Loading...
HomeMy WebLinkAboutCDR - Project 426429 (MEPFA)ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on: February 4, 2022 Project number Release date 426429 02/04/22 Construction type Occupancy classification Scope of release *SEE BELOW *SEE BELOW Type of release Project name Street address City County ELEC FA MECH PLUM Partial Republic Airways Training Center & Hotel 12195 N Meridian St CARMEL HAMILTON To: Owner / Architect / Engineer DEEM Cameron T Yamashita PE11400027 6832. E. 32nd St. Indianapolis IN 46226 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 4G0603AR 14B0907 14W09077 9E11026A 14M0306 4G0604A ** CONSTRUCTION TYPE / OCCUPANCY: Existing Hotel - II-B / R1, A2, EXST Addition (Podium) - I-A / A-3, B Addition (Hotel) - II-B / R-2 Training Center - II-B / B ** This release does not include all scopes of construction work. Plans and specifications for adding or remodeling other systems shall be filed as a new project or as one or more partials before commencing work in accordance with 675 IAC 12-6-3. The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in accordance with Section 907, IBC (675 IAC 13-2.6). Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system shall be made. All functions of the system or alteration shall be tested in accordance with Section 907.7, IFC (675 IAC 22-2.5). Access and working space shall be provided and maintained about all electric equipment in accordance with Section 110.26, IEC (675 IAC 17-1.8). Access and service space for equipment and appliances shall be in accordance with Section 306, IMC (675 IAC 18-1.6). An application for storage facilities for flammable and combustible liquids and gases, with appropriate plans and fees, shall be filed in accordance with 675 IAC 12-6-4(a). NOTE: Fuel storage associated with emergency generator. Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3178602964, cyamashita@deemfirst.com 02/23/22 ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 14B101163 14M0920 4G0607AB 14B0404 14B071727 AREL Exit illumination and exit signs shall be connected to a separate emergency power source in accordance with Section 1011.6.3, IBC (675 IAC 13-2.6). NOTE: Exterior landings as required by Section 1008.1.6, IBC, for exit discharge doorways in buildings required to have two or more exits shall be illuminated at all times the building space served by the means of egress is occupied and shall in the event of power supply failure have an emergency electrical system that shall automatically illuminate the exterior landings in accordance with Sections 1006.1 & 1006.3, IBC. Suspended-type unit heaters shall be installed and supported in accordance with Section 920, IMC (675 IAC 18-1.6). This release does not include any plans marked as "Preliminary", "Not For Construction", "For Reference Only", "Future", or "Optional" in accordance with 675 IAC 12-6-7(b). NOTE: such as E--508. Atriums shall be designed and constructed in accordance with Section 404, IBC (675 IAC 13-2.6). Fire dampers, smoke dampers, combination fire/smoke dampers, and ceiling radiation dampers shall be provided in accordance with Section 717.2 through Section 717.7, IBC (675 IAC 13-2.6). NOTE: Atrium smoke control system shall comply with IMC Section 513, including fire alarm system activation per IFC 907.2.14 NOTE: Atrium Fire Suppression shall comply with IFC 914.4.1. Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. This order is effective upon service. If you would like to request informal review of this order, please complete the informal review form located at https://www.in.gov/dhs/4149.htm. Following receipt of this form, the Department may modify or reverse the order, however, a request for an informal review does not extend the deadline for filing a petition for review with the Fire Prevention and Building Safety Commission (Commission). Additionally, if you have any questions regarding this order, you may contact that Department at (317) 232-2222. If you desire a formal administrative review of this order by the Commission, you must comply with the requirements of Indiana Code § 4-21.5-3-7 and file a written petition for review within 15 days of the date this order was served, however, this period is extended to 18 days if service is made by mail. Your petition for review must state facts demonstrating that you are: (1) a person to whom the order is specifically directed; (2) aggrieved or adversely affected by the order; or (3) entitled to review under any law. You may submit your petition by the following methods: U.S. MAIL OR PERSONAL SERVICE ONLINE Fire Prevention and Building Safety Commission By completing the form at c/o Legal Counsel https://www.in.gov/dhs/4148.htm 302 W. Washington Street, Rm. E208 Indianapolis, IN 46204 For additional information about the administrative review process and applicable templates that may be used for filings, visit the following link https://www.in.gov/dhs/appeals.htm. Code review official Address (name,title of local official,street,city,state and ZIP code LARRY DAVIS JIM BLANCHARD ONE CIVIC SQUARE CARMEL, IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Indiana State Building Commissionerldavis2@dhs.in.gov 02/23/22