HomeMy WebLinkAboutG001_LIFE SAFETY PLAN GREAT GROWINSSCALE:13/16" = 1' - 0"LEVEL ONE LIFE SAFETYG001CODE AND LIFESAFETY PLANALL IDEAS, DESIGNS AND PLANS INDICATED ORREPRESENTED BY THESE DRAWINGS ARE OWNEDBY, AND THE PROPERTY OF SRS ARCHITECTS, INC.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLEFOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTSRESERVED, EXCEPT FOR USES EXPRESSLYPERMITTED IN WRITING.SHEET NUMBER:CERTIFICATION:PROJECT :
PROPOSED ADDITION TO
GREAT GROWIN'SREV 1: REV 2: 421 S RANGELINE RD
CARMEL, INDIANA 46032
CONSTRUCTION SET 1_05_22SRS ARCHITECTS200 S RANGELINE RD , #226INCCARMEL, INDIANA 46032PHONE: 317-989-6248E-MAIL : sshade@mitschdesign.comTANNIAR
A
TU
SAE
R
IG TS
R T R.
H
S
STATE OF
E
EDDER E
AID
I TCH C
AR00034184 APPLICABLE CODESCODEDESCRIPTIONCOMPRISED OFGENERAL ADMINISTRATIONRULESGENERAL ADMINISTRATIONRULES (GAR) (UPDATED 8.1.2014)(AMENDED 12.1.2014)675 IAC 12BUILDING CODE(INDIANA AMENDMENTS)2014 INDIANA BUILDING CODE (675IAC 13-2.6)EFFECTIVE DECEMBER 1, 20142012 INTERNATIONALBUILDING CODE 675 IAC 13-2.62014 INDIANA FIRE CODE (IFC)EFFECTIVE DECEMBER 1, 20142012 INDIANA PLUMBING CODE(IPC)EFFECTIVE DECEMBER 24, 20122009 INDIANA ELECTRICAL CODE (IEC)EFFECTIVE AUGUST 26, 20092014 INDIANA MECHANICAL CODE (675IAC 18-1.6) EFFECTIVE DECEMBER 1,20142010 INDIANA ENERGY CONSERVATIONCODE (IECC)EFFECTIVE MAY 7, 2010INDIANA BUILDING REHABILITATIONSTANDARD (GAR)(UPDATED 12.22.06)(REPEALED JUNE 18, 20081998 AMERICAN SOCIETY OFSANITARY ENGINEERS STANDARD10512012 INTERNATIONAL FIRE CODE675 IAC 22-2.52006 INTERNATIONAL PLUMBINGCODE675 IAC 16-1.42008 NFPA 70675 IAC 17-1.82012 INTERNATIONAL MECHANICALCODE675 IAC 18-1.6ASHRAE STANDARD 90.1, 2007675 IAC 19-4675 IAC 12-8675 IAC 16-2FIRE CODE(INDIANA AMENDMENTS)PLUMBING CODE(INDIANA AMENDMENTS)ELECTRICAL CODE(INDIANA AMENDMENTS)MECHANICAL CODE(INDIANA AMENDMENTS)ENERGY CODE(INDIANA AMENDMENTS)BUILDING REHABILITATIONSTANDARD(INDIANA AMENDMENTS)SANITARY CODE(INDIANA AMENDMENTS)ELEVATOR SAFETY CODE2011 INDIANA ELEVATOR SAFETY CODE(IESC)(UPDATED 9-28-11)675 IAC 21 - ANSI / ASMEA17.1, 2007ANSI / ASME A90.1, 2003ANSI / A10.4, 2004ASME / A18.1, 2005CODE ANALYSISEXIST AREACONSTRUCTION TYPEVBOCCUPANCY CLASSIFICATIONM = 9000 SF ALLOWABLEOCCUPANCYEXIT REQUIREMENT(1) EXIT (1015.1 - LESS THAN 50)TRAVEL DISTANCECOMMON PATH OF EGRESS TRAVEL - 75' MAX ALLOWABLEDOOR SWINGDIRECTION OF TRAVEL NOT REQUIREDEXITEXIT
ALLOWABLE AREA - MOST STRINGENTFIRE PROTECTIONNONE - SPRINKLERS NOT REQUIREDOCCUPANCY SEPARATIONNON-SEPARATED OCCUPANCIES1302 SFDOOR HARDWARELEVER LATCHDRINKING FOUNTAINSADA - BOTTLE FILLER PROVIDEDUTILITY SINKPROVIDEDPLUMBING FIXTURESEXISTING PER INDIANA AMENDMENTSM - MERCANTILE B - OFFICESCOVERED PORCHES (UNOCCUPIED) - 77 SQ. FT.2008 INDIANA BUILDING CODECHAPTER 11 - ACCESSIBILITYICC STANDARD A117.1, 2009 EDITION675 IAC 13-2.6 CHAPTER 11HANDICAPPED ACCESSIBILITYCODE (INDIANA AMENDMENTS)1032 SFPROPOSED AREA279 SFTOTAL AREAACCESSIBLE MEANSOF EGRESS TO PUBLICWAYEXITFM - 279 SF / 30 (TABLE 1004.1.2) = 9 OCCUPANTSB - 1023 SF / 100 (TABLE 1004.1.2) = 10 OCCUPANTSTOTAL OCCUPANTS - 19(3) EXITS PROVIDEDEXISTING OFFICE SPACEPROPOSED SALES AREA