Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I50115318.19_Troy_Estates
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). February 7,2022 Liu, Xuegang Pages or sheets covered by this seal: I50115318 thru I50115384 My license renewal date for the state of Indiana is July 31, 2022. 19_Troy_Estates 19 Troy Estates IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE01 Truss Type Roof Special Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115318 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:03 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-z2eNxCLe_3aqWEOvS7GmhgdYy_evdrMn4idXm2znUMc Scale = 1:50.5 Sheet FrontFull Sheathing1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 29 30 3x4 3x4 4x6 3x4 3x4 5x6 8-0-08-0-0 16-0-08-0-0 -0-11-4 0-11-4 8-0-0 8-0-0 16-0-0 8-0-0 16-11-4 0-11-4 1-7-58-3-51-7-56-5-110.00 12 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.09 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 28=-161(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except 28=-153(LC 10), 22=-102(LC 11) Max Grav All reactions 250 lb or less at joint(s) 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except 28=261(LC 18), 22=309(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-110/260, 7-8=-132/301, 8-9=-132/301, 9-10=-110/260 WEBS 8-22=-341/118 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-11-4 to 2-0-12, Exterior(2N) 2-0-12 to 8-0-0, Corner(3R) 8-0-0 to 11-0-0, Exterior(2N) 11-0-0 to 16-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except (jt=lb) 28=153, 22=102. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 22, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE02 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115319 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:05 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-vRm8MuNuWgqYlYYIZYIEm5jo8oIZ5kc4X06eqxznUMa Scale = 1:80.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2425 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 3534 33 32 31 30 29 28 27 26 51 3x8 MT18HS 4x6 3x6 3x4 3x4 5x6 5x6 5x6 5x6 3x6 43-6-843-6-8 -1-0-0 1-0-0 18-2-0 18-2-0 38-2-0 20-0-0 43-6-8 5-4-8 1-4-511-11-88-9-1411-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [5:0-1-8,0-1-8], [12:0-3-0,0-1-12], [20:0-3-0,0-3-0], [22:0-3-0,0-1-12], [26:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.52 0.21 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 1 1 26 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 MT18HS Weight: 329 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 9-44,8-45,7-46,6-47,4-48,3-49: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-22. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 25-26, 22-29, 21-30, 20-31, 19-32, 18-33, 17-34, 16-36, 15-37, 14-38, 13-39, 12-40, 11-41, 10-43, 9-44, 23-28, 24-27 REACTIONS.All bearings 43-6-8. (lb) - Max Horz 50=288(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 50, 26, 31, 40, 41, 43, 44, 45, 46, 47, 28, 27 except 49=-166(LC 9) Max Grav All reactions 250 lb or less at joint(s) 26, 29, 30, 31, 32, 33, 34, 36, 37, 38, 39, 40, 41, 43, 44, 45, 46, 47, 48, 49, 28, 27 except 50=295(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-328/236 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=44ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 3-4-4, Exterior(2N) 3-4-4 to 18-2-0, Corner(3R) 18-2-0 to 22-6-4, Exterior(2N) 22-6-4 to 38-2-0, Corner(3R) 38-2-0 to 42-6-4, Exterior(2N) 42-6-4 to 43-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 50, 26, 31, 40, 41, 43, 44, 45, 46, 47, 28, 27 except (jt=lb) 49=166. 13) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE03 Truss Type Piggyback Base Structural Gable COMMON l l Gable l Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115320 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:06 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-NdKWZDOWH_yONh7U7GpTJJFxyCT9q?qDmfsCMNznUMZ Scale = 1:70.2 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 26 27 28 3x6 5x6 3x6 3x4 3x8 3x8 3x6 4x6 2x4 3x4 3x8 3x4 5x6 5x6 3x8 MT18HS 9-3-139-3-13 18-2-08-10-4 27-10-09-8-0 37-8-89-10-8 -1-0-0 1-0-0 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-7-6 6-5-5 31-0-11 6-5-5 37-8-8 6-7-13 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-6], [6:0-4-0,0-2-4], [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.64 0.95 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.55 0.08 (loc) 11-12 11-12 11 l/defl >999 >811 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 184 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,5-16,5-14: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-1 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 14-16. WEBS 1 Row at midpt 10-11, 5-14, 7-12 2 Rows at 1/3 pts 9-11 REACTIONS. (size)11=Mechanical, 2=0-3-8 Max Horz 2=298(LC 9) Max Grav 11=1795(LC 17), 2=1809(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2905/0, 3-5=-2718/7, 5-6=-1916/67, 6-7=-1603/78, 7-9=-1248/72 BOT CHORD 2-16=-79/2544, 14-16=-86/2105, 12-14=-57/1470, 11-12=-68/940 WEBS 3-16=-304/96, 5-16=0/666, 5-14=-725/74, 6-14=0/621, 7-14=-50/350, 7-12=-659/60, 9-12=0/1173, 9-11=-1736/17 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-9-4, Interior(1) 2-9-4 to 18-2-0, Exterior(2R) 18-2-0 to 23-6-0, Interior(1) 23-6-0 to 37-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115321 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:07 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-rquunZP82H4F?righzKirWoDeb?eZdyM?JblvpznUMY Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x4 3x4 4x6 3x4 3x4 15-8-015-8-0 -1-4-0 1-4-0 7-10-0 7-10-0 15-8-0 7-10-0 17-0-0 1-4-0 1-4-1110-6-51-4-1114.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-12], [6:Edge,0-1-14], [10:Edge,0-1-12], [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.10 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 94 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 6-16: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-16 REACTIONS.All bearings 15-8-0. (lb) - Max Horz 20=235(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 19, 15, 14, 13 except 20=-107(LC 8), 12=-100(LC 9) Max Grav All reactions 250 lb or less at joint(s) 12, 17, 18, 19, 15, 14, 13 except 20=253(LC 18), 16=418(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-257/337, 6-7=-257/337 WEBS 6-16=-455/276 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-4-0 to 1-10-0, Exterior(2N) 1-10-0 to 7-10-0, Corner(3R) 7-10-0 to 10-10-0, Exterior(2N) 10-10-0 to 17-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 19, 15, 14, 13 except (jt=lb) 20=107, 12=100. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE06 Truss Type Roof Special Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115322 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:08 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-J0RG_vPnpbC6c?HtEhrxOkLIK?I2I6nWDzLIRGznUMX Scale = 1:72.0 Sheet FrontFull Sheathing1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 30 29 28 27 26 25 24 23 22 21 20 19 18 17 31 32 4x6 4x6 3x6 5x6 3x4 19-11-819-11-8 19-11-8 19-11-8 12-0-110-5-07.00 12 Plate Offsets (X,Y)-- [1:0-3-12,Edge], [27:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.59 0.28 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 146 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 2-29,3-28,4-27,5-26: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-30, 2-29, 3-28, 4-27, 5-26 REACTIONS.All bearings 19-11-8. (lb) - Max Horz 30=-319(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-256/209, 7-8=-284/223, 8-9=-311/237, 9-10=-338/251, 10-11=-365/265, 11-13=-392/279, 13-14=-421/295, 14-15=-442/300, 15-16=-503/346 BOT CHORD 29-30=-292/444, 28-29=-292/444, 27-28=-292/444, 26-27=-291/444, 25-26=-291/444, 24-25=-291/444, 23-24=-291/444, 22-23=-291/444, 21-22=-291/444, 20-21=-291/444, 19-20=-291/444, 18-19=-291/444, 17-18=-291/444, 16-17=-291/444 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-12 to 3-1-12, Exterior(2N) 3-1-12 to 19-11-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE07 Truss Type Common Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115323 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:10 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GPZ1PbR1KCSqsJQFM5uPT9Qd9p03m?qphHqPV8znUMV Scale = 1:77.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 32 33 4x6 3x6 4x6 3x6 3x6 3x8 27-7-027-7-0 6-0-6 6-0-6 27-7-0 21-6-10 9-7-613-1-100-6-127.00 12 Plate Offsets (X,Y)-- [11:0-1-8,0-1-8], [16:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.69 0.18 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 180 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 4-28,3-29,2-30,5-27,6-26,7-24: 2x4 SPF No.2 WEDGE Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-31, 4-28, 3-29, 2-30, 5-27, 6-26, 7-24, 8-23 REACTIONS.All bearings 27-7-0. (lb) - Max Horz 31=-310(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 31, 28, 30, 27, 26, 24, 23, 22, 21, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 31, 28, 29, 30, 27, 26, 24, 23, 22, 21, 20, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 13-14=-276/216, 14-15=-313/239, 15-16=-376/281 BOT CHORD 30-31=-229/312, 29-30=-229/312, 28-29=-229/312, 27-28=-229/312, 26-27=-229/312, 24-26=-229/312, 23-24=-229/312, 22-23=-229/312, 21-22=-229/312, 20-21=-229/312, 19-20=-229/312, 18-19=-229/312, 17-18=-229/312, 16-17=-229/312 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-4 to 3-1-4, Exterior(2N) 3-1-4 to 6-0-6, Corner(3R) 6-0-6 to 9-0-6, Exterior(2N) 9-0-6 to 27-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 31, 28, 30, 27, 26, 24, 23, 22, 21, 20, 19, 18, 17, 16. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE08 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115324 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:11 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-kb7PcxSf5WahTT?SwpPe0MzvHDNYVTUyvxZz2aznUMU Scale = 1:55.6 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 38 39 3x4 3x4 3x4 3x4 4x6 6x6 6x6 21-0-021-0-0 -1-3-4 1-3-4 6-6-0 6-6-0 14-6-0 8-0-0 21-0-0 6-6-0 22-3-4 1-3-4 1-6-119-1-111-6-119-1-1114.00 12 Plate Offsets (X,Y)-- [7:0-2-11,Edge], [13:0-2-11,Edge], [33:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.10 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 19 19 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 168 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 13-25,12-26,11-27,10-28,9-29,8-30,7-31: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 7-13. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 13-25, 12-26, 11-27, 10-28, 9-29, 8-30, 7-31 REACTIONS.All bearings 21-0-0. (lb) - Max Horz 37=-210(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 27, 28, 29, 32, 34, 35, 24, 23, 22 except 37=-150(LC 10), 20=-129(LC 9), 36=-137(LC 11), 21=-120(LC 10) Max Grav All reactions 250 lb or less at joint(s) 25, 26, 27, 28, 29, 30, 31, 32, 34, 35, 36, 24, 23, 22, 21 except 37=275(LC 18), 20=255(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-211/282, 13-14=-211/282 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-3-4 to 1-8-12, Exterior(2N) 1-8-12 to 6-6-0, Corner(3R) 6-6-0 to 9-6-0, Exterior(2N) 9-6-0 to 14-6-0, Corner(3R) 14-6-0 to 17-6-0, Exterior(2N) 17-6-0 to 22-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 28, 29, 32, 34, 35, 24, 23, 22 except (jt=lb) 37=150, 20=129, 36=137, 21=120. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE09 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115325 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:12 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-CnhnqHSHsqiY5caeTWwtYaV3?cidExf68bJWa1znUMT Scale = 1:73.0 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 23 22 21 20 19 18 17 16 15 14 13 24 25 3x4 3x4 3x6 3x4 3x4 13-6-813-6-8 1-10-8 1-10-8 13-6-8 11-8-0 10-10-511-11-87.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.18 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 13 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-12. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-23, 12-13, 11-14, 10-15, 9-16, 8-17, 7-18 , 6-19, 5-20, 4-21, 2-22 REACTIONS.All bearings 13-6-8. (lb) - Max Horz 23=23(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 23, 15, 16, 17, 18, 19, 20 except 13=-115(LC 12), 22=-139(LC 12) Max Grav All reactions 250 lb or less at joint(s) 23, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-12 to 1-10-8, Corner(3R) 1-10-8 to 4-10-8, Exterior(2N) 4-10-8 to 13-4-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 15, 16, 17, 18, 19, 20 except (jt=lb) 13=115, 22=139. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE10 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115326 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:13 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-gzF91dTvd7rPjm9q1ER65n2D2022zLoFNF236TznUMS Scale = 1:54.1 Sheet FrontFull Sheathing1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 3x6 3x4 3x4 3x4 15-7-215-7-2 15-7-2 15-7-2 9-1-27.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.17 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-14 REACTIONS.All bearings 15-7-2. (lb) - Max Horz 1=238(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 Max Grav All reactions 250 lb or less at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-417/270, 2-4=-379/247, 4-5=-350/235, 5-6=-319/219, 6-7=-288/205, 7-8=-257/190 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-6-8 to 3-7-2, Exterior(2N) 3-7-2 to 15-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss GE11 Truss Type Piggyback Base Structural Gable l l l Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115327 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:15 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-cMMvSIVA9l57y4JD9fTaAC7QWqdbRFcYqZXABMznUMQ Scale = 1:58.6 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 12 11 10 9 7 45 46 47 8 8x14 MT18HS 8x14 MT18HS 3x4 3x4 3x8 8x8 3x4 8x8 3x8 3x8 3x8 5x6 3x8 3x8 7-4-07-4-0 15-4-08-0-0 15-8-00-4-0 22-8-07-0-0 -1-4-0 1-4-0 7-4-0 7-4-0 15-4-0 8-0-0 22-8-0 7-4-0 24-0-0 1-4-0 1-4-119-11-51-4-119-11-514.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-7], [3:0-10-12,0-1-8], [4:0-10-12,0-1-8], [5:Edge,0-2-7], [7:Edge,0-2-8], [10:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.84 0.54 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.20 0.01 (loc) 9-11 9-11 7 l/defl >999 >923 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 193 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-9: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-9 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-15 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 4-9 REACTIONS. (size)12=0-3-8, 7=7-3-8, 8=0-3-8 Max Horz 12=-224(LC 10) Max Uplift 12=-44(LC 12), 7=-78(LC 12) Max Grav 12=905(LC 17), 7=687(LC 18), 8=603(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-802/99, 3-4=-287/163, 4-5=-533/135, 2-12=-799/82, 5-7=-593/112 BOT CHORD 11-12=-182/393, 9-11=0/516, 8-9=-126/285, 7-8=-126/285 WEBS 3-11=0/377, 3-9=-343/9, 2-11=-71/335 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 7-4-0, Exterior(2R) 7-4-0 to 11-6-15, Interior(1) 11-6-15 to 15-4-0, Exterior(2R) 15-4-0 to 19-6-15, Interior(1) 19-6-15 to 24-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) The Fabrication Tolerance at joint 3 = 12%, joint 4 = 12% 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss M01 Truss Type Monopitch Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115328 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:15 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-cMMvSIVA9l57y4JD9fTaAC7ZDqiORDZYqZXABMznUMQ Scale: 3/16"=1' 1 2 4 35 2x4 3x4 2x4 3x4 4-5-84-5-8 4-5-8 4-5-8 9-5-812-0-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.29 0.24 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-3: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3, 1-4 REACTIONS. (size)3=0-3-8, 4=0-3-8 Max Horz 4=55(LC 12) Max Uplift 3=-134(LC 12) Max Grav 3=238(LC 17), 4=227(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 1-3=-146/268 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-4 to 3-1-4, Interior(1) 3-1-4 to 4-3-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=134. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss M02 Truss Type Piggyback Base Qty 8 Ply 1 19 Troy Estates Job Reference (optional) I50115329 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:16 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-4YwIfeWow2D_aEuPiM?pjQgdBEzoAenh3DHjjoznUMP Scale = 1:68.6 1 2 3 4 7 6 5 8 9 10 11 12 13 3x6 5x6 3x4 3x8 2x4 3x8 3x8 7-7-47-7-4 13-6-85-11-4 1-10-8 1-10-8 7-7-4 5-8-12 13-6-8 5-11-4 10-10-511-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [5:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.72 0.55 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.25 -0.00 (loc) 6-7 6-7 5 l/defl >978 >631 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5, 3-6, 4-6, 1-7, 2-7 REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=298(LC 9) Max Uplift 5=-167(LC 9), 7=-116(LC 8) Max Grav 5=723(LC 17), 7=719(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-619/229 BOT CHORD 6-7=-302/343 WEBS 2-6=-166/411, 3-6=-407/138, 4-6=-240/564, 2-7=-586/332 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 1-10-8, Exterior(2R) 1-10-8 to 6-1-7, Interior(1) 6-1-7 to 13-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=167, 7=116. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss M03 Truss Type Monopitch Qty 2 Ply 1 19 Troy Estates Job Reference (optional) I50115330 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:17 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ZlUgt_WQhMLrBOTbG4W2FdDtXdMDvBqrIt0HFEznUMO Scale = 1:14.9 1 2 4 5 3 2x4 2x4 2x4 5-11-85-11-8 -0-11-4 0-11-4 4-3-8 4-3-8 5-11-8 1-8-0 0-4-02-3-131-9-31-4-52-3-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.43 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.21 -0.00 (loc) 2-5 2-5 3 l/defl >467 >233 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 3=0-3-8 Max Horz 2=57(LC 11) Max Uplift 2=-23(LC 12) Max Grav 2=206(LC 1), 3=312(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 5) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss M04 Truss Type Monopitch Qty 6 Ply 1 19 Troy Estates Job Reference (optional) I50115331 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:17 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ZlUgt_WQhMLrBOTbG4W2FdDxUdPUvBqrIt0HFEznUMO Scale = 1:11.0 1 2 3 4 2x4 2x4 2x4 -0-11-4 0-11-4 3-11-8 3-11-8 0-4-01-7-131-4-50-3-81-7-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=39(LC 9) Max Uplift 2=-24(LC 12) Max Grav 2=221(LC 1), 4=137(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 3-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PB01 Truss Type Piggyback Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115332 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:18 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1x224KX2SgTipX2oqn1Horl_m1gIeay_WXmqohznUMN Scale: 3/16"=1' Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 13 12 11 10 9 1 14 15 16 3x6 3x6 3x4 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 19-6-819-6-8 17-8-6 17-8-6 19-6-8 1-10-2 0-4-510-2-60-1-89-1-80-1-87.00 12 Plate Offsets (X,Y)-- [7:0-3-0,Edge], [9:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.48 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.08 -0.00 (loc) 10-12 10-12 9 l/defl >999 >893 n/a L/d 240 180 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud *Except* 2-11: 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 6-10 REACTIONS.All bearings 19-6-8. (lb) - Max Horz 1=260(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 10, 1 Max Grav All reactions 250 lb or less at joint(s) 9, 9, 2, 1 except 12=678(LC 17), 13=467(LC 17), 10=579(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-378/325, 2-3=-307/261 WEBS 4-12=-389/140, 3-13=-299/99, 6-10=-320/163 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 17-8-6, Exterior(2E) 17-8-6 to 19-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 10, 1. