Loading...
HomeMy WebLinkAboutPacket for HO 02-28-22 CITY OF CARMEL BOARD OF ZONING APPEALS February 17, 2022 Carmel Clay Public Library Renovation and Expansion 55 4th Avenue SE Carmel, IN 46032 Docket Numbers: PZ-2022-00019 V PZ-2022-00020 V Submitted by: Antone Sgro, AIA RATIO Design Architect for Petitioner 260-479-8694 2 TABLE OF CONTENTS: A. TABLE OF CONTENTS B. EXECUTIVE SUMMARY C. FINDING OF FACT SHEET D. LOCATION MAP E. REDUCTION OF PLANS A-930 – A-934 SIGNAGE SITE PLANS A-935 SIGNAGE EXTERIOR ELEVATIONS L-502 SITE PLANTING PLAN SCHEDULES L-503 SITE PLANTING PLAN F. AFFIDAVITS AND PROOF OF PUBLIC NOTICE ** ADDITIONAL BUILDING CONSTRUCTION DOCUMENTS WERE PREVIOUSLY ISSUED AS PART OF VARIANCES PURSUED AT THE BEGINNING OF CONSTRUCTION. REFER TO: SECTION - A 3 SECTION - B EXECUTIVE SUMMARY The Carmel Clay Public Library (the “Petitioner”) seeks two Development Standards Variances for the renovation and expansion of the existing Main Library located at 55 4th Ave. SE. The renovation and expansion of Main Library involved many upgrades, one of which was creating two new primary public entrances into the building. The exterior building signage was removed during demolition and renovation, therefore new signs are required for wayfinding and building identification. The library is a public building, accessible to all in the Carmel community, and should be easily identifiable from the public right-of way. The architecture and signage will be complimentary and are intended to be legible and clean with a modern aesthetic. No development or new signage is proposed on the Petitioner’s property located west of 4th Ave SE (Richland). Site History, Current Zoning and Surrounding Uses: The Main Library is located on an approximately 6 acre site on the southeast corner of Main Street and 4th Avenue SE (Richland) along with an approximately 2.5 acre site on the southwest corner of Main Street and 4th Avenue SE (Richland), which southwest parcel is used solely for surface parking and stormwater detention. The Main Library received a Special Use to allow construction at this site in 1997. The site was then and still remains zoned R-2. Adjacent zoning is R-2 to the south and east, with R-4 to the west and a mix of B-5, B-3 and R-2 to the north. Adjacent uses include a church to the east, Carmel High School to the north, an elementary school to the south and multifamily to the west. The Petitioner believes the library to be ideally situated to serve the students of the adjacent schools as well as the surrounding residents of Carmel, with ease of access by vehicles, bikes and pedestrians. Approvals Requested: 1. Development Standards Variance, UDO Section 5.39.H.2, (2) Two signs allowed; (3) three requested. 2. Development Standards Variance, UDO Section 5.39.H.6, Ground sign requires delineated cornice; no delineated cornice requested. Refer to Find of Facts Sheet for additional statements of support. 4 SECTION - C FINDING OF FACTS Page 7 of 11 File: Hearing Officer Development Standards Variance Handout 2022 Revised: 01/03/2022 FINDINGS OF FACT SHEET - DEVELOPMENT STANDARDS VARIANCE CARMEL ADVISORY BOARD OF ZONING APPEALS (Petitioner to fill out 1-3 + first two blanks) Docket No.: _______________________________________________ Petitioner: _______________________________________________ 1. The approval of this variance will not be injurious to the public health, safety, morals and general welfare of the community because: _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ 2. The use and value of the area adjacent to the property included in the variance will not be affected in a substantially adverse manner because: _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ 3. The strict application of the terms of the Unified Development to the property will result in practical difficulties in the use of the property because: _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ DECISION IT IS THEREFORE the decision of the Carmel Board of Zoning Appeals