HomeMy WebLinkAboutA112b - PARTIAL SECOND FLOOR PLANS - BUILDING A - CopyKEY PLANGENERAL PLAN NOTES FIRE RESISTANCE RATED SEPARATION LEGEND 25 A205 7 A205 A1d A233 A1d A231 A1d A229 A1c A227 B1d A228 B1k A236 13 A231 A1f A239 B1r A238 MATCHLINEREFER TO 28 / A112aMATCHLINEREFER TO 28 / A112a35'-0" 1" A.S. 31'-6"SHAFTELEV. A1SHAFT PEDESTRIAN BRIDGE S1 A235 24'-2" 1" A.S. 23'-10" 1" A.S. 24'-0" 1" A.S. 18'-0" 1" A.S. 24'-0" 1" A.S. 24'-0" 1" A.S. 24'-0" 1" A.S. 24'-0" 4" F.W. 6'-6 3/4" B1e A230 A1d A237 ? ? STORAGE A243 MECH. A245 TELECOMM. A246 ELEC.A244STAIR A1 A248 14 A401 28 A161a 28 A161a 28 A161a 28 A161a 29 A151 29 A171a 13 A171a 17 A171a 27 A171a 26 A161a A242b A241aA242a A1c A227 17 A161a 25 A119 FECFECEXPANSION JOINT COVER PLATE EXPANSION JOINT COVER PLATE EXPANSION JOINT COVER PLATE 2" EXPANSION JOINT THROUGH BUILDING 36'-2" 1" 36'-0" A.S. 1" A.S. 18'-0" 1" A.S. 24'-0" 1" A.S. 36'-0" 1" A.S. 36'-0" F.W. 4" S3 A234 A5 A232 29 A165 29 A153 BUILDING B GARAGE BUILDING A1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.9/3/2021 2:38:40 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt LRK Project Number: 01.18066.00 A112b PARTIAL SECOND FLOOR PLANS -BUILDING A The Corner Carmel, IN VWB SWMThe Corner Carmel, IN •01.18066.001685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 PARTIAL SECOND FLOOR PLAN -BUILDING A 28/A112b 06.16.21 Permit Set A 07.15.21 Addendum A B 08.20.21 IFC Set C 09.01.21 IFC Set 11/15/21