Loading...
HomeMy WebLinkAboutM-001-SYMBOLS-AND-ABBREVIATIONS-Rev.9SA BDD CO2 H T SP SD U M G L A#6 AV MV G M M PI S PT FD M P P P FTS PT TDS PH VB FM LC LS FS C.O. FLS LS PS TT T A∅A∅ CFMXX-X F.C.O. M DPT DP 3 2 1 # X X # XXX X # NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECT SHEET METAL CONNECTION STANDARDS REFER TO NOTES FOR LINING OR DOUBLE WALL LOCATIONS. ACCESS DOOR (A.D.). FIELD LOCATE ACCESS DOOR TO ENSURE ACCESS. ACCESS TO ALL FIRE, SMOKE AND FIRE/SMOKE DAMPERS IS REQUIRED, EVEN IF NO ACCESS DOOR IS SHOWN. COMBINATION FIRE & SMOKE DAMPER. RECTANGULAR DUCT RISING. 90° MITERED ELBOW W/ TURNING VANES. RADIUSED ELBOWS ARE PREFERRED WHENEVER POSSIBLE. FLEXIBLE DUCT. MIN. LENGTH 3 FT. MAX. LENGTH 6 FT RADIUS = 1 1 /2 TIMES DIAMETER OR WIDTH. VAV TERMINAL UNIT. 90° LONG RADIUS ELBOW. FLAT OVAL DUCT RISING. TYPICAL AIR HANDLING UNIT. BRACE FLAT OVAL DUCT. S/A DUCT TURNING DOWN THEN BACK TO HORIZONTAL. S/A DUFFUSERS ARE 4-WAY UNLESS NOTED OTHERWISE. ROUND DUCT RISING.ADJUSTABLE VANED EXTRACTOR. MANUAL VOLUME DAMPER. S/A GRILLE INSTALLED IN REGISTER BOX IN EXPOSED, ROUND DUCTWORK.A∅A∅A/BA/BAxBA∅A∅A/BA/BAxBAxBAxBA∅AxB1 2 3 3 DIAMETER MINIMUM LENGTH AT VAV INLET. FLEXIBLE DUCT. MIN. LENGTH 3 FT. MAX. LENGTH 6 FT 90° SHEET METAL ELBOW 90° SHEET METAL ELBOW PLAN NOTES: ROUND DUCT SIZE IN INCHES. NUMBER - DIAMETER OF ROUND DUCT. (INSIDE CLEAR DIMENSIONS). RECTANGULAR DUCT SIZE IN INCHES. 1 ST NUMBER - DIMENSION IN PLANE OF VIEW. 2ND NUMBER - DIMENSION PERPENDICULAR TO VIEW. (INSIDE CLEAR DIMENSIONS). FLAT OVAL DUCT SIZE IN INCHES. 1 ST NUMBER - DIMENSION IN PLANE OF VIEW. 2ND NUMBER - DIMENSION PERPENDICULAR TO VIEW. (INSIDE CLEAR DIMENSIONS). 45° KICKERS FOR RECTANGULAR DUCT. HVAC SYMBOLS DENOTES SPRIAL DUCT. SINGLE LINE ROUND DUCT CONTINUATION. SINGLE OR DOUBLE LINE RECTANGULAR MOTORIZED DAMPER. MOTORIZED DAMPER (ELEVATION). DOUBLE LINE ROUND DUCT CONTINUATION. CFM TAG. DOOR LOUVER. DOOR GRILLE. AIRFLOW ARROW. AIRFLOW ARROW. ALARM. C02 SENSOR. HUMIDISTAT. THERMOSTAT. STATIC PRESSURE SENSOR. SMOKE DETECTOR. ACCESS DOOR. UNDERCUT DOOR. BACKDRAFT DAMPER. VOLUME DAMPER. SOUND ATTENUATOR. FIRE DAMPER (VERTICAL). SMOKE DAMPER (VERTICAL). FIRE-SMOKE DAMPER (VERTICAL). FIRE DAMPER (HORIZONTAL). SMOKE DAMPER (HORIZONTAL). FIRE-SMOKE DAMPER (HORIZONTAL). O/A ROOF PLAN (SHOWING EXHAUST DUCT IN FLOOR SPACE BELOW). O/A INTAKE DUCT IN FLOOR PLAN. EXHAUST FAN ON ROOF PLAN (SHOWING EXHAUST DUCT IN FLOOR SPACE BELOW). EXHAUST FAN IN FLOOR PLAN (SHOWING EXHAUST FAN HOOD ON ROOF ABOVE). EXHAUST FAN HOOD. VVT. 24x24 R/A GRILLE W/ ROUND INTERNALLY INSULATED FLEX BOOT. 24x24 R/A GRILLE W/ RECTANGULAR INTERNALLY INSULATED BOOT. 24x24 R/A GRILLE. 