Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A01 - Renovation Drawings V2
FUR. WHWH SOFT SOFT 333UNEX. EGRESS WINDOW + CAGE EJECT SUMP 32x36 3-PIECE SHOWER TO MAIN LEVEL00130/68FAN +LITE SD SD1"3' - 4 1/2"6' - 0 1/2"3' - 5"2' - 10 1/2"1"14' - 5"4 1/2"8' - 2 1/2" 4 1/2" 11' - 5 1/2" 3' - 6" 4' - 0" ROD AND SHELF20/68 28/6828/6816/6817/1 ROUGH OPENING3' - 0" 11' - 0" 3' - 0"3' - 5 1/2"FRAMED OPENING17' - 1"3' - 5 1/2"3' - 4"SAW CUT CONCRETE17' - 4"3' - 4"A00 314" LVL HEADER LENGTH20' - 0"10 A00 NON-BEARING 2X4 FRAMED WALL IN EXISTING OPENING. MATCH SIDING FINISHES RELOCATE EXISTING GARAGE DOOR1' - 4 1/2"1 1/2"FIRST STUD WITHIN SAW CUT CONCRETE OPENING TRIPLE 2X4 UNDER LVL END SUPPORT 2X4 KING STUD BORDERING END OF LVLEXISTING PLATTED ACCESS EASEMENTPROPERTY LINE BORDER WITH 106TH STREET 924 SF CONCRETE TO BE REMOVED 1 2 ' - 0 " 8' - 0 " 1 6 ' - 3 " 17' - 0" R 10' - 0 "R 3' - 0"R 10' - 0"15' - 8"48' - 6"17' - 9"1127 SF CONCRETE TO BE REPLACED LEVEL 01 0' - 0" LEVEL 02 10' - 1 3/4" TOP OF STEM WALL -1' - 4 1/2" 10 A00 NEW 1X4 LP SMART TRIM WALL ASSEMBLY TO REMAIN EXISTING GARAGE DOOR TO BE RELOCATED LEVEL 01 0' -0" LEVEL 02 10' -1 3/4" LEVEL 01 0' -0" LEVEL 02 10' - 1 3/4" TOP OF STEM WALL -1' - 4 1/2"6"NEW LP SMARTSIDE 7" EXPOSURE TO MATCH EXISTING WALL ASSEMBLY TO REMAIN LEVEL 01 0' - 0" LEVEL 02 10' - 1 3/4" TOP OF STEM WALL -1' -4 1/2" 3 12 AA 10' - 1 3/4"1' - 4 1/2"LEVEL 01 0' -0" TOP OF STEM WALL -1' - 4 1/2"1' - 2"7' - 7"5"T.O. HEADER ABOVE STEM WALL8' - 9"SAW CUT CONCRETE DEPTH EXISTING CONCRETE SLAB TO REMAIN EXISTING CONCRETE FOUNDATION TO REMAIN 2-PLY 14" LVL HEADER CONTINUOUS PER PLAN ScaleProject numberDateALL DRAWINGS AND IDEAS COPYRIGHT 2021 SLOAN CONNECTION LLC FOR H/E HOMES. ALL RIGHTS RESERVED. DUPLICATION OFANY KIND TO ANY ENTITY FOR ANY REASON IS PROHIBITED WITHOUT PRIOR WRITTEN CONSENT BY SLOAN CONNECTION LLC OR H/EHOMES. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND NOT INTENDED TO COVER THE FULL SCOPE OF WORK. CONTRACTORWITH ADEQUATE KNOWLEDGE REQUIRED TO TAKE ON PROJECT AND ASSUMES ALL LIABILITY, EXPRESSED OR IMPLIED, FORCOMPLETION OF PROJECT TO ALL APPLICABLE LOCAL CODES AND GUIDELINES AND STANDARDS.As indicatedA00RENO DRAWINGS1828 E 106TH STCUSTOM DESIGNBRINDLEY RENOVATIONJAN. 27, 20221/4" = 1'-0"1 BASEMENT FINISH PLAN 1/4" = 1'-0" 2 LEVEL 01 - PROPOSED GARAGE 1/2" = 1'-0"3 PROPOSED STUD DETAIL 1" = 20'-0"4 SITE PLAN - CURRENT 1" = 20'-0"5 SITE PLAN - REWORK 1/4" = 1'-0"6 SOUTH ELEVATION - PROPOSED 1/4" = 1'-0"7 WEST ELEVATION 1/4" = 1'-0"8 WEST ELEVATION - PROPOSED 1/4" = 1'-0"9 SOUTH ELEVATION 1/2" = 1'-0"10 PROPOSED GARAGE SECTION BASEMENT FINISH PLAN GARAGE DOOR RELOCATION 02/09/22