HomeMy WebLinkAboutCOMcheck Signed GREAT GROWINSCOMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area: Construction Site: 421 S Rangeline Rd Carmel, IN 46032 Building Area 1-Office : Nonresidential Envelope Assemblies Assembly 90.1 (2007) Standard Great Growin's Carmel, Indiana 5a Addition 32% Owner/Agent: Stephanie Miller Great Growin's 421 S. Rangeline Rd Carmel, IN 46032 317-709-7255 steph@greatgrowins.com Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Office] Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Office] Window 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID Pella, SHGC 0.18, [Bldg. Use 1 - Office] (b) Door 1: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Perf Specs.: Product ID Pella, SHGC 0.20, [Bldg. Use 1 - Office] (b) Floor 1: Slab -On -Grade: Unheated, Vertical 2 ft., [Bldg. Use 1 - Office] (c) Designer/Contractor: Stuart Sande SRS Architects, Inc 13245 Allisonville Fishers, IN 46032 317-218-6307 sshade@mitschdesign.com Floor Area 279 Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(.) Perimeter 279 30.0 416 19.0 90 - 42 --- 52 --- 0.0 0.0 0.0 0.034 0.027 0.067 0.064 0.290 0.350 0.290 0.350 0.730 0.730 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab -On -Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in Wis dDcument is consistent with the building plans, specifications, and other calculations submitted with this permit a n he proposed envelope systems have been designed to meet the 90.1 (2007) Standard requirements in CO r ion 4.1.1.0 and to comply with any applicable man atory requirements listed in the Inspection Checklist. LJ't nnigry �� c4 2f Nam -TitleHZA111_ Signatu Dat 5`, �\STegF No. ARQQ034184 1k '. STATE OF Project Title: GreateAr" Data filename: U:\A Arc Report date: 10/08/21 1\2117 Great Growin's Remodel\State\COMcheck.cck Page 1 of 12 Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture ProjectsQ021\2117_Great Growin's Remodel\State\COMcheck.cck Page 2 of 12 n�( COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 421 S Rangeline Rd Carmel, IN 46032 Allowed Exterior Lighting Power A Area/Surface Category 90.1 (2007) Standard Great Growin's Addition Owner/Ayeiii: Stephanie Miller Great Growin's 421 S. Rangeline Rd Carmel, IN 46032 317-709-7255 steph@greatgrowins.com B Quantity Designer/Contractor: Stuart Sande SRS Architects, Inc 13245 Allisonville Fishers, IN 46032 317-218-6307 sshade@mitschdesign.com C D E Allowed Tradable Allowed Watts Watts / Unit Wattage (B X C) Illuminated area'of wall or surface 2760 ft2 0.2 No 552 Total Tradable Watts (a) = 0 Total Allowed Watts = 552 Total Allowed Supplemental Watts (b) = 28 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 28 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Illuminated area of wall 2760 ft2 : Non -tradable Watta le LED 2: LED PAR 16W: LED 4: LED A Lamp 12W: LED 2: LED PAR 16W: 1 10 16 1 2 12 1 2 80 Total Tradable Proposed Watts = 160 24 160 0 Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting designkreprpseis document is consistent with the building plans, specifications, and other calculations submitted with this permproposed exterior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in C.1.1.0 and to comply with any applicable man atory requirements listed in the Inspection Checklist. . /VA 5 Az Na e - Title Signature Data( ,`��1tnrrarupri �p.F.....R:.SHAp''�. ..... G No. z y ; AR00034184 STATE OF i S' /NDIAIA Project Title: Great Growin's rrrrriii,��r�ti��Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Remodel\State\COMcheck.cck Page 4 of 12 n�( COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 421 S Rangeline Rd Carmel, IN 46032 Allowed Interior Lighting Power 90.1 (2007) Standard Great Growin's Addition Owner/Agent: Stephanie Miller Great Growin's 421 S. Rangeline Rd Carmel, IN 46032 317-709-7255 steph@greatgrowins.com A Area Category 1-Common Space Types:Office - Open Plan Proposed Interior Lighting Power