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PB02 Truss Type Piggyback Qty 9 Ply 1 19 Troy Estates Job Reference (optional) I50115333 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:19 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-V7cQIgYgDzbYRhc_OUYWK2IFER21N4V7lBVOK7znUMM Scale = 1:38.9 2 3 4 5 6 11 10 9 8 1 12 13 14 15 7 16 17 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 3x4 20-0-020-0-0 10-0-0 10-0-0 20-0-0 10-0-0 -0-0-45-9-125-10-00-1-00-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.29 0.32 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-9: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 1=88(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 11, 8, 6 except 1=-332(LC 17), 7=-305(LC 18) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 2=588(LC 17), 10=329(LC 17), 11=481(LC 17), 8=480(LC 18), 6=576(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-300/97, 5-8=-300/97 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 10-0-0, Exterior(2R) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-7-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11, 8, 6 except (jt=lb) 1=332, 7=305. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PB03 Truss Type Piggyback Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115334 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:20 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-zKAoV0ZI_HjP2rBAxC3ltGqPMrNx6VqH_rFxsZznUML Scale = 1:39.2 2 3 4 5 6 7 12 11 10 9 1 13 14 15 16 8 17 18 5x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 3x4 19-6-819-6-8 10-0-0 10-0-0 19-6-8 9-6-8 0-4-55-8-80-1-80-2-150-1-120-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.34 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.07 0.00 (loc) 9-11 9-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-10: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 19-6-8. (lb) - Max Horz 1=-87(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 8, 2, 12, 9 Max Grav All reactions 250 lb or less at joint(s) 1, 8, 2, 7 except 11=638(LC 17), 12=498(LC 17), 9=505(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-11=-353/55, 3-12=-341/109, 6-9=-336/104 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 10-0-0, Exterior(2R) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 2, 12, 9. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PB04 Truss Type Piggyback Qty 15 Ply 1 19 Troy Estates Job Reference (optional) I50115335 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:21 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-RWkBjMZwlbrGg?mNVva_QTNagFkar_KQDV_UO?znUMK Scale = 1:40.4 2 3 4 6 5 1 7 8 9 2x4 2x4 3x4 2x4 2x4 11-8-011-8-00-4-56-8-20-1-80-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.35 0.32 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.09 -0.00 (loc) 5-6 5-6 5 l/defl >999 >734 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-0. (lb) - Max Horz 1=176(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 2, 6 except 1=-212(LC 17) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 5=261(LC 17), 2=411(LC 17), 6=618(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-322/298 WEBS 3-6=-372/160 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 11-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2, 6 except (jt=lb) 1=212. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PB05 Truss Type Piggyback Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115336 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:22 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-viIZwiaZWuz7I9LZ3d5Dyhwgle1EaOxaR9k2xSznUMJ Scale: 3/16"=1' 2 3 4 5 6 7 8 13 12 11 10 9 1 14 15 16 3x6 3x6 3x4 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 19-6-819-6-8 17-8-6 17-8-6 19-6-8 1-10-2 0-4-510-2-60-1-89-1-80-1-87.00 12 Plate Offsets (X,Y)-- [7:0-3-0,Edge], [9:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.48 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.08 -0.00 (loc) 10-12 10-12 9 l/defl >999 >893 n/a L/d 240 180 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud *Except* 2-11: 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 6-10 REACTIONS.All bearings 19-6-8. (lb) - Max Horz 1=260(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 10, 1 Max Grav All reactions 250 lb or less at joint(s) 9, 9, 2, 1 except 12=678(LC 17), 13=467(LC 17), 10=579(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-378/325, 2-3=-307/261 WEBS 4-12=-389/140, 3-13=-299/99, 6-10=-320/163 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 17-8-6, Exterior(2E) 17-8-6 to 19-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 10, 1. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PB06 Truss Type Piggyback Qty 13 Ply 1 19 Troy Estates Job Reference (optional) I50115337 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:22 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-viIZwiaZWuz7I9LZ3d5Dyhwkqe5XaSMaR9k2xSznUMJ Scale: 3/8"=1' 2 3 4 6 1 5 4x6 2x4 2x4 2x4 8-0-08-0-0 4-0-0 4-0-0 8-0-0 4-0-0 0-5-104-6-80-1-80-1-00-1-814.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.39 0.21 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 2-6 2-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=86(LC 11) Max Uplift All uplift 100 lb or less at joint(s) except 1=-388(LC 17), 5=-291(LC 18), 5=-244(LC 1), 2=-228(LC 12), 4=-203(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=571(LC 17), 4=486(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-174/310 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-0-0, Exterior(2R) 4-0-0 to 7-0-0, Interior(1) 7-0-0 to 7-9-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 1, 291 lb uplift at joint 5, 228 lb uplift at joint 2 and 203 lb uplift at joint 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PBE01 Truss Type Piggyback Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115338 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:25 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-KHzhYjdRopLi9c48klfwaJYK9s9Pnp5077yiXnznUMG Scale = 1:38.6 Sheet Front Full Sheathing1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 1 28 29 15 4x6 3x4 4x6 3x4 20-0-020-0-0 10-0-0 10-0-0 20-0-0 10-0-0 -0-0-45-9-125-10-00-1-00-1-87.00 12 Plate Offsets (X,Y)-- [21:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.07 0.07 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 78 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 14-21: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 1=88(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 15, 24, 25, 26, 27, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 1, 15, 2, 22, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-0, Interior(1) 3-4-0 to 10-0-0, Exterior(2R) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-7-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 15, 24, 25, 26, 27, 19, 18, 17, 16. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PBE02 Truss Type Piggyback Qty 2 Ply 1 19 Troy Estates Job Reference (optional) I50115339 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:26 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-oUX4m3d3Z7TZnmfKITA97X4WAFWCWGa9MniF4DznUMF Scale = 1:30.1 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 14 13 12 11 10 1 9 4x6 8-0-08-0-0 4-0-0 4-0-0 8-0-0 4-0-0 -0-0-44-7-124-8-00-1-00-1-814.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=-85(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 2, 8, 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 1, 9, 2, 8, 12, 13, 14, 11, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-0-0, Exterior(2R) 4-0-0 to 7-0-0, Interior(1) 7-0-0 to 7-9-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 9, 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 2, 8, 13, 14, 11, 10. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss PBE03 Truss Type Piggyback Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115340 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:27 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-Gg5SzPehKRbQOwEWsAhOfkddyfqbFiGJbRRpcfznUME Scale = 1:33.3Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 1 17 18 3x4 11-8-011-8-0-0-0-46-9-106-8-20-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-0. (lb) - Max Horz 1=175(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 2, 11, 12, 13, 14, 15, 16 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 2, 11, 12, 13, 14, 15, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-318/265 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 11-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 2, 11, 12, 13, 14, 15, 16. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T01 Truss Type Roof Special Qty 9 Ply 1 19 Troy Estates Job Reference (optional) I50115341 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:28 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ksfqBlfJ5kjH04ojPtCdCyAoh34S_yXSq5BM85znUMD Scale = 1:50.7 1 2 3 4 5 10 9 8 7 6 11 12 2x4 5x6 4x8 5x6 2x4 6x8 3x4 3x6 3x4 3x6 4-1-44-1-4 8-0-03-10-12 11-10-123-10-12 16-0-04-1-4 4-1-4 4-1-4 8-0-0 3-10-12 11-10-12 3-10-12 16-0-0 4-1-4 1-7-58-3-51-7-56-5-110.00 12 10.00 12 Plate Offsets (X,Y)-- [5:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.49 0.90 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.33 0.58 (loc) 8 8 6 l/defl >999 >580 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=-146(LC 10) Max Grav 10=632(LC 1), 6=632(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-627/68, 1-2=-1790/93, 2-3=-2290/0, 3-4=-2290/0, 4-5=-1790/62, 5-6=-621/46 BOT CHORD 8-9=-94/1843, 7-8=-47/1733 WEBS 3-8=0/2651, 4-8=-124/570, 4-7=-393/61, 5-7=-6/1406, 2-8=-37/448, 2-9=-393/59, 1-9=-1/1406 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-4 to 3-1-4, Interior(1) 3-1-4 to 8-0-0, Exterior(2R) 8-0-0 to 11-0-0, Interior(1) 11-0-0 to 15-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 10, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T02 Truss Type Common Qty 2 Ply 1 19 Troy Estates Job Reference (optional) I50115342 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:29 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-C2DCO5gys2s8eENvzbjsk9ip5TOAjbOc2kwvgYznUMC Scale: 3/16"=1' 1 2 3 4 5 8 7 6910 4x6 5x16 MT18HS 5x16 MT18HS 2x4 7-10-07-10-0 15-8-07-10-0 -1-4-0 1-4-0 7-10-0 7-10-0 15-8-0 7-10-0 17-0-0 1-4-0 1-4-1110-6-51-4-1114.00 12 Plate Offsets (X,Y)-- [6:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.90 0.59 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.21 0.01 (loc) 6-7 6-7 6 l/defl >999 >881 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 61 lb FT = 20% GRIP 197/144 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=236(LC 11) Max Uplift 8=-22(LC 12), 6=-22(LC 12) Max Grav 8=828(LC 18), 6=828(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-715/86, 3-4=-715/86, 2-8=-675/104, 4-6=-675/104 BOT CHORD 7-8=0/406, 6-7=0/406 WEBS 3-7=0/487 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 7-10-0, Exterior(2R) 7-10-0 to 10-10-0, Interior(1) 10-10-0 to 17-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T03 Truss Type Roof Special Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115343 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:30 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-gFmacRgadM_?FNy5XIF5HNF39tjrSualHOgTD_znUMB Scale = 1:67.1 1 2 3 4 5 8 7 69103x8 3x4 3x6 3x16 MT18HS 3x6 4x6 2x4 3x4 9-10-139-10-13 19-11-810-0-11 6-8-1 6-8-1 13-1-9 6-5-9 19-11-8 6-9-15 12-0-110-5-07.00 12 Plate Offsets (X,Y)-- [1:0-0-13,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.69 0.80 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.37 -0.55 0.02 (loc) 6-8 6-8 5 l/defl >638 >428 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 81 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-8, 2-8 REACTIONS. (size)8=0-3-8, 5=0-3-8 Max Horz 8=-319(LC 8) Max Uplift 8=-14(LC 8) Max Grav 8=983(LC 18), 5=881(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1067/74, 4-5=-1259/52 BOT CHORD 6-8=-14/605, 5-6=0/1040 WEBS 2-8=-847/87, 2-6=0/793, 4-6=-354/114 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 19-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T04 Truss Type Common Qty 13 Ply 1 19 Troy Estates Job Reference (optional) I50115344 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:30 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-gFmacRgadM_?FNy5XIF5HNF0othnSz7lHOgTD_znUMB Scale = 1:75.9 1 2 3 4 5 6 10 9 8 7 11 12 13 14 15 4x6 3x6 3x4 3x16 MT18HS4x8 3x6 4x6 2x4 4x6 5x6 6-0-66-0-6 16-9-010-8-10 27-7-010-10-0 6-0-6 6-0-6 13-2-2 7-1-12 20-3-14 7-1-12 27-7-0 7-3-2 9-7-613-1-100-6-127.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.78 0.82 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.61 0.04 (loc) 7-9 7-9 6 l/defl >795 >536 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 130 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 3-7,5-7: 2x3 SPF No.2 WEDGE Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 1-10 REACTIONS. (size)10=0-3-8, 6=Mechanical Max Horz 10=-310(LC 10) Max Grav 10=1314(LC 18), 6=1248(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-653/141, 2-3=-702/141, 3-5=-1625/66, 5-6=-1846/40, 1-10=-1222/63 BOT CHORD 9-10=-225/279, 7-9=0/1045, 6-7=0/1509 WEBS 2-9=-56/298, 3-9=-887/92, 3-7=0/824, 5-7=-367/122, 1-9=-49/970 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-0-6, Exterior(2R) 6-0-6 to 9-0-6, Interior(1) 9-0-6 to 27-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T06 Truss Type Common Qty 2 Ply 1 19 Troy Estates Job Reference (optional) I50115345 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:31 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-8RKzpnhCOf6rtXXI50mKqaoAYG10BQNuW2P0lQznUMA Scale = 1:75.9 1 2 3 4 5 6 10 9 8 7 11 12 13 14 15 4x6 3x6 3x4 3x16 MT18HS4x8 3x6 4x6 2x4 5x6 4x6 6-0-66-0-6 16-9-010-8-10 27-7-010-10-0 6-0-6 6-0-6 13-2-2 7-1-12 20-3-14 7-1-12 27-7-0 7-3-2 9-7-613-1-100-6-127.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.78 0.82 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.61 0.04 (loc) 7-9 7-9 6 l/defl >795 >536 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 130 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 3-7,5-7: 2x3 SPF No.2 WEDGE Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 1-10 REACTIONS. (size)10=0-3-8, 6=Mechanical Max Horz 10=-310(LC 10) Max Grav 10=1314(LC 18), 6=1248(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-653/141, 2-3=-702/141, 3-5=-1625/66, 5-6=-1846/40, 1-10=-1222/63 BOT CHORD 9-10=-225/279, 7-9=0/1045, 6-7=0/1509 WEBS 2-9=-56/298, 3-9=-887/92, 3-7=0/824, 5-7=-367/122, 1-9=-49/970 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-0-6, Exterior(2R) 6-0-6 to 9-0-6, Interior(1) 9-0-6 to 27-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T07 Truss Type Piggyback Base Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115346 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:32 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-cduL06iq9zEiVh6UejHZMoKKtgO2wzd2ki9aHtznUM9 Scale = 1:51.7 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 6x6 4x6 3x6 3x6 2x4 3x4 5x8 3x6 5x8 6-6-06-6-0 14-6-08-0-0 21-0-06-6-0 -1-3-4 1-3-4 6-6-0 6-6-0 14-6-0 8-0-0 21-0-0 6-6-0 22-3-4 1-3-4 1-6-119-1-111-6-119-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-1-12], [3:0-2-11,Edge], [4:0-3-2,0-2-0], [5:0-2-4,0-1-12], [7:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.87 0.71 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.48 0.02 (loc) 8-9 8-9 7 l/defl >913 >515 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-8: 2x4 SPF No.2, 2-11,5-7: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS. (size)11=0-3-8, 7=0-3-8 Max Horz 11=-212(LC 10) Max Uplift 11=-18(LC 12), 7=-18(LC 12) Max Grav 11=1075(LC 17), 7=1064(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-965/67, 3-4=-540/120, 4-5=-951/67, 2-11=-929/80, 5-7=-918/80 BOT CHORD 9-11=0/608, 8-9=0/612, 7-8=0/549 WEBS 3-9=0/390, 4-8=0/362 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 22-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T08 Truss Type Piggyback Base Qty 3 Ply 1 19 Troy Estates Job Reference (optional) I50115347 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:33 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-5qSjESjSwHMZ6rhgCRoov?tVj4hnfQzBzMu7pJznUM8 Scale = 1:51.7 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 3x8 5x6 4x6 5x10 MT18HS 3x6 2x4 3x4 3x6 5x8 6-6-06-6-0 14-6-08-0-0 21-0-06-6-0 6-6-0 6-6-0 14-6-0 8-0-0 21-0-0 6-6-0 22-3-4 1-3-4 1-6-119-1-111-6-119-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-3-2,0-2-0], [4:0-2-4,0-1-12], [6:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.86 0.87 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.54 0.02 (loc) 7-8 7-8 6 l/defl >802 >455 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 2-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF No.2, 1-10,4-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-7 REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=-199(LC 10) Max Uplift 6=-18(LC 12) Max Grav 10=989(LC 17), 6=1067(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-950/64, 2-3=-543/120, 3-4=-956/66, 1-10=-822/62, 4-6=-922/80 BOT CHORD 8-10=0/611, 7-8=0/615, 6-7=0/552 WEBS 2-8=0/371, 3-7=0/366 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 22-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T09 Truss Type Piggyback Base Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115348 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:34 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-Z005Roj4haUQk?Gsm8J1RDQgPU??Os1LC0egMlznUM7 Scale = 1:51.7 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 6x6 4x6 4x8 3x6 3x6 2x4 3x4 5x8 5x10 MT18HS 6-6-06-6-0 14-6-08-0-0 20-8-06-2-0 21-0-00-4-0 -1-3-4 1-3-4 6-6-0 6-6-0 14-6-0 8-0-0 20-8-0 6-2-0 21-0-0 0-4-0 1-6-119-1-110-3-89-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-1-12], [3:0-2-11,Edge], [4:0-3-2,0-2-0], [6:0-4-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.86 1.00 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.36 -0.64 