ESR-3851_September2022 11930 Hoster Road
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4 ICC-ES Evaluation Report ESR-3851 Reissued September 2020 Revised January 2021 This report is subject to renewal September 2022. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: CRAWL SPACE DOOR SYSTEMS, INC. EVALUATION SUBJECT: CRAWL SPACE DOOR SYSTEMS FLOOD VENT MODEL #CSBA816 CRAWL SPACE STACKED MODELS: #ICCSTACKED2; #ICCSTACKED4 FLOOD VENT INSULATED KIT #ICCINSULATED 1.0 EVALUATION SCOPE Compliance with the following codes: 2018 and 2015 International Building Code® 2018 and 2015 International Residential Code® Properties evaluated: Physical operation Water flow Weathering 2.0 USES Crawl Space Door Systems flood vents are used to provide for the equalization of hydrostatic flood forces on exterior walls. 3.0 DESCRIPTIONs 3.1 General: Crawl Space Door Systems flood vents are engineered mechanically operated flood vents. Upon contact with flood water, the flood vents automatically open and allow flood water to enter and exit enclosed areas. The vents are constructed of general purpose ABS SP-9010 plastic. The Crawl Space Flood Vent Model #CSBA816 has a faux louver with either a solid plastic plate or wire mesh attached to the back of the louver. The louver is dislodged from the vent upon contact with flood waters. See Figure 1 for an illustration of the flood vent Model #CSBA816. The Flood Vent Insulated Kit Model #ICCINSULATED is constructed of general purpose ABS SP-9010 plastic. The vent frame opening is filled with a 2-inch thick (51 mm) extruded polystyrene Styrofoam™ Brand Scoreboard Foam Insulation Board (ESR-2142). The insulation board is dislodged from the vent upon contact with flood waters, allowing flood waters to enter and exit enclosed areas. See Figure 2 for an illustration of the Flood Vent Insulated Kit Model #ICCINSULATED. The Crawl Space Stacked Model #ICCSTACKED2 contains two vertically arranged Crawl Space Flood Vents (Model #CSBA816) in one assembly. The Crawl Space Stacked Model #ICCSTACKED4 contains four Crawl Space Flood Vents (Model #CSBA816) in one assembly, with two sets of side by side flood vents vertically arranged. 3.2 Engineered Opening: The Crawl Space Door Systems static flood vents comply with the design principle noted in Section 2.7.2.2 of ASCE/SEI 24 for a rate of rise and fall of 5 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24-14, the flood vents must be installed in accordance with Section 4.0 of this report. 3.3 Ventilation: The Crawl Space Flood Vent Model #CSBA816 and Crawl Space Stacked Models #ICCSTACKED2 and #ICCSTACKED4 are available covered with metal wire mesh with 0.108 inch by 0.108 inch (2.74 mm by 2.74 mm) openings. The mesh is covered by a faux louver with 11/16 inch (17.5 mm) vertical clearance between each blade. The Crawl Space Flood Vent Model #CSBA816 provides 11 square inches (7097 mm2) of net free area to supply natural ventilation when equipped with wire mesh. The Crawl Space Stacked Models #ICCSTACKED2 and #ICCSTACKED4 supply 22 square inches (14,194 mm2) and 44 square inches (28,388 mm2), respectively, of net free area to supply natural ventilation when equipped with wire mesh. The Crawl Space Flood Vent Model #CSBA816 covered with a solid plastic plate, Crawl Space Stacked Models #ICCSTACKED2 and #ICCSTACKED4 covered with a solid plastic plate, and the Flood Vent Insulated Kit Model #ICCINSULATED do not offer natural ventilation. 4.0 DESIGN AND INSTALLATION The Crawl Space Door Systems flood vents are designed to be installed into walls or doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer’s instructions, the applicable code and this report. In order to comply with the engineered opening design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14, the vent must be installed as follows: With a minimum of two openings; one on different sides of each enclosed area. 02/08/22 ESR-3851 | Most Widely Accepted and Trusted Page 2 of 4 With a minimum of one vent for the square footage of enclosed area noted in Table 1. Below the base flood elevation. With the bottom of the vent located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The Crawl Space Door Systems flood vents described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Crawl Space Door Systems flood vents must be installed in accordance with this report, the applicable code and the manufacturer’s published installation instructions. In the event of a conflict, the instructions in this report govern. 