Loading...
HomeMy WebLinkAboutA-132B-SECOND-FLOOR-REFLECTED-CEILING-PLAN---AREA-B-Rev.62 2 5 5 6 6 7 7 E E D D F F G G 4 4 H H 1 1 8 810"10"1'-6" 1'-6"EQ EQ 1'-6"1'-6"1'-6"EQEQ1'-0"J J ACT-01 8'-0" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F.ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-2" A.F.F. ACT-01 8'-9" A.F.F. ACT-01 8'-9" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F. ACT-03 10'-0" A.F.F. ACT-01 10'-3" A.F.F. GWB-X1 8'-6" A.F.F. 3 3 CTP/ UPGRADE/SYSTEMS/ RECURRENT 24 STUDENTS 207 VIRTUAL CLASSROOM 216 CTP/ UPGRADE/ SYSTEMS/ RECURRENT 24 STUDENTS 217 CTP/ UPGRADE SYSTEMS/ RECURRENT - 24 STUDENTS 218 CTP UPGRADE SYSTEMS/ RECURRENT - 24 STUDENTS 219 FLIGHT OPS 48 PEOPLE 220 NORTH CORRIDOR 214 BRIEF 212B DEBRIEF 212A BRIEF 211B DEBRIEF 211A BRIEF 210B DEBRIEF 210A BRIEF 209B DEBRIEF 209A BRIEF 208B DEBRIEF 208A ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F.ACT-01 9'-0" A.F.F. VPT 208 VPT 209 VPT 210 VPT 211 VPT 212 SOUTH CORRIDOR 204 SOUTH CORRIDOR 204 NORTH CORRIDOR 214 CORRIDOR 201B FLIGHT OPS 48 PEOPLE 221 CTP/ UPGRADE/ SYSTEMS/ RECURRENT 28 STUDENTS 203 LIFT CLASSROOM - 30 PEOPLE 202 NEW HIRE FLIGHT OPS 40 STUDENT ROOM 205 MEN 223 WOMEN 224 ADA 222 GENDER NEUTRAL 225 JAN 226 STAIR/ ENTRY 201 PT-10 PT-11 PT-11 PT-11 PT-11 GWB-X1 8'-6" A.F.F. UNDER AND OVER CABINET LIGHTING IN UPPER CABINETS PT-10 PT-10 PT-10 PT-10 2'-0" 4'-0" 2'-6" 1'-6"2'-0"3'-6"1'-0"1'-0"3'-6"GWB-X1 8'-2" A.F.F. ACT-01 9'-0" A.F.F. ACT-01 9'-0" A.F.F.GWB-X1 8'-0" A.F.F. GWB-X1 8'-0" A.F.F.2'-9"6" 9'-6" GWB-X1 8'-9" A.F.F. GWB-X1 8'-9" A.F.F. GWB-X1 8'-6" A.F.F. ACT-03 9'-0" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-0" A.F.F. GWB-X1 8'-0" A.F.F. GWB-X1 8'-2" A.F.F. ACT-03 8'-0" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-0" A.F.F. GWB-X1 8'-0" A.F.F. GWB-X1 8'-2" A.F.F. ACT-03 9'-0" A.F.F. ACT-03 9'-0" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-2" A.F.F.ALIGN10" GWB-X1 8'-0" A.F.F.ALIGN2'-5 3/8"ALIGN2'-0" G1 A-521 ALIGNEQ.2'-0" G1 A-521 5 7/16"G3 A-521 6"1'-10"6"GWB-X1 10'-0" A.F.F. E6 A-521 B1 A-521 A1 A-521 A3 A-521 B3 A-521 B1 A-521 TYPALIGNG3 A-521 G3 A-521D1 A-521 G1 A-521 G1 A-521 G3 A-521 G1 A-521 G3 A-521 ALIGNALIGNALIGNA1 A-521 6"4'-0"4'-0"2'-0"4'-0"ALIGNALIGN ALIGN G1 A-521 2'-0 5/8" 3'-3"4'-0"4'-0"WT-01 WT-01 WT-01 WT-01 GWB-X1 10'-7" A.F.F. A3 A-521 A3 A-521 GWB-X1 8'-2" A.F.F. WT-01 1'-1 7/8" 10" WT-01 WT-01 GWB-X1 8'-0" A.F.F. GWB-X1 8'-0" A.F.F. A3 A-521 ALIGN ALIGN ACT-03 9'-0" A.F.F. 1'-5" 1'-4"1 0 '-0"3'-0 1/8"3'-0"EQEQEQD5 A-521 D5 A-521 D5 A-521 D5 A-521 B1 A-521 B1 A-521 B1 A-521 GWB-X1 8'-2" A.F.F. GWB-X1 8'-2" A.F.F. GWB-X1 8'-2" A.F.F. ACT-03 8'-2" A.F.F. G1 A-521 2'-0" A3 A-5213'-9 7/16"G1 A-52110"PT-10 PT-10 WT-01 WT-01 PT-10 WT-01 GWB-X1 12'-0" A.F.F.ALIGN10" G3 A-521 G3 A-521 2'-9" A1 A-521 B1 A-521 GWB-X1 8'-9" A.F.F. GWB-X1 8'-6" A.F.F. GWB-X1 8'-6" A.F.F. 2'-4 7/8" GWB-X1 8'-2" A.F.F. GWB-X1 8'-6" A.F.F. EQEQACT-03 9'-0" A.F.F.ALIGN1'-0" 15'-4" SIM DOWNLIGHTS SHOWN IN CORRIDOR TO BE EQUALLY SPACED