HomeMy WebLinkAboutA-105-LOW-AND-HIGH-ROOF-PLANS-Rev.8A. THESE GENERAL NOTES APPLY TO ROOF DRAWINGS.
B. VERIFY SIZE, LOCATION AND NUMBER OF ROOF
PENETRATIONS INCLUDING VENTS, PIPES, CURBS, ROOF
DRAINS, CONDUITS, ETC. PROVIDE NEW FLASHING AND
SEAL PENETRATIONS WHETHER OR NOT INDICATED ON THE
DRAWINGS.
C. COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY,
WELDING, MASONRY RESTORATION, ETC., PRIOR TO
STARTING ROOFING WORK.
D. VERIFY AND MAINTAIN ROOF SLOPES AND DRAINAGE
PATTERNS. TEST FOR AND CORRECT ANY PONDING
CONDITIONS.
E. REPAIR AND REPLACE ROOFING SYSTEM OR STRUCTURE
DAMAGED BY IMPROPER STORAGE, CONSTRUCTION
ACTIVITIES, OR LACK OF ADEQUATE TEMPORARY
PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO
FINISHES, EQUIPMENT, FURNISHINGS, ETC., RESULTING
FROM LEAKS.
F. NEW BLOCKING SHALL BE PRESERVATIVE-TREATED WOOD.
G. PAINT EXTERIOR LADDERS, BRACKETS, ETC., UNLESS
NOTED OTHERWISE.
H. CAP FASTENERS THAT PENETRATE ROOF DECK IN AREAS
NOT CONCEALED BY CEILINGS WITH WIRE NUTS OR OTHER
MEANS ACCEPTABLE TO ARCHITECT UNLESS OTHERWISE
INDICATED. AREAS SUCH AS JANITOR CLOSETS, STORAGE
ROOMS, MECHANICAL AND ELECTRICAL EQUIPMENT
ROOMS, ETC., ARE EXEMPT FROM THIS REQUIREMENT
UNLESS OTHERWISE INDICATED.
I. REFER TO WALL SECTIONS NOTED ON ROOF PLANS FOR
INFORMATION.
J. REFER TO MECHANICAL DRAWINGS TO COORDINATE ROOF
CONDUCTOR LOCATIONS.
2
2
5
5
6
6
7
7
A A
E E
D D
B B
C C
F F
G G
4
4
H H
D1
A-302
D1
A-302
A1
A-301
A1
A-301
A-202A1
A-201
E1
A-202
C1
A-201 A1
1/4" / 12"
1/4" / 12"
1/4" / 12"
1/4" / 12"
1
1
8
8
J J
E1
A-301
C1
A-301
C1
A-301
A1
A-302
A1
A-302
A-201 C1
3
1/4" / 12" 1/4" / 12"5/8" / 12" 5/8" / 12"1/4" / 12"1/4" / 12"1/4" / 12"5/8" / 12"1/4" / 12" 1/4" / 12"1/4" / 12"3/8" / 12"5/8" / 12" 1/4" / 12"1/4" / 12"HIGH ROOF
A4
A-353
17'-3"CLR OPEN4'-6"CLR OPENING
2'-6"
077200.C01
077100.A01
075323.A00075323.A00
075323.A00075323.A00
077100.A01
077100.A01
076200.C05
CW BELOWTYPICALPLEATED CURTAIN WALL BELOW077100.A01
CURTAIN WALL BELOW
RTU-REF MECH.
RTU-REF MECH.
RTU- REF
MECH.
RTU- REF
MECH.
076200.C05
076200.C05
076200.C05
1/4" / 12"
1/4" / 12"1/4" / 12"1/4" / 12"
1/4" / 12"2" / 12"W-3
W-4
A-501D1
RTU- REF
MECH.
RTU- REF
MECH. PLEATED CURTAIN WALL BELOWPLEATED CURTAIN WALL BELOW102400
8" 10'-0"
8"
2'-0"2" / 12"12'-0"12'-0"1'-0"2'-0" TYP.8"1'-0"TYP
102400
EXHAUST EQUIP.
REF. MECHANICAL
1" / 12"1/4" / 12"1 1/8" / 12"1/4" / 12"077100.A01
TYP
22-A1
1/2" / 12"1/2" / 12"1/2
" /
12"1 1/8" / 12"
1
1/8"
/
1
2
"
1 1/8" / 1 2 "1
1/8" / 1
2"1/2" / 12"PLEATED CURTAIN WALL BELOW118129.A00
W-9
A7
A-3531/4" / 12"1/4" / 12" 1/4" / 12"1/4" / 12"3/8" / 12" 1/2" / 12"1/4" / 12" 1 1/8" / 12"1/4" / 12"1/4" / 12" 1/4" / 12"3/8" / 12"
1/2" / 12" 1/4" / 12"1/4" / 12"1/4" / 12"3/8" / 12" 1/2" / 12"3/8" / 12"1 1/8" / 12"1/4" / 12"1/2" / 12" 3/8" / 12"1/4" / 12"1/4" / 12"3/8" / 12"11'-0"118129.B01118129.B01 11'-0"23'-1 1/2"18'-0 1/4" 14'-0"
9'-3 1/2"23'-1 1/2"118129.B01
14'-9"
TYP
075323.B01
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
F.A. Wilhelm Construction
3914 Prospect Street
Indianapolis, Indiana 46203
317-359-5411
Construction Manager
12/17/2021 2:06:43 PMA-105
LOW AND HIGH
ROOF PLANS
21040.000
Republic Airways
Training Center
12195 N. Meridian St.
Carmel, Indiana
46032
KEYNOTES (SPEC BASED)
075323.A00 EPDM MEMBRANE ROOFING
075323.B01 EPDM MEMBRANE ROOFING, WALKWAY
SURFACE
076200.C05 SCUPPER
077100.A01 COPING, METAL, MANUFACTURED
077200.C01 ROOF HATCH
102400 ARCHITECTURAL SCREEN
118129.A00 FACILITY FALL PROTECTION
118129.B01 ROOF ANCHOR
GENERAL ROOFING NOTES
3/32" = 1'-0"A-105
A1 ROOF FLOOR PLAN
KEYNOTES (SPEC BASED)
075323.A00 EPDM MEMBRANE ROOFING
075323.B01 EPDM MEMBRANE ROOFING, WALKWAY
SURFACE
076200.C05 SCUPPER
077100.A01 COPING, METAL, MANUFACTURED
077200.C01 ROOF HATCH
102400 ARCHITECTURAL SCREEN
118129.A00 FACILITY FALL PROTECTION
118129.B01 ROOF ANCHOR
KEYNOTES (ACTION/GENERAL)
22-A1 ROOF DRAIN
1 PERMIT SET 11/19/21
11/19/21
02/23/22