Loading...
HomeMy WebLinkAboutC803 SITE DETAILS2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343Phone (888) 344-9044 Fax (423) 826-2112www.aquashieldinc.comStructure #:Drawn By:Scale:Date:8/30/2019RvwedRvw. DateU.S. Patent No. 6524473 and other Patent PendingAqua-Swirl XCeleratorAs ShownOFloresAqua-Swirl Stormwater Treatment SystemStandard DetailXC-2 CCW STDXC-2 STDAqua-Swirl Polymer Coated Steel (PCS)Stormwater Treatment System12 in[305 mm]Manhole Frame & Cover DetailFor Non-Traffic Areas OnlyNTS4 in[1219 mm] Min.Gravel BackfillConcreteWrap Compressible ExpansionJoint Material to a minimum1/2-inch [13 mm] thickness aroundtop of riser to allow transfer ofinadvertent loading frommanhole cover to concrete slab.RiserSoilCoverFrame1/2 in[13 mm]1/2 in[13 mm]Place small amount ofconcrete [3,000 psi [20MPa] (min)] to supportand level manhole frame.DO NOT allow manholeframe to rest upon riser.Backfill (90%Proctor Density)8 in[203 mm]4 1/2 in[114 mm]Unless other traffic barriers are present,bollards shall be placed around access riser(s)in non-traffic areas to prevent inadvertentloading by maintenance vehicles.Manhole Frame & Cover DetailFor Traffic Loading AreasNTSCoverFrame48 in[1219 mm] Min.Backfill (90%Proctor Density)3,000 psi [20 MPa](min) Concrete#4 [13 mm] Rebar@ 6 in [152 mm]Each Way30 in [762 mm]Riser1/2 in[13 mm]4 1/2 in[114 mm]14 in[356 mm]1/2 in [13 mm] ThickExpansion JointMaterialIf traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m]diameter, 14-inch [356 mm] thick reinforced concrete pad must beplaced over the Stormwater Treatment System Riser to support andlevel the manhole frame, as shown. The top of riser pipe must bewrapped with compressible expansion joint material to a minimum1/2-inch [13 mm] thickness to allow transfer of wheel loads frommanhole cover to concrete slab. Manhole cover shall bear on concreteslab and not on riser pipe. The concrete slab shall have a minimumstrength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm]reinforcing steel as shown. Minimum cover over reinforcing steel shallbe 1-inch [25 mm]. Top of manhole cover and concrete slab shall belevel with finish grade.Please see accompanied Aqua-Swirl specification notes. See SitePlan for actual System orientation. Approximate dry (pick) weight:1000 lbs [500 kg].Backfill shall extend at least 18inches [457 mm] outward fromSwirl Concentrator and for thefull height of the SwirlConcentrator (including riser)extending laterally toundisturbed soils. (See MHDetail Below)BackfillBeddingUndisturbed soil18 in[457 mm]6 in[152 mm]11As an alternative, 42 in [1067 mm] diameter, HS-20/25rated precast concrete rings may be substituted. 14 in[356 mm] thickness must be maintained.XC-2 inlet/outlet pipe size ranges up to 15 in [381 mm].XC-2 chamber height may vary up to 64 in [1626 mm],depending on inlet/outlet pipe size.Orientation may vary from a minimum of 90° to amaximum of 180°. Clockwise or counterclockwiseorientation as needed.2332Plan ViewSCALE 1:40 42 in[1067 mm] 42 in[1067 mm] n15 in[381 mm]2Octagonal Base Plate Ø30 in[Ø765 mm]Elevation ViewSCALE 1:40 64 in[1626 mm][1524 mm][1397 mm] 5 MH Frame[127 mm] n30 in[762 mm]Band Couplerby Manufacturer.(as needed)RiserManhole Frame andCover by Manufacturer.(See Details)Rim elevations tomatch finish grade.Pipe couplingby Contractor.12 in [305 mm]long Stub-outby Manufacturer.44el. VariesInlet/Outlet Invertel. Variesel. VariesGrade (Rim) el. VariesPipe couplingby Contractor.12 in [305 mm]long Stub-outby Manufacturer.Optional inletorientations available(See note 4) n30 in[762 mm]Projected ViewSCALE 1:70 n15 in[381 mm]180° 40 in[1016 mm]PLAN VIEWELEVATION VIEWDETAIL 407 - INLET TYPE ADETAIL 406 - AQUA-SWIRL XC-2 DETAIL8AB3456712CDEFGH83456712ABCDEFGHDESCRIPTIONDATENO REVISION RECORD DATE: DWG SCALE: DRAWN BY: CHECKED BY: APPROVED BY: PROJECT NO:SHEETOFDRAWING NO.:315-285 DEC. 28, 2021 DRAFT21 STUDIO M ARCHITECTURE STUDIO M OFFICE 275 VETERANS WAY CARMEL, INDIANA 46032 530 E. Ohio Street · Suite G - Indianapolis, IN 46204 317-655-7777 · 877-746-0749 www.cecinc.com SITE DETAILS C803SGJ ACHNTS16DETAIL 406 - OUTLET CONTROLSTRUCTURE DETAIL12/28/2021