A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast 1-Common Space Types:Offi0a - Open Plan LED 2: LED PAR 16W: LED 6: LED Linear 33W: Designer/Contractor: Stuart Sande SRS Architects, Inc 13245 Allisonville Fishers, IN 46032 317-218-6307 sshade@mitschdesign.com B C D Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B X C) 279 1.10 307 Total Allowed Watts = 307 B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 12 16 192 8 1 8 Total Proposed Watts = 200 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design re re d i his document is consistent with the building plans, specifications, and other calculations submitted with this permi a atio . The proposed interior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in C r ck rsion 4.1.1.0 and to comply with any applicable mand tory requirements listed in the Inspection Checklist. Name Title Signature Date 6,eeeunrrrrpr ti111%PR.... R:.Sygp''% CO r r+•Q • AR00034184 i -� ti STATE OF 4 d �NDIAJ qR, uHr`T►Gs``��� Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Rem odel\State\COMcheck. cck Page 3 of 12 COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 90.1 (2007) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Ix Reg.lD 4.2.2 [PR1]1 4.2.2 [PR4]1 Plan Review I Complies? Comments/Assumptions ,Plans and/or specifications provide all ;❑Complies Requirement will be met. information with which compliance T]Does Not can be determined for the building E❑Not Observable envelope and document where exceptions to the standard are :❑Not Applicable ;claimed. Plans, specifications, and/or ;❑Complies :Requirement will be met. :calculations provide all information :❑Does Not ;with which compliance can be ;❑Not Observable i determined for the lighting and electrical systems and equipment and ❑Not Applicable ; document where exceptions to the standard are claimed. Information j provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. 8.4.1.1, Plans, specifications, and/or 8.4.1.2 calculations provide all information [PR6]2 with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Additional Comments/Assumptions: ;❑Complies :Requirement will be met. ❑Does Not '[:]Not Observable ❑Not Applicable 1 1 1 High Impact (Tier 1) 7 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Remodel\state\COMcheck. cck Page 5 of 12 Footing / Foundation & Req.ID Inspection 5.5.3.3 Below -grade wall insulation R- [FO1]1 ;value. Plans Verified Field Verified Complies? Comments/Assumptions Value Value R- R- ElComplies See the Envelope Assemblies ❑Does Not ;table for values. 5.5.3.5 ;Slab edge insulation R-value. R- [F03]1 ❑ Unheated ❑ Heated 5.8.1.2 ;Slab edge insulation installed per [F04]1 Imanufacturer's instructions. 5.5.3.5 Slab edge insulation ft [F05]1 depth/length. 5.8.1.7.3 Insulation in contact with the [F07]1 ground has <=0.3% water absorption rate per ASTM C272. Additional Comments/Assumptions: R- ❑ Unheate ❑ Heated ft ❑Not Observable ❑Not Applicable ❑Complies See the Envelope Assemblies d ❑Does Not ; table for values. ❑Nat Observable ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable t❑Complies ;See the Envelope Assemblies ❑Does Not :table for values. ❑Not Observable ❑Not Applicable ❑Complies I Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact (Tier 1) 2 � Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Remodel\State\COMcheck.cck Page 6 of 12 & Req.ID 5.4.3.2 [FRl]3 Framing i Rough -In Inspection plans Verified Field Verified Value Value Comments/Assumptions Factory -built fenestration and Fenestration_ Fenestration_ °s❑Complies ; Requirement will be met. doors are labeled as meeting air _ cfm/ftz _ cfm/ftz ❑Does Not leakage requirements. Doors Doors cfm/ftz cfm/ftz ![:]Not Observable '❑Not Applicable 5.5.4.3a ;Vertical fenestration U-Factor. ; U- [FR8]1 — 5.5.4.3b Skylight fenestration U-Factor. U-_ [FR9]1 ; ; 5.5.4.4.1 ;Vertical fenestration SHGC value. SHGC: [FR10]1 5.5.4.4.2 Skylight SHGC value. SHGC: [FRll]1 5.8.2.1, Fenestration products rated