Loading...
HomeMy WebLinkAboutA-002-INTERIOR-PARTITIONTYPESANDSTANDARDPARTITIONDETAILSPARTITION TYPE SYMBOL PARTITION TYPE FIRE RATING (I.E. 1= 1 HOUR) PARTITION HEIGHT CODE NEW PARTITIONS EXISTING PARTITIONS TO REMAIN PARTITIONS TO BE DEMOLISHED M8A.D.2.A S2A.P ADDITIONAL PARTITION DESIGNATION, WHERE OCCURS PARTITION DESIGNATION ACOUSTICAL ATTENUATION REQ'D HEIGHT AS INDICATED IN INCHES OR (V) INDICATES HEIGHT THAT VARIES (C) TERMINATE AT CEILING (P) TERMINATE 6" ABOVE CEILING (D) TERMINATE AT FLOOR / ROOF DECK 6"REFER TO WALL SECTION FOR CONSTRUCTIONWS * FIRE RATING AND ACOUSTICAL ATTENUATION WHEN REQUIRED BY PARTITION SYMBOL 4 7/8"S3A 3 5/8" METAL STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE * 1 HR RATED UL419 * ACOUSTIC ATTEN. COMPONENTS STC-8 1/4"S6Y 6" METAL SHAFT WALL STUDS WITH (2) LAYERS 5/8" GYPSUM WALL BOARD ONE SIDE AND 5/8" GYP. BD LAYER AND 1" GYPSUM SHAFT LINER ON INSIDE FACE * 1 HR RATED U417 * ACOUSTIC ATTEN. COMPONENTS STC-60 M6A 5 5/8" CONCRETE MASONRY UNIT, RUNNING BOND * 2 HR RATED UL906 * ACOUSTIC ATTEN. COMPONENTS STC-46 5 5/8"M8A 7 5/8" CONCRETE MASONRY UNIT, RUNNING BOND 7 5/8"6 1/8"S3B 3 5/8" METAL STUDS WITH (2) LAYERS 5/8" TYPE X GYPSUM WALL BOARD EACH SIDE * 2 HR RATED U419 * ACOUSTIC ATTEN. COMPONENTS STC-50 7 1/4"S6A 6" METAL STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE * ACOUSTIC ATTEN. COMPONENTS STC-44 2 1/8"S1FA 1 1/2" METAL 'Z' FURRING WITH (1) LAYER 5/8" GYPSUM WALL BOARD ONE SIDE M8E 7 5/8" CONCRETE MASONRY UNIT WITH (1) LAYER 5/8" GYPSUM WALL BOARD OVER 1 1/2" METAL FURRING ONE SIDE 9 3/4"1'-0"S33A DOUBLE 3 5/8" METAL STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE 3 1/2" SPACE BETWEEN STUDS C8A 8" CAST IN PLACE CONCRETE * 2 HR RATED (refer to 'equivalent thickiness' tables in IBC-721.2.1.1) * ACOUSTIC ATTEN. COMPONENTS STC >54 (rating based on concrete density-verify concrete density)8"7 1/4"F6A 6" METAL STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE 4 1/4"S3C 3 5/8" METAL STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD ONE SIDE 4 1/4"M8F 7 5/8" CONCRETE MASONRY UNIT WITH (1) LAYER 5/8" GYPSUM BOARD OVER 2 1/2" METAL STUD FRAMING, NON-STRUCTURAL, ONE SIDE * 2 HR RATED U905 * ACOUSTIC ATTEN. COMPONENTS STC ??10 3/4"3 1/8"S2C 2 1/2" METAL STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD ONE SIDE 2 2 4'-0"FIRE EXTINGUISHERFIRE EXTINGUISHERCABINET, FIREHOSECABINET, HOSE VALVECABINET, OR ANYCOMBINATION OF THEABOVE6"ELECTRICAL, SWITCHESOR RECEPTACLES OVERCOUNTERS OR SIMILARWORK SURFACES2"2" 2"2"1'-3"ELECTRICAL ORRECEPTACLE TRIMPLATESDOOR FRAME OR WINDOW FRAME 4'-0"6"6'-8"WALL END OR EDGE (WHERE OCCURS) FIRE ALARM NOTE: ENTIRE LENS TO BE NOT LESS THAN 80" AND NOT GREATER THAN 96" AFF THERMOSTAT OR TEMPERATURE CONTROL TELEPHONES, DOOR SWITCHES, DOOR CONTROLLERS, FIRE ALARM PULL SWITCHES AND SIMILAR ITEMS (THE INTENT IS TO ALIGN TOPS OF ALL OPERABLE ITEMS WHILE ALLOWING THE OPERABLE PARTS TO BE LESS THAN 4'-0" AFF) ELECTRICAL RECEPTACLES -SINGLE, GANGED, OR SEPARATED BY 2" WINDOW, DOOR OR "FEATURE" THAT SEPARATES WALL INTO SEGMENTS EQEQ WALL END OR EDGE (WHERE OCCURS) WALL SEGMENT 24" WIDE OR LESS 2"2" NOTES: 1. USE THIS DETAIL TO LOCATE DEVICES THAT ARE INDICATED ON THE DRAWINGS BUT NOT LOCATED BY DIMENSION, OR TO LOCATE REQUIRED DEVICES THAT ARE NOT INDICATED ON THE DRAWINGS. 