0.02 (loc) 7-8 7-8 6 l/defl >673 >381 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-7: 2x4 SPF No.2, 2-10,5-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=202(LC 11) Max Uplift 10=-18(LC 12) Max Grav 10=1062(LC 17), 6=962(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-955/65, 3-4=-509/119, 4-5=-888/68, 2-10=-921/80, 5-6=-777/63 BOT CHORD 8-10=-36/586, 7-8=-35/590, 6-7=0/502 WEBS 3-8=0/406, 4-7=0/333 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 20-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T10 Truss Type Piggyback Base Qty 6 Ply 1 19 Troy Estates Job Reference (optional) I50115349 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:35 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1CaTf8kiSucHM9r3JsqG_QyvpuNV7JOURgNEuBznUM6 Scale = 1:51.7 1 2 3 4 9 8 7 6 5 10 11 12 13 14 3x8 5x6 4x6 3x8 5x10 MT18HS 3x6 2x4 3x4 5x10 MT18HS 6-6-06-6-0 14-6-08-0-0 20-8-06-2-0 21-0-00-4-0 6-6-0 6-6-0 14-6-0 8-0-0 20-8-0 6-2-0 21-0-0 0-4-0 1-6-119-1-110-3-89-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-3-2,0-2-0], [5:0-4-8,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.85 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.62 0.01 (loc) 6-7 6-7 5 l/defl >691 >394 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 89 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 2-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 5-8: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-6: 2x4 SPF No.2, 1-9,4-5: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-6 REACTIONS. (size)9=0-3-8, 5=0-3-8 Max Horz 9=182(LC 11) Max Grav 9=976(LC 17), 5=965(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-936/64, 2-3=-511/119, 3-4=-885/70, 1-9=-812/62, 4-5=-774/65 BOT CHORD 7-9=-35/588, 6-7=-34/592, 5-6=0/504 WEBS 2-7=0/386, 3-6=0/329 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 20-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T11 Truss Type Piggyback Base Qty 5 Ply 1 19 Troy Estates Job Reference (optional) I50115350 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:36 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-VP8ssUlLDCk8zIQFtZLVXeV3UHk?sbPefK7nQeznUM5 Scale = 1:82.4 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 24 25 26 27 28 29 30 31 32 4x8 5x6 3x6 5x6 3x4 10x16 3x6 3x4 2x4 3x4 3x8 3x4 5x6 5x6 3x6 3x4 3x6 9-2-49-2-4 18-2-08-11-12 28-2-010-0-0 38-0-09-10-0 38-2-00-2-0 43-6-85-4-8 -1-0-0 1-0-0 6-2-5 6-2-5 12-2-3 5-11-13 18-2-0 5-11-13 24-10-0 6-8-0 31-6-0 6-8-0 38-2-0 6-8-0 43-6-8 5-4-8 1-4-511-11-88-9-1411-11-87.00 12 Plate Offsets (X,Y)-- [3:0-4-0,Edge], [6:0-4-0,0-2-4], [10:0-4-0,0-2-4], [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.77 0.78 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.50 0.07 (loc) 16-18 16-18 13 l/defl >999 >911 n/a L/d 240 180 n/a PLATES MT20 Weight: 233 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-6: 2x4 SPF 2100F 1.8E, 10-11,1-3: 2x6 SP 2400F 2.0E BOT CHORD 2x4 SPF 2100F 1.8E *Except* 12-14: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-18,5-18,5-16,11-12: 2x3 SPF No.2, 7-16,9-13: 2x4 SPF 2100F 1.8E 2-19: 2x10 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-2 oc purlins, except end verticals, and 2-0-0 oc purlins (4-4-9 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. WEBS 1 Row at midpt 5-16, 7-16, 7-15, 9-13, 10-13, 11-12 REACTIONS. (size)19=0-3-8, 13=0-3-8, 12=Mechanical Max Horz 19=288(LC 11) Max Uplift 19=-10(LC 12), 12=-73(LC 12) Max Grav 19=1824(LC 17), 13=2191(LC 17), 12=247(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2351/27, 4-5=-2189/57, 5-6=-1776/108, 6-7=-1473/114, 7-9=-1138/119, 2-19=-1660/58 BOT CHORD 18-19=-91/1905, 16-18=-69/1860, 15-16=-35/1353, 13-15=-44/841 WEBS 5-18=0/276, 5-16=-567/83, 6-16=0/563, 7-16=-22/355, 7-15=-686/47, 9-15=0/1176, 9-13=-1697/0, 10-13=-368/97 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=44ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-4-4, Interior(1) 3-4-4 to 18-2-0, Exterior(2R) 18-2-0 to 24-3-15, Interior(1) 24-3-15 to 38-2-0, Exterior(2E) 38-2-0 to 43-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T12 Truss Type Piggyback Base Qty 4 Ply 1 19 Troy Estates Job Reference (optional) I50115351 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:37 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-zbiE4qmzzVs?bS?RRGtk3r2FIh2kb?Wnu_sLz4znUM4 Scale = 1:84.2 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 24 25 26 27 28 29 30 31 3x6 5x6 3x6 3x8 2x4 3x6 5x8 3x6 3x4 4x6 2x4 3x4 3x8 3x4 5x6 5x6 5x8 5x6 3x8 MT18HS 9-3-139-3-13 18-2-08-10-4 27-11-49-9-4 37-8-89-9-4 37-10-40-1-12 43-6-85-8-4 -0-11-4 0-11-4 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-8-3 6-6-3 31-2-5 6-6-3 37-8-8 6-6-3 38-2-0 0-5-8 43-6-8 5-4-8 0-4-510-11-811-11-88-9-141-0-011-11-87.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-6], [6:0-4-0,0-2-4], [10:0-5-0,0-1-12], [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.93 0.98 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.43 -0.68 -0.03 (loc) 14-15 14-15 12 l/defl >999 >665 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 215 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 16-18: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 10-13: 2x4 SPF 2100F 1.8E, 6-17,7-17,7-15,8-15,8-14: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-12 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 17-19. WEBS 1 Row at midpt 10-13, 5-17, 7-15, 11-13 2 Rows at 1/3 pts 8-14 REACTIONS. (size)2=0-3-8, 13=0-3-8, 12=Mechanical Max Horz 2=281(LC 11) Max Uplift 2=-18(LC 12), 13=-30(LC 9), 12=-169(LC 13) Max Grav 2=1763(LC 17), 13=2473(LC 19), 12=192(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2824/39, 3-5=-2637/61, 5-6=-1831/122, 6-7=-1529/126, 7-8=-1190/142, 10-11=-149/301, 11-12=-147/270 BOT CHORD 2-19=-17/2484, 17-19=-25/2042, 15-17=0/1379, 14-15=-9/809 WEBS 13-14=-2120/49, 10-14=-445/122, 3-19=-306/95, 5-19=0/669, 5-17=-726/73, 6-17=0/597, 7-17=-38/398, 7-15=-705/55, 8-15=0/1246, 8-14=-1832/0, 11-13=-306/78 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=44ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 3-5-0, Interior(1) 3-5-0 to 18-2-0, Exterior(2R) 18-2-0 to 24-3-15, Interior(1) 24-3-15 to 38-2-0, Exterior(2E) 38-2-0 to 43-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13 except (jt=lb) 12=169. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T13 Truss Type Piggyback Base Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115352 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:38 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-RnFcHAnbkp_sDcZe?_Ozc2aPu5OeKTlw7ecuVWznUM3 Scale = 1:70.2 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 26 27 28 3x6 5x6 3x6 3x4 3x8 3x8 3x6 4x6 2x4 3x4 3x8 3x4 5x6 5x6 3x8 MT18HS 9-3-139-3-13 18-2-08-10-4 27-10-09-8-0 37-8-89-10-8 -1-0-0 1-0-0 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-7-6 6-5-5 31-0-11 6-5-5 37-8-8 6-7-13 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-6], [6:0-4-0,0-2-4], [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.64 0.95 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.55 0.08 (loc) 11-12 11-12 11 l/defl >999 >811 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 184 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,5-16,5-14: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-1 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 14-16. WEBS 1 Row at midpt 10-11, 5-14, 7-12 2 Rows at 1/3 pts 9-11 REACTIONS. (size)11=Mechanical, 2=0-3-8 Max Horz 2=298(LC 9) Max Grav 11=1795(LC 17), 2=1809(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2905/0, 3-5=-2718/7, 5-6=-1916/67, 6-7=-1603/78, 7-9=-1248/72 BOT CHORD 2-16=-79/2544, 14-16=-86/2105, 12-14=-57/1470, 11-12=-68/940 WEBS 3-16=-304/96, 5-16=0/666, 5-14=-725/74, 6-14=0/621, 7-14=-50/350, 7-12=-659/60, 9-12=0/1173, 9-11=-1736/17 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-9-4, Interior(1) 2-9-4 to 18-2-0, Exterior(2R) 18-2-0 to 23-6-0, Interior(1) 23-6-0 to 37-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T14 Truss Type Piggyback Base Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115353 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:39 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-v_p_UWnDV76jqm8qYhvC8G7eiVnv31o4LILR1zznUM2 Scale = 1:63.1 1 2 3 4 5 6 7 8 12 11 10 9 13 14 15 16 17 18 19 20 3x6 5x6 3x4 4x6 3x6 4x6 3x4 2x4 3x4 3x8 3x4 10-1-1210-1-12 18-2-08-0-4 29-10-011-8-0 -1-0-0 1-0-0 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 23-10-12 5-8-12 29-10-0 5-11-4 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-3,0-1-8], [6:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.44 0.69 0.48 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.56 0.01 (loc) 2-12 2-12 9 l/defl >437 >213 n/a L/d 240 180 n/a PLATES MT20 Weight: 150 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 9-11: 2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-12,5-12,5-10: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 5-12, 6-10, 7-9 REACTIONS. (size)9=Mechanical, 2=0-3-8, 12=0-3-8 Max Horz 2=297(LC 9) Max Uplift 9=-55(LC 9), 2=-1(LC 12) Max Grav 9=920(LC 17), 2=460(LC 18), 12=1488(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-357/57, 5-6=-638/87, 6-7=-473/86 BOT CHORD 2-12=-166/268, 10-12=-141/269, 9-10=-107/363 WEBS 3-12=-364/95, 5-12=-925/39, 5-10=0/343, 7-10=-5/278, 7-9=-663/95 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 18-2-0, Exterior(2R) 18-2-0 to 22-4-15, Interior(1) 22-4-15 to 29-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T15 Truss Type