Loading...
HomeMy WebLinkAboutA111a - PARTIAL GROUND FLOOR PLANS - BUILDING A - CopyUP 819.23819.73820.23820.69821.13KEY PLANGENERAL PLAN NOTES FIRE RESISTANCE RATED SEPARATION LEGEND 25 A203 25 A204 10 A204 MATCHLINE REFER TO 28 / A111a MATCHLINE REFER TO 28 / A111a 13 A20141'-9" 75'-3"68'-1" ELEV. A2 STAIR A2 4 A203 10 A203 26 A402 3 2 1 A B C D E F G SL SD SJ3 SD SJ4 SJ5 A103a A103b RETAIL SPACE A101 RETAIL SPACE A103 A103e A103f A103g A103c SJ2 SJ2 SJ2 SO SJ5 SO 4 A117 7 A117 10 A117 25 A117 26 A117 DASHED LINE INDICATES OPEN SHAFT LOCATION IN CONCRETE PODIUM LINE OF SLAB LEAVE-OUT, TYP.SM 66'-3 5/8"77'-1 1/4"35'-10 5/8"18'-10"24'-9 5/8"20'-3 3/8" 20'-4" SL1 SO2 SO2 SJ2 B.3 2 A111c A101b A101c A101dA101e L L L L 36'-1" 25'-9" 11'-3" 2'-2"3'-2 1/4" 12'-4" 3'-10"12'-4" 4'-4 3/4" 1'-7 1/4"9'-1 1/2"3'-4" 9'-0" 2'-8 1/4"49'-5 1/4" 8'-10" 7'-11 3/4"23'-8"8'-0" 4'-2" 67'-7" 49'-5 1/2" 8'-10" 9'-3 1/2"14'-1"8'-0" 21'-8" 8'-0" 11'-8 3/4" 8'-0" 9'-11" 1'-9 3/4" 27'-7" 23'-2" 1'-0"3'-6 5/8"6'-0" 4'-11 7/8" 4'-0" 4'-0" 4'-11 7/8" 6'-0" 3'-6 5/8"37'-1" 16'-11 3/4" 6'-1 3/4" 8'-0"1'-11"8'-0" 8'-7" 8'-0"7A2027A204MATCHLINE REFER TO 25 / A111a MATCHLINE REFER TO 25 / A111a MATCHLINEREFER TO 25 / A111bMATCHLINEREFER TO 25 / A111b37'-8 3/4" 94'-5 3/4"STAIR A3TRASH A105 78'-9 1/4"PUMP ROOM A106 27 A403 6 5 4 3 2 1 H J K L M N AA AB AC AD AE AF AG A2 A3 A1 SN SO2 SN A104b A104c A104d RETAIL SPACE A104 SJ4 SJ4 SJ5 A104a SJ4 SJ4 SJ4 A107a A104e A103d SJ5 SJ2 SJ2 26 A118 15 A118 27 A118 DASHED LINE INDICATESOPEN SHAF T LOCATIONIN CONCRETE PODIUMSTEPLINE OF SLABLEAVE-OUTSJ7 SJ4 SJ4 SJ4 SJ412'-1"8'-0" 10'-2 3/4" 25 A190 821' - 3 1/2" 818' - 6 1/2" DN L L L H H L 2'-6 3/4" 8'-0" 15'-1 1/4"63'-8" 8'-0" 7'-1 1/4"8'-0"8'-10 1/4" 8'-0" 7'-2 1/2" 3'-0" 8'-0" 3'-7 3/4"8'-0"3'-9 1/4" 2'-2 1/2"8'-0" 2'-4"8'-0" 2'- 5 3/4"9'-2 1/2"10'-0" 3'-0" 12'-4" 3'-0" 10'-0" 9'-2 1/2" 2'-5 3/4"8'-0" 2'-4"8'-0" 2'-2 1/2"3'-9 1/4"8'-0"2'-11 1/4"2'-3" 8'-0" 2'-3"4'-8 3/4" 4'-2" 8'-0" 2'-5 3/4" 1'-6" 8'-0" 6'-6 1/2" 25 / A111a28 / A111aBUILDING B GARAGE BUILDING A 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.9/7/2021 9:56:35 AM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt LRK Project Number: 01.18066.00 A111a PARTIAL GROUND FLOOR PLANS -BUILDING A VWB SWMThe Corner Carmel, IN •01.18066.00The Corner - Building A 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 PARTIAL GROUND FLOOR PLAN -BUILDING A SCALE: 1/8" = 1'-0" 28 PARTIAL GROUND FLOOR PLAN -BUILDING A 06.16.21 Permit Set A 07.15.21 Addendum A C 09.01.21 IFC Set 11/15/21