 -44.3 -40.7 -37.7 -35.9 -35.9 -51.5 -47.9
Negative Zone 3 -76.8 -69.5 -59.9 -52.7 -45.5 -39.6 -35.9 -35.9 -67.2 -59.9
Positive All Zones 16 16 16 16 16.0 16.0 16.0 16.0 16.0 16.0
Overhang Zone 1&1'-38.6 -37.9 -37 -36.3 -30.5 -25.7 -22.7 -22.7 -37.7 -37.0
Overhang Zone 2 -52.2 -47.4 -41 -36.2 -31.4 -27.5 -25.0 -25.0 -45.8 -41.0
Overhang Zone 3 -72.7 -64.2 -53.1 -44.6 -36.2 -29.3 -25.0 -25.0 -61.5 -53.1
Overhang pressures in the table above assume an internal pressure coefficient (Gcpi) of 0.0
Overhang soffit pressure equals adj wall pressure (which includes internal pressure of 4.1 psf)
Parapet
qp =23.1 psf Surface Pressure (psf)User input
Solid Parapet Pressure 10 sf 20 sf 50 sf 100 sf 200 sf 500 sf 50 sf
CASE A: Zone 2 : 76.3 71.4 64.9 59.9 55.0 48.5 64.9
Zone 3 : 97.1 88.5 77.1 68.5 59.9 48.5 77.1
CASE B : Interior zone : -48.5 -46.1 -42.8 -40.4 -37.9 -34.7 -42.8
Corner zone : -55.5 -51.8 -46.9 -43.2 -39.5 -34.7 -46.9
wall a =9.2 ft
Walls GCp +/- GCpi Surface Pressure at h
Area 10 sf 100 sf 200 sf 500 sf 10 sf 100 sf 200 sf 500 sf 10 sf 200 sf
Negative Zone 4 -1.28 -1.10 -1.05 -0.98 -29.1 -25.1 -23.8 -22.3 -29.1 -23.8
Negative Zone 5 -1.58 -1.23 -1.12 -0.98 -35.9 -27.9 -25.4 -22.3 -35.9 -25.4
Positive Zone 4 & 5 1.18 1.00 0.95 0.88 26.8 22.8 21.6 20.0 26.8 21.6
User input
5
A.V. Schwan & Associates JOB TITLE The Fresh Market
6000 E Thomas Rd
Scottsdale, AZ 85251 JOB NO.8116 SHEET NO.
602-265-4331 CALCULATED BY BG DATE
CHECKED BY DATE
Location of C&C Wind Pressure Zones - ASCE 7-16
Roofs w/ θ ≤ 10° Walls h ≤ 60' Gable, Sawtooth and
and all walls & alt design h<90'Multispan Gable θ ≤ 7 degrees & Monoslope roofs
h > 60'Monoslope ≤ 3 degrees 3° < θ ≤ 10°
h ≤ 60' & alt design h<90' h ≤ 60' & alt design h<90'
Monoslope roofs Multispan Gable & Hip 7° < θ ≤ 27°
10° < θ ≤ 30° Gable 7° < θ ≤ 45°
h ≤ 60' & alt design h<90'
Sawtooth 10° < θ ≤ 45°
h ≤ 60' & alt design h<90'
Stepped roofs θ ≤ 3°
h ≤ 60' & alt design h<90'
6
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Roof Framing -
Joist at RTU5 -
Enter Length:≔A +33 ft 8 in ≔B +6 ft 2 in ≔C +10 ft 2 in
≔L =++A B C 50 ft
Enter Trib Width:≔s +5 ft 0 in
Enter (E) Loads:≔DL 20 psf ≔LR 20 psf
≔W DL LR[[]]
Loads in plf:≔w =⋅W s 100 100[[]]plf
Total Load:=∑w 200 plf
Load from Unit:≔P =⋅―――1000 lbf
2 ―1
2 0.25 kip
See attached enercalc printout for moment and shear values
≔M 61.733 ft·kip ≔V 4.969 kip
Equivalent Uniform Load:≔weq =―――((⋅M 8))
L2 197.546 plf
Existing 30K(248/138) Joist O.K.