that Development Standards Variance Docket No. ___________________________ is granted, subject to any conditions stated in the minutes of this Board, which are incorporated herein by reference and made a part hereof. Adopted this _______________ day of __________________________________, 20 _______. _____________________________________________ _____________________________________________ HEARING OFFICER, Carmel Board of Zoning Appeals _____________________________________________ _____________________________________________ SECRETARY, Carmel Board of Zoning Appeals Conditions of approval of the Board, if any, are listed on the Letter of Grant. 5 SECTION - D LOCATION MAP Hamilton County, Indiana Parcel Boundary (public) May 15, 2020 0 0.04 0.080.02 mi 0 0.065 0.130.0325 km 1:2,400 Hamilton County compiled this map. Although strict accuracy standards have been employed, Hamilton County does not warrant or guarantee the accuracy of the information contained herein and disclaims any and all liability resulting from any error or omission.Author: Hamilton County 6 SECTION - E REDUCTION OF PLANS A-931 A-932 A-933 A-934 SIGNAGE AT EXISTING PARKING LOT TO REMAIN A. SIGNAGE PACKAGE IS IN CONJUNCTION WITH INTERIOR SIGNAGE PACKAGE. B. REFER TO SHEET A-930 FOR KEY PLAN. SIGN ELEVATIONS AND NOTES ARE LOCATED ON SHEET A-935. C. THE FOLLOWING GENERAL NOTES APPLY TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY ONE DISCIPLINE. D. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. E. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT. F. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE, AS WELL AS TAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. G. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE SIGNAGE CONTRACT DOCUMENTS. THESE ITEMS NOT IN CONTRACT ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION, AND COORDINATION ONLY. H. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED. SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE CONTRACT DOCUMENTS. I. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. J. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. K. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. L. SUBSTITUTION OF ANY MATERIALS REQUIRE WRITTEN APPROVAL OF ARCHITECT PRIOR TO BIDDING. M. MOCK-UPS REQUIRED AS INDICATED IN INDIVIDUAL SIGN SPECS. APPROVED MOCK-UPS CAN BE APPLIED TO FINAL INSTALL. N. SIGNAGE MOCK-UP INSTALL WALK-THRU WITH OWNER AND ARCHITECT PRIOR TO OVERALL INSTALLATION REQUIRED. O. SIGNAGE CONTRACTOR IS RESPONSIBLE FOR TYPE SETTING ALL SIGNS. FONT TO BE GOTHAM HTF, UNLESS NOTED OTHERWISE. ARTWORK FOR DIRECTIONAL ARROWS TO BE DEVELOPED BY SIGNAGE CONTRACTOR TO MATCH ARCHITECTURAL DRAWINGS. DIMENSIONS ARE APPROXIMATE AND MAY NEED TO ADJUST PER LOCAL JURISDICTION REQUIREMENTS AND VISIBILITY REQUIREMENTS. P. CONTRACTOR TO FIELD VERIFY SITE CONDITIONS AND COORDINATE PROPOSED SITE CONDITIONS WITH OTHER CONTRACT DOCUMENTS. SITE CONDITIONS VARY PER SIGN, TYPE AND LOCATION. Q. DASHED LINES ON SIGN ELEVATIONS ARE NOT TO PRINT ON FINAL SIGN DESIGN. DASHED LINES ARE FOR ILLUSTRATION PURPOSES TO DEPICT SIGN AREA. R. LETTERING AND SYMBOLS ON METAL SIGNS TO BE DYE- SUBLIMATION PRINTED CONTENT. SHEET TITLE SHEET NUMBER CARMEL CLAY PUBLIC LIBRARY 55 4th Ave. SE Carmel, IN 46032 317-814-3900 Owner RATIO Architects, Inc. 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer Mechanical / Electrical Engineer Civil Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 KBSO Consulting, LLC 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 Civil & Environmental Consultants, Inc. 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 PROJECT NO. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET ISSUE SEAL | DATE Technology Design Design 27 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Garage Consultant Walker Consultants 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 10/18/2021 5:59:19 PMA-930 SIGNAGE SITE PLAN OVERALL 18104.000 CARMEL CLAY PUBLIC LIBRARY RENOVATION 55 4th Avenue SE Carmel, IN 46032 1" = 30'-0"A-930 1 SITE PLAN OVERALL GENERAL EXTERIOR SIGNAGE NOTES 1 ASI 42-SIGNAGE 10/18/21 10/18/21 A-932SIGN EX-W6 EQUALEQUAL SIGN EX-W6 EQUALEQUALA. SIGNAGE PACKAGE IS IN CONJUNCTION WITH INTERIOR SIGNAGE PACKAGE. B. REFER TO SHEET A-930 FOR KEY PLAN. SIGN ELEVATIONS AND NOTES ARE LOCATED ON SHEET A-935. C. THE FOLLOWING GENERAL NOTES APPLY TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY ONE DISCIPLINE. D. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. E. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT. F. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE, AS WELL AS TAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. G. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE SIGNAGE CONTRACT DOCUMENTS. THESE ITEMS NOT IN CONTRACT ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION, AND COORDINATION ONLY. H. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED. SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE CONTRACT DOCUMENTS. I. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. J. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. K. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. L. SUBSTITUTION OF ANY MATERIALS REQUIRE WRITTEN APPROVAL OF ARCHITECT PRIOR TO BIDDING. M. MOCK-UPS REQUIRED AS INDICATED IN INDIVIDUAL SIGN SPECS. APPROVED MOCK-UPS CAN BE APPLIED TO FINAL INSTALL. N. SIGNAGE MOCK-UP INSTALL WALK-THRU WITH OWNER AND ARCHITECT PRIOR TO OVERALL INSTALLATION REQUIRED. O. SIGNAGE CONTRACTOR IS RESPONSIBLE FOR TYPE SETTING ALL SIGNS. FONT TO BE GOTHAM HTF, UNLESS NOTED OTHERWISE. ARTWORK FOR DIRECTIONAL ARROWS TO BE DEVELOPED BY SIGNAGE CONTRACTOR TO MATCH ARCHITECTURAL DRAWINGS. DIMENSIONS ARE APPROXIMATE AND MAY NEED TO ADJUST PER LOCAL JURISDICTION REQUIREMENTS AND VISIBILITY REQUIREMENTS. P. CONTRACTOR TO FIELD VERIFY SITE CONDITIONS AND COORDINATE PROPOSED SITE CONDITIONS WITH OTHER CONTRACT DOCUMENTS. SITE CONDITIONS VARY PER SIGN, TYPE AND LOCATION. Q. DASHED LINES ON SIGN ELEVATIONS ARE NOT TO PRINT ON FINAL SIGN DESIGN. DASHED LINES ARE FOR ILLUSTRATION PURPOSES TO DEPICT SIGN AREA. R. LETTERING AND SYMBOLS ON METAL SIGNS TO BE DYE- SUBLIMATION PRINTED CONTENT. SHEET TITLE SHEET NUMBER CARMEL CLAY PUBLIC LIBRARY 55 4th Ave. SE Carmel, IN 46032 317-814-3900 Owner RATIO Architects, Inc. 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer Mechanical / Electrical Engineer Civil Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 KBSO Consulting, LLC 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 Civil & Environmental Consultants, Inc. 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 PROJECT NO. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET ISSUE SEAL | DATE Technology Design Design 27 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Garage Consultant Walker Consultants 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 10/18/2021 5:59:24 PMA-931 SIGNAGE SITE PLAN 18104.000 CARMEL CLAY PUBLIC LIBRARY RENOVATION 55 4th Avenue SE Carmel, IN 46032 1" = 30'-0"A-931 1 SITE PLAN-WEST GENERAL EXTERIOR SIGNAGE NOTES 1 ASI 42-SIGNAGE 10/18/21 10/18/21 SIGN EX-G1 SIGN EX-W1 NEW 25' FLAGPOLE (NOT IN SIGN SCOPE)A-931A-933 SIGN EX-G2 SIGN EX-W3 MOUNT ON FACE OF CANOPY, CENTERED 5'-0" MINIMUM LANDSCAPE PLANTINGS IN FRONT OF SIGN TO EQUAL AREA OF SIGN (45 S.F.) A. SIGNAGE PACKAGE IS IN CONJUNCTION WITH INTERIOR SIGNAGE PACKAGE. B. REFER TO SHEET A-930 FOR KEY PLAN. SIGN ELEVATIONS AND NOTES ARE LOCATED ON SHEET A-935. C. THE FOLLOWING GENERAL NOTES APPLY TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY ONE DISCIPLINE. D. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. E. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT. F. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE, AS WELL AS TAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. G. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE SIGNAGE CONTRACT DOCUMENTS. THESE ITEMS NOT IN CONTRACT ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION, AND COORDINATION ONLY. H. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED. SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE CONTRACT DOCUMENTS. I. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. J. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. K. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. L. SUBSTITUTION OF ANY MATERIALS REQUIRE WRITTEN APPROVAL OF ARCHITECT PRIOR TO BIDDING. M. MOCK-UPS REQUIRED AS INDICATED IN INDIVIDUAL SIGN SPECS. APPROVED MOCK-UPS CAN BE APPLIED TO FINAL INSTALL. N. SIGNAGE MOCK-UP INSTALL WALK-THRU WITH OWNER AND ARCHITECT PRIOR TO OVERALL INSTALLATION REQUIRED. O. SIGNAGE CONTRACTOR IS RESPONSIBLE FOR TYPE SETTING ALL SIGNS. FONT TO BE GOTHAM HTF, UNLESS NOTED OTHERWISE. ARTWORK FOR DIRECTIONAL ARROWS TO BE DEVELOPED BY SIGNAGE CONTRACTOR TO MATCH ARCHITECTURAL DRAWINGS. DIMENSIONS ARE APPROXIMATE AND MAY NEED TO ADJUST PER LOCAL JURISDICTION REQUIREMENTS AND VISIBILITY REQUIREMENTS. P. CONTRACTOR TO FIELD VERIFY SITE CONDITIONS AND COORDINATE PROPOSED SITE CONDITIONS WITH OTHER CONTRACT DOCUMENTS. SITE CONDITIONS VARY PER SIGN, TYPE AND LOCATION. Q. DASHED LINES ON SIGN ELEVATIONS ARE NOT TO PRINT ON FINAL SIGN DESIGN. DASHED LINES ARE FOR ILLUSTRATION PURPOSES TO DEPICT SIGN AREA. R. LETTERING AND SYMBOLS ON METAL SIGNS TO BE DYE- SUBLIMATION PRINTED CONTENT. SHEET TITLE SHEET NUMBER CARMEL CLAY PUBLIC LIBRARY 55 4th Ave. SE Carmel, IN 46032 317-814-3900 Owner RATIO Architects, Inc. 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer Mechanical / Electrical Engineer Civil Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 KBSO Consulting, LLC 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 Civil & Environmental Consultants, Inc. 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 PROJECT NO. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET ISSUE SEAL | DATE Technology Design Design 27 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Garage Consultant Walker Consultants 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 10/18/2021 5:59:29 PMA-932 SIGNAGE SITE PLAN 18104.000 CARMEL CLAY PUBLIC LIBRARY RENOVATION 55 4th Avenue SE Carmel, IN 46032 1" = 30'-0"A-932 1 SITE PLAN-NORTH GENERAL EXTERIOR SIGNAGE NOTES 1 ASI 42-SIGNAGE 10/18/21 10/18/21 A-932 MATCHLINE -SEE A-934 SIGN EX-W2 SIGN EX-W3 SIGN EX-W4 SIGN EX-W7 SIGN EX-W5 SIGN EX-W5 SIGN EX-G5 SIGN EX-G9 SIGN EX-G8 SIGN EX-G8 SIGN EX-G6 SIGN EX-G7 A B BA A B A B B A SIGN EX-G3 2 SIGN EX-G4 2 A. SIGNAGE PACKAGE IS IN CONJUNCTION WITH INTERIOR SIGNAGE PACKAGE. B. REFER TO SHEET A-930 FOR KEY PLAN. SIGN ELEVATIONS AND NOTES ARE LOCATED ON SHEET A-935. C. THE FOLLOWING GENERAL NOTES APPLY TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY ONE DISCIPLINE. D. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. E. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT. F. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE, AS WELL AS TAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. G. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE SIGNAGE CONTRACT DOCUMENTS. THESE ITEMS NOT IN CONTRACT ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION, AND COORDINATION ONLY. H. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED. SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE CONTRACT DOCUMENTS. I. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. J. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. K. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. L. SUBSTITUTION OF ANY MATERIALS REQUIRE WRITTEN APPROVAL OF ARCHITECT PRIOR TO BIDDING. M. MOCK-UPS REQUIRED AS INDICATED IN INDIVIDUAL SIGN SPECS. APPROVED MOCK-UPS CAN BE APPLIED TO FINAL INSTALL. N. SIGNAGE MOCK-UP INSTALL WALK-THRU WITH OWNER AND ARCHITECT PRIOR TO OVERALL INSTALLATION REQUIRED. O. SIGNAGE CONTRACTOR IS RESPONSIBLE FOR TYPE SETTING ALL SIGNS. FONT TO BE GOTHAM HTF, UNLESS NOTED OTHERWISE. ARTWORK FOR DIRECTIONAL ARROWS TO BE DEVELOPED BY SIGNAGE CONTRACTOR TO MATCH ARCHITECTURAL DRAWINGS. DIMENSIONS ARE APPROXIMATE AND MAY NEED TO ADJUST PER LOCAL JURISDICTION REQUIREMENTS AND VISIBILITY REQUIREMENTS. P. CONTRACTOR TO FIELD VERIFY SITE CONDITIONS AND COORDINATE PROPOSED SITE CONDITIONS WITH OTHER CONTRACT DOCUMENTS. SITE CONDITIONS VARY PER SIGN, TYPE AND LOCATION. Q. DASHED LINES ON SIGN ELEVATIONS ARE NOT TO PRINT ON FINAL SIGN DESIGN. DASHED LINES ARE FOR ILLUSTRATION PURPOSES TO DEPICT SIGN AREA. R. LETTERING AND SYMBOLS ON METAL SIGNS TO BE DYE- SUBLIMATION PRINTED CONTENT. SHEET TITLE SHEET NUMBER CARMEL CLAY PUBLIC LIBRARY 55 4th Ave. SE Carmel, IN 46032 317-814-3900 Owner RATIO Architects, Inc. 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer Mechanical / Electrical Engineer Civil Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 KBSO Consulting, LLC 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 Civil & Environmental Consultants, Inc. 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 PROJECT NO. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET ISSUE SEAL | DATE Technology Design Design 27 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Garage Consultant Walker Consultants 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 2/16/2022 10:32:23 PMA-933 SIGNAGE SITE PLAN 18104.000 CARMEL CLAY PUBLIC LIBRARY RENOVATION 55 4th Avenue SE Carmel, IN 46032 1" = 40'-0"A-933 1 SITE PLAN-CENTRAL GENERAL EXTERIOR SIGNAGE NOTES 1 ASI 42-SIGNAGE 10/18/21 2 ASI 42R2-SIGNAGE 2/17/22 2/17/22 A. SIGNAGE PACKAGE IS IN CONJUNCTION WITH INTERIOR SIGNAGE PACKAGE. B. REFER TO SHEET A-930 FOR KEY PLAN. SIGN ELEVATIONS AND NOTES ARE LOCATED ON SHEET A-935. C. THE FOLLOWING GENERAL NOTES APPLY TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY ONE DISCIPLINE. D. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. E. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT. F. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE, AS WELL AS TAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. G. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE SIGNAGE CONTRACT DOCUMENTS. THESE ITEMS NOT IN CONTRACT ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION, AND COORDINATION ONLY. H. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED. SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE CONTRACT DOCUMENTS. I. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. J. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. K. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. L. SUBSTITUTION OF ANY MATERIALS REQUIRE WRITTEN APPROVAL OF ARCHITECT PRIOR TO BIDDING. M. MOCK-UPS REQUIRED AS INDICATED IN INDIVIDUAL SIGN SPECS. APPROVED MOCK-UPS CAN BE APPLIED TO FINAL INSTALL. N. SIGNAGE MOCK-UP INSTALL WALK-THRU WITH OWNER AND ARCHITECT PRIOR TO OVERALL INSTALLATION REQUIRED. O. SIGNAGE CONTRACTOR IS RESPONSIBLE FOR TYPE SETTING ALL SIGNS. FONT TO BE GOTHAM HTF, UNLESS NOTED OTHERWISE. ARTWORK FOR DIRECTIONAL ARROWS TO BE DEVELOPED BY SIGNAGE CONTRACTOR TO MATCH ARCHITECTURAL DRAWINGS. DIMENSIONS ARE APPROXIMATE AND MAY NEED TO ADJUST PER LOCAL JURISDICTION REQUIREMENTS AND VISIBILITY REQUIREMENTS. P. CONTRACTOR TO FIELD VERIFY SITE CONDITIONS AND COORDINATE PROPOSED SITE CONDITIONS WITH OTHER CONTRACT DOCUMENTS. SITE CONDITIONS VARY PER SIGN, TYPE AND LOCATION. Q. DASHED LINES ON SIGN ELEVATIONS ARE NOT TO PRINT ON FINAL SIGN DESIGN. DASHED LINES ARE FOR ILLUSTRATION PURPOSES TO DEPICT SIGN AREA. R. LETTERING AND SYMBOLS ON METAL SIGNS TO BE DYE- SUBLIMATION PRINTED CONTENT. SHEET TITLE SHEET NUMBER CARMEL CLAY PUBLIC LIBRARY 55 4th Ave. SE Carmel, IN 46032 317-814-3900 Owner RATIO Architects, Inc. 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer Mechanical / Electrical Engineer Civil Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 KBSO Consulting, LLC 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 Civil & Environmental Consultants, Inc. 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 PROJECT NO. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET ISSUE SEAL | DATE Technology Design Design 27 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Garage Consultant Walker Consultants 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 10/18/2021 5:59:34 PMA-934 SIGNAGE SITE PLAN 18104.000 CARMEL CLAY PUBLIC LIBRARY RENOVATION 55 4th Avenue SE Carmel, IN 46032 1" = 30'-0"A-934 1 SITE PLAN-SOUTH GENERAL EXTERIOR SIGNAGE NOTES 1 ASI 42-SIGNAGE 10/18/21 10/18/21 HEIGHT ABOVE GRADE15'-10"3 1'-0"+/- 22'-1"EQ EQ EQEQ3'-4"28'-4" 3 3 LIBRARY PARKING DELIVERIES1'-8"1'-4"3'-0"2'-6" 3"EQ5"2"5"EQ3 S.F. BOX (DASHED LINES) 5" 34'-8"2'-0"BRICK VENEER TO MATCH BUILDING FACADE OVER 8" CMU LIMESTONE COPING OVER THRU-WALL FLASHING RE-PURPOSE EXISTING LIMESTONE SIGN, TRIM LIMESTONE PANELS AS REQUIRED 4"3'-4"F3 A-935 +/- 30'-3 15/16"1'-4"PLANTINGS PER LANDSCAPE PLAN GROUND LIGHTS PER ELECTRICAL PLAN EQ 31'-0"EQ LIBRARY2'-8"CONFIRM WITH OWNER 16'-8" LIMESTONE WALL WITH SKATESTOPPERS AT EACH TOP JOINT; LOCATE LETTERS TO AVOID SKATESTOPPERS SLOPED WALK (BEYOND) PLANTINGS PER LANDSCAPE PLAN BOX LETTERS 2'-8"2" 6" GROUND LIGHTS LIBRARY5'-0"3 BRICK VENEER TO MATCH BUILDING FACADE OVER 8" CMU LIMESTONE COPING OVER THRU-WALL FLASHING 3'-4"4"34'-8" LIBRARY ENTRANCE1'-8"1'-4"3'-0"2'-6" 3"7 1/2"5"7 1/2"3 S.F. BOX (DASHED LINES) 5" SLOW!1'-8"1'-4"3'-0"2'-6" 3"3"1'-2"3"3 S.F. BOX (DASHED LINES) PEDESTRIAN CROSSINGEXIT / PARK1'-8"1'-4"3'-0"2'-6" 3"EQ5"2"5"EQ3 S.F. BOX (DASHED LINES) DELIVERIES 2'-6" 3" 3 S.F. BOX (DASHED LINES) NO EXIT STOP! SIDE 'A'SIDE 'B' 5"1'-8"1'-4"3'-0"1'-2"RIGHT TURN ONLY AT GARAGE ENTRY1'-8"1'-4"3'-0"2'-6" 3"EQ1'-2"EQ3 S.F. BOX (DASHED LINES)4"5"5" DELIVERIES1'-8"1'-4"3'-0"2'-6" 3"EQ5"2"5"EQ3 S.F. BOX (DASHED LINES) PARK / EXIT 2'-6" 3" 3 S.F. BOX (DASHED LINES) SIDE 'A'SIDE 'B' EXIT PARK PARK - EXIT LIBRARY PARKING DELIVERIES RETURNS RETURNSRETURNS SIGN EX-W5 SIGN EX-W2 SIGN EX-W3 SIGN EX-W4 EQEQEQEQ SIGN EX-W7 EQ EQ RETURNS SIGN EX-W8 CENTER SIGNS ON WALL PANEL AND EQUALLY BETWEEN REVEALSHEIGHT TO BRIDGE15'-4"6'-0"CENTER SIGNS ABOVE WINDOW CENTER SIGNS ON WALL PANEL EQ EQ EQ EQ RETURNS8"4'-6" 3 S.F. SIGN DELIVERY8"4'-6" 3 S.F. SIGN PARK-EXIT8"4'-6" 3 S.F. SIGN RETURNS6"2'-0" FONT CENTERED FASTENERS CENTERED NO TRESPASSING6"1'-2" FONT CENTERED PRE-CUT HOLES FOR ATTACHMENT LIBRARY PARKING8"4'-6"EQ5"EQ3 S.F. SIGN 1 1/4" 3 5/8" 1" GROUT SOLID 7 5/8" 1" GROUT SOLID 3 5/8" 1 3/8" 1'-4 7/8"3'-0"8"8"RE-USE LIMESTONE2'-0"8"4"LIMESTONE COPING OVER THRU-WALL FLASHING; PROVIDE DRIP EDGE CUTS (BOTH SIDE) BRICK VENEER TO MATCH BUILDING FACADE GROUT SOLID WITH VERTICAL REBAR AT 24" O.C. SLOPE 042000.A02 042000.H01 4"PROVIDE #4 BARS AT 12" O.C. HORIZ., MIN. 4" CONCRETE COVER RETURNS6"2'-10" 1.33 S.F. SIGN EXIT1'-8"1'-4"3'-0"2'-6" 3"EQ5"2"5"EQ3 S.F. BOX (DASHED LINES) DELIVERIES 2'-6" 3" 3 S.F. BOX (DASHED LINES) SIDE 'A'SIDE 'B' DELIVERIES PARK SHEET TITLE SHEET NUMBER CARMEL CLAY PUBLIC LIBRARY 55 4th Ave. SE Carmel, IN 46032 317-814-3900 Owner RATIO Architects, Inc. 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer Mechanical / Electrical Engineer Civil Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 KBSO Consulting, LLC 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 Civil & Environmental Consultants, Inc. 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 PROJECT NO. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET ISSUE SEAL | DATE Technology Design Design 27 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Garage Consultant Walker Consultants 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 2/16/2022 11:23:58 PMA-935 SIGNAGE EXTERIOR ELEVATIONS 18104.000 CARMEL CLAY PUBLIC LIBRARY RENOVATION 55 4th Avenue SE Carmel, IN 46032 WEST ELEVATION - AREA 'A' - ENLARGED 1/4" = 1'-0" EX-W1 - ELEVATION - AREA 'A' SPECS: 1. SIZE: 1'-0" T x 22'-1" = +/-22 S.F. 2. FONT: GOTHAM HTF BOOK 3. MATERIAL: ANODIZED ALUMINUM -DARK BRONZE (NON-ILLUMINATED) 4. EXTERIOR MOUNTING : ATTACH TO WALL AT MORTAR JOINTS WITH CONCEALED PIN-MOUNT RODS AND EXTERIOR GRADE CLEAR SILICONE, BACK OF LETTERS FLUSH WITH BRICK FACE. 5. PLEASE PROVIDE FULL-SCALE MOCK-UP OF ONE LETTER. 