HomeMy WebLinkAboutA-105-LOW-AND-HIGH-ROOF-PLANS-Rev.8A. THESE GENERAL NOTES APPLY TO ROOF DRAWINGS. B. VERIFY SIZE, LOCATION AND NUMBER OF ROOF PENETRATIONS INCLUDING VENTS, PIPES, CURBS, ROOF DRAINS, CONDUITS, ETC. PROVIDE NEW FLASHING AND SEAL PENETRATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS. C. COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY, WELDING, MASONRY RESTORATION, ETC., PRIOR TO STARTING ROOFING WORK. D. VERIFY AND MAINTAIN ROOF SLOPES AND DRAINAGE PATTERNS. TEST FOR AND CORRECT ANY PONDING CONDITIONS. E. REPAIR AND REPLACE ROOFING SYSTEM OR STRUCTURE DAMAGED BY IMPROPER STORAGE, CONSTRUCTION ACTIVITIES, OR LACK OF ADEQUATE TEMPORARY PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO FINISHES, EQUIPMENT, FURNISHINGS, ETC., RESULTING FROM LEAKS. F. NEW BLOCKING SHALL BE PRESERVATIVE-TREATED WOOD. G. PAINT EXTERIOR LADDERS, BRACKETS, ETC., UNLESS NOTED OTHERWISE. H. CAP FASTENERS THAT PENETRATE ROOF DECK IN AREAS NOT CONCEALED BY CEILINGS WITH WIRE NUTS OR OTHER MEANS ACCEPTABLE TO ARCHITECT UNLESS OTHERWISE INDICATED. AREAS SUCH AS JANITOR CLOSETS, STORAGE ROOMS, MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, ETC., ARE EXEMPT FROM THIS REQUIREMENT UNLESS OTHERWISE INDICATED. I. REFER TO WALL SECTIONS NOTED ON ROOF PLANS FOR INFORMATION. J. REFER TO MECHANICAL DRAWINGS TO COORDINATE ROOF CONDUCTOR LOCATIONS. 2 2 5 5 6 6 7 7 A A E E D D B B C C F F G G 4 4 H H D1 A-302 D1 A-302 A1 A-301 A1 A-301 A-202A1 A-201 E1 A-202 C1 A-201 A1 1/4" / 12" 1/4" / 12" 1/4" / 12" 1/4" / 12" 1 1 8 8 J J E1 A-301 C1 A-301 C1 A-301 A1 A-302 A1 A-302 A-201 C1 3 1/4" / 12" 1/4" / 12"5/8" / 12" 5/8" / 12"1/4" / 12"1/4" / 12"1/4" / 12"5/8" / 12"1/4" / 12" 1/4" / 12"1/4" / 12"3/8" / 12"5/8" / 12" 1/4" / 12"1/4" / 12"HIGH ROOF A4 A-353 17'-3"CLR OPEN4'-6"CLR OPENING 2'-6" 077200.C01 077100.A01 075323.A00075323.A00 075323.A00075323.A00 077100.A01 077100.A01 076200.C05 CW BELOWTYPICALPLEATED CURTAIN WALL BELOW077100.A01 CURTAIN WALL BELOW RTU-REF MECH. RTU-REF MECH. RTU- REF MECH. RTU- REF MECH. 076200.C05 076200.C05 076200.C05 1/4" / 12" 1/4" / 12"1/4" / 12"1/4" / 12" 1/4" / 12"2" / 12"W-3 W-4 A-501D1 RTU- REF MECH. RTU- REF MECH. PLEATED CURTAIN WALL BELOWPLEATED CURTAIN WALL BELOW102400 8" 10'-0" 8" 2'-0"2" / 12"12'-0"12'-0"1'-0"2'-0" TYP.8"1'-0"TYP 102400 EXHAUST EQUIP. REF. MECHANICAL 1" / 12"1/4" / 12"1 1/8" / 12"1/4" / 12"077100.A01 TYP 22-A1 1/2" / 12"1/2" / 12"1/2 " / 12"1 1/8" / 12" 1 1/8" / 1 2 " 1 1/8" / 1 2 "1 1/8" / 1 2"1/2" / 12"PLEATED CURTAIN WALL BELOW118129.A00 W-9 A7 A-3531/4" / 12"1/4" / 12" 1/4" / 12"1/4" / 12"3/8" / 12" 1/2" / 12"1/4" / 12" 1 1/8" / 12"1/4" / 12"1/4" / 12" 1/4" / 12"3/8" / 12" 1/2" / 12" 1/4" / 12"1/4" / 12"1/4" / 12"3/8" / 12" 1/2" / 12"3/8" / 12"1 1/8" / 12"1/4" / 12"1/2" / 12" 3/8" / 12"1/4" / 12"1/4" / 12"3/8" / 12"11'-0"118129.B01118129.B01 11'-0"23'-1 1/2"18'-0 1/4" 14'-0" 9'-3 1/2"23'-1 1/2"118129.B01 14'-9" TYP 075323.B01 SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 F.A. Wilhelm Construction 3914 Prospect Street Indianapolis, Indiana 46203 317-359-5411 Construction Manager 12/17/2021 2:06:43 PMA-105 LOW AND HIGH ROOF PLANS 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 KEYNOTES (SPEC BASED) 075323.A00 EPDM MEMBRANE ROOFING 075323.B01 EPDM MEMBRANE ROOFING, WALKWAY SURFACE 076200.C05 SCUPPER 077100.A01 COPING, METAL, MANUFACTURED 077200.C01 ROOF HATCH 102400 ARCHITECTURAL SCREEN 118129.A00 FACILITY FALL PROTECTION 118129.B01 ROOF ANCHOR GENERAL ROOFING NOTES 3/32" = 1'-0"A-105 A1 ROOF FLOOR PLAN KEYNOTES (SPEC BASED) 075323.A00 EPDM MEMBRANE ROOFING 075323.B01 EPDM MEMBRANE ROOFING, WALKWAY SURFACE 076200.C05 SCUPPER 077100.A01 COPING, METAL, MANUFACTURED 077200.C01 ROOF HATCH 102400 ARCHITECTURAL SCREEN 118129.A00 FACILITY FALL PROTECTION 118129.B01 ROOF ANCHOR KEYNOTES (ACTION/GENERAL) 22-A1 ROOF DRAIN 1 PERMIT SET 11/19/21 11/19/21 02/23/22