Loading...
HomeMy WebLinkAboutP-101B-FIRST-FLOOR-PLUMBING-PLAN---AREA-B-Rev.8MMP-400 1 1 2 3 (11,791 SQ.FT.) (8,735 SQ.FT.) 4"FCO 4"FD-2 4"FD-2 4"FD-2 4"FCO 8"ST FCO MAINTENANCE 32 STUDENT 112 MAINTENANCE LARGE EQUIPMENT TRAINING 111 100 PERSON AUDITORIUM 106 MAINTENANCE 30 STUDENT 113 ACCESS CORRIDOR 115 DELIVERY 116 TRASH 117 WATER SERVICE 117A 60 PERSON CLASSROOM 118 LOUNGE 114 COMMUNITY CENTER LAB 107A LOCKED CABIN TRAINER STG 107B SOUTH CORRIDOR 104 WOMEN 121 MEN 120 ADA 119 GENDER NEUTRAL 122 COMPUTER ROOM 126 SIM PARTS STORAGE 127 COMPUTER ROOM 128 STAIRS-02 S-002 FUTURE COMPUTER ROOM 125 ENTRY STAIR 101 CABIN TRAINER SUPPORT SPACES 102 ? ? NORTH CORRIDOR 110 5 6 (17,201 SQ.FT.) 1 2 8" ST 1" HW 1" HWR 1" HW 2"FD-12"FD-12"FD-1 FCO 8765421 H D E F G 3 I 3" CW FCO P-101B 2 FCOBAO -1 AF-1 BAO -1 BAO -1 BAO -1 4"FD-2 BAO -1 1/2" BA 1/2" BA 1/2" BA1/2" BA 1/2" BA 1/2" BA 8"ST FCO GCO GCO 3/4" CW (HVAC MAKEUP)(HVAC MAKEUP) 7 7 8 9 (HVAC MAKEUP) (HVAC MAKEUP) 9 4" G 4" G (2 PSI) (2 PSI) (2 PSI) (2 PSI) 4" G 4" V 4" V 4" V 4" V1" CW1" CW 1" CW 1" CW1" CW1" G 1" G 1" G 1" G 1" G (2 PSI) (2 PSI)(2 PSI) (2 PSI) (2 PSI) WH-1 3/4" CW 3/4" CW 3/4" CW 3/4" CW (HVAC MAKEUP)11 1 3 4 5 6 7 8 D E F G H J 7.7 D.8 D.3 3.2 C.7 2 2.4 4.1 6.6 7.4 7.6 7.8 C.8 2.6 2.8 3.3 4.8 5.2 5.8 6.2 6.8 7.2 2.1 1.9 5.6 FCO FCO AC-1 GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. 7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. 9. ALL PVC PIPING IN OPEN AIR PLENUMS SHALL BE INSULATED AND WRAPPED TO MEET 25/50 FLAME SMOKE RATING REQUIREMENT. 8 H I 1" HW 1" HWR 3/4" HW 3/4" CW 4"FD-2 FCO DWH-1 TMV-1 RPZ-3 RPZ-2 RPZ-1 DWM -2 DWM -1 3"CW 1" CW 2" CW RCP-1 4 7 8 4"FD-2 ET-1 1" CW RPZ-4 (HVAC MAKEUP) (HVAC MAKEUP) 10 8 H J 7.7 1" CW 1" CW 1" HWR 1" HW 4" G 1" CW RD PE11400027 NENOISSAL EFORP D STATE OF NI IA N A ERGIN E SIGE T ERE No.CAMERON T .YAMA SHITASHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 1/13/2022 3:08:46 PMP-101B FIRST FLOOR PLUMBING PLAN - AREA B Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/8" = 1'-0"P-101B 1 FIRST FLOOR PLUMBING PLAN B # PLAN NOTES 1 8" STORM FROM ABOVE 2 8" STORM DOWN TO BELOW SLAB 3 SEE ENLARGED PLAN FOR WORK IN THIS AREA (P-400) 4 4" VENT UP FROM BELOW SLAB 5 10" STORM FROM ABOVE. 6 10" STORM DOWN IN VOID SPACE TO BELOW SLAB. 7 3" DOMESTIC COLD WATER SERVICE UP FROM BELOW SLAB 8 1" IRRIGATION UP FROM BELOW SLAB 9 4" GAS MAIN UP. 10 PROPOSED GAS METER LOCATION. GAS METER CAPABLE OF 4,357,320 BTU/HR. 11 3/4" COLD WATER UP TO FLOOR ABOVE. 1/4" = 1'-0"P-101B 2 ENLARGED WATER SERVICE ROOM PLUMBING PLAN 2 PERMIT SET 11/30/21 3 CD SET 12/17/21 4 BULLETIN SET 01/13/22 01/13/22 4 4 02/23/22