Loading...
HomeMy WebLinkAboutA-411-ENLARGED-RESTROOM-PLANS-Rev.9A. REFERENCE STANDARD PLUMBING FIXTURE REQUIREMENTS AND STANDARD TOILET TOOM ACCESSORY MOUNTING HEIGHTS ON A-001 FOR ADDITIONAL INFORMATION UNLESS OTHERWISE NOTED. B. REFERENCE STANDARD TOILET COMPARTMENTS - TYPICAL ACCESSORIES ON A-002 FOR TOILET ROOM ACCESSORIES LOCATED IN STALLS. 7 E 08B 08A 08A 08A 08B 08B 08A 06A 06A 06A 06A 06A A AB C C C C C WOMEN 121 MEN 120 ADA 119 GENDER NEUTRAL 122 JAN 123 8 A-501 B6 A-412A6 A-412 A3 A-412 C6 B1 A1 B3 06A C3 D6 C1 B4 A-412 F3 F5 F6 D1 A-413 A2 A1 A6 A4 8'-5 7/8" 1'-6" MIN. 1'-0" MIN. 4'-1 5/8" 32'-0 7/16"5'-9 15/16"06A 08A 08A08A 01A 07A 07A 01A 01A 06A 08A A C A1 A-3542'-0"01A HALL 119 2'-8 11/16" 3'-0 7/16" 33'-6 15/16" 1'-11 5/8"5'-2 3/4"1'-8 9/16"1'-11 7/16"2'-9 7/8"4'-11 1/8"8'-8 3/4" 3'-1" 3'-1" 3'-1" 3'-0" 3'-1"5'-7"4'-11"2'-2"1'-11 1/8"7'-1"6'-11 3/8"ALIGN 08B3'-5"3'-5"4'-8"8'-0 7/8"2'-7 1/2" 2'-7" 2'-7" 3'-1" 5'-7" 2'-2 15/16"3'-0"1'-6 11/16"REFERENCE 2ND FLOOR ARCHITECTURAL FLOOR PLAN FOR REQUIRED EXHAUST CHASE AND DOOR SIZE ON THAT FLOOR 1'-6" A-412 D4 2'-6 29/32" FLOOR STOP REQUIRED 09A 09A 2 2 12B 3 7 7 E E WOMEN 320 JAN 322 GENDER NEUTRAL 321 ADA 317 MEN 319 A-413 D6 C1 C2 A-413 C6 C4 A-413D1 E4 A-413 D4 E2 E6 D2 9'-7 1/2" A-412 F6 A-412 F3 A-412F5A-412 D1 TYP SIM TYP SIM A-413 A4 A-413 A2 A-413 A6A-413 A1 TYP TYPTYP TYP 1'-6" MIN. 6" 318317 321 320 2'-1"6'-0 7/8"1'-9 5/8"3'-5 3/4" 3'-8 7/8"22'-5 19/32" 08A 06A A C C C A A C 08A 08A 08A 08A 06A 06A 06A 06A 1'-6 1/4"3'-0"1'-3"01A 01A 09A 07A 3'-1" 3'-0" 3'-0"6"6"6"6"3'-5"1'-0" MIN. 3'-6"01A 4'-8"07A 3'-5"6" 6" 5'-10 1/2"2'-7" 2'-7"5'-9"1'-6"2'-0"08B 01A 4'-4" 9'-6 1/4" 5'-5 1/16"6'-6 1/4"5'-0 9/16"9'-9"6'-11 7/8"6'-8"1'-10 1/2"2'-6 1/4"4'-3"8'-4 1/8"3'-2"01A C7 A-402 2'-6 9/16" FLOOR STOP REQUIRED 08B 09A 2 2 08B 2 12B 7 7 E E W B F CT-01 CT-10 CT-01 MEN 319 W B F CT-01 CT-10 CT-01 WOMEN 320 W B F JAN 322 RB-01 CONC-01 FRP-01 W B F CT-01 CT-10 CT-01 ADA 317 W B F CT-01 CT-10 CT-01 GENDER NEUTRAL 321 REF. ELEV. REF. ELEV. 2 2 2'-0"EQEQ3 7 7 E E 8 8 W B F CT-01 CT-10 CT-01 MEN 120 W B F CT-01 CT-10 CT-01 WOMEN 121 W B F CT-01 CT-10 CT-01 GENDER NEUTRAL 122 W B F JAN 123 RB-01 CONC-01 FRP-01 A1 A-354 CONTINUOUS TILE PATTERN EQEQEQEQREFERENCE ELEVATIONS