in 5.8.2.4 accordance with NFRC. [FR12]z Fenestration products are certified as to performance labels or certificates provided. U- ;❑Complies ;See the Envelope Assemblies ❑Does Not table for values. ;❑Not Observable ❑Not Applicable U- ;❑Complies See the Envelope Assemblies r❑Does Not table for values. ;❑Not Observable e❑Not Applicable SHGC: ;❑Complies :See the Envelope Assemblies °❑Does Not ;table for values. ; '❑Not Observable ' ❑Not Applicable SHGC: ;❑Complies ;See the Envelope Assemblies ❑Does Not ; table for values. ;❑Not Observable ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not []Not Observable ❑Not Applicable 5.8.2.3, U factor of opaque doors U- U- �;❑Complies ;See the Envelope Assemblies 5.5.3.6 associated with the building ❑ Swinging ❑ Swinging ;❑Does Not table for values. [FR14]2 thermal envelope meets ❑ Nonswinging ❑ Nonswinging ❑Not Observable requirements. ❑Not Applicable Additional Comments/Assumptions: 1 [ High Impact (Tier 1) 2 j Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Remodel\State\COMcheck.cck Page 7 of 12 Section # Rough -In Electrical Inspection Complies? CommentslAssumptions & Req.ID 9.4.1.1 Automatic controls to shut off all ❑Complies Requirement will be met. [EL1]2 building lighting installed in buildings '❑Does Not >5,000 ft2. ❑Not Observable ❑Not Applicable 9.4,1,2 Independent lighting controls installed .❑Complies Requirement will be met. [EL2]2 per approved lighting plans and all ❑Does Not manual controls readily accessible and ❑Not Observable; visible to occupants. ❑Not Applicable 9.4.1.3 Automatic lighting controls for exterior ❑Complies Requirement will be met, [EL3]2 lighting installed. ❑Does Not ❑Not Observable: ❑Not Applicable 9.4.1.4 Separate lighting control devices for ❑Complies lRequirement will be met. [EL4]1 specific uses installed per approved =❑Does Not lighting plans. I❑Not Observable ❑Not Applicable 9.4.2 Ballasted one and three lamp fixtures `❑Complies ;Requirement will be met. Y [EL5]3 with >30 W/lamp have two lamp '❑Does Not tandem wired ballasts when >=2 ❑Not Observable; fixtures in same space on same ❑Not Applicable control. 9.4.3 Exit signs do not exceed 5 watts per ;❑Complies Requirement will be met. [EL6]1 ;face. ❑Does Not ❑Not Observable I ❑Not Applicable 9.4.4 Exterior grounds lighting over 100 W i❑Complies ;Requirement will be met. [EL7]1 :provides >60 Im/W unless on motion j❑Does Not sensor or fixture is exempt from scope; of code or from external LPD. ❑Not Observable ❑Not Applicable 9.6.2 Additional interior lighting power ❑Complies ; Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not ,approved lighting plans and is ,automatically controlled and ❑Not Observable; '❑Not Applicable separated from general lighting. Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Rem ode l\State\COM check. cck Page 8 of 12 5.4.3.1 [IN1]1 5.5.3.1 [IN2]1 5.8.1.2, 5.8.1.3 [IN3]1 5.5.3.1.1 [IN5]3 ns Insulation inspection l Pia Valuefied Field luefied i Complies? Comments/Assumptions ;All sources of air leakage in the building thermal envelope are ;sealed, caulked, gasketed, ,weather stripped or wrapped with moisture vapor -permeable ;wrapping material to minimize air leakage. Roof R-value. For some ceiling R- systems, verification may need to: ❑ Above deck occur during Framing Inspection. ; ❑ Metal ❑ Attic 1 ; I I I 1 Roof insulation installed per manufacturer's instructions. Blown or poured loose -fill insulation is installed only where the ceiling slope is <= 3:12. High-albedo roofs meet solar SR. reflectance of 0.70 and thermal SRI: emittance of 0.75 or SRI of 82. 5.5.3.2 ;Above -grade wall insulation R- R- [IN6]1 :value. ❑ Mass ❑ Metal ❑ Steel I ❑ Wood I 5.8.1.2 ;Above -grade wall insulation [IN7]1 :installed per manufacturer's instructions. I 5.5.3.4 Floor insulation R-value. R- [IN8]1 ❑ Mass ❑ Steel ❑ Wood 5.8.1.1 Building envelope insulation is [IN10]z labeled with R-value or insulation certificate providing R-value and other relevant data. 5.8.1.4 Eaves are baffled to deflect air to E [IN11]2 above the insulation. 