JOB NO: 8116
7
General Beam
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Joist at RTU 5
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 30 NOV 2021, 5:16PM
Project Descr:Carmel, IN
General Beam Properties
Elastic Modulus ksi29,000.0
100.0Span #1 in^4Area = in^2 Moment of Inertia =Span Length =10.050.0 ft
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Uniform Load : D = 0.10 k/ft, Tributary Width = 1.0 ft
Uniform Load : Lr = 0.10 k/ft, Extent = 0.0 -->> 33.670 ft, Tributary Width = 1.0 ft
Uniform Load : Lr = 0.10 k/ft, Extent = 39.830 -->> 50.0 ft, Tributary Width = 1.0 ft
Point Load : D = 0.250 k @ 33.670 ft
Point Load : D = 0.250 k @ 39.830 ft
.DESIGN SUMMARY
Maximum Bending =
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 24.750 ft
4.969 k
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination +D+Lr
Maximum Shear =
0.000 ft
61.733 k-ft
Maximum Deflection
Max Downward Transient Deflection 4.200 in 142
Max Upward Transient Deflection 0.067 in 8975
Max Downward Total Deflection 9.640 in 62
Max Upward Total Deflection 0.051 in 11745
8
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Joist at MUA1 -
Enter Length:≔A +7 ft 10 in ≔B +9 ft 0 in ≔C +24 ft 2 in
≔L =++A B C 41 ft
Enter Trib Width:≔s +5 ft 6 in
Enter (E) Loads:≔DL 20 psf ≔LR 20 psf
≔W DL LR
[[]]
Loads in plf:≔w =⋅W s 110 110[[]]plf
Total Load:=∑w 220 plf
Load from Unit:≔P =⋅―――1500 lbf
2 ―1
2 0.375 kip
See attached enercalc printout for moment and shear values
≔M 44.759 ft·kip ≔V 4.438 kip
Equivalent Uniform Load:≔weq =―――((⋅M 8))
L2 213.011 plf
Existing 30K(267/149) Joist O.K.
JOB NO: 8116
9
General Beam
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Joist at MUA 1
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 30 NOV 2021, 5:19PM
Project Descr:Carmel, IN
General Beam Properties
Elastic Modulus ksi29,000.0
100.0Span #1 in^4Area = in^2 Moment of Inertia =Span Length =10.041.0 ft
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Uniform Load : D = 0.110 k/ft, Tributary Width = 1.0 ft
Uniform Load : Lr = 0.110 k/ft, Extent = 0.0 -->> 7.830 ft, Tributary Width = 1.0 ft
Uniform Load : Lr = 0.110 k/ft, Extent = 16.830 -->> 41.0 ft, Tributary Width = 1.0 ft
Point Load : D = 0.3750 k @ 7.830 ft
Point Load : D = 0.3750 k @ 16.830 ft
.DESIGN SUMMARY
Maximum Bending =
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 20.910 ft
4.438 k
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination +D+Lr
Maximum Shear =
41.000 ft
44.759 k-ft
Maximum Deflection
Max Downward Transient Deflection 1.768 in 278
Max Upward Transient Deflection 0.027 in 18382
Max Downward Total Deflection 4.682 in 105
Max Upward Total Deflection 0.028 in 17655
10
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Joist at RTU4 -
Enter Length:≔A +21 ft 8 in ≔B +6 ft 4 in ≔C +13 ft 0 in
≔L =++A B C 41 ft
Enter Trib Width:≔s +5 ft 9 in
Enter (E) Loads:≔DL 20 psf ≔LR 20 psf
≔W DL LR
[[]]
Loads in plf:≔w =⋅W s 115 115[[]]plf
Total Load:=∑w 230 plf
Load from Unit:≔P =⋅―――1000 lbf
2 ―1
2 0.25 kip
See attached enercalc printout for moment and shear values
≔M 46.504 ft·kip ≔V 4.625 kip
Equivalent Uniform Load:≔weq =―――((⋅M 8))
L2 221.316 plf
Existing 28K(260/144) Joist O.K.