2. ALIGN MULTIPLE DEVICES HORIZONTALLY AND/OR VERTICALLY AS DETAILED. 3. ITEMS OTHER THAN ELECTRICAL RECEPTACLES SHALL BE MOUNTED NEAR DOORWAYS OR INTERSECTING WALLS AS DETAILED SO AS NOT TO INTERFERE WITH THE PLACEMENT OF ART OR FUNITURE -EXCEPT THAT WHERE THE WALL SEGMENT IS LESS THAN 24" WIDE, CENTER THE DEVICES AS DETAILED. ELECTRICAL RECEPTACLES - SINGLE, GANGED, OR SEPARATED BY 2" COLUMN OR PILASTER FIRE ALARM NOTE: ENTIRE LENS TO BE NOT LESS THAN 80" AND NOT GREATER THAN 96" AFF EQEQ. TELEPHONES, DOOR SWITCHES, DOOR CONTROLLERS, FIRE ALARM PULL SWITCHES AND SIMILAR ITEMS 2"2" WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT * 04A AT WOMEN'S RESTROOMS ** AMBULATORY ACCESSIBLE TOILET COMPARTMENT * 04A AT WOMEN'S RESTROOMS TOILET COMPARTMENT * 04A AT WOMEN'S RESTROOMS * STANDARD TOILET COMPARTMENT TYPES - TYPICAL ACCESSORIES A B C 03C 05B 04A 03A 05D 05A 03C 03A 04A 04A 03A 03C 05D 05A 05D 05A REFERENCE STANDARD PLUMBING FIXTURE REQUIREMENTS AND STANDARD TOILET TOOM ACCESSORY MOUNTING HEIGHTS ON A-001 FOR ADDITIONAL INFORMATION UNLESS OTHERWISE NOTED.. REFERENCE A-411 FOR ACCESSORY LEGEND. EQ EQ 1'-5" EQ EQ TYPICAL DIMENSIONS UNLESS OTHERWISE NOTED 3'-0" A. ALL WALLS ARE TYPE S3A.D UNLESS NOTED OTHERWISE. B. PARTITION SYMBOLS APPEAR ON THE 1/8" = 1'-0" SCALE FLOOR PLANS. C. REFER TO FINISH AND CEILING PLANS FOR WALL FINISH, WALL BASE, AND CEILING INFORMATION. D. REFER TO WALL SECTIONS FOR EXTERIOR WALL CONSTRUCTION. E. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD IN ALL ROOMS CONTAINING OPERABLE PLUMBING FIXTURES AND WITHIN 4'-0" OF DRINKING FOUNTAINS / WATER COOLERS, UNLESS NOTED OTHERWISE. F. PROVIDE LATERAL BRACING AT 48" ON CENTER FOR NON- STRUCTURAL METAL FRAMED PARTITIONS WHICH EXTEND ABOVE THE CEILING UNLESS NOTED OTHERWISE. LATERAL BRACING NOT REQUIRED FOR PARTITIONS THAT EXTEND TO THE DECK ABOVE UNLESS NOTED OTHERWISE. G. PROVIDE FIRE RESISTIVE RATED GYPSUM BOARD AT ALL RATED ASSEMBLIES TO MEET ASSEMBLY REQUIREMENTS. H. PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL RATING AT ALL PENETRATIONS AND AT HEAD / FLOOR INTERSECTIONS WITH RATED ASSEMBLIES. I. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD, PENETRATIONS AND ADDITIONAL SPECIFIED SOUND ATTENUATION COMPONENTS AT SOUND RATED WALLS. J. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS INDICATED TO HAVE CERAMIC TILE, REFER TO FINISH PLANS. K. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING STRUCTURE TO PREVENT TRANSFER OF VERTICAL LOADS WHILE PROVIDING LATERAL SUPPORT AS SPECIFIED. L. WOOD OR METAL STUD SPACING SHALL BE 16” ON CENTER MAXIMUM UNLESS OTHERWISE REQUIRED BY DELEGATED DESIGN OR NOTED OTHERWISE. SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 F.A. Wilhelm Construction 3914 Prospect Street Indianapolis, Indiana 46203 317-359-5411 Construction Manager 1/14/2022 11:06:56 AMA-002 INTERIOR PARTITION TYPES AND STANDARD PARTITION DETAILS 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 INTERIOR PARTITION LEGEND INTERIOR PARTITION HEIGHT CODES INTERIOR PARTITION TYPES STANDARD-DEVICE MOUNTING GUIDELINES INTERIOR PARTITION NOTES 1 PERMIT SET 11/19/21 2 BULLETIN SET 01/13/22 01/13/22 02/23/22