HomeMy WebLinkAboutP-400-ENLARGED-PLUMBING-PLAN-Rev.812 3 4 4 2 1 2"FD-1 WC-1WC-1 WC-1 WC-1 WC-1H WC-1H WC-1H WC-1H U-1U-1 U-1H 2"FD-1 L-1L-1 L-1H L-1H L-1 L-1 1" HW 1/2" HW 1" HW 1" HW 1 1/2" CW 3" CW 2" CW 1" HW MSB-1 S-1 WC-1 L-1 L-1H WC-1H 2" CW 6 2" SAN 1/2" HW 7 7 7 2" V 2" V 1" HWR 1 2 1/2" CW1/2" CW 2" CW 1" HW 3" CW 1" HW 9 10 11 12 1 1/2" CW BF-1 14 15 16 1/2" CW 87 E 1" HW 22 23 30 30 27 29 34 29 29 29 29 33 2" V 2" V 4" V WH-1 3/4" CW 3/4" CW 7 8 E 7.7 D.8 7.4 7.6 7.86.8 7.2 4" V4" V 1 1 31 4 4 1 5 6 WC-1H WC-1HWC-1H WC-1H U-1U-1U-1H 2" SAN WC-1WC-1 WC-1WC-1 2" SAN 2"FD-1 2"FD-1 L-1 L-1 L-1H L-1H L-1 L-1 4" V1" HW 2" CW 4" V 2" CW 1 1/2" CW 1" HW 2" CW 1" HWR 1" HW S-1 BF-1 1" HW 1/2" HW 7 7 7 13 17 18 4" ST 4" ST 4" ST 26 10 29 14 15 16 WC-1 L-1 L-1H WC-1H 1 MSB-1 1/2" CW 1" HW 1" HW 1/2" HW 1" HW 3/4" CW 4" SAN 2" CW 4" V 4" V 1/2" HW 2" CW 87 E 22 23 13 254" ST28 29 29 29 29 11 2 32 33 7 8 E 7.7 D.8 7.4 7.6 7.87.2 1 1/2" CW 1" HW 1" HW WC-1H L-1H BF-1 L-1H L-1 U-1H U-1 WC-1H 2"FD-1 2"FD-1 WC-1HWC-1 WC-1 WC-1 L-1H L-1 L-1 S-1 WC-1 L-1 2" CW 2" CW 1" HW 1/2" CW 1" HW MSB-1 7 7 20 1" HW 1" HWR 1/2" HW 15 14 16 1/2" CW 2" CW 19 21 8 8 9 1" HW 1 1/2" CW 2" CW 2" V 7 E 22 23 24 8 8 11 31 5 28 2 333" V3" V2" V 4" V 4" V2" V2" V2" V 7 E 7.7 D.8 7.4 7.6 7.87.2 GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. 7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. 9. ALL PVC PIPING IN OPEN AIR PLENUMS SHALL BE INSULATED AND WRAPPED TO MEET 25/50 FLAME SMOKE RATING REQUIREMENT.RD PE11400027 NENOISSAL EFORP D STATE OF NI IA N A ERGIN E SIGE T ERE No.CAMERON T .YAMA SHITASHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 1/13/2022 3:08:48 PMP-400 ENLARGED PLUMBING PLAN Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/4" = 1'-0"P-400 1 ENLARGED FIRST FLOOR RESTROOM PLAN 1/4" = 1'-0"P-400 2 ENLARGED SECOND FLOOR RESTROOM PLAN 1/4" = 1'-0"P-400 3 ENLARGED THIRD FLOOR RESTROOM PLAN # PLAN NOTES 1 4" SANITARY STACK UP. 2 4" SANITARY STACK DOWN THROUGH SLAB. 3 4" VENT UP TO SECOND LEVEL. 4 2" SANITARY UP TO FLOOR DRAIN. 5 4" SANITARY STACK DOWN IN CHASE. 6 2" COLD WATER DOWN IN CHASE. ROUTE 2" HEADER THROUGH CHASE AND CONNECT 1" COLD WATER TO EACH OF (8) WATER CLOSETS, 3/4" COLD WATER TO EACH OF (3) URINALS AND 1/2" COLD WATER TO EACH OF (3) LAVATORIES. 7 1/2" HOT WATER DOWN IN WALL TO LAVATORY, 1/2" COLD WATER FROM CHASE. 2" SANITARY DOWN AND 2" VENT UP. 8 1/2" HOT AND COLD WATER DOWN IN WALL TO LAVATORY. 2" SANITARY DOWN, 2" VENT UP. 9 1/2" HOT AND COLD WATER DOWN IN WALL TO SINK. 2" SANITARY DOWN, 2" VENT UP. 10 1/2" HOT AND COLD WATER FROM CHASE TO MOP SINK. 3" SANITARY, 2" VENT UP. 11 1-1/2" COLD WATER DOWN IN CHASE. 1" COLD WATER TO WATER CLOSET. 4" SANITARY STACK FROM ABOVE AND DOWN, 2" VENT UP CHASE TO ABOVE CEILING. 12 1/2" HOT WATER DOWN IN CHASE. 13 4" STORM CONDUCTOR IN CHASE. 14 3" COLD WATER RISER IN CHASE. 1" HOT WATER RISER AND 1" HOT WATER RETURN RISER IN CHASE. 15 1/2" COLD WATER DOWN IN WALL TO BOTTLE FILLER. 2" SANITARY TO STACK, VENTED FROM TOP OF STACK. 16 2" COMBINATION SANITARY/ VENT STACK. 17 4" STORM UP TO ROOF DRAIN. 18 4" STORM UP TO OVERFLOW ROOF DRAIN. 19 4" VENT UP TO 4" V.T.R. 20 2" COLD WATER DOWN IN CHASE. ROUTE 2" HEADER THROUGH CHASE AND CONNECT 1" COLD WATER TO EACH OF (5) WATER CLOSETS, 3/4" COLD WATER TO EACH OF (2) URINALS AND 1/2" COLD WATER TO EACH OF (2) LAVATORIES. 21 4" SANITARY STACK DOWN. 22 1-1/2" TRAP ABOVE FLOOR FOR CONNECTION TO BOTTLE FILLER DRAIN TUBE 23 HOT WATER RETURN BALANCING STATION. BALANCE TO 2.0gpm 24 2" VENT FROM TOP OF COMBINATION STACK TO VENT ABOVE CLG. 25 SEE SECOND FLOOR PLUMBING PLAN FOR CONTINUATION. 26 1/2" HOT AND COLD WATER DOWN IN WALL TO SINK. 2" SANITARY FROM ABOVE AND DOWN. 27 2" SANITARY FROM ABOVE AND DOWN. 28 2" VENT FROM BELOW AND UP. 29 1/2" HOT AND COLD WATER DOWN, 2" WASTE FROM ABOVE AND DOWN. 30 4" STORM CONDUCTOR IN CHASE. PROVIDE BASE OR RISER CLEANOUT AT +18" ABOVE FINISHED FLOOR. 31 4" VENT FROM BELOW. 32 4" VENT UP TO THIRD LEVEL 33 PROVIDE WATER HAMMER ARRESTER PER SCHEDULE ON DRAWING P-600. COORDINATE ACCESS PANEL LOCATION WITH GENERAL TRADES. 34 2" VENT UP. 2 PERMIT SET 11/30/21 3 CD SET 12/17/21 4 BULLETIN SET 01/13/22 01/13/22 4 02/23/22