Loading...
HomeMy WebLinkAboutP-103B-THIRD-FLOOR-PLUMBING-PLAN---AREA-B-Rev.7DN STORAGE 316 P-400 3 4,205 S.F. 5,371 S.F. 3,362 SQ.FT. 3,358 SQ.FT. 741 SQ.FT. 4"RD-1 4"ORD-1 4"RD-1 4"ORD-2 1 6"RD-1 6"ORD-1 1 2 MEN 319 ADA 317 LOUNGE 315 WOMEN 320 GENDER NEUTRAL 321 STAIR 301 CONFERENCE 300 OPEN OFFICE -78 DESKS 304 TELECOM 303 EVPT 305 DEBRIEF 305A IN-FLIGHT NEW HIRE 30 STUDENTS 313 IN-FLIGHT NEW HIRE 30 STUDENTS 314 LOUNGE 315 4"RD-1 4"ORD-1 3,083 SQ.FT. 1,775 SQ.FT. 4"RD-2 4"ORD-2 4"RD-2 4"ORD-2 6"RD-1 6"ORD-1 8,433 SQ.FT. 14,127 SQ.FT. 87 6 5 4 2 1 H D E F G 3 I 2,794 S.F. +5,371 S.F. HIGH ROOF + 268 S.F. WALL 3 3" G 3" G 2" G 3/4" G 2" G 4" G (2 PSI) (2 PSI) (2 PSI) 4 5 (2 PSI) 7 6 1,000 SQ.FT. 4"RD-2 4"ORD-2 900 SQ.FT. 4"RD-24"ORD-2 1,775 SQ.FT. 4"RD-2 4"ORD-2 1,100 SQ.FT. 4"RD-2 4"ORD-2 8 9 GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. 7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. 9. ALL PVC PIPING IN OPEN AIR PLENUMS SHALL BE INSULATED AND WRAPPED TO MEET 25/50 FLAME SMOKE RATING REQUIREMENT.RD PE11400027 NENOISSAL EFORP D STATE OF NI IA N A ERGIN E SIGE T ERE No.CAMERON T .YAMA SHITASHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 12/17/2021 1:45:51 PMP-103B THIRD FLOOR PLUMBING PLAN - AREA B Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/8" = 1'-0"P-103B 1 THIRD FLOOR PLUMBING PLAN B # PLAN NOTES 1 DOWNSPOUT FROM HIGH ROOF BY OTHERS 2 SEE ENLARGED PLAN FOR WORK IN THIS AREA (P-400) 3 GAS PRESSURE REGULATOR FROM 2 PSI TO 14" W.C. GAS PRESSURE REGULATOR CAPABLE OF 31,320 BTU/HR 4 EXTEND AND FINAL CONNECT 3/4" GAS TO MECHANICAL EQUIPMENT. PROVIDE GAS COCK AND DRIT LEG. 5 GAS PRESSURE REGULATOR FROM 2 PSI TO 14" W.C. GAS PRESSURE REGULATOR CAPABLE OF 1,143,000 BTU/HR 6 EXTEND AND FINAL CONNECT 1 1/2" GAS TO MECHANICAL EQUIPMENT. PROVIDE GAS COCK AND DRIT LEG. 7 4" GAS MAIN FROM BELOW. 8 NON FREEZE WALL HYDRANT. MOUNT AT +2'-0" ABOVE FINISHED ROOF. 9 3/4" COLD WATER FROM BELOW. 2 PERMIT SET 11/30/21 3 CD SET 12/17/21 12/17/21 02/23/22