HomeMy WebLinkAboutA-131B-FIRST-FLOOR-REFLECTED-CEILING-PLAN---AREA-B-Rev.72
2
5
5
6
6
7
7
E E
D D
F F
G G
4
4
H H
ACT-01
12'-0" A.F.F.
GWB-X1
11'-0" A.F.F.
1
1
8
8
ACT-01
12'-0" A.F.F.
2'-3"3'-0"2'-0"1'-6" 1'-6"EQ EQ
1'-6"1'-6"1'-6"1'-6"EQEQ1'-0 1/16"J J
ACT-03
13'-0" A.F.F. ACT-01
12'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-03
12'-0" A.F.F.
3
3
CABIN
TRAINER
SUPPORT
SPACES
102
CABIN
TRAINER
103
COMMUNITY
CENTER LAB
107A
WAITING
107
LOCKED
CABIN
TRAINER STG
107B
100 PERSON
AUDITORIUM
106
RAMP
105
UNDER AND
OVER UPPER
CABINET LIGHTSOPEN TO 3RD
FLOOR
PT-11 PT-11
PT-10
PT-10
PT-10
PT-10
GWB-X1
8'-2" A.F.F.
9'-6"
ACT-03
9'-0" A.F.F.
ACT-03
13'-0" A.F.F.
GWB-X1
8'-2" A.F.F.
WOMEN
121
MEN
120
JAN
123
4'-0"
ENTRY STAIR
101
ENTRY STAIR
101
GENDER
NEUTRAL
122
ADA
119
1'-0"2'-4 7/8"
GWB-X1
8'-2" A.F.F.1'-0"3'-6"GWB-X1
8'-0" A.F.F.
GWB-X1
8'-0" A.F.F.2'-9"7'-0"
GWB-X1
12'-0" A.F.F.
GWB-X1
12'-0" A.F.F.
6"
ACT-02
15'-0" A.F.F.
ACT-02
15'-0" A.F.F.
GWB-X1
13'-0" A.F.F.
ACT-01
12'-0" A.F.F.
GWB-X1
13'-0" A.F.F.
GWB-X1
14'-6" A.F.F.
PT-11
GWB-X1
10'-1" A.F.F.5"TYP.
1'-11"EQEQ.ACT-01
11'-0" A.F.F.
GWB-X1
10'-10" A.F.F.
GWB-X1
10'-10" A.F.F.
OPERABLE WALL
PARTITION CEILING
TRACK - VERIFY WITH
MFR.
1'-0"8'-6"8'-6"7'-3"6 5/16"1'-11"ALIGN 11 5/8"EQ.EQ. 1'-0"1'-0"1'-0"6'-0"6'-0"1'-11"EQ.EQ.ALIGNALIGN1'-11"EQ. EQ.
7'-0"
7'-0"
EQ EQ
PT-10PT-11MAINTENANCE
LARGE
EQUIPMENT
TRAINING
111
MAINTENANCE
32 STUDENT
112
MAINTENANCE
30 STUDENT
113 DELIVERY
116
TRASH
117
WATER
SERVICE
117A
LOUNGE
114
60 PERSON
CLASSROOM
118
D5
A-521
D5
A-521 D5
A-521
ALIGNG3
A-521
TYP.
G3
A-521ALIGN
D1
A-521
D1
A-521
E6
A-521
F3
A-521
ALIGN
B1
A-521
B1
A-521
B1
A-521 PT-10G3
A-521
A5
A-521
TYP
B1
A-521
4 1/4"
SIM
TYP
B1
A-521
WT-03 WT-03
WT-02 4'-0"2'-0"
6" ALIGNA1
A-521
TYP.
A1
A-521 TYP.
A1
A-521
TYP.
A3
A-521
G3
A-521
G3
A-521
G3
A-521
9'-0" TYP
B3
A-521
B1
A-521ALIGN2'-7 1/16" 5'-0"
5'-0"4'-0"ACT-03
13'-0" A.F.F.