5.2 The Crawl Space Door Systems flood vents must not be used in the place of “breakaway walls” in coastal high hazard areas but are permitted for use in conjunction with breakaway walls in other areas. 5.3 The Crawl Space Door Systems flood vents are manufactured under a quality control system with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (Editorially revised October 2017). 7.0 IDENTIFICATION 7.1 The Crawl Space Door Systems flood vents recognized in this report must be identified by a label bearing the manufacturer’s name (Crawl Space Door Systems), the model number, and the evaluation report number (ESR-3851). 7.2 The report holder’s contact information is the following: CRAWL SPACE DOOR SYSTEMS, INC. 3669 SEA GULL BLUFF DRIVE VIRGINIA BEACH, VIRGINIA 23455 (757) 363-0005 www.crawlspacedoors.com TABLE 1—CRAWL SPACE DOOR SYSTEMS FLOOD VENTS MODEL OVERALL VENT SIZE (Width x Height x Depth) (in) ROUGH OPENING SIZE (Width x Height) (in) ENCLOSED AREA COVERAGE (ft2) CSBA816 181/ 4 x 10 1/2 x 13/4 16 x 81/4 305 ICCINSULATED 181/ 4 x 10 1 /2 x 1 3/4 153/4 x 8 300 ICCSTACKED2 30 x 30 x 23/4 24 x 24 610 ICCSTACKED4 401/ 2 x 24 3/4 x 23/4 351/4 x 191/2 1,220 FIGURE 1—CRAWL SPACE DOOR SYSTEMS FLOOD VENT FIGURE 2—FLOOD VENT INSULATED KIT 02/08/22 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 3 of 4 ICC-ES Evaluation Report ESR-3851 CBC and CRC Supplement Issued September 2020 Revised December 2020 This report is subject to renewal September 2022. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: CRAWL SPACE DOOR SYSTEMS, INC. EVALUATION SUBJECT: CRAWL SPACE DOOR SYSTEMS FLOOD VENT #CSBA816 CRAWL SPACE STACKED MODELS #ICCSTACKED2; #ICCSTACKED4 FLOOD VENT INSULATED KIT #ICCINSULATED 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Crawl Space Door Systems flood vents, described in ICC- ES evaluation report ESR-3851, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2019 California Building Code (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) and Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below. 2019 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Crawl Space Door Systems flood vents, described in Sections 2.0 through 7.0 of the evaluation report ESR-3851, comply with CBC Chapter 12, provided the design and installation are in accordance with the 2018 International Building Code ® (IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapters 12 and 16, as applicable. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The Crawl Space Door Systems flood vents, described in Sections 2.0 through 7.0 of the evaluation report ESR-3851, comply with 2019 CRC, provided the design and installation are in accordance with the 2018 International Residential Code ® (IRC) provisions noted in the evaluation report. This supplement expires concurrently with the evaluation report, reissued September 2020 and revised January 2021. 02/08/22 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 4 of 4 ICC-ES Evaluation Report ESR-3851 FBC and FRC Supplement Reissued September 2020 Revised January 2021 This report is subject to renewal September 2022. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: CRAWL SPACE DOOR SYSTEMS, INC. EVALUATION SUBJECT: CRAWL SPACE DOOR SYSTEMS FLOOD VENT #CSBA816 CRAWL SPACE STACKED MODELS #ICCSTACKED2; #ICCSTACKED4 FLOOD VENT INSULATED KIT #ICCINSULATED 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Crawl Space Door Systems flood vents, described in ICC- ES evaluation report ESR-3851, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2020 Florida Building CodeBuilding 2020 Florida Building CodeResidential 2.0 CONCLUSIONS The Crawl Space Door Systems flood vents, described in Sections 2.0 through 7.0 of ICC-ES evaluation report ESR-3851, comply with the Florida Building CodeBuilding and Florida Building CodeResidential, provided the design requirements are determined in accordance with the Florida Building CodeBuilding and Florida Building CodeResidential, as applicable. The installation requirements noted in ICC-ES evaluation report ESR-3851 for the 2018 International Building Code ® meet the requirements of the he Florida Building CodeBuilding and Florida Building CodeResidential, as applicable. Use of the Crawl Space Door Systems flood vents has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the 2020 Florida Building CodeBuilding and Florida Building CodeResidential. For products falling under Florida Rule 61G20-3, verification that the report holder’s quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report, reissued September 2020 and revised January 2021. 02/08/22