1" = 1'-0" SIGN EX-G6-GARAGE-DELIVERIES EX-G2 - ELEVATION-WEST 1/2" = 1'-0" SIGN EX-G1-LIBRARY 1/4" = 1'-0" EX-G2 - ELEVATION-EAST SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. SINGLE SIDE MESSAGE; BACK OF SIGN IS SOLID COLOR TO MATCH FRONT. SPECS: 1. SIZE: 2'-8" x 16'-6" = 45 S.F. (MAXIMUM); LETTERS = 6" DEEP CHARACTERS 2. FONT: GOTHAM HTF BOLD 3. MATERIAL: METAL CHANNEL BOX LETTERS WITH PHOTO POLYMER FINISH FACE, METAL PAINTED TO MATCH POLYMER FACE. 4. COLOR: WHITE, OPAQUE 5. EXTERIOR MOUNTING : MOUNT INDIVIDUAL LETTERS DIRECTLY TO LIMESTONE WALL WITH EXPANSION ANCHORS OR BY MEANS RECOMMENDED BY SIGN CONTRACTOR. COORDINATE LOCATION OF LETTERS WITH SKATE-STOPPERS (NOT IN SIGN SCOPE). LIMESTONE WALL TO BE PROVIDED BY OTHERS. 6. PLEASE PROVIDE FULL SCALE MOCK-UP REQUIRED OF CHARACTER 'B' WITH MOUNTING HARDWARE. 1" = 1'-0" SIGN EX-G3-ENTRY SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. DUAL-SIDED, SAME MESSAGE ON BOTH SIDES WITH ARROW POINTING IN SAME DIRECTION. 1" = 1'-0" SIGN EX-G4-SLOW SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. SINGLE-SIDED MESSAGE, CENTERED; BACK OF SIGN IS SOLID COLOR TO MATCH FRONT. 1" = 1'-0" SIGN EX-G5-STOP-DELIVERIES-EXIT 1" = 1'-0" SIGN EX-G7-RIGHT TURN ONLY SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. SINGLE SIDE MESSAGE; BACK OF SIGN IS SOLID COLOR TO MATCH FRONT. 1" = 1'-0" SIGN EX-G9-EXIT-NO LEFT TURN 1/8" = 1'-0" WEST ELEVATION - AREA 'B' 1" = 1'-0" SIGN EX-W2-RETURNS 1" = 1'-0" SIGN EX-W3-DELIVERIES 1" = 1'-0" SIGN EX-W4-PARK-EXIT 1" = 1'-0" SIGN EX-W5-RETURNS-SMALL 1" = 1'-0" SIGN EX-W6-NO TRESPASSING SPECS: 1. FONT: GOTHAM HTF BOOK, SIZE AS INDICATED 2. MATERIAL: DIMENSIONAL METAL LETTERS, 1/2" THICK, PAINTED 3. COLOR: LETTERING AND SYMBOLS TO BE BRIGHT WHITE (ALL SIDES) 4. EXTERIOR MOUNTING : INDIVIDUAL LETTERS MOUNTED ON EXTERIOR BUILDING WALL PANEL (METAL) WITH EXTERIOR GRADE CLEAR SILICONE / PIN MOUNTS. 5. DASHED LINE INDICATES OVERALL SIGN AREA ONLY. 6. PLEASE PROVIDE FULL-SCALE MOCK-UP OF SIGN TYPE EX-W2. SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL PLATE RATED FOR EXTERIOR APPLICATION. 3. COLOR: DARK BRONZE PLATE, LETTER / GRAPHIC TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : MOUNTED ON BRICK WITH FLAT HEAD SET SCREWS INTO MORTAR JOINT WITH EXTERIOR GRADE CLEAR SILICONE, FASTENER COLOR TO MATCH PANEL FINISH. 5. SINGLE-SIDED SIGN. 1" = 1'-0" SIGN EX-W7-LIBRARY PARKING 3/4" = 1'-0" WALL SECTION 1" = 1'-0" SIGN EX-W8-RETURNS SMALL 1" = 1'-0" SIGN EX-G8-PARK-DELIVERIES-EXIT SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. DUAL-SIDED, DIFFERENT MESSAGE ON EACH SIDE (A & B). 6. FULL SCALE SIGN MOCK-UP REQUIRED. SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. DUAL-SIDED, DIFFERENT MESSAGE ON EACH SIDE (A & B). SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL CABINET ON POSTS W/ PAINTED GRAPHIC / TEXT 3. COLOR: PANEL AND POSTS TO BE DARK BRONZE, LETTERING TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : POST MOUNTED, ANCHORING PROPOSED BY CONTRACTOR. 5. DUAL-SIDED, DIFFERENT MESSAGE ON EACH SIDE (A & B). 1 ASI 42-SIGNAGE 10/18/21 2 ASI 42R-SIGNAGE 11/4/21 3 ASI 42R2-SIGNAGE 2/17/22 2/17/22 SPECS: 1. FONT: GOTHAM HTF BOOK 2. MATERIAL: METAL PLATE RATED FOR EXTERIOR APPLICATION. 3. COLOR: DARK BRONZE PLATE, LETTER / GRAPHIC TO BE BRIGHT WHITE. 4. EXTERIOR MOUNTING : MOUNTED ON METAL CHAIN-LINK FENCE, FASTENER COLOR TO MATCH PANEL FINISH. PROVIDE PRE-CUT HOLES FOR ATTACHMENT. 5. SINGLE-SIDED, BACK OF SIGN TO BE SOLID COLOR TO MATCH FRONT. 