5.8.1.5 Insulation is installed in [IN12]2 substantial contact with the inside surface separating conditioned space from unconditional space. 5.8.1.6 Recessed equipment installed in [IN13]2 building envelope assemblies does not compress the adjacent insulation. ❑Complies :Requirement will be met. ❑Does Not ❑Not Observable ' ❑Not Applicable R- ;❑Complies ;See the Envelope Assemblies ❑ Above deck ;❑Does Not ;table for values. 1 ❑ Metal ;❑Not Observable ❑ Attic ;❑Not Applicable - ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable 5R: ;❑Complies Requirement will be met. SRI: '❑Does Not '❑Not Observable ❑Not Applicable R- ;❑Complies ;See the Envelope Assemblies ❑ Mass ;❑Does Not ;table for values. ❑ Metal ;❑Not Observable I ❑ Steel :❑Not Applicable ❑ Wood ❑Complies ;Requirement will be met. ❑Does Not ❑Not Observable ; ❑Not Applicable R- ;❑Complies ;See the Envelope Assemblies ❑ Mass '❑Does Not ;table for values. ❑ Steel ;"Not Observable ' ❑ Wood ❑Not Applicable I I I I 1 ❑Complies ; Requirement will be met. ❑Does Not ❑Not Observable ; ❑Not Applicable _ ❑Complies I Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable ^�❑Complies ;Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies :Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable `1 lHigh Impact (Tier 1)2� Medium Impact (Tier 2) _ 3 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Remodel\State\COMcheck. cck Page 9 of 12 Section # Insulation Inspection & Rec;.ID _� 5.8.1.7 Exterior insulation is protected [IN14]2 from damage with a protective material. Verification for exposed , foundation insulation may need to occur during Foundation Inspection. 5.8.1.7.1 Attics and mechanical rooms [IN15]2 have insulation protected where adjacent to attic or equipment access. 5.8.1.7.2 Foundation vents do not interfere [IN16]2 with insulation. 5.8.1.8 Insulation intended to meet the [IN17]3 roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed according Additional Comments/Assumptions: Plans Verified Field Verified Value Value LComplies? —Comments/Assumptions ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable —❑Complies Requirement will be met ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies _ Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact (Tier 1) L2J Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Remodel\State\COMcheck.cck Page 10 of 12 section 5.4.3.3 [Fill' 8.7.1 [F11613 8.7.2 [F11713 Final Inspection I Complies? CommentslAss umptions Meatherseals installed on all loading ;❑Complies ;Requirement will be met. :dock cargo doors in Climate Zones 4- '❑Does Not 8• ;❑Not Observable; ❑Not Applicable Furnished as -built drawings for ;❑Complies Requirement will be met. ,electric power systems within 30 days :❑Does Not :of system acceptance. ; ❑Not Observable ❑Not Applicable Furnished O&M instructions for ;❑Complies Requirement will be met. ,systems and equipment to the ;❑Does Not building owner or designated :❑Not Observable ,representative. ;❑Not Applicable 9.2.2.3 ;Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values. [F1181' :lighting power is consistent with what :❑Does Not is shown on the approved lighting Observable plans, demonstrating proposed watts are less than or equal to allowed ;❑Not ❑Not Applicable watts. 9.4.5 ; Exterior lighting power is consistent ;❑Complies ;See the Exterior Lighting fixture schedule for values. [F1191' with what is shown on the approved T❑Does Not lighting plans, demonstrating ;proposed watts are less than or equal ;❑Not Observable:: to allowed watts. ;❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 Low Impact (Tier 3) Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117—Great Growin's Remodel\State\COMcheck.cck Page 11 of 12 Project Title: Great Growin's Report date: 10/08/21 Data filename: U:\A Architecture Projects\2021\2117_Great Growin's Rem odel\State\COMcheck. cck Page 12 of 12