24x24 S/A DIFFUSER W/ 1 0" FLEX DUCT. 1 2x1 2 S/A DIFFUSER W/ 8" FLEX DUCT. 48x4 S/A SLOT DIFFUSER. 24x4 S/A SLOT DIFFUSER. R/A LONG 90° RECTANGULAR ELBOW (DOWN). R/A LONG 90° RECTANGULAR ELBOW (UP). S/A LONG 90° RECTANGULAR ELBOW (DOWN). LONG 90° ROUND ELBOW (DOWN). S/A LONG 90° RECTANGULAR ELBOW (UP). LONG 90° ROUND ELBOW (UP). E/A LONG 90° RECTANGULAR ELBOW (UP). E/A LONG 90° RECTANGULAR ELBOW (DOWN). DUCT CONTINUATION. W SAN AV AW ST RHG NPW IW RL FOR FOD FOS VPD VAC BGR V BBD SAN G ST CW DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER RETURNHWR HW STEAM RETURN PUMPED DISCHARGE HIGH PRESSURE STEAM MEDIUM PRESSURE STEAM LOW PRESSURE STEAM HEATING HOT WATER SUPPLY FUEL OIL GAGE LINE FUEL OIL FILL FUEL OIL VENT LINE REFRIGERANT SUCTION LINE HEATING HOT WATER RETURN RS STMR PD HPS MPS LPS HWR HWS FOG FOF FOV FUEL OIL RETURN FUEL OIL DISCHARGE FUEL OIL SUPPLY VACUUM PUMP DISCHARGE VACUUM SERVICE BOILER GRAVITY RETURN BOILER BLOW DOWN VENT REFRIGERANT LIQUID LINE INDIRECT WASTE SANITARY SOIL ABOVE GRADE STORM SEWER ABOVE GRADE STORM SEWER BELOW GRADE GAS ACID WASTE ACID VENT REFRIGERANT HOT GAS LINE NON-POTABLE WATER SANITARY SOIL BELOW GRADE WASTE DOMESTIC COLD WATER SUPPLY LINE TYPES A COMPRESSE D AIR CONDENSER WATER RETURN FROM FLUID COOLER CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSER WATER SUPPLY TO FLUID COOLERCTS CTR CHS CHR CONDENSATE DRAINCD DUAL TEMPERATURE RETURN DUAL TEMPERATURE SUPPLYDTS DTR GW GREASE WASTE TG TO GEOTHERMAL WELL FIELD FG FROM GEOTHERMAL WELL FIELD MECHANICAL SYMBOLS AND ABBREVIATIONS NEW WORK PLAN NOTE WATER HAMMER DESIGNATION VALVE DESIGNATION EXISTING TO REMAIN DESIGNATION POINT OF NEW CONNECTION ALTERNATE TAG DETAIL TITLE DESIGNATION EQUIPMENT TAG DETAIL NOTE DESIGNATION DEMOLITION PLAN NOTE TRAP STYLE: T = THERMOSTATIC F = FLOAT FT = FLOAT/THERMOSTATIC E = FURNISHED WITH EQUIPMENT STEAM PRESSURE PSIG PRESSURE DISCHARGE PSIG SAFTY FACTOR RUNNING LOAD, LBS/HR APPLY RECOMMENDED STEAM TRAP DESIGNATION (USE WHEN IDENTIFYING BIDDING ALTERNATES) POINT OF DISCONNECTION (SHADED PORTION INDICATES EXISTING TO REMAIN) NOTE SYMBOLS SHEET TITLESCALE: 1 /8" = 1 '-0"PLAN TITLE DESIGNATION #REVISION TRIANGLE NORTH ARROW SHEET TITLESCALE: 1 /8" = 1 '-0" XX MXXX XX MXXX 1 . THESE GENERAL NOTES APPLY TO M-SERIES DRAWINGS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE NOTED ON THOSE SHEETS. 