JOB NO: 8116
11
General Beam
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Joist at RTU 4
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 30 NOV 2021, 5:23PM
Project Descr:Carmel, IN
General Beam Properties
Elastic Modulus ksi29,000.0
100.0Span #1 in^4Area = in^2 Moment of Inertia =Span Length =10.041.0 ft
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Uniform Load : D = 0.1150 k/ft, Tributary Width = 1.0 ft
Uniform Load : Lr = 0.1150 k/ft, Extent = 0.0 -->> 21.670 ft, Tributary Width = 1.0 ft
Uniform Load : Lr = 0.1150 k/ft, Extent = 28.0 -->> 41.0 ft, Tributary Width = 1.0 ft
Point Load : D = 0.250 k @ 21.670 ft
Point Load : D = 0.250 k @ 28.0 ft
.DESIGN SUMMARY
Maximum Bending =
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 20.090 ft
4.625 k
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination +D+Lr
Maximum Shear =
0.000 ft
46.504 k-ft
Maximum Deflection
Max Downward Transient Deflection 1.960 in 251
Max Upward Transient Deflection 0.032 in 15537
Max Downward Total Deflection 4.893 in 100
Max Upward Total Deflection 0.028 in 17858
12
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Joist at Hung Ceiling -
Enter Length:≔L +41 ft 0 in
Enter Trib Width:≔s +5 ft 9 in
Enter (E) Loads:≔DL 20 psf ≔LR 20 psf
≔W DL LR[[]]
Loads in plf:≔w =⋅W s 115 115[[]]plf
Total Load:=∑w 230 plf
Load from ceiling (Acting at
8'-0" O.C.):
≔P =⋅⋅5 psf 8 ft 8 ft 0.32 kip
See attached enercalc printout for moment and shear values
≔M 56.489 ft·kip ≔V 5.652 kip
Equivalent Uniform Load:≔weq =―――((⋅M 8))
L2 268.835 plf
Increase in load:=―――weq
260 plf 1.034 (3.4% Increase < 5%)
Existing 28K(260/144) Joist O.K.
JOB NO: 8116
13
General Beam
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Joist at Ceiling
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 30 NOV 2021, 5:29PM
Project Descr:Carmel, IN
General Beam Properties
Elastic Modulus ksi29,000.0
100.0Span #1 in^4Area = in^2 Moment of Inertia =Span Length =10.041.0 ft
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Loads on all spans...
Point Load : D = 0.320 k, Starting at : 0.0 ft and placed every 8.0 ft thereafter
Uniform Load : D = 0.1150, Lr = 0.1150 k/ft, Tributary Width = 1.0 ft
.DESIGN SUMMARY
Maximum Bending =
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 20.500 ft
5.652 k
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination +D+Lr
Maximum Shear =
41.000 ft
56.489 k-ft
Maximum Deflection
Max Downward Transient Deflection 2.541 in 193
Max Upward Transient Deflection 0.040 in 12196
Max Downward Total Deflection 5.948 in 82
Max Upward Total Deflection 0.032 in 15198
14
15
16
17
18
19
20
21
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Hood Support Analysis:
Max. Weight of hood - ≔W 1050 lbf
Threaded rod analysis -
No of rods used:≔n 4
Tension in each rod:≔T =―W
n 262.5 lbf
Use 1/2" Threaded rod at each corner of the hood
≔Tallowable =⋅⋅0.6 36 ksi 0.2 in2 4.32 kip ( > T, O.K)
(Connect rods to steel angle at roof)
Steel Roof Angle at Hood -
Length:≔l +6 ft 0 in
≔P =―W
2 525 lbf (Consider this load at mid
span, worstcase)
Use L5x5x5/16 Steel angle
(See attached enercalc printout)
JOB NO: 8116
22
Steel Beam
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Hood Support
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 30 NOV 2021, 5:36PM
Project Descr:Carmel, IN
CODE REFERENCES
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
Analysis Method :
ksi
Bending Axis :Major Axis Bending
Completely Unbraced
Allowable Strength Design Fy : Steel Yield :36.0 ksi
Beam Bracing :E: Modulus :29,000.0
Vertical Leg Up
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Beam self weight calculated and added to loading
Load(s) for Span Number 1
Point Load : D = 0.5250 k @ 3.0 ft
.Design OKDESIGN SUMMARY
Maximum Bending Stress Ratio =0.209: 1
Load Combination D Only
Span # where maximum occurs Span # 1
Location of maximum on span 3.000ft
0.2934 k
Mn / Omega : Allowable 3.987 k-ft Vn/Omega : Allowable
L5x5x5/16Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination D Only
20.242 k
Section used for this span L5x5x5/16
Ma : Applied
Maximum Shear Stress Ratio =0.014 : 1
0.000 ft
0.834 k-ft Va : Applied
0 <360
3529
Ratio =0 <180
Maximum Deflection
Max Downward Transient Deflection 0.000 in 0Ratio =<360
Max Upward Transient Deflection 0.000 in Ratio =
Max Downward Total Deflection 0.020 in Ratio =>=180Max Upward Total Deflection 0.000 in
.