Piggyback Base Qty 6 Ply 1 19 Troy Estates Job Reference (optional) I50115354 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:40 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-NANMirorGQEaSwj06PQRhTfnQv6voP7Day5?ZPznUM1 Scale = 1:73.7 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 22 23 24 25 3x6 4x6 3x8 3x8 2x4 3x4 2x4 2x4 3x8 2x4 4x6 6x8 3x8 3x4 5x8 3x6 0-0-12 0-0-12 10-1-12 10-1-0 10-2-8 0-0-12 12-2-0 1-11-8 18-2-0 6-0-0 27-11-8 9-9-8 29-10-0 1-10-8 29-10-12 0-0-12 -0-11-4 0-11-4 5-3-11 5-3-11 10-1-12 4-10-1 12-2-0 2-0-4 18-2-0 6-0-0 23-0-12 4-10-12 27-11-8 4-10-12 29-10-0 1-10-8 0-4-510-11-80-8-07.00 12 Plate Offsets (X,Y)-- [2:0-3-3,0-1-8], [7:0-3-8,0-2-0], [13:0-2-4,0-2-8], [15:0-4-8,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.57 0.71 0.79 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.44 -0.68 0.03 (loc) 13-14 13-14 11 l/defl >531 >343 n/a L/d 240 180 n/a PLATES MT20 Weight: 166 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 13-15: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 10-11,9-12,8-14,8-13: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 6-16, 9-12, 7-14, 8-13 REACTIONS. (size)11=Mechanical, 17=0-3-8, 2=0-3-8 Max Horz 2=297(LC 9) Max Uplift 11=-51(LC 9), 2=-1(LC 12) Max Grav 11=868(LC 17), 17=1548(LC 17), 2=418(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-326/67, 6-7=-617/78, 7-8=-453/79, 10-11=-812/45 BOT CHORD 13-14=-104/394 WEBS 6-15=-749/10, 3-17=-354/87, 5-17=-925/113, 5-15=-97/701, 6-14=0/407, 8-13=-497/64, 10-13=-92/827 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 18-2-0, Exterior(2R) 18-2-0 to 22-4-15, Interior(1) 22-4-15 to 29-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss T16 Truss Type Piggyback Base Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115355 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:41 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-sMxlvBpT1kMR44IDg6xgDhCzrITkXs7NpcqY6rznUM0 Scale = 1:70.2 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 26 27 28 3x6 5x6 3x6 3x4 3x8 3x6 3x6 4x6 2x4 3x4 3x8 3x4 3x4 3x4 3x8 MT18HS 10-1-1210-1-12 18-2-08-0-4 27-10-09-8-0 37-8-89-10-8 -1-0-0 1-0-0 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-7-6 6-5-5 31-0-11 6-5-5 37-8-8 6-7-13 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-3,0-1-8], [6:0-4-0,0-2-4], [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.47 0.67 0.81 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.51 0.02 (loc) 11-12 11-12 11 l/defl >999 >641 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 184 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,5-16,5-14: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 5-16, 6-14, 7-14, 7-12, 9-11 REACTIONS. (size)11=Mechanical, 2=0-3-8, 16=0-3-8 Max Horz 2=298(LC 9) Max Uplift 11=-15(LC 9), 2=-1(LC 12) Max Grav 11=1286(LC 17), 2=429(LC 18), 16=1898(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-305/58, 5-6=-893/75, 6-7=-696/86, 7-9=-832/75 BOT CHORD 14-16=-149/335, 12-14=-82/858, 11-12=-81/641 WEBS 3-16=-361/96, 5-16=-1308/40, 5-14=0/610, 7-14=-312/15, 9-12=0/644, 9-11=-1141/40 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-9-4, Interior(1) 2-9-4 to 18-2-0, Exterior(2R) 18-2-0 to 23-6-0, Interior(1) 23-6-0 to 37-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss TG03 Truss Type Piggyback Base Girder Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115356 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:42 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-KZV77Xq5o2UIhDtPEqSvmul3_ip7GHRW2Ga6eHznUM? Scale = 1:54.1 1 2 3 4 9 8 7 6 5 10 11 12 13 14 15 16 17 18 19 20 4x8 8x14 MT18HS 8x14 MT18HS 4x8 5x10 MT18HS 4x6 8x8 6x10 8x8 6-6-06-6-0 14-6-08-0-0 20-8-06-2-0 21-0-00-4-0 6-6-0 6-6-0 14-6-0 8-0-0 20-8-0 6-2-0 21-0-0 0-4-0 1-6-119-1-110-5-89-1-1114.00 12 Plate Offsets (X,Y)-- [1:0-3-4,0-1-12], [2:0-10-12,0-1-8], [3:0-10-12,0-1-8], [4:0-3-8,0-1-8], [5:0-5-0,0-0-8], [6:0-4-0,0-4-8], [7:0-2-8,0-4-12], [9:0-0-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.83 0.66 0.93 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.13 -0.24 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 122 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 2-6: 2x4 SPF No.2, 1-9,4-5: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-5-4 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-6 REACTIONS. (size)9=0-3-8, 5=0-3-8 Max Horz 9=180(LC 7) Max Uplift 9=-578(LC 5), 5=-775(LC 5) Max Grav 9=3693(LC 38), 5=3478(LC 38) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3226/613, 2-3=-1904/517, 3-4=-3036/742, 1-9=-2870/498, 4-5=-2848/639 BOT CHORD 7-9=-198/594, 6-7=-427/2122 WEBS 2-7=-309/2161, 2-6=-401/95, 3-6=-502/1892, 1-7=-345/1599, 4-6=-429/1777 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=578, 5=775. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 93 lb up at 2-0-12, 199 lb down and 93 lb up at 4-0-12, 199 lb down and 93 lb up at 6-0-12, 199 lb down and 93 lb up at 8-0-12, 199 lb down and 93 lb up at 10-0-12, 197 lb down and 206 lb up at 12-0-12, 197 lb down and 206 lb up at 14-0-12, and 197 lb down and 206 lb up at 16-0-12, and 197 lb down and 206 lb up at 18-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-9=-220(F=-200) Continued on page 2 February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss TG03 Truss Type Piggyback Base Girder Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115356 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:42 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-KZV77Xq5o2UIhDtPEqSvmul3_ip7GHRW2Ga6eHznUM? LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 12=-142(F) 13=-142(F) 14=-142(F) 15=-142(F) 16=-142(F) 17=46(F) 18=46(F) 19=46(F) 20=46(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss TG04 Truss Type Piggyback Base Girder Qty 1 Ply 2 19 Troy Estates Job Reference (optional) I50115357 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:43 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ol3VKtqkZLc8JNSbnX_8J6HJV68R?lRgGwJfAkznUM_ Scale = 1:56.0 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 19 20 21 22 23 24 25 26 6x6 4x6 3x8 MT18HS 10x16 3x6 3x6 4x8 3x6 3x4 6x6 2x4 5x6 3-9-43-9-4 7-4-03-6-12 15-4-08-0-0 15-8-00-4-0 18-10-123-2-12 22-8-03-9-4 -1-4-0 1-4-0 3-9-4 3-9-4 7-4-0 3-6-12 15-4-0 8-0-0 18-10-12 3-6-12 22-8-0 3-9-4 1-4-119-11-51-4-119-11-514.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-7], [4:0-2-11,Edge], [5:0-3-2,0-2-0], [7:Edge,0-2-7], [12:0-4-4,0-5-0], [13:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.46 0.72 0.89 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.27 0.01 (loc) 10-11 10-11 8 l/defl >999 >685 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 289 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS. (size)14=0-3-8, 10=0-3-8, 8=0-3-8 Max Horz 14=210(LC 7) Max Grav 14=4814(LC 21), 10=8344(LC 2), 8=1747(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3929/0, 3-4=-3209/0, 6-7=-884/0, 2-14=-3763/0, 7-8=-818/0 BOT CHORD 13-14=-140/324, 11-13=0/2493, 10-11=0/2118, 9-10=0/532 WEBS 3-13=0/1027, 3-11=-753/0, 4-11=0/4731, 4-10=-3427/0, 5-10=-433/0, 6-10=-1042/0, 6-9=0/1407, 2-13=0/2381, 7-9=0/399 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1171 lb down at 1-2-12, 1171 lb down at 3-2-12, 1171 lb down at 5-2-12, 1166 lb down at 7-2-12, 1156 lb down at 9-2-12, 1157 lb down at 11-2-12, 1171 lb down at 13-2-12, 1171 lb down at 15-2-12, 1171 lb down at 17-2-12, and 1171 lb down at 19-2-12, and 1171 lb down at 21-2-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss TG04 Truss Type Piggyback Base Girder Qty 1 Ply 2 19 Troy Estates Job Reference (optional) I50115357 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:44 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GxdtYDrMKfl?xX1nLEVNrJqUFWUgkChpVa3ChAznULz LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 5-7=-60, 8-14=-20 Concentrated Loads (lb) Vert: 11=-1075(B) 10=-1075(B) 17=-1075(B) 18=-1075(B) 19=-1075(B) 20=-1075(B) 21=-1075(B) 23=-1075(B) 24=-1075(B) 25=-1075(B) 26=-1075(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V13 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115358 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:44 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GxdtYDrMKfl?xX1nLEVNrJqWyWcnkIKpVa3ChAznULz Scale = 1:78.4 1 2 3 4 5 6 7 8 9 15 14 13 12 11 1016 17 3x6 4x6 3x6 3x4 3x6 3x4 22-1-822-1-8 11-0-12 11-0-12 22-1-8 11-0-12 0-0-412-10-140-0-414.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.35 0.20 0.46 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-3,7-9: 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud *Except* 9-14: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 5-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS.All bearings 22-1-8. (lb) - Max Horz 1=-242(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 9 except 13=-125(LC 12), 15=-109(LC 12), 11=-126(LC 12), 10=-108(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 9 except 12=327(LC 17), 13=515(LC 17), 15=411(LC 17), 11=513(LC 18), 10=413(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-13=-308/195, 2-15=-264/166, 6-11=-308/195, 8-10=-263/165 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-0-11, Interior(1) 3-0-11 to 11-0-12, Exterior(2R) 11-0-12 to 14-0-12, Interior(1) 14-0-12 to 21-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9 except (jt=lb) 13=125, 15=109, 11=126, 10=108. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V14 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115359 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:45 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-k7AFlZs_5ztsYhc_vy0cOXNhTwztTrnykEomEcznULy Scale = 1:42.4 1 2 3 4 7 6 53x4 2x4 3x4 2x4 2x4 2x4 2x4 12-1-3 12-1-3 0-0-47-0-117.00 12 Plate Offsets (X,Y)-- [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.14 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-1-3. (lb) - Max Horz 1=183(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=441(LC 17), 7=379(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-269/215 WEBS 3-6=-262/136 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 11-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V15 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115360 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:46 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-CKkeyvtcsG?jArBATfXrwkvu5JJYCJ96yuYJm3znULx Scale = 1:29.6 1 2 3 5 4 6 2x4 2x4 2x4 2x4 2x4 8-1-3 8-1-3 0-0-44-8-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-1-3, 4=8-1-3, 5=8-1-3 Max Horz 1=119(LC 9) Max Uplift 4=-10(LC 9), 5=-29(LC 12) Max Grav 1=114(LC 18), 4=123(LC 17), 5=373(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-280/138 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 7-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V16 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115361 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:46 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-CKkeyvtcsG?jArBATfXrwkvs4JHkCJ06yuYJm3znULx Scale = 1:14.8 1 2 3 4 2x4 2x4 2x4 4-1-3 4-1-3 0-0-42-4-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.23 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-1-3, 3=4-1-3 Max Horz 1=55(LC 9) Max Uplift 3=-2(LC 9) Max Grav 1=138(LC 1), 3=138(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 3-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V17 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115362 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:47 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-gWI0AFuEda7ao?lM0N24TyS1PjeJxmmFBYHsIVznULw Scale = 1:26.3 1 2 3 42x4 4x6 2x4 2x4 6-5-86-5-8 3-2-12 3-2-12 6-5-8 3-2-12 0-0-43-9-30-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.15 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-5-8, 3=6-5-8, 4=6-5-8 Max Horz 1=66(LC 11) Max Uplift 1=-14(LC 12), 3=-14(LC 12) Max Grav 1=145(LC 1), 3=145(LC 1), 4=180(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V18 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115363 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:48 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-8isONbusOtFRP8KZa4ZJ09?Fg70qgDIPQC1QqxznULv Scale = 1:15.8 1 2 3 4 2x4 4x6 2x4 2x4 4-5-84-5-8 2-2-12 2-2-12 4-5-8 2-2-12 0-0-42-7-30-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.06 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-5-8, 3=4-5-8, 4=4-5-8 Max Horz 1=43(LC 11) Max Uplift 1=-9(LC 12), 3=-9(LC 12) Max Grav 1=95(LC 1), 3=95(LC 1), 4=118(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V19 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115364 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:49 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-dvQmbwvU9BNI1Ivl8o4YYNXRoXM4PglYfsmzNOznULu Scale = 1:10.0 1 2 3 2x4 3x4 2x4 2-5-82-5-8 1-2-12 1-2-12 2-5-8 1-2-12 0-0-41-5-30-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-5-8, 3=2-5-8 Max Horz 1=-21(LC 10) Max Grav 1=73(LC 1), 3=73(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V20 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115365 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:49 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-dvQmbwvU9BNI1Ivl8o4YYNXQtXMGPglYfsmzNOznULu Scale = 1:9.7 1 2 3 2x4 2x4 2x4 2-4-3 2-4-3 0-0-41-4-77.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-4-3, 3=2-4-3 Max Horz 1=27(LC 11) Max Uplift 3=-1(LC 9) Max Grav 1=68(LC 1), 3=68(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V21 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115366 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:50 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-55_8oGw7vVV9fSUxiVcn5a4Xtxf987LhtWWXvqznULt Scale = 1:23.3 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 6-4-3 6-4-3 0-0-43-8-77.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.32 0.20 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-4-3, 4=6-4-3, 5=6-4-3 Max Horz 1=91(LC 11) Max Uplift 1=-15(LC 10), 4=-7(LC 9), 5=-25(LC 12) Max Grav 1=42(LC 9), 4=128(LC 17), 5=320(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 6-2-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V22 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115367 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:50 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-55_8oGw7vVV9fSUxiVcn5a4Yqxg486ihtWWXvqznULt Scale = 1:36.5 1 2 3 4 7 6 5 8 9 102x4 2x4 2x4 2x4 2x4 2x4 2x4 10-4-3 10-4-3 0-0-46-0-77.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.26 0.14 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-4-3. (lb) - Max Horz 1=155(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=446(LC 17), 7=295(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-271/130 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 10-2-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V23 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115368 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:51 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ZHYX0cxlgod0Hc38FD70dodg8K?FtYYr6AG4RGznULs Scale = 1:48.5 1 2 3 4 7 6 583x4 3x4 3x4 2x4 2x4 2x4 2x4 13-11-2 13-11-2 0-0-48-1-87.00 12 Plate Offsets (X,Y)-- [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.48 0.21 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.All bearings 13-11-2. (lb) - Max Horz 1=212(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=427(LC 17), 7=527(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-280/238 WEBS 2-7=-322/131 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 13-9-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V24 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115369 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:52 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1U6vDyxNR6ltumeKpweFA?9ufkLVc0x_Lq?dziznULr Scale = 1:38.9 1 2 3 4 7 6 5 8 9 3x4 2x4 2x4 2x4 2x4 2x4 2x4 11-0-13 11-0-13 0-0-46-5-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.14 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-0-13. (lb) - Max Horz 1=166(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=453(LC 17), 7=322(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-269/128 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 10-11-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V25 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115370 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:52 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1U6vDyxNR6ltumeKpweFA?9vTkMuc1c_Lq?dziznULr Scale = 1:30.0 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 8-2-8 8-2-8 0-0-44-9-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.25 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-2-8, 4=8-2-8, 5=8-2-8 Max Horz 1=121(LC 9) Max Uplift 4=-11(LC 9), 5=-29(LC 12) Max Grav 1=118(LC 18), 4=122(LC 17), 5=378(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-283/138 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 8-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V26 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115371 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-VgfHQIy?CQtkWwDWNd9UjDiyl8ctLTl8ZTlBW9znULq Scale = 1:19.3 1 2 3 4 5 2x4 2x4 2x4 5-4-4 5-4-4 0-0-43-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.73 0.46 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-4-4, 3=5-4-4 Max Horz 1=75(LC 9) Max Uplift 3=-3(LC 9) Max Grav 1=188(LC 1), 3=188(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 5-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V27 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115372 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-VgfHQIy?CQtkWwDWNd9UjDiu18aZLTl8ZTlBW9znULq Scale = 1:22.0 1 2 3 4 5 2x4 2x4 2x4 6-0-2 6-0-2 0-0-43-6-17.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.97 0.60 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-0-2, 3=6-0-2 Max Horz 1=86(LC 9) Max Uplift 3=-3(LC 9) Max Grav 1=215(LC 1), 3=215(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 5-10-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V28 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115373 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:54 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-zsDfeezdzj?b83oixLgjFQFEDY1?4vwHo7Uk2bznULp Scale: 3/8"=1' 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 8-10-6 8-10-6 0-0-45-2-17.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.14 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-10-6, 4=8-10-6, 5=8-10-6 Max Horz 1=131(LC 9) Max Uplift 4=-12(LC 9), 5=-32(LC 12) Max Grav 1=141(LC 18), 4=116(LC 17), 5=411(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-308/143 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 8-9-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V29 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115374 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:56 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-vFLP3K?tVLFINNx52miBKrKZ1LjRYpfaGRzr7UznULn Scale = 1:41.1 1 2 3 4 7 6 5 8 3x4 2x4 2x4 2x4 2x4 2x4 2x4 11-8-11 11-8-11 0-0-46-10-17.