HomeMy WebLinkAboutA-133A-THIRD-FLOOR-REFLECTED-CEILING-PLAN---AREA-A-Rev.52
2
5
5
6
6
7
7
A A
D D
B B
C C
4
4
1
1
8
8
2
3
ACT-03
9'-0" A.F.F.
ACT-03
10'-0" A.F.F.
GWB-X1
9'-3" A.F.F.
ACT-01
10'-0" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-6" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-0" A.F.F.
ACT-01
9'-6" A.F.F.
3
3 10"10"GWB-X1
10'-1" A.F.F.
6"6"10"ACT-03
9'-0" A.F.F.
GWB-X1
11'-0 3/8" A.F.F.
GWB-X2
10'-0" A.F.F.
GWB-X1
9'-0" A.F.F.
IN-FLIGHT
NEW HIRE 30
STUDENTS
314
IN-FLIGHT
NEW HIRE 30
STUDENTS
313
IN-FLIGHT
NEW HIRE 30
STUDENT
312
IN-FLIGHT
NEW HIRE 24
STUDENT
311
IN-FLIGHT
NEW HIRE 30
STUDENTS
310
SOUTH
CORRIDOR
308
STAIR 03
S-003
WEST
CORRIDOR
319
OPEN OFFICE
- 78 DESKS
304
EVPT
307
BRIEF
307B
DEBRIEF
307A
BRIEF
306B
EVPT
306
DEBRIEF
306A
EAST
CORRIDOR
302
OPEN OFFICE
-78 DESKS
304
EVPT
305
DEBRIEF
305A
BRIEF
305B
TELECOM
303
STG
300A
STAIR
301
ACT-03
9'-0" A.F.F.
PT-11
7'-0 1/8"
2'-5"
EQ EQ
GWB-X1
8'-2" A.F.F.1'-5 3/4"4'-0"3'-11 13/16"2'-0"GWB-X1
9'-3" A.F.F.
GWB-X1
9'-3" A.F.F.
1 '-4"1'-5"10'-0"G1
A-521
E1
A-521
A3
A-521
A3
A-521
GWB-X1
11'-0 3/8" A.F.F.
WT-01
PT-10
PT-10
WT-01
PT-10
A3
A-521
ACT-01
9'-6" A.F.F.
PT-10
PT-10
WT-01
WT-01
G3
A-521
ACT-03
9'-0" A.F.F.
ACT-03
9'-0" A.F.F.
WT-01
PT-10
PT-10
WT-01
6"
A3
A-521
A3
A-521
A3
A-521
PT-10 WT-01 WT-01WT-01EQEQWT-01WT-01WT-01D5
A-521
PT-11
D5
A-521
D5
A-521
D5
A-521
7'-11 1/2"
9'-6"
EQ EQ.
A3
A-521
GWB-X1
9'-0" A.F.F.
GWB-X1
9'-6" A.F.F.
A3
A-521
SIM
ALIGNGWB-X1
8'-2" A.F.F.
GWB-X1
11'-6" A.F.F.
GWB-X1
10'-0" A.F.F.
B3
A-521
F3
A-521
SIM
ALIGN3'-10"EQ EQ
EQACT-01
9'-0" A.F.F.
GWB-X1
11'-0 3/8" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-1" A.F.F.
ACT-01
9'-1" A.F.F.ACT-01
9'-1" A.F.F.
CONF
309E
CONFERENCE
309F
CONF
309G
OFFICE
309D
OFFICE
309C
OFFICE
309B
OFFICE
309A
ACT-01
9'-1" A.F.F.
ACT-01
9'-1" A.F.F.
GWB-X1
9'-0" A.F.F.
GWB-X1
9'-0" A.F.F.
GWB-X1
10'-1" A.F.F.
GWB-X1
9'-0" A.F.F.
GWB-X1
9'-0" A.F.F.
GWB-X1
10'-1" A.F.F.
GWB-X1
9'-0" A.F.F.
GWB-X1
10'-1" A.F.F.
GWB-X1
9'-0" A.F.F.
WT-01
STAIR
301
CONFERENCE
300STAIR
301
GYB BOARD CEILING
(REFER TO PLAN FOR
SUSPENSION TYPE) PT-10 U.N.O.
ACOUSTIC CEILING TILE
2 x 4 LIGHT FIXTURE
4" APERTURE LED CIRCULAR DOWNLIGHT
DECORATIVE PENDANT -
GLOBAL LIGHTING ZERO 36"
CYLINDER PENDANT IN EXPOSED CEILING
SPOT ELEVATION MARKER
XXX-01
10'-10" A.F.F.