Load Combination Support 1 Support 2
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Overall MAXimum 0.293 0.293
Overall MINimum 0.176 0.176
D Only 0.293 0.293
+0.60D 0.176 0.176
23
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Hung Ceiling Analysis:
Weight of ceiling:≔WDL 5 psf
Metal Stud supporting ceiling -
Length:≔L +8 ft 0 in
Trib Width:≔s +2 ft 0 in
Uniform Load:≔w =⋅WDL s 10 plf
Use 600S162-43 @ 24" o.c
(See Simpson CFS Designer Printout)
Threaded rod analysis -
Tension in each rod:≔T =⋅⋅8 ft 8 ft 5 psf 320 lbf
Use 1/2" Threaded rod at each corner
≔Tallowable =⋅⋅0.6 36 ksi 0.2 in2 4.32 kip ( > T, O.K)
(Connect rods to steel angle at roof)
(4) #9 wires are splayed in different directions at each rod.
Tension in each wire:≔Twire =―T
4 80 lbf
Tensile capacity of #9 wire:≔Tallowable =⋅⋅⋅40000 psi 0.6 ―4 ((0.147 in))
2 407.32 lbf
#9 wires O.K
Steel Roof Angle -
Length:≔l +6 ft 0 in
≔P =T 320 lbf (Consider this load at mid
span, worstcase)
Use L4x4x1/4 Steel angle
(See attached enercalc printout)
JOB NO: 8116
24
25
Steel Beam
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Support
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 30 NOV 2021, 5:38PM
Project Descr:Carmel, IN
CODE REFERENCES
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : IBC 2018
Material Properties
Analysis Method :
ksi
Bending Axis :Major Axis Bending
Completely Unbraced
Allowable Strength Design Fy : Steel Yield :36.0 ksi
Beam Bracing :E: Modulus :29,000.0
Vertical Leg Up
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Beam self weight calculated and added to loading
Load(s) for Span Number 1
Point Load : D = 0.320 k @ 3.0 ft
.Design OKDESIGN SUMMARY
Maximum Bending Stress Ratio =0.256: 1
Load Combination D Only
Span # where maximum occurs Span # 1
Location of maximum on span 3.000ft
0.1798 k
Mn / Omega : Allowable 1.991 k-ft Vn/Omega : Allowable
L4x4x1/4Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1
Load Combination D Only
12.934 k
Section used for this span L4x4x1/4
Ma : Applied
Maximum Shear Stress Ratio =0.014 : 1
0.000 ft
0.510 k-ft Va : Applied
0 <360
2327
Ratio =0 <180
Maximum Deflection
Max Downward Transient Deflection 0.000 in 0Ratio =<360
Max Upward Transient Deflection 0.000 in Ratio =
Max Downward Total Deflection 0.031 in Ratio =>=180Max Upward Total Deflection 0.000 in
.
Load Combination Support 1 Support 2
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Overall MAXimum 0.180 0.180
Overall MINimum 0.108 0.108
D Only 0.180 0.180
+0.60D 0.108 0.108
26
DESIGNED BY: BG DATE:
CHECKED BY: DATE:
CLIENT: BRR
JOB TITLE: THE FRESH MARKET, CARMEL, IN
11/30/2021
Trash Enclosure Screen Wall -
Enter Wall Height: ≔h +10 ft 0 in with 2'-0" of retaining
Wind Load:≔W =⋅23.6 psf 0.6 14.16 psf
Use 8" CMU wall w/#5 bars @ 32" o.c, with 3'-0" wide footing
w/ (3) #5 Long
(See attached enercalc printout)
Cart Carol Front -
Enter Wall Height: ≔h +6 ft 3 in with 2'-0" of retaining
Wind Load:≔W =⋅23.6 psf 0.6 14.16 psf
Use 8" concrete wall w/#5 bars @ 32" o.c, with 2'-0" wide footing w/
(3) #5 Continuous
(See attached enercalc printout)
JOB NO: 8116
27
Cantilevered Retaining Wall
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Trash Enclosure wall
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 26 NOV 2021, 5:14PM
Project Descr:Carmel, IN
Calculations per ACI 318-14, TMS 402-16, IBC 2018,
CBC 2019, ASCE 7-162.00
8.00
0.00
24.00
1,500.0
45.0
0.0
30.0 psf/ft
250.0
Criteria Soil Data
Retained Height = ft
Wall height above soil = ft
Heel Active Pressure = psf/ft: 1Slope Behind Wall
Height of Soil over Toe
=
in
Water height over heel = ft
pcf
pcf= 110.00
=
110.00
=
Soil Density, Heel
Toe Active Pressure =
Passive Pressure = psf/ft
Allow Soil Bearing = psf
Soil Density, Toe
Soil height to ignore
Friction Coeff btwn Ftg & Soil = 0.400
Vertical component of active
Lateral soil pressure options:
NOT USED for Soil Pressure.