2. ON MECHANICAL "M" SERIES DRAWINGS, DARK LINE ITEMS INDICATE NEW WORK. LIGHT LINE ITEMS ARE FUTURE WORK. 3. THESE DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION FOR PIPING, DUCTWORK, CONDUIT, ETC.. THE EQUIPMENT SHOWN ILLUSTRATES SUGGESTED ROUTING, BUT ALL NECESSARY OFFSETS MAY NOT BE SHOWN. DIVISION 23 SHALL INSTALL HIS WORK IN A MANNER THAT WILL CONFORM WITH THE STRUCTURE. DIVISION 23 SHALL AVOID OBSTRUCTIONS, PRESERVE HEADROOM AND MAINTAIN MAXIMUM CLEARANCE WITHOUT FURTHER INSTRUCTION FROM THE ARCHITECT/ENGINEER OR ADDITIONAL COST TO THE OWNER. 4. ALL DUCTWORK, PIPING, AND VALVES SHALL BE CONCEALED ABOVE CEILING AND WITHIN WALLS IN FINISHED AREAS UNLESS OTHERWISE INDICATED. 5. ALL VALVES, ETC. SHALL BE INSTALLED ALLOWING EASY ACCESS BETWEEN LIGHT FIXTURES AND NO HIGHER THAN 1 2" TO 24" ABOVE THE CEILING. PROVIDE FITTINGS IN DUCTWORK AND PIPING AS REQUIRED SO THAT NO PIPING REMAINS TIGHT TO ROOF STRUCTURE. PROVIDE ACCESS PANELS AS REQUIRED. AREA ADJACENT TO THE ACCESS PANELS SHALL BE CLEAR OF ANY OBSTRUCTIONS. PROVIDE EXTENDED VALVE HANDLES FOR INSULATED PIPING. 6. DIVISION 23 SHALL BE GUIDED BY THE ARCHITECT/ENGINEER'S REFLECTED CEILING PLAN FOR LOCATION OF DIFFUSERS, REGISTERS, GRILLES SHOWN OR COVERED BY THESE PLANS. 7. PIPING BRANCHES TO EQUIPMENT SHALL HAVE SAME SIZE VALVES AND FITTINGS AS THAT OF THE LINE SIZE. UNLESS NOTED OTHERWISE. 8. DUCT AND PIPING PENETRATING FLOOR SLABS AND/OR WALLS SHALL BE SEALED WITH ACOUSTIC SEALANT. IF THE FLOOR OR WALL IS FIRE RATED PROVIDE THE FIRE STOPPING OR FIRE DAMPER TO MAINTAIN THE FIRE RATING. 9. ALL RECTANGULAR SHEET METAL DUCT SIZES ARE INSIDE DIMENSIONS. ALL ROUND DUCT SIZES SHOWN ARE INSIDE DIAMETERS. ALLOWANCE FOR ACOUSTICAL LINER WHERE INDICATED ON DRAWINGS MUST BE ADDED TO OBTAIN OUTSIDE SHEET METAL DIMENSION. 1 0. ALL WALL THERMOSTATS, TEMPERATURE SENSORS, AND/OR HUMIDISTATS SHALL BE APPROXIMATELY 48" ABOVE FINISHED FLOOR TO CENTER AND LINED UP HORIZONTALLY WITH LIGHT SWITCHES UNLESS OTHERWISE NOTED OR DIRECTED BY THE ARCHITECT/ENGINEER. 1 1 . DIVISION 23 CONTRACTOR SHALL BE RESPONSIBLE FOR HIS RESPECTIVE WORK FOR REPAIRING AND PATCHING TO MATCH EXISTING SURFACES, SIDEWALKS, STREETS, FLOORS, WALLS, ROOFS, CEILING AND PAVEMENT. CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS FOR CUTTING AND PATCHING REQUIRED TO INSTALL NEW OR REMOVE EXISTING WORK, EQUIPMENT, OR SYSTEMS. 