HomeMy WebLinkAboutE101 - 17LV3 3 3 3333 3 3 HBHB3 SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH SMOKE DETECTOR TELEPHONE JACK TV/ DATA EXHAUST FAN DUPLEX OUTLET WEATHER PROOF OUTLET GROUND FAULT OUTLET 220V OUTLET RECESSED EYEBALL LIGHTEYE CEILING FIXTURE WALL MOUNT FIXTURE FLUORESCENT FIXTURE RECESSED FIXTURE TRACK FIXTURET UNDER CABINET FIXTURE EXTERIOR FLOOD LIGHT WIRE FOR PADDLE FAN WIRE FOR PADDLE FAN AND LIGHT KIT CS34 WP GFI 220V FLUSH MOUNT LED FIXTURE CS CS CS CS F F F CS PROVISION PROVISION G 220V DISPOSAL TO PHOTO CELL 2-CAR GARAGE KITCHEN MUD ROOM PANTRY OFFICE DINING GREAT ROOM MASTER BEDROOM LAUNDRY BEDROOM #2 BATH #2 POWDER FLEX ROOM FOYER LIGHT/FAN GFI GFI GFI GFI 42" GFI GFIGFI WP DN TO LIGHT BELOW UP 5/12 VAULTED CEILING SLOPESLOPE DEDICATED ATTIC ACCESSTO SWITCH ABOVE FLOODS LANAI 9'-6" H. CEILING GFI GFI PROVISION W.I.C. TO YARD LIGHT PROVISION CLG. OUTLET PROVISION PROVISION WP HDMI HDMI HDMI GFI42" IRRIGATION WD FRG. OVEN TV POWER/DATA IN NICHE LIGHT/FAN LIGHT/FAN LIGHT/FAN LIGHT/FAN 42" DROP ZONE MASTER BATH CUSTOMER:PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:Copyright © 2020 Wedgewood Building Co. LLC. Wedgewood Building Co., LLC32 First Street NECarmel, IN 46032317.669.6300www.wedgewoodbc.com11/23/2021 10:31:28 AM E2The Weiker ResidenceNew Product DevelopmentLot 17 @ Laura Vista Drive1ST FLOOR ELEC. PLAN WBCELECTRICAL PLAN NOTES: 1. REFER TO COVER PAGE FOR SPANISH TRANSLATIONS = REFERIRSE A LA PORTADA DE LAS TRADUCCIONES AL ESPAÑOL. 1/4" = 1'-0" 1 MAIN LEVEL ELECTRICAL PLAN Rev.No. Date DescriptionPERM I T S E T Not for C o n s t r u c ti o n 12/22/21