2'-9"6"2'-6"6"4'-0"EQ EQ EQEQEQ EQEQ
EQA3
A-521
WT-01ALIGN
WT-01
PT-10
GWB-X1
8'-6" A.F.F.
11"
WT-01
PT-10
WT-01
PROVIDE ALTERNATE BID
FOR PENDANTS ALONG
WEST AND NORTH WALL IN
LIEU OF 2'X4' SUSPENDED
FIXTURES
PROVIDE ALTERNATE BID
FOR PENDANTS IN THIS
ROOM IN LIEU OF
SUSPENDED CYLINDER
FIXTURES PROVIDE ALTERNATE BID
FOR FIVE PENDANTS IN
THIS AREA SHOWN IN LIEU
OF ADDITIONAL
DOWNLIGHTS
DOWNLIGHTS SHOWN IN CORRIDOR
TO BE EQUALLY SPACED BETWEEN
NORTH AND SOUTH.1'-2 1/8"ALIGN2'-2 7/8"
6 3/4"
5"
4 1/4"
1'-0" 1'-0"1'-0"ALIGN GLASS
WITH EDGE OF
BULKHEAD
REFERENCE EXTERIOR WALL
SECTION FOR CEILING
CONDITION
ACT-01
11'-2" A.F.F.
GWB-X1
10'-2" A.F.F.
1'-0 "
3
G3
A-521
F3
A-521 1'-2"3'-0 "
12'-9"
3'-0"
12'-9"1'-2"3'-0"1'-2"12'-9"
2'-4 5/8"
3
GWB-X1
10'-2" A.F.F.
ACT-01
12'-0" A.F.F.
PT-10
PT-02
REFERENCE
ARCH PLAN FOR
BULKHEAD
SECTION
3
6"
PT-10
A3
A-521
SIM
A5
A-521
TYP
PT-11
PT-11
PT-11
PT-10
7 1/4"7 1/4"ALIGNPAINT ALL EXPOSED
STRUCTURAL INCLUDING
PIPING, HVAC AND
EXPOSED DUCTWORK
PAINT ALL EXPOSED
STRUCTURAL INCLUDING
PIPING, HVAC AND
EXPOSED DUCTWORK
PAINT ALL EXPOSED
STRUCTURAL INCLUDING
PIPING, HVAC AND
EXPOSED DUCTWORK
ACT-01
9'-0" A.F.F.
5
5
GWB-X1
9'-0" A.F.F.
ALIGN
5
PT-10
PT-10 5
5
PT-10
5
PT-10PT-10PT-10 PT-10 PT-10
5 5 5 5 5
PT-10
5
GYB BOARD CEILING
(REFER TO PLAN FOR
SUSPENSION TYPE) PT-10 U.N.O.
ACOUSTIC CEILING TILE
2 x 4 LIGHT FIXTURE
4" APERTURE LED CIRCULAR DOWNLIGHT
DECORATIVE PENDANT -
GLOBAL LIGHTING ZERO 36"
CYLINDER PENDANT IN EXPOSED CEILING
SPOT ELEVATION MARKER
XXX-01
10'-10" A.F.F.
CEILING TAG
CEILING TYPE
CEILING HEIGHT
(ABOVE FINISH FLOOR)
UPGRADED PERFORATED METAL
PANELS
4" APERTURE LED SQUARE DOWNLIGHT
EXPOSED METAL OR
PRECAST CEILING
PT-10 U.N.O.
VERTICAL 1" APERTURE RECESSED
SLOT LIGHT
UNDER AND OVER CABINET LIGHTING
A. THESE GENERAL NOTES APPLY TO SERIES A-130
REFLECTED CEILING DRAWINGS.
B. INSTALL NEW CEILINGS AT HEIGHTS AND MATERIAL NOTED.
C. CENTER CEILING GRIDS WITHIN ROOMS EACH DIRECTION
UNLESS NOTED OTHERWISE.
D. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT
BORDERS CONTAIN NOT LESS THAN 1/2 TILE WIDTH,
UNLESS OTHERWISE INDICATED.
E. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS
WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER
HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS
OTHERWISE INDICATED.
F. PAINT EXPOSED GYPSUM BOARD AND PLASTER CEILING
SURFACES PT-10 UNLESS OTHERWISE INDICATED.
G. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD
CEILING CONSTRUCTION AS INDICATED. WHERE NOT
SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF
30'-0”. VERIFY FINAL CONTROL JOINT LOCATIONS WITH
ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
INDICATED ON THE DRAWINGS.
H. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED
TO LIMIT NUMBER OF PANELS REQUIRED. PANEL QUANTITY
SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS
WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY
FINAL LOCATIONS WITH ARCHITECT PRIOR TO STARTING
WORK.
I. REFER TO SERIES A-001 GENERAL INFORMATION
DRAWINGS FOR MATERIAL SYMBOL KEY.
J. REFER TO SERIES A-150 FINISH PLANS FOR ADDITIONAL
CEILING FINISH INFORMATION.
K. REFER TO ELECTRICAL DRAWINGS FOR CEILING-MOUNTED
LIGHT FIXTURE TYPES AND QUANTITIES.
L. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED
DIFFUSERS, GRILLE TYPES AND QUANTITIES.
M. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER
HEAD TYPES AND QUANTITIES. HEADS HAVE BEEN
INTENTIONALLY OMITTED FROM REFLECTED CEILING PLANS
FOR CLARITY.
N. INSTALLATION OF CEILING SYSTEMS SHALL NOT BEGIN
PRIOR TO SUBMITTAL AND REVIEW OF CEILING
COORDINATION DRAWINGS SHOWING LAYOUT OF CEILING
GRIDS OR CONTROL JOINTS AND ITEMS TO BE INSTALLED IN
OR ON CEILINGS SUCH AS SPRINKLER HEADS, DIFFUSERS,
GRILLES, LIGHT FIXTURES, FIRE DETECTION AND ALARM
DEVICES, ACCESS PANELS, ETC.
O. PROVIDE 4" AXIOM EDGE TRIM ON ALL EXPOSED EDGES OF
CEILINGS UNLESS NOTED OTHERWISE.
P. IN AREAS WHERE STRUCTURE IS EXPOSED, CONTRACTOR
TO PROVIDE FiNAL LAYOUTS OF ALL DUCTWORK, PIPING,
CONDUIT, LIGHTING, ETC. FOR FINAL APPROVAL BY
ARCHITECT PRIOR TO INSTALLATION. PAINT ALL EXPOSED
ELEMENTS AS INDICATED ON PLAN.
Q. PAINT ALL ELEMENTS ABOVE CLOUD CEILINGS WITHIN 6'-0"
OF PERIMETER INCLUDING BUT NOT LIMITED TO
DUCTWORK, STRUCTURE, CABLES, METAL STUDS, PIPING,
CEILING HANGERS, AND MECHANICAL DEVICES
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
F.A. Wilhelm Construction
3914 Prospect Street
Indianapolis, Indiana 46203
317-359-5411
Construction Manager
1/21/2022 4:35:03 PMA-131B
FIRST FLOOR
REFLECTED CEILING
PLAN - AREA B
21040.000
Republic Airways
Training Center
12195 N. Meridian St.
Carmel, Indiana
46032
1/8" = 1'-0"A-131B
A1 FIRST LEVEL RCP
1 BID EVENT #5 11/05/21
2 PERMIT SET 11/19/21
3 CD SET 12/17/21
4 BULLETIN SET 01/13/22
5 BULLETIN 2 01/20/22
01/20/22
RCP LEGEND
KEYNOTES (SPEC BASED)
KEYNOTES (ACTION/GENERAL)
GENERAL CEILING PLAN NOTES
02/23/22