1 2. DIVISION 23 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL OF HIS WORK TO BE INSTALLED WITH ANY AND ALL OTHER CONTRACTORS TO BE AFFECTED BY SUCH WORK, PRIOR TO ORDERING ANY OF THE EQUIPMENT. THIS SHALL INCLUDE BUT NOT LIMITED TO ELECTRICAL CHARACTERISTICS, CONNECTIONS REQUIRED, PHYSICAL SIZE, COLOR AND FIT. ALSO REFER TO SPECIFICATIONS. 1 3. ALL EQUIPMENT SHALL BE OF, AND CONSIST OF, AT LEAST MINIMUM SIZES SELECTED, AND SHALL PERFORM TO OR SURPASS THE MINIMUM REQUIREMENTS, SCHEDULES, NOTED AND SPECIFIED. 1 4. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL GRILLES, REGISTERS AND DIFFUSERS IN CEILINGS WITH THE CEILING SYSTEM AND LIGHT FIXTURES. PROVIDE FLEXIBLE DUCT UPSTREAM OF EACH DIFFUSER WHERE SHOWN. 1 5. PROVIDE VOLUME DAMPERS IN ALL BRANCH DUCTWORK AS REQUIRED TO BALANCE EACH SYSTEM. ALL VOLUME DAMPERS LOCATED ABOVE DRYWALL CEILINGS SHALL BE CABLE OPERATED WITH REMOTE REGULATOR LIKE YOUNG REGULATOR. FIELD VERIFY EXISTING CEILINGS FOR DRYWALL CEILINGS. COORDINATE LOCATION OF ALL DAMPERS WITH AIR BALANCE CONTRACTOR. IN HARD CEILINGS PROVIDE VOLUME DAMPER BEHIND THE GRILLE, REGISTER, OR DIFFUSER. 1 6. ALL NEW PIPING AND DUCTWORK CROSSING THRU CORRIDOR AND/OR ROOM WALLS TO DECK; COORDINATE ALL OPENINGS THROUGH WALL CONSTRUCTION WITH GENERAL TRADES. SEAL AROUND DUCTWORK AND PIPING TO HELP REDUCE THE TRANSFER OF NOISE BETWEEN ROOMS. 1 7. ROUND DUCT SIZE TO BE THE SAME SIZE AS THE DIFFUSER NECK; UNLESS OTHERWISE NOTED. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK CONNECTED TO A DIFFUSER SHALL BE 6'-0". 1 8. ALL DUCTWORK CONSTRUCTION SHALL BE FABRICATED SHEET METAL & BUILT IN ACCORDANCE WITH "SMACNA" STANDARDS. 1 9. ALL TRANSFER AIR DUCTS TO BE INTERNALLY INSULATED TO DETER NOISE TRANSFER. SIZE SHOWN ON PLANS INDICATES ACTUAL FREE AREA. 20. ALL HARD 90° ELBOWS IN SUPPLY DUCTWORK ARE TO HAVE TURNING VANES PER SPECIFICATION AIR DUCT ACCESSORIES. 21 . ALL EXHAUST FANS, RELIEF VENTS, AND PLUMBING VENTS TO BE INSTALLED A MINIMUM OF 1 0 FT. FROM OUTDOOR AIR INTAKES. 22. ALL ROOF PENETRATIONS TO BE SEALED WATER TIGHT. PACK VOID BETWEEN DUCT PENETRATING ROOF AND STRUCTURE WITH FIBERGLASS INSULATION AND CAULK WATER TIGHT. FOR HIGH TEMPERATURE OR GREASE DUCTS UTILIZE MINERAL WOOL. 23. CONTRACTOR SHALL CLEAN ALL OF HIS WORK INSIDE AND OUT. AIR DISTRIBUTION SYSTEMS SHALL HAVE ALL DIRT AND FOREIGN MATERIAL REMOVED FROM INSIDE AND OUTSIDE OF DUCTS, PLENUMS, HOUSINGS, DEVICES, TERMINALS, ETC. AS INSTALLATION PROGRESSES, PROTECT OPEN ENDS OF DUCTWORK AND INLETS AND OUTLETS OF EQUIPMENT AND DEVICES DURING CONSTRUCTION. CLEAN ALL ACCESSIBLE PARTS OF DUCTWORK AND AIR PASSAGES IN EQUIPMENT BEFORE FILTERS ARE INSTALLED OR REPLACED FOR SYSTEM BALANCING. 24. FURNISH AND INSTALL ACCEPTABLE CONCRETE INSERTS, ANCHORS, CLAMPS, BRACKETS, HANGERS, STRUCTURAL MEMBERS (ANGLES, CHANNELS, ETC.) AND FRAMES, ETC., REQUIRED FOR SUPPORTING ALL RESPECTIVE WORK. SUPPORTING DEVICES, ASSEMBLIES AND ATTATCHMENTS SHALL BE DESIGNED AND ARRANGED TO CARRY THE WEIGHT OF THE SUPPORTED ITEMS INCLUDING HANGER AND CONTENTS WITHOUT TRANSMITTING VIBRATION OR NOISE TO THE BUILDING CONSTRUCTION; DESIGNED, APPROPRIATE AND APPROVED FOR THE PURPOSE USED; HAVE A NEAT AND FINISHED APPEARANCE AND COMPLEMENT THE INSTALLATION; HAVE CORROSION PROTECTION SUITABLE FOR THE ATMOSPHERE WHERE INSTALLED; ADEQUATELY AND SAFELY ATTACHED TO THE BUILDING STRUCTURE OR STRUCTURAL MEMBERS. EXPOSED SUPPORTS SHALL BE PAINTED UNLESS OF NON-FERROUS MATERIAL OR PROVIDED WITH PLATED (RUSTPROOF) FINISH. 25. PROVIDE NEC CLEARANCES AND SERVICE CLEARANCES FOR EQUIPMENT. 26. COORDINATE EQUIPMENT SERVICE ACCESS. CLEARANCES INDICATED ARE BASED UPON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY PIPING, DUCTWORK, ETC., ROUTING PRIOR TO SUBMITTING A BID PROPOSAL AND INCLUDE ANY SUCH COSTS AS REQUIRED TO INSTALL WORK AS SHOWN AND INTENDED. ELEVATOR EQUIPMENT ROOMS: DO NOT ROUTE ANY SYSTEMS THROUGH ELEVATOR EQUIPMENT ROOMS. FOR SYSTEMS THAT SERVE ELEVATOR EQUIPMENT ROOMS, DO NOT ROUTE OVER ELEVATOR EQUIPMENT OR ELECTRICAL COMPONENTS AND DO NOT HINDER SERVICE ACCESS. TELECOMMUNICATIONS ROOMS (MDF AND IDF): DO NOT ROUTE ANY SYSTEMS THROUGH TELECOMMUNICATIONS ROOMS. FOR SYSTEMS THAT SERVE T-COMM ROOMS, DO NOT ROUTE OVER EQUIPMENT OR ELECTRICAL COMPONENTS AND DO NOT HINDER SERVICE ACCESS. ELECTRICAL EQUIPMENT ROOMS: DO NOT ROUTE ANY SYSTEMS THROUGH ELECTRIC ROOMS. FOR SYSTEMS THAT SERVE ELECTRIC ROOMS, DO NOT ROUTE OVER EQUIPMENT, PANELS, TRANSFORMERS, VFD'S, OR ELECTRICAL COMPONENTS AND DO NOT HINDER SERVICE ACCESS. 27. DURING REMOVAL OF ITEMS SO INDICATED, CAUTION SHALL BE USED TO PREVENT DAMAGE TO ANY EQUIPMENT HAVING SALVAGE VALUE. ALL REUSABLE SALVAGED MATERIAL SHALL REMAIN THE PROPERTY OF THE OWNER AND BE RETAINED FOR HIS INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY THE OWNER SHALL BE DISPOSED OF BY THE CONTRACTOR. ALL OTHER ITEMS SHALL BE TURNED OVER AND DEPOSITED AS DIRECTED BY THE OWNER. 