NOT USED for Sliding Resistance.
NOT USED for Overturning Resistance.for passive pressure = 12.00 in
Equivalent Fluid Pressure Method
Surcharge Loads Adjacent Footing Load
0.0 Lateral Load = 0.0 plf
0.0
0.0
0.0
0.0
Axial Load Applied to Stem
Wall to Ftg CL Dist = 0.00 ft
Wind on Exposed Stem psf14.2=
Lateral Load Applied to Stem
Surcharge Over Heel =psf Adjacent Footing Load = 0.0 lbs
Axial Dead Load =lbs
Footing Type Line Load
Surcharge Over Toe psf
Footing Width = 0.00 ft
...Height to Top = 0.00 ft
Eccentricity = 0.00 in...Height to Bottom = 0.00 ft
Used To Resist Sliding & Overturning
Used for Sliding & Overturning
= 0.0 ft
Axial Live Load =
Base Above/Below Soil
lbs
=
Axial Load Eccentricity ==Poisson's Ratio 0.300
at Back of Wall
in
Design Summary
Wall Stability Ratios
Overturning =2.64 OK
Sliding =8.88 OK
Total Bearing Load = 1,513 lbs
...resultant ecc. = 6.82 in
Soil Pressure @ Toe = 1,083 psf OK
Soil Pressure @ Heel = 0 psf OK
Allowable =1,500 psfSoil Pressure Less Than Allowable
ACI Factored @ Toe = 1,300 psf
ACI Factored @ Heel = 0 psf
Footing Shear @ Toe = 5.7 psi OK
Footing Shear @ Heel = 4.5 psi OK
Allowable = 75.0 psi
Sliding Calcs (Vertical Component NOT Used)
Lateral Sliding Force =180.8 lbs
less 100% Passive Force
less 100% Friction Force
Added Force Req'd
....for 1.5 : 1 Stability =
0.0=
605.30.0
1,000.0
=
=
0.0
-
lbs
lbs
lbs OK
lbs OK
-
Masonry Block Type = 2
Stem Construction Top Stem
Stem OK
Design Height Above Ftg =0.00ft
Wall Material Above "Ht" = Masonry
Thickness =8.00in
Rebar Size = # 5
Rebar Spacing = 32.00in
Rebar Placed at =Center
Design Data
fb/FB + fa/Fa =
0.598
Total Force @ Section = 229.2lbs
Moment....Actual = 1,119.5ft-l
Moment.....Allowable = 1,872.3ft-l
Shear.....Actual = 5.1psi
Shear.....Allowable = 80.5psi
Lap splice if above = 45.00in
7.00in
Hook embed into footing 7.00=in
Wall Weight = 55.0
Lap splice if below =
psf
Rebar Depth 'd' = 3.75in
Masonry Data
f'm = 2,000psi
Fy =psi 60,000
Solid Grouting = No
Modular Ratio 'n'= 16.11
Short Term Factor = 1.000
Equiv. Solid Thick.=4.90in
Masonry Design Method LRFD=
Load Factors
Dead Load 1.200
Live Load 1.600
Earth, H 1.600
Wind, W 1.600
Seismic, E 1.000
28
Cantilevered Retaining Wall
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Trash Enclosure wall
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 26 NOV 2021, 5:14PM
Project Descr:Carmel, IN
1.17
1.83
12.00
0.00
0.00
=Min. As % 0.0018
Footing Dimensions & Strengths
f'c = 2,500psi
Toe Width = ft
Heel Width =
Key Distance from Toe
Key Depth
Key Width = in
= in
= 0.00
Footing Thickness = in
3.00=
ft
Cover @ Top =2.00 in@ Btm.= 3.00 in
Total Footing Width
= 150.00pcfFooting Concrete Density
Fy = 60,000 psi
Footing Design Results
Key:
=
No key defined
Factored Pressure
Mu' : Upward
Mu' : Downward
Mu: Design
Actual 1-Way Shear
Allow 1-Way Shear
Toe: Not req'd, Mu < S * Fr
Not req'd, Mu < S * Fr
= None Spec'd
=
=
=
=
=
1,300
972
395
577
5.68
75.00
Heel:
0
0
395
395
4.54
75.00
HeelToe
psf
ft-lb
ft-lb
ft-lb
psi
psi
Heel Reinforcing = # 6 @ 16.00 in
Other Acceptable Sizes & Spacings
Key Reinforcing
Toe Reinforcing = # 7 @ 16.00 in
Summary of Overturning & Resisting Forces & Moments
.....RESISTING..........OVERTURNING.....