6. PLEASE PROVIDE FULL-SCALE MOCK-UP OF SIGN TYPE EX-W6. SPECS: 1. SIZE: 1'-4" x 30'-4" = 40 S.F. 2. THIS SIGN IS TO BE BUILT OUT-SIDE OF SIGN CONTRACTOR SCOPE. THE DRAWINGS FOR EX-G2 ARE INCLUDED ON THIS SHEET FOR LOCAL PERMITTING ONLY. 3. MATERIAL: AS NOTED ON ELEVATIONS AND SECTIONS. ASI-4512/30/21 600CALC CORNER SET X IN WALK ON LINE ORIGIN (STARTING POINT)SURVEY ORIGIN(TO BE MODIFIED)BOUNDARY LINER.O.W. LINE R.O.W. LINELIM I T S O F W O R K LIMITS OF WORK1 IJD 5 IRS EXISTING TREE, 18" LT2 4 CANNOT BE ACHIEVED WITH EXISTING CONDITIONSSIDE BUFFER YARD "D" SPECIAL USE INSTITUTIONAL, WITH ADJACENT SINGLE FAMILY. MIN. 30' BUFFER YARD REQUIRED. SHADE OR EVERGREEN TREES: 8. ORNAMENTAL TREES: 2. SHRUBS: 20. NO WORK IN R.O.W. / OUTSIDE OF PATH.SIDE BUFFERYARD "D" MINIMUM 30'PROPERTY LINE LENGTH = 746'IWR IWR IWR 91.22'IWR ISG ISGISG FORB 31 FORB 30 3 IJD 3 ISG 3 JV 7 VDE SEDG 905 FORB 12 FORB 30 FORB 29 FORB 12 FORB 14 SEDG 1,401 FORB 31 FORB 31 FORB 31 6 HPL FORB 13 3 IJD 4 IWR TC 5 JV EXISTING TREE, 18" EXISTING TREE, 12" EXISTING TREE, 18" EXISTING TREE, 18" EXISTING TREE, 18" EXISTING TREE, 12" EXISTING TREE, 36" EXISTING TREE, 24" EXISTING TREE, 12" EXISTING TREE, 24" EXISTING TREE, 8" 1 TA 1 CC 1 NW EXISTING TREE, 18" EXISTING TREE, 15"601 sI BUFF 1,180 sI BUFF 87 GERA 63 CM GERA 120 CM 101 6 HAB HAB 7 OV 1 GERA 65 CM 72 HAB 7 OV 1 CM 420 GERA 603 HAB 21 646 PVS 679 GERA20 ALSC 20 ALSC IWR BG 5 MD 30 SM 2 NR 24 16 ALSC 2 SM 5 BG SAL 116 28 NK TS 8,287 sI SAL 509 SAL 340 SAL 339 SAL 58 SAL 57 1 IJD 5 IRS 8 AHU SAL 345 REPAIR TURF FOR IRRIGATION ROUTING AS NECESSARY 4,796 sI TS3 PVS 427 TS 615 sI TS 1,040 sI TS 1,256 sI 1 UM1 1 UM2 1 UM3 1 LT3 1 LT1 1 LT2 SOD REPAIR AS NECESSARY ALONG NEW WALKWAY SEDG 700 234 sI BUFF LT2 2 QR2 2 FORB 31 CS 261 SC2 73 SC2 74 8 AHU 8 AHU ALSC 60 AHU 8 IRS 6 IJD 1 AHU 8 SAL 340 SAL 35 38 SAL 8 AHU 8 AHU 8 AHU 8 AHU 1 IJD 1 IJD 1 IJD 1 IJD 5 IRS 6 IRS 5 IRS 6 IRSAHU 8 8 AHU 8 AHU 8 AHU ALSC 60 ALSC 60 ALSC 60 ALSC 60 20 ALSCALSC 20 ALSC 20 ALSC 20 18104.00 Owner Mechanical / Electrical Engineer Civil Engineer Architect 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 RATIO 55 4TH Ave. SE Carmel, IN 46032 317-814-3900 CARMEL CLAY PUBLIC LIBRARY Carmel Clay Public Library Renovation 55 4th Ave SE Carmel, IN 46032 Structural Engineer 10 Shoshone Drive Carmel, IN 46032 317-818-1912 CE Solutions 1344 South Rangeline, Suite 202 Carmel, IN 46032 317-344-8044 KBSO Consulting, LLC 530 E. Ohio Street, Suite G Indianapolis, IN 46204 317-655-7777 Civil & Environmental Consultants, INC Technology Design Garage Consultant 1650 East 49th Street Indianapolis, IN 46205 317-536-8000 Design 27 6602 East 75th Street, Suite 210 Indianapolis, IN 46250 317-842-6890 Walker Consultants FROM OUTSIDE INDIANAINSIDE INDIANA 1-800-428-52001-800-382-5544 (TWO WORKING DAYS PLEASE) HOLEY MOLEY SAYS, "CALL BEFORE YOU DIG" 1 L-504 PLANTING PLAN 1"=20'-0"0 10'20'40' GENERAL NOTES: 1.2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN. 2.ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING. 3.ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH. 4.TOPSOIL DEPTHS: 5.1.TURF - 6" 5.2.GROUND COVER/SHRUBS - 14" 5.3.TREE - DEPTH OF ROOTBALL AND 2X WIDTH 6.ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST PLANTING NOTES 1.PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR TO COMMENCEMENT. 2.MATCH GRAPHIC REPRESENTATION SHOWN UNLESS NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR PLACEMENT OF HATCHED AREAS. 3.EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR PROPOSED UTILITIES. 4.COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION. 5.INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT OTHERWISE IDENTIFIED FOR PLANT MATERIAL. 6.PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS. 7.REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING, AND STAKING REQUIREMENTS. 8.FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST OF CONTRACTOR. 9.CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS' PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH EQUIVALENT SIZE PLANTS. COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET TITLE SHEET NUMBER SHEET ISSUE PROJECT NO. SEAL | DATE L-504 SITE PLANTING PLAN 1 100% CONSTRUCTION DOCUMENTS 7/14/2020 2 STATE SUBMISSION SET 7/17/2020 3 TAC COMMENT RESPONSE 7/31/2020 4 CONFORMED SET 09/18/20 MATCHLINE - SEE L-505MATCHLINE - SEE L-5031 L-507 3 3 3 5 5 ASI-45 12/30/21 7 SECTION - F AFFIDAVITS AND PROOF OF PUBLIC NOTICE