HomeMy WebLinkAboutA403 - STAIR A3 - FLOOR PLANS AND SECTIONUP DN UP UP DN UP DN 29 A403 L A1 A106 PUMP ROOM A106 A105 TRASH A105 STAIR A3 A149 6"4'-2 1/4" 23'-9 3/4" 9'-8 3/4"1'-0" 9'-5" 6" CLEQ EQCL 2'-0 1/2" 2'-10 1/2" 12 TREADS AT 11" EACH 11'-0" LANDING 6'-3 7/8" H CL4'-6" 4'-11" 11 TREADS AT 11" EACH 10'-1"CL7'-0 1/2" 2'-3 1/4"A149b A149a CLR. 3'-11 5/8" 9 1/2" CLR.3'-11 5/8"11'-9 1/2"4'-0" 20'-7 1/4"F 12'-1"SPARE CONTAINERS TRASH COMPACTOR P L 13 A501 H STANDPIPE 29 A403 A2A1 A241fCORRIDORA241 STAIR A3 A249 7 5/8" 22'-7 1/4" 7 5/8" 5'-0 1/2"CLEQEQ CL EQEQ A249 A 9 TREADS AT 11" EACH 8'-3" LANDING 4'-4 3/8" 12 TREADS AT 11" EACH 11'-0" 7'-2 7/8" 7 5/8" 5'-0 1/2" CLR. 3'-11 5/8" 9 1/2" CLR.3'-11 5/8"11'-9 1/2" 4'-4 3/8" CL2'-2"A241d 1/2" A.S. 7 3/4" 8'-8 3/4" 7 3/4" 3/4" A.S.4 A401 Sim C 2 HR SHAFTLINER PARTITION CL 2'-4"1/2" A.S. 5'-7 1/4" 5" 3'-5" 1/2" A.S. STANDPIPE 29 A403 A341d CORRIDOR A341 A441d A441 A541 A541d STAIR A3 A349 A449 A449 A549 A549 A349 10'-10 7/8" 8 TREADS AT 11" EACH 7'-4" LANDING 4'-7 3/8"CLEQEQ 10'-0 1/2"CL EQEQ CLR.3'-11 5/8"9 1/2" CLR. 3'-11 5/8" D 9 TREADS AT 11" EACH 8'-3" 11'-9 1/2"4'-4 3/8" 5'-0 1/2" 7 5/8" 22'-10 1/4" F F F K A C 2 HR SHAFTLINER PARTITION CL 2'-4"1/2" A.S.3'-5" 5" 5'-7 1/4" 1/2" A.S.STANDPIPE BLDG A L 05 +871' -10 1/16" BLDG A TRUSS BEARING +880' -11 3/16" BLDG A L 02 +839' -10 7/16" BLDG A L 03 +850' -6 5/16" BLDG A L 04 +861' -2 3/16" A1 BLDG A L 01.2 +818' -6 23/32"12'-1 1/8"9'-1 1/8" 10'-7 7/8" 10'-7 7/8" 10'-7 7/8" 21'-3 23/32" AT 6.90" EACH11 RISERSAT 6.90" EACH 12 RISERS AT 6.80" EACH 9 RISERS AT 6.80" EACH 10 RISERS AT 6.80" EACH 9 RISERS AT 6.80" EACH 10 RISERS AT 6.80" EACH 9 RISERS AT 6.80" EACH 10 RISERS AT 6.91" EACH 13 RISERS AT 6.91" EACH 12 RISERS AT 6.91" EACH 12 RISERS 6'-8" MINIMUM HEAD CLEARANCE 6'-8" MINIMUM HEAD CLEARANCE 6'-8" MINIMUM HEAD CLEARANCE 6'-8" MINIMUM HEAD CLEARANCE 6'-8" MINIMUM HEAD CLEARANCE 6'-8" MINIMUM HEAD CLEARANCE 8'-0"3'-6"4 FULL DIAMETER VENT THROUGH ROOF AT TRASH CHUTE 5'-9 1/4"PROVIDE SANITIZING UNIT TRASH CHUTE 15"x18" STAINLESS STEEL CLAD INTAKE DOOR 15"x18" STAINLESS STEEL CLAD INTAKE DOOR 15"x18" STAINLESS STEEL CLAD INTAKE DOOR 15"x18" STAINLESS STEEL CLAD INTAKE DOOR3'-5 3/8" 3'-5 3/8" 3'-5 3/8"29 A403 STAIR A3 A649 23'-11 3/8" 11 TREADS AT 11" EACH 10'-1" LANDING 4'-4 3/8" 9 TREADS AT 11" EACH 9'-2" 9'-0 7/8" 2 TREADS AT 11" EACH 1'-10"CL7'-4 3/8" 2'-7 5/8"10'-0"CLR. 3'-11 5/8" 9 1/2" CLR.3'-11 5/8"A649 F F F K STANDPIPE 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.9/3/2021 2:45:12 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt LRK Project Number: 01.18066.00 A403 STAIR A3 -FLOOR PLANS AND SECTION The Corner Carmel, IN VWB SWMThe Corner Carmel, IN •01.18066.001685 E. 116th Street, Carmel, IN SCALE: 1/4" = 1'-0" 27 GROUND FLOOR PLAN -STAIR A3 SCALE: 1/4" = 1'-0" 15 SECOND FLOOR PLAN -STAIR A3 SCALE: 1/4" = 1'-0" 9 TYPICAL UPPER FLOOR PLAN -STAIR A3 SCALE: 1/4" = 1'-0" 29 SECTION -STAIR A3 SCALE: 1/4" = 1'-0" 7 ROOFTOP FLOOR PLAN -STAIR A3 06.16.21 Permit Set A 07.15.21 Addendum A B 08.20.21 IFC Set C 09.01.21 IFC Set 11/15/21