Force Distance Moment Distance Moment
Item
Force
Soil Over Heel
ft-lb
202.5 256.7
lbs
202.5
-135.0Toe Active Pressure
1.00 2.42
ftft
620.3=Heel Active Pressure
ft-lblbs
Sloped Soil Over Heel
=
=Surcharge over Heel =
Surcharge Over Heel
=
=
Adjacent Footing Load
=Adjacent Footing Load
Axial Dead Load on Stem =
=* Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Surcharge Over Toe
Load @ Stem Above Soil = 113.3 7.00 793.0
=
=
1.00 -135.0
256.7 0.58 149.7=
=
=
Stem Weight(s)
=
550.0 1.50 825.0
Earth @ Stem Transitions
=Footing Weight
=
450.0 1.50 675.0
Key Weight
=Added Lateral Load
lbs
=860.5
Vert. Component
Total
=
1,513.3 2,270.0
* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation.
Total = R.M.
=180.8 O.T.M.
=
Resisting/Overturning Ratio =2.64
Vertical Loads used for Soil Pressure = 1,513.3 lbs
29
Cantilevered Retaining Wall
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Cart Carol wall
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 26 NOV 2021, 5:15PM
Project Descr:Carmel, IN
Calculations per ACI 318-14, TMS 402-16, IBC 2018,
CBC 2019, ASCE 7-162.00
4.25
0.00
24.00
1,500.0
45.0
0.0
30.0 psf/ft
250.0
Criteria Soil Data
Retained Height = ft
Wall height above soil = ft
Heel Active Pressure = psf/ft: 1Slope Behind Wall
Height of Soil over Toe
=
in
Water height over heel = ft
pcf
pcf= 110.00
=
110.00
=
Soil Density, Heel
Toe Active Pressure =
Passive Pressure = psf/ft
Allow Soil Bearing = psf
Soil Density, Toe
Soil height to ignore
Friction Coeff btwn Ftg & Soil = 0.400
Vertical component of active
Lateral soil pressure options:
NOT USED for Soil Pressure.
NOT USED for Sliding Resistance.
NOT USED for Overturning Resistance.for passive pressure = 12.00 in
Equivalent Fluid Pressure Method
Surcharge Loads Adjacent Footing Load
0.0 Lateral Load = 0.0 plf
0.0
0.0
0.0
0.0
Axial Load Applied to Stem
Wall to Ftg CL Dist = 0.00 ft
Wind on Exposed Stem psf14.2=
Lateral Load Applied to Stem
Surcharge Over Heel =psf Adjacent Footing Load = 0.0 lbs
Axial Dead Load =lbs
Footing Type Line Load
Surcharge Over Toe psf
Footing Width = 0.00 ft
...Height to Top = 0.00 ft
Eccentricity = 0.00 in...Height to Bottom = 0.00 ft
Used To Resist Sliding & Overturning
Used for Sliding & Overturning
= 0.0 ft
Axial Live Load =
Base Above/Below Soil
lbs
=
Axial Load Eccentricity ==Poisson's Ratio 0.300
at Back of Wall
in
Design Summary
Wall Stability Ratios
Overturning =2.49 OK
Sliding =10.77 OK
Total Bearing Load = 937 lbs
...resultant ecc. = 4.81 in
Soil Pressure @ Toe = 1,043 psf OK
Soil Pressure @ Heel = 0 psf OK
Allowable =1,500 psfSoil Pressure Less Than Allowable
ACI Factored @ Toe = 1,252 psf
ACI Factored @ Heel = 0 psf
Footing Shear @ Toe = 3.2 psi OK
Footing Shear @ Heel = 2.6 psi OK
Allowable = 75.0 psi
Sliding Calcs (Vertical Component NOT Used)
Lateral Sliding Force =127.7 lbs
less 100% Passive Force