CEILING TAG
CEILING TYPE
CEILING HEIGHT
(ABOVE FINISH FLOOR)
UPGRADED PERFORATED METAL
PANELS
4" APERTURE LED SQUARE DOWNLIGHT
EXPOSED METAL OR
PRECAST CEILING
PT-10 U.N.O.
VERTICAL 1" APERTURE RECESSED
SLOT LIGHT
UNDER AND OVER CABINET LIGHTING
A. THESE GENERAL NOTES APPLY TO SERIES A-130
REFLECTED CEILING DRAWINGS.
B. INSTALL NEW CEILINGS AT HEIGHTS AND MATERIAL NOTED.
C. CENTER CEILING GRIDS WITHIN ROOMS EACH DIRECTION
UNLESS NOTED OTHERWISE.
D. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT
BORDERS CONTAIN NOT LESS THAN 1/2 TILE WIDTH,
UNLESS OTHERWISE INDICATED.
E. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS
WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER
HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS
OTHERWISE INDICATED.
F. PAINT EXPOSED GYPSUM BOARD AND PLASTER CEILING
SURFACES PT-10 UNLESS OTHERWISE INDICATED.
G. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD
CEILING CONSTRUCTION AS INDICATED. WHERE NOT
SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF
30'-0”. VERIFY FINAL CONTROL JOINT LOCATIONS WITH
ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT
INDICATED ON THE DRAWINGS.
H. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED
TO LIMIT NUMBER OF PANELS REQUIRED. PANEL QUANTITY
SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS
WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY
FINAL LOCATIONS WITH ARCHITECT PRIOR TO STARTING
WORK.
I. REFER TO SERIES A-001 GENERAL INFORMATION
DRAWINGS FOR MATERIAL SYMBOL KEY.
J. REFER TO SERIES A-150 FINISH PLANS FOR ADDITIONAL
CEILING FINISH INFORMATION.
K. REFER TO ELECTRICAL DRAWINGS FOR CEILING-MOUNTED
LIGHT FIXTURE TYPES AND QUANTITIES.
L. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED
DIFFUSERS, GRILLE TYPES AND QUANTITIES.
M. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER
HEAD TYPES AND QUANTITIES. HEADS HAVE BEEN
INTENTIONALLY OMITTED FROM REFLECTED CEILING PLANS
FOR CLARITY.
N. INSTALLATION OF CEILING SYSTEMS SHALL NOT BEGIN
PRIOR TO SUBMITTAL AND REVIEW OF CEILING
COORDINATION DRAWINGS SHOWING LAYOUT OF CEILING
GRIDS OR CONTROL JOINTS AND ITEMS TO BE INSTALLED IN
OR ON CEILINGS SUCH AS SPRINKLER HEADS, DIFFUSERS,
GRILLES, LIGHT FIXTURES, FIRE DETECTION AND ALARM
DEVICES, ACCESS PANELS, ETC.
O. PROVIDE 4" AXIOM EDGE TRIM ON ALL EXPOSED EDGES OF
CEILINGS UNLESS NOTED OTHERWISE.
P. IN AREAS WHERE STRUCTURE IS EXPOSED, CONTRACTOR
TO PROVIDE FiNAL LAYOUTS OF ALL DUCTWORK, PIPING,
CONDUIT, LIGHTING, ETC. FOR FINAL APPROVAL BY
ARCHITECT PRIOR TO INSTALLATION. PAINT ALL EXPOSED
ELEMENTS AS INDICATED ON PLAN.
Q. PAINT ALL ELEMENTS ABOVE CLOUD CEILINGS WITHIN 6'-0"
OF PERIMETER INCLUDING BUT NOT LIMITED TO
DUCTWORK, STRUCTURE, CABLES, METAL STUDS, PIPING,
CEILING HANGERS, AND MECHANICAL DEVICES
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
F.A. Wilhelm Construction
3914 Prospect Street
Indianapolis, Indiana 46203
317-359-5411
Construction Manager
12/17/2021 2:23:28 PMA-133A
THIRD FLOOR
REFLECTED CEILING
PLAN -AREA A
21040.000
Republic Airways
Training Center
12195 N. Meridian St.
Carmel, Indiana
46032
1/8" = 1'-0"A-133A
A1 CLNG-Third Level -Area A
1 PERMIT SET 11/19/21
11/19/21
RCP LEGEND
KEYNOTES (SPEC BASED)
KEYNOTES (ACTION/GENERAL)
GENERAL CEILING PLAN NOTES
02/23/22