HomeMy WebLinkAboutA-521-CEILING-DETAILS-Rev.6SUSPENDED
ACOUSTICAL TILE
CORNER BEAD
(1) LAYER 5/8" GYP BD
ON MTL STUDS
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
PER RCP
ADDITIONAL FRAMING AS
REQUIRED FOR LARGER
WIDTHS
REFER
TO
RCP
REFER
TO
RCP
REFER
TO
RCP
SHADOW REVEAL
SUSPENDED
ACOUSTICAL TILE
CORNER BEAD
(1) LAYER 5/8" GYP BD
ON MTL STUDS
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
ALIGNPER RCP
ADDITIONAL FRAMING AS
REQUIRED FOR LARGER WIDTHS
REFER
TO
RCP
REFER
TO
RCP
CORNER BEAD
FRAMING AND
BRACING PER
SPECIFICATIONS
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
ADDITIONAL FRAMING AS
REQUIRED FOR LARGER
WIDTHS
REFER
TO
RCP
CORNER BEAD
FRAMING AND BRACING
PER SPECIFICATIONS4"6"
REFER TO RCP
REFER
TO
RCP
REFER
TO
RCP 2"CORNER BEAD
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
FRAMING AND
BRACING PER
SPECIFICATIONS
REFER
TO
RCP
REFER
TO
RCP
GYP. BD. CEILING
ON SUSPENSION
SYSTEM AS
SCHEDULED
CASING BEAD
PAINT EXPOSED WALL PER FINISH PLAN
LIGHT FIXTURE
HOUSING
SCHEDULED
WALL TILE
ALUMINUM PERIMETER
TRIM BY CEILING MFG
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
FRAMING AND
BRACING PER
SPECIFICATIONS
PER RCPPERIMETER TRIM
REFER
TO
RCP
REFER
TO
RCP
PERIMETER TRIM
SUSPENDED
ACOUSTICAL
CEILING
CORNER BEAD
RCP
PER
PAINT GWB PER FINISH PLAN
ADDITIONAL FRAMING AS
REQUIRED FOR LARGER
WIDTHS
REFER
TO
RCP
DRYWALL MAIN
BEAM
LIGHT FIXTURE
SUPPORTED AS REQUIRED
PER FINAL SPECIFICATION METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
HANGER WIRE TO
STRUCTURE
VERTICAL RISERS
KAM
3
SUSPENDED
ACOUSTICAL TILE
CORNER BEAD
(1) LAYER 5/8" GYP BD
ON MTL STUDS
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
ALIGN
ADDITIONAL FRAMING
AS REQUIRED FOR
LARGER WIDTHS
REFER
TO
RCP
PERIMETER TRIM
SUSPENDED
ACOUSTICAL
CEILING
VERTICAL PORTION OF
BULKHEAD, OR WALL
AS SCHEDULED
RCP
PER
PAINT GWB PER
FINISH PLAN
REFER
TO
RCP
CORNER BEAD
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
FRAMING AND
BRACING PER
SPECIFICATIONS
REFER
TO
RCP
EXTEND FRAMING AND
DRYWALL TO EXPOSED
SLAB. DRYWALL MUST BE
FINISHED AT TRANSITION
TO ENABLE CRISP PAINT
CUT LINE.
CORNER BEAD
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
FRAMING AND
BRACING PER
SPECIFICATIONS
REFER
TO
RCP
SMOKE BAFFLE GLASS -
FRAMELESS BUTT JOINTS IN EQUAL
SEGMENTS OF LARGEST WIDTH
PERMITTABLE PER SPECS
REF RCP
CRL BLUMCRAFT TWO PIECE
SMOKE BAFFLE TRIM SYSTEM
ATTACHED TO BLOCKING AND
FRAMING AS REQUIRED.1'-6"CORNER BEAD
FRAMING AND
BRACING PER
SPECIFICATIONS
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
ADDITIONAL FRAMING AS
REQUIRED FOR LARGER
WIDTHS
REFER
TO
RCP REFER
TO
RCP
CORNER BEAD
FRAMING AND BRACING PER
SPECIFICATIONS TO CREATE
HORIZONTAL OVERHANG.
SUPPORT ON SIDES AS REQUIRED
SUCH THAT NO EXTRANEOUS
SUPPORTS ARE VISIBLE.
REFER
TO
RCP
EXTEND FRAMING AND DRYWALL TO
EXPOSED SLAB. DRYWALL MUST BE
FINISHED AT TRANSITION TO ENABLE
CRISP PAINT CUT LINE.8"WALL SEEN BEYOND
LIGHTING AS INDICATED ON PLANS
6" STUD WALL REQUIRED TO SUPPORT
CANTILEVER
3
CORNER BEAD
FRAMING AND BRACING PER
SPECIFICATIONS TO
ENCLOSE MOVEABLE WALL
STRUCTURAL ELEMENTS
METAL STUD BRACING TO
STRUCTURE (AS REQUIRED
PER SPECIFICATIONS)
ADDITIONAL FRAMING AS
REQUIRED FOR LARGER
WIDTHS
REFER
TO
RCP
EXTEND STUD, DRYWALL AND
ACOUSTICAL INSULATION TO
DECK AND SEAL AS NEEDED
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
F.A. Wilhelm Construction
3914 Prospect Street
Indianapolis, Indiana 46203
317-359-5411
Construction Manager
1/14/2022 11:05:34 AMA-521
CEILING DETAILS
21040.000
Republic Airways
Training Center
12195 N. Meridian St.
Carmel, Indiana
46032
KEYNOTES (SPEC BASED)
1" = 1'-0"A-521
E1 CEILING AT BULKHEAD
1" = 1'-0"A-521
D1 CEILING AT BULKHEAD
1" = 1'-0"A-521
B1 CEILING AT BULKHEAD
1" = 1'-0" A-521
C6 CEILING AT GWB/ACT
1" = 1'-0" A-521
G3 CEILING AT GWB/ACT
3" = 1'-0"A-521
D3 ACCENT WALL
1" = 1'-0" A-521
E6 CEILING AT GWB/ACT (ACT LOWER)
1" = 1'-0"A-521
A1 CEILING AT ACCENT CLOUD
1" = 1'-0"A-521
G1 DRYWALL LID TO FLUSH ACT
1" = 1'-0" A-521
D5 CEILING AT ACT COVE at PLEATED WALLS
1" = 1'-0"A-521
F3 CEILING AT GWB/DECK
1" = 1'-0"A-521
B3 CEILING AT GWB -STAIR
1" = 1'-0"A-521
A3 CEILING AT BULKHEAD
1" = 1'-0"A-521
F5 CEILING AT GWB CANOPY
1 PERMIT SET 11/19/21
2 CD SET 12/17/21
3 BULLETIN SET 01/13/22
01/13/22
2
2
2
1" = 1'-0"A-521
A5 CEILING AT BULKHEAD WITH INSULATION
02/23/22