BETWEEN NORTH AND SOUTH.1'-10"EQ EQ 2'-3" 2'-3" 4'-0"4'-0"3'-6" 6'-0" 2 WT-01 PT-10 2 SIM SIM 2 2 GYB BOARD CEILING (REFER TO PLAN FOR SUSPENSION TYPE) PT-10 U.N.O. ACOUSTIC CEILING TILE 2 x 4 LIGHT FIXTURE 4" APERTURE LED CIRCULAR DOWNLIGHT DECORATIVE PENDANT - GLOBAL LIGHTING ZERO 36" CYLINDER PENDANT IN EXPOSED CEILING SPOT ELEVATION MARKER XXX-01 10'-10" A.F.F. CEILING TAG CEILING TYPE CEILING HEIGHT (ABOVE FINISH FLOOR) UPGRADED PERFORATED METAL PANELS 4" APERTURE LED SQUARE DOWNLIGHT EXPOSED METAL OR PRECAST CEILING PT-10 U.N.O. VERTICAL 1" APERTURE RECESSED SLOT LIGHT UNDER AND OVER CABINET LIGHTING A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS. B. INSTALL NEW CEILINGS AT HEIGHTS AND MATERIAL NOTED. C. CENTER CEILING GRIDS WITHIN ROOMS EACH DIRECTION UNLESS NOTED OTHERWISE. D. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS THAN 1/2 TILE WIDTH, UNLESS OTHERWISE INDICATED. E. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE INDICATED. F. PAINT EXPOSED GYPSUM BOARD AND PLASTER CEILING SURFACES PT-10 UNLESS OTHERWISE INDICATED. G. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT INDICATED ON THE DRAWINGS. H. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK. I. REFER TO SERIES A-001 GENERAL INFORMATION DRAWINGS FOR MATERIAL SYMBOL KEY. J. REFER TO SERIES A-150 FINISH PLANS FOR ADDITIONAL CEILING FINISH INFORMATION. K. REFER TO ELECTRICAL DRAWINGS FOR CEILING-MOUNTED LIGHT FIXTURE TYPES AND QUANTITIES. L. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED DIFFUSERS, GRILLE TYPES AND QUANTITIES. M. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD TYPES AND QUANTITIES. HEADS HAVE BEEN INTENTIONALLY OMITTED FROM REFLECTED CEILING PLANS FOR CLARITY. N. INSTALLATION OF CEILING SYSTEMS SHALL NOT BEGIN PRIOR TO SUBMITTAL AND REVIEW OF CEILING COORDINATION DRAWINGS SHOWING LAYOUT OF CEILING GRIDS OR CONTROL JOINTS AND ITEMS TO BE INSTALLED IN OR ON CEILINGS SUCH AS SPRINKLER HEADS, DIFFUSERS, GRILLES, LIGHT FIXTURES, FIRE DETECTION AND ALARM DEVICES, ACCESS PANELS, ETC. O. PROVIDE 4" AXIOM EDGE TRIM ON ALL EXPOSED EDGES OF CEILINGS UNLESS NOTED OTHERWISE. P. IN AREAS WHERE STRUCTURE IS EXPOSED, CONTRACTOR TO PROVIDE FiNAL LAYOUTS OF ALL DUCTWORK, PIPING, CONDUIT, LIGHTING, ETC. FOR FINAL APPROVAL BY ARCHITECT PRIOR TO INSTALLATION. PAINT ALL EXPOSED ELEMENTS AS INDICATED ON PLAN. Q. PAINT ALL ELEMENTS ABOVE CLOUD CEILINGS WITHIN 6'-0" OF PERIMETER INCLUDING BUT NOT LIMITED TO DUCTWORK, STRUCTURE, CABLES, METAL STUDS, PIPING, CEILING HANGERS, AND MECHANICAL DEVICES SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 F.A. Wilhelm Construction 3914 Prospect Street Indianapolis, Indiana 46203 317-359-5411 Construction Manager 1/14/2022 11:11:27 AMA-132B SECOND FLOOR REFLECTED CEILING PLAN-AREA B 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/8" = 1'-0"A-132B B1 CLNG-Second Level -Area B 1 PERMIT SET 11/19/21 2 BULLETIN SET 01/13/22 01/13/22 RCP LEGEND KEYNOTES (SPEC BASED) KEYNOTES (ACTION/GENERAL) GENERAL CEILING PLAN NOTES 02/23/22