less 100% Friction Force
Added Force Req'd
....for 1.5 : 1 Stability =
0.0=
374.80.0
1,000.0
=
=
0.0
-
lbs
lbs
lbs OK
lbs OK
-
Masonry Block Type = 2
Stem Construction Top Stem
Stem OK
Design Height Above Ftg =0.00ft
Wall Material Above "Ht" = Masonry
Thickness =8.00in
Rebar Size = # 5
Rebar Spacing = 32.00in
Rebar Placed at =Center
Design Data
fb/FB + fa/Fa =
0.229
Total Force @ Section = 144.3lbs
Moment....Actual = 429.2ft-l
Moment.....Allowable = 1,872.3ft-l
Shear.....Actual = 3.2psi
Shear.....Allowable = 80.5psi
Lap splice if above = 45.00in
7.00in
Hook embed into footing 7.00=in
Wall Weight = 55.0
Lap splice if below =
psf
Rebar Depth 'd' = 3.75in
Masonry Data
f'm = 2,000psi
Fy =psi 60,000
Solid Grouting = No
Modular Ratio 'n'= 16.11
Short Term Factor = 1.000
Equiv. Solid Thick.=4.90in
Masonry Design Method LRFD=
Load Factors
Dead Load 1.200
Live Load 1.600
Earth, H 1.600
Wind, W 1.600
Seismic, E 1.000
30
Cantilevered Retaining Wall
A.V. SCHWAN & ASSOCIATES, INC.Lic. # : KW-06000020
DESCRIPTION:Cart Carol wall
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17
File: 8116.ec6
Project Title:The Fresh Market
Engineer:BG
Project ID:8116
Printed: 26 NOV 2021, 5:15PM
Project Descr:Carmel, IN
0.67
1.33
12.00
0.00
0.00
=Min. As % 0.0018
Footing Dimensions & Strengths
f'c = 2,500psi
Toe Width = ft
Heel Width =
Key Distance from Toe
Key Depth
Key Width = in
= in
= 0.00
Footing Thickness = in
2.00=
ft
Cover @ Top =2.00 in@ Btm.= 3.00 in
Total Footing Width
= 150.00pcfFooting Concrete Density
Fy = 60,000 psi
Footing Design Results
Key:
=
No key defined
Factored Pressure
Mu' : Upward
Mu' : Downward
Mu: Design
Actual 1-Way Shear
Allow 1-Way Shear
Toe: Not req'd, Mu < S * Fr
Not req'd, Mu < S * Fr
= None Spec'd
=
=
=
=
=
1,252
367
154
213
3.19
75.00
Heel:
0
0
154
154
2.60
75.00
HeelToe
psf
ft-lb
ft-lb
ft-lb
psi
psi
Heel Reinforcing = # 6 @ 16.00 in
Other Acceptable Sizes & Spacings
Key Reinforcing
Toe Reinforcing = # 7 @ 16.00 in
Summary of Overturning & Resisting Forces & Moments
.....RESISTING..........OVERTURNING.....
Force Distance Moment Distance Moment
Item
Force
Soil Over Heel
ft-lb
202.5 146.7
lbs
202.5
-135.0Toe Active Pressure
1.00 1.67
ftft
244.4=Heel Active Pressure
ft-lblbs
Sloped Soil Over Heel
=
=Surcharge over Heel =
Surcharge Over Heel
=
=
Adjacent Footing Load
=Adjacent Footing Load
Axial Dead Load on Stem =
=* Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Surcharge Over Toe
Load @ Stem Above Soil = 60.2 5.13 308.4
=
=
1.00 -135.0
146.7 0.33 48.9=
=
=
Stem Weight(s)
=
343.8 1.00 343.8
Earth @ Stem Transitions
=Footing Weight
=
300.0 1.00 300.0
Key Weight
=Added Lateral Load
lbs
=375.9
Vert. Component
Total
=
937.1 937.1
* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation.
Total = R.M.
=127.7 O.T.M.
=
Resisting/Overturning Ratio =2.49
Vertical Loads used for Soil Pressure = 937.1 lbs
31