FOR SPECIFIC WALL FINISHES AND LOCATIONS OF TRANSITIONS FROM CT-01 TO WC-01 2 REFERENCE ELEVATIONS FOR SPECIFIC WALL FINISHES AND LOCATIONS OF TRANSITIONS FROM CT-01 TO WC-01 2 REF. ELEVATIONS W B F CT-01 CT-10 CT-01 ADA 119 REF. ELEVATIONS 2 2 2'-0" 3 SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 F.A. Wilhelm Construction 3914 Prospect Street Indianapolis, Indiana 46203 317-359-5411 Construction Manager 1/14/2022 11:07:10 AMA-411 ENLARGED RESTROOM PLANS 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 KEYNOTES (SPEC BASED) REFER TO SHEET A-002 FOR TOILET COMPARTMENT TYPES AND ACCESSORIES TOILET ROOM ACCESSORIES TAG DESCRIPTION MFR MODEL NO. 01A PAPER TOWEL DISPENSER/WASTE RECEPTACLE, RECESSED, INCLUDE LINER BOBRICK B-3803 02A WASTE RECEPTACLE, RECESSED, INCLUDE LINER BOBRICK B-35633 03A TOILET TISSUE HOLDER, 2 STANDARD ROLL BOBRICK B-3588 03C SEAT COVER DISPENSER, SURFACE MOUNTED BOBRICK B-221 03F TOILET TISSUE/SANITARY NAPKIN DISPOSAL/SEAT COVER DISPENSER, RECESSED BOBRICK B-3013 04A SANITARY NAPKIN DISPOSAL, SURFACE MOUNTED BOBRICK B-35139 05A GRAB BAR, 42" BOBRICK B9806 x 42 05B GRAB BAR, 36" BOBRICK B-9806 x 36 05D GRAB BAR, 18" BOBRICK B-9806 x 18 05E GRAB BAR, 12" BOBRICK B-9806 x 12 05F GRAB BAR, 30" BOBRICK B-9806 x 30 06A SOAP DISPENSER, COUNTERTOP MOUNTED SLOAN ESD-701-CP 07A Wall Mounted Hand Dryer Dyson Dyson Airblade V AB12 Nickel 08A MIRROR, ABOVE COUNTERTOP POTTERY BARN KENSINGTON 20"X42" WARM BRONZE 08B MIRROR, FULL HEIGHT, CUSTOM PER SPECIFICATIONS N/A 09A CLOTHES HOOK BOBRICK B-7672 12A JANITOR'S CLOSET SHELF, 18" W BOBRICK B-295x18 12B JANITOR'S CLOSET SHELF, 24" W BOBRICK B-295x24 12C MOP AND BROOM HOLDER BOBRICK B-223x24 13A FOLDING SHOWER SEAT BOBRICK B-5181 GENERAL TOILET ROOM NOTES 1/4" = 1'-0"A-411 A1 FIRST AND SECOND LEVEL ENLARGED RESTROOM PLANS, TYPICAL 1/4" = 1'-0"A-411 D1 ENPLN -THIRD LEVEL RESTROOMS 1/4" = 1'-0"A-411 D4 THIRD LEVEL RESTROOMS ENLARGED FINISH PLAN 1/4" = 1'-0"A-411 A4 RESTROOMS TYPICAL ENLARGED FINISH PLAN 1 PERMIT SET 11/19/21 2 CD SET 12/17/21 3 BULLETIN SET 01/13/22 01/13/22 2 REFERENCE ELEVATIONS FOR SPECIFIC WALL FINISHES AND TRANSITIONS FROM CT-01 TO WC-01 2 REFERENCE ELEVATIONS FOR SPECIFIC WALL FINISHES AND TRANSITIONS FROM CT-01 TO WC-01 2 3 02/23/22