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.34 0.14 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-11. (lb) - Max Horz 1=177(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=446(LC 17), 7=356(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-265/125 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-8-11, Interior(1) 3-8-11 to 11-7-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V30 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115375 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:57 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ORvoGf?WGeN9?XWHcTEQt3thrl3MHEIjU5jOfwznULm Scale = 1:50.7 1 2 3 4 5 6 10 9 8 711 3x6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 14-6-1514-6-15 14-6-15 14-6-15 0-0-48-6-17.00 12 Plate Offsets (X,Y)-- [7:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.16 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7 REACTIONS.All bearings 14-6-15. (lb) - Max Horz 1=222(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 7, 1, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 7, 1 except 8=475(LC 17), 9=398(LC 17), 10=313(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-309/250, 2-4=-258/217 WEBS 5-8=-261/119 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 14-5-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 1, 8, 9, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V31 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115376 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:57 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ORvoGf?WGeN9?XWHcTEQt3tnTl3RHCQjU5jOfwznULm Scale = 1:71.4 1 2 3 4 5 6 7 13 12 11 10 9 814153x4 4x6 3x4 3x6 20-1-820-1-8 10-0-12 10-0-12 20-1-8 10-0-12 0-0-411-8-140-0-414.00 12 Plate Offsets (X,Y)-- [4:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.17 0.16 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 20-1-8. (lb) - Max Horz 1=-219(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 7, 13, 8 except 1=-121(LC 10), 11=-128(LC 12), 9=-129(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=321(LC 17), 11=518(LC 17), 13=355(LC 17), 9=516(LC 18), 8=358(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-317/201, 5-9=-317/201 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 10-0-12, Exterior(2R) 10-0-12 to 13-0-12, Interior(1) 13-0-12 to 19-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 13, 8 except (jt=lb) 1=121, 11=128, 9=129. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V32 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115377 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:58 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-seTAU?081yV0ch5UABlfQGPx19Lt0ghtjlSyBMznULl Scale = 1:65.8 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 18-1-818-1-8 9-0-12 9-0-12 18-1-8 9-0-12 0-0-410-6-140-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.25 0.34 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS.All bearings 18-1-8. (lb) - Max Horz 1=-197(LC 10) Max Uplift All uplift 100 lb or less at joint(s) except 9=-157(LC 12), 6=-157(LC 12) Max Grav All reactions 250 lb or less at joint(s) 5 except 1=260(LC 18), 8=281(LC 17), 9=586(LC 17), 6=586(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-377/237, 4-6=-380/238 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 9-0-12, Exterior(2R) 9-0-12 to 12-0-12, Interior(1) 12-0-12 to 17-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 157 lb uplift at joint 9 and 157 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V33 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115378 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:47:59 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-Kq1YhL1moGdtErggjuGuyUy7qZi?l9u0yPCVjoznULk Scale = 1:57.7 1 2 3 4 5 8 7 63x4 4x6 3x4 5x6 2x4 2x4 2x4 2x4 16-1-816-1-8 8-0-12 8-0-12 16-1-8 8-0-12 0-0-49-4-140-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14], [7:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.18 0.28 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 16-1-8. (lb) - Max Horz 1=174(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-135(LC 12), 6=-136(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=306(LC 17), 8=511(LC 17), 6=508(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-333/212, 4-6=-335/212 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 8-0-12, Exterior(2R) 8-0-12 to 11-0-12, Interior(1) 11-0-12 to 15-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=135, 6=136. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V34 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115379 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:48:00 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-o0awuh2OZZmks?FsHcn7VhUIxz4FUcrAB3x2GFznULj Scale = 1:50.8 1 2 3 4 5 8 7 69103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 14-1-814-1-8 7-0-12 7-0-12 14-1-8 7-0-12 0-0-48-2-140-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.15 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-1-8. (lb) - Max Horz 1=152(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-119(LC 12), 6=-119(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=316(LC 17), 8=440(LC 17), 6=440(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-299/193, 4-6=-299/193 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-0-11, Interior(1) 3-0-11 to 7-0-12, Exterior(2R) 7-0-12 to 10-0-12, Interior(1) 10-0-12 to 13-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=119, 6=119. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V35 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115380 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:48:01 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GC8I6120KtubT8q3rJIM1v1TjMQbD4qJPjhcohznULi Scale = 1:43.8 1 2 3 4 5 8 7 69103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 12-1-812-1-8 6-0-12 6-0-12 12-1-8 6-0-12 0-0-47-0-140-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.15 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-1-8. (lb) - Max Horz 1=129(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-111(LC 12), 6=-111(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=312(LC 17), 8=394(LC 17), 6=393(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-286/187, 4-6=-286/187 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 6-0-12, Exterior(2R) 6-0-12 to 9-0-12, Interior(1) 9-0-12 to 11-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=111, 6=111. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V36 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115381 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:48:01 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GC8I6120KtubT8q3rJIM1v1NnMPnD4nJPjhcohznULi Scale = 1:38.4 1 2 3 43x4 4x6 3x4 2x4 10-1-810-1-8 5-0-12 5-0-12 10-1-8 5-0-12 0-0-45-10-140-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.20 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-1-8, 3=10-1-8, 4=10-1-8 Max Horz 1=-107(LC 10) Max Uplift 1=-8(LC 12), 3=-8(LC 12) Max Grav 1=221(LC 1), 3=221(LC 1), 4=317(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 5-0-12, Exterior(2R) 5-0-12 to 8-0-12, Interior(1) 8-0-12 to 9-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V37 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115382 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:48:02 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-kPihJN3e5B0S5IPFP0pba6aZZmnEyY1TeNQ9K7znULh Scale: 3/8"=1' 1 2 3 42x4 4x6 2x4 2x4 8-1-88-1-8 4-0-12 4-0-12 8-1-8 4-0-12 0-0-44-8-140-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.47 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-1-8, 3=8-1-8, 4=8-1-8 Max Horz 1=-84(LC 10) Max Uplift 1=-17(LC 12), 3=-17(LC 12) Max Grav 1=188(LC 1), 3=188(LC 1), 4=231(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 4-0-12, Exterior(2R) 4-0-12 to 7-0-12, Interior(1) 7-0-12 to 7-9-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V38 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115383 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:48:03 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-CbG3Xj4GsU8JjS_RykKq7K6nuA6Jh?oct1AjsaznULg Scale = 1:25.1 1 2 3 42x4 4x6 2x4 2x4 6-1-86-1-8 3-0-12 3-0-12 6-1-8 3-0-12 0-0-43-6-140-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.13 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-1-8, 3=6-1-8, 4=6-1-8 Max Horz 1=62(LC 11) Max Uplift 1=-13(LC 12), 3=-13(LC 12) Max Grav 1=136(LC 1), 3=136(LC 1), 4=170(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 7,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_TROY_ESTATES Truss V39 Truss Type Valley Qty 1 Ply 1 19 Troy Estates Job Reference (optional) I50115384 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Feb 7 15:48:04 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-gnqRk35vcoGAKcZdWRs3fXf?YaTWQSNl5hvGP0znULf Scale = 1:12.3 1 2 3 4 5 2x4 3x4 2x4 2x4 5x6 4-1-84-1-8 1-7-10 1-7-10 2-5-14 0-10-4 4-1-8 1-7-10 0-0-41-10-140-0-41-10-1414.00 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge], [3:0-4-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.07 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-8 oc purlins, except 2-0-0 oc purlins: 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-1-8, 4=4-1-8, 5=4-1-8 Max Horz 1=-31(LC 10) Max Uplift 1=-7(LC 12), 4=-13(LC 12) Max Grav 1=120(LC 1), 4=107(LC 1), 5=94(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 7,2022 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths