Loading...
HomeMy WebLinkAboutM-101B-FIRST-FLOOR-MECHANICAL-PLAN---AREA-B-Rev.61 3 4 5 6 7 8 D E H J 7.7 D.8 D.3 3.2 2 2.2 2.4 3.8 4.1 5.4 5.6 6.4 6.6 7.4 7.6 7.82.6 2.8 3.3 4.8 5.2 5.8 6.2 6.8 7.2 2.1 1.9 VESTIBULE 100 WOMEN 121 MEN 120ADA 119 UNISEX 122 JAN 123 ENTRY STAIR 101 CABIN TRAINER SUPPORT SPACES 102 RAMP 105 100 PERSON AUDITORIUM 106 COMMUNITY CENTER LAB 107A NORTH CORRIDOR 110 LOUNGE 114 SOUTH CORRIDOR 104 MAINTENANCE LARGE EQUIPMENT TRAINING 111 MAINTENANCE 32 STUDENT 112 MAINTENANCE 30 STUDENT 113 ACCESS CORRIDOR 115 DELIVERY 116 TRASH 117 60 PERSON CLASSROOM 118 56" 56"56" 26" 16" 42"WATER SERVICE 117A LOCKED CABIN TRAINER STG 107B WAITING 107 VAV-1-13 VAV-1-12 VAV-1-11 VAV-1-18 VAV-1-17 VAV-1-15 VAV-1-16 VAV-1-4 VAV-1-3 VAV-1-2 VAV-1-1 VAV-1-5 VAV-1-6 VAV-1-7 VAV-1-19 VAV-1-8 VAV-1-9 VAV-1-1436"38"36"32"30"28"26" 26" 26" 12"VAV-1-10 18"26"18"18" 14"28"10"14"14"14" 16" 18" 14" 10" 14"SD10 225 SD10 225 SD10 225 SD10 225 12"SD10 300 SD10 300 SD10 300 SD10 300 16"SD10 300 SD10 300 SD10 300SD10 300SD12 400 SD14 760 SD14 760 SD14 760 22"18" 22" 18" 44"x20"44"x20"44"x20"44"x20"44"x20"6"x6"6"x6"12"x12"10"x8" 12"x12"12"x12" EG12 50 EG12 50 EG22 300 EG22 250 10"x8"EG12 50 SDG1 250 SDG1 300 SDG1 250 SD8 250 T VAV-1-19 3 20" TYP. OF 6 16" 20" 12" 12"10" T VAV-1-8 T VAV-1-9 3 38"10"12"10"T VAV-1-10 35 5 5 5 SD10 275 SD10 225 18"18"14" 12" 10"10"10" 10" 10"10"SD10 333 TYP. OF 6 T VAV-1-14 3 4 5 R2218"18" 12"10"10"18" 22" LSD1 255 TYP. OF 7 18" 10" 10" SDG1 300 TYP. OF 6 18"28"28"10"12"10"14"10"10"16"16"18"10" SD10 267 TYP. OF 6 12"10"10" SD10 300 SD10 300 26"26"42"22"20"18"16"16"T 3 VAV-1-13 14"16" 18" 20"16" 22" SDG2 375 TYP. OF 8 T VAV-1-12 3 2 14"14"14" 18" 16"18" 16" TYP. OF 8SDG2 375 SDG2 320 TYP. OF 5 T VAV-1-11 312"10" 10" 10" 10" 10"12"10"10" 10"10"16"8"16" 16" 16" 10"10" 10" 10" 18" 22" 20"18"14" 10" 12" 12" 12" 12" 22"18"14" 14" 14" 14"14"14"14"14" 14" 14" 14" 14"18"10"TYP. OF 5 TYP. OF 4 TYP. OF 4 TYP. OF 4 TYP. OF 4 1 T 3VAV-1-1 T 3 VAV-1-4 T VAV-1-3 3 T VAV-1-2 3 T VAV-1-5 3 T VAV-1-6 3 T VAV-1-7 3 T VAV-1-18 3 R22 R22 4 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 R22 RG1 R12 10"1 M-300 SG1 290 12"x6"12"x6"12"x6"12"x6" 12"x6" 16" 12"10"10"10"10"10"10"10"10"10"10" 16"10"10"10"LSD1 305 TYP. OF 2 SD10 365 SD10 365 TYP. OF 3 LSD1 305 TYP. OF 210"10"R22 R22 TVAV-1-17 RG1 TYP. OF 2 1 M-301 7 M-500 (TYP) 7 M-500 (TYP) 5 M-500 5 M-500 (TYP) 7 M-500 (TYP) 5 M-500 (TYP)5 M-500(TYP) 5 M-500(TYP) 7 M-500 (TYP) 7 M-500(TYP) 5 M-500(TYP) 5 M-500 (TYP) 7 16" 20" 20" 5 M-500(TYP) 66 66 6 RG2RG2RG2 RG2 SG1 365 SG1 365 SG1 365 FD 8 22" 16" GENERAL NOTES: • REFER TO M-001 FOR ADDITIONAL GENERAL NOTES. • ALL EXPOSED DUCT TO BE PAINT GRIP FINISH. • ALL VAV BOXES MUST BE INSTALLED WITHIN 3'-0" ABOVE CEILING FOR MAINTENANCE. • REFER TO M-001 FOR INSULATION NOTES. • REFER TO PLUMBING PLANS FOR CONDENSATE PIPING.RD PE11400027 NENOISS AL EFORP D STATE OF NI IA N A ERG IN E SIGE TERE No.CAMERON T .YAMA SHITASHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 12/17/2021 1:31:48 PMM-101B FIRST FLOOR MECHANICAL PLAN - AREA B 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/8" = 1'-0"M-101B 1 FIRST FLOOR MECHANICAL PLAN -AREA B PLAN NOTES: 1 54" ROUND SUPPLY DUCT FROM RTU-1 ON ROOF THROUGH CHASE TO 1ST FLOOR. PROVIDE FIRE DAMPER AND ACCESS WHERE EXITING SHAFT WALL. REFER TO INSULATION SCHEDULE ON M001 - FIRST 20' OF SUPPLYDUCT SHALL BE 1" DOUBLE WALL INSULATED. 2 56" ROUND RETURN DUCT FROM RTU-1 ON ROOF THROUGH CHASE TO 1ST FLOOR. PROVIDE FIRE DAMPER AND ACCESS WHERE EXITING SHAFT WALL. 3 MOUNT THERMOSTAT AT 48" A.F.F. 4 RETURN GRILLE TO BE INSTALLED IN CEILING WITH LAY-IN BORDER FOR EASY REMOVAL FOR ACCESS TO VAV BOX FOR MAINTENANCE. 5 UNDERCUT DOOR 1" TO ALLOW AIRFLOW FROM ADJACENT SPACE. 6 COVER RETURN PENETRATION WITH HEAVY DUTY WIRE MESH. 7 16" SUPPLY AND 20" RETURN AIR DUCT DOWN FROM RTU-5 FOR CABIN TRAINER. 22" ROUND SMOKE EVACUATION DUCT UP TO EF-2 ON ROOF. 8 INSTALL FIRE DAMPER WHERE DUCT PENETRATES FLOOR SLAB. 1 PERMIT SET 11/30/21 2 CD SET 12/17/21 12/17/21 02/23/22