28. ACCESS TO FIRE/SMOKE DAMPERS MUST BE PROVIDED WHETHER SHOWN ON PLAN OR NOT. ACCESS MUST KNOW EASY SERVICE OR FUSIBLE LINK OR ANCHOR FOR RESET AND BE CLEARLY MARKED. AUTOMATIC FLOW LIMITING VALVE AUTOMATIC AIR VENT MANUAL AIR VENT MANUAL BALANCE VALVE 2-WAY GEAR DRIVE VALVE 2-WAY MOTORIZED VALVE 3-WAY BLINDER VALVE (PLUMBING) 3-WAY MOTORIZED VALVE (MECHANICAL) BALL VALVE BACK FLOW PREVENTER BUTTERFLY VALVE PNEUMATIC MODULATING BUTTERFLY VALVE PRESSURE INDEPENDENT CONTROL VALVE HOSE BIBB / WALL HYDRANT PRESSURE REGULATING VALVE W/ FLOW DIRECTION SPRING LOAD CHECK VALVE CHECK VALVE GAS COCK PIPE ANCHOR STRAINER PIPING TEE DOWN FLOOR DRAIN PITOT DEVICE UNION FLEX CONNECTION EXPANSION JOINT PIPE GUIDE PT PORT PIPE CAP PIPING TURN DOWN PIPING TURN UP PRESSURE RELIEF VALVE MOTORIZED BUTTERFLY VALVE TOTAL DISOLVED SOLIDS SENSOR. PRESSURE TRANSDUCER WITH SHUT-OFF COCK. BALANCE PLUG VALVE GATE VALVE GLOBE VALVE DOMESTIC HWR FLOW STATION VALVE IN RISER GAS PRESSURE REGULATING VALVE 2-WAY VALVE (PNEUMATIC) STRAINER WITH BLOW DOWN SOLENOID VALVE SLOPE ARROW DIFFERENTIAL PRESSURE SWITCH FLOW TRANSMITTER W/ FULL PORTED BALL VALVE FOR EXTRACTION PRESSURE GAGE, WITH PIGTAIL AND SHUTOFF COCK PRESSURE GAGE, WITH SNUBBER AND SHUTOFF COCK PRESSURE GAGE, WITH SHUTOFF COCK THERMOSTATIC MIXING VALVE FLOW SWITCH STRAP-ON/OUTSIDE AIR TEMPERATURE SENSOR LEVEL SWITCH LEVEL CONTROLLER VALVE IN ROAD BOX FLOW METER FLOAT SWITCH VACUUM BREAKER PRESSURE SWITCH DIFFERENTIAL PRESSURE TRANSMITTER PIPING REDUCER LINE CLEAN OUT PH SENSOR FLANGE END OF MAIN C.O. FLOOR CLEANOUT WATER/GAS METER 3-WAY BY-PASS VALVE (PLUMBING) SOLAR POWERED TEMPERATURE GAUGE W/ THERMO-WELL TEMPERATURE TRANSMITTER W/ THERMO-WELL PIPING SYMBOLSMECHANICAL GENERAL NOTES DUCT INSULATION NOTES: ALL EXHAUST AIR DUCTWORK FROM THE BOTTOM OF THE ROOF CURB TO THE EXHAUST FAN BACK DRAFT DAMPER SHALL BE EXTERNALLY INSULATED. ALL OTHER EXHAUST AIR DUCTWORK SHALL NOT BE INSULATED. 3. 1 . 2. ALL CONCEALED SUPPLY AND RETURN DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH 1 .5" FIBERGLASS INSULATION, EXCEPT WHERE NOTED OTHERWISE ON PLANS. ALL CONDENSATE PIPING SHALL EB INSULATED WITH 1_2" FLEXIBLE ELASTOMERIC INSULATION. ALL EXPOSED SUPPLY AND RETURN DUCTWORK SHALL NOT BE INSULATED EXCEPT WHERE NOTED OTHERWISE ON PLANS. ALL REFRIGERANT PIPING INDOORS SHALL BE INSULATED WITH 1_2" FLEXIBLE ELASTOMERIC INSULATION. 4. ALL REFRIGERANT PIPING OUTDOORS SHALL BE INSULATED WITH 1 " FLEXIBLE ELASTOMERIC INSULATION AND PVC JACKET. 5. 6. EXTERIOR SUPPLY AND RETURN SPIRAL DUCT SHALL BE INSULATED WITH 2" MINERAL FIBER BLANKET SIMILAR TO JOHNS MANVILLE MICROFLEX, MIN. R-6 WITH VAPOR BARRIER AND VENTURECLAD 1 577CW. WHITE STUCCO EMBOSSED FINISH. 7. EXTERIOR SUPPLY AND RETURN RECTANGULAR DUCT SHALL BE INSULATED WITH 2" MINERAL FIBER BOARD WITH STAGGERED JOINTS, MIN. R-6 WITH VAPOR BARRIER AND VENTURECLAD 1 577CW. WHITE STUCCO EMBOSSED FINISH. 8. ALL AIR HANDLING OR ROOFTOP UNITS LARGER THAN 25 TONS SHALL HAVE THE FIRST 20' OF THEIR SUPPLY DUCT AS 1 " DOUBLE WALL WITH SMOOTH INNER WALL OR PERFORATED INNER LINER. 8. RD PE1 1 400027 NENOISS AL EFORP D STATE OF NI IA N A ERG IN E SIGE TERE No.CAMERON T .YAMA SHITASHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 1/13/2022 10:54:03 AMM-001 SYMBOLS AND ABBREVIATIONS 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 SHEET INDEX SHEET NO.SHEET TITLE CURRENT REVISION DATE CURRENT REVISION DESCRIPTION M-001 SYMBOLS AND ABBREVIATIONS 01/13/22 BULLETIN SET M-101 OVERALL FIRST FLOOR MECHANICAL PLAN 12/17/21 CD SET M-101A FIRST FLOOR MECHANICAL PLAN - AREA A 12/17/21 CD SET M-101B FIRST FLOOR MECHANICAL PLAN - AREA B 12/17/21 CD SET M-101C CATWALK MECHANICAL PLAN - AREA A 12/17/21 CD SET M-102 OVERALL SECOND FLOOR MECHANICAL PLAN 12/17/21 CD SET M-102A SECOND FLOOR MECHANICAL PLAN - AREA A 12/17/21 CD SET M-102B SECOND FLOOR MECHANICAL PLAN - AREA B 12/17/21 CD SET M-103 OVERALL THIRD FLOOR MECHANICAL PLAN 01/13/22 BULLETIN SET M-103A THIRD FLOOR MECHANICAL PLAN - AREA A 01/13/22 BULLETIN SET M-103B THIRD FLOOR MECHANICAL PLAN - AREA B 12/17/21 CD SET M-201 OVERALL FIRST FLOOR MECHANICAL PIPING PLAN 12/17/21 CD SET M-202 OVERALL SECOND FLOOR MECHANICAL PIPING PLAN 12/17/21 CD SET M-203 OVERALL THIRD FLOOR MECHANICAL PIPING PLAN 01/13/22 BULLETIN SET M-204 OVERALL HIGH ROOF MECHANICAL PIPING PLAN 01/13/22 BULLETIN SET M-300 MECHANICAL SECTIONS 12/17/21 CD SET M-301 MECHANICAL SECTIONS 12/17/21 CD SET M-500 MECHANICAL DETAILS 12/17/21 CD SET M-600 MECHANICAL ISOMETRICS 12/17/21 CD SET M-700 MECHANICAL SCHEDULES 01/13/22 BULLETIN SET SHOP DRAWINGS M-101A-2-SD FIRST FLOOR SHEET METAL - AREA A.2 - DEEM SD M-101A-3-SD FIRST FLOOR SHEET METAL - AREA A.3 - DEEM SD M-101A-4-SD FIRST FLOOR SHEET METAL - AREA A.4 - DEEM SD M-101B-1-SD FIRST FLOOR SHEET METAL - AREA B.1 - DEEM SD M-101B-2-SD FIRST FLOOR SHEET METAL - AREA B.2 - DEEM SD M-101B-3-SD FIRST FLOOR SHEET METAL - AREA B.3 - DEEM SD M-101B-4-SD FIRST FLOOR SHEET METAL - AREA B.4 - DEEM SD SHOP DRAWINGS M-101A-1-SD FIRST FLOOR SHEET METAL - AREA A.1 - DEEM SD 1 PERMIT SET 11/30/21 2 CD SET 12/17/21 3 BULLETIN SET